Decaroc - Mineral wool panels

Similar documents
FIREPROOF Panels Trimoterm

Master Panel 1000 W Wall

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Master Panel 1000 R5 Roof

Product Data Sheet ROCKPANEL Rockclad

Hoesch Matrix System individuell. ThyssenKrupp Steel Europe Thinking the future of steel

OWAplan1. The seamless acoustic ceiling. Pure acoustics. Pure design.

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

Composite Panel Firewall Systems

Light-Weight Panels. High quality panels.

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Armanet BEKAERT. Armanet THE CONSTRUCTIVE IDEA. Render & plaster @@@

Cable Trays Technical Instructions & Specifications

Understanding BS EN 771-3: Aggregate concrete masonry units

Plaisance 24. Sliding Systems. Sapa Building System

Rockwool Cladding Roll

Rockwool Flexi Insulation Application Guide

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Quality Regulations for Profiles

INDEX. Chapter8. air master. Perforated Ceiling Diffusers

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Supply air diffuser ROKA/RPKA

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Technical Data Sheet W13. Edition Knauf Fire Walls

Confort 26. Sliding Systems. Sapa Building System

Our bestsellers THE BASIS FOR SUSTAINABLE INTERIOR DECORATING PROJECTS. OWAlifetime collection

Ecophon Focus A. System range. Size, mm. XL 2000x600. XL 1800x600. XL 2400x600 T15 T24 Thickness (THK) Inst. Diagr. 1200x x x600

Module 3.7. Thermal bridging

PART 1 GENERAL 1.1 SECTION INCLUDES

Authorized Dealers Access Floors Limited The Studio 15 Huntsmead Northampton NN3 5HT

CRN A-F-G-E-HQQE 3x400D 50 HZ

Swirl diffuser VSKA. Product facts. Quick selection. Swirl diffuser VSKA. Connection box ATTB. Product code example:

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

RPV - RP - RA air handling units

Edition: Export Published: 09/2010. Product catalogue. Technical and industrial insulation. Lapinus

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

SL30-ISO PROFILE SYSTEM

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

Testing Rules for Thermal Conductivity October 2015

PMA MEDOC SHELLS USER S GUIDE

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Modular Access Floor for Data Center. From Rack to Row to Room to Building

DELTA SYSTEMS DELTA. The company, products and the service. in 150 mm to 600 mm modules are formed on a

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS

High-speed folding doors. F Series

HVAC Insulation. Insulation Solutions for HVAC Applications. New CE marking and Isover CLIM product range

European Technical Approval ETA 13/0384

ProRox Slabs (formerly known as RW slabs)

PanelTack. For the bonding of steni Colour type 7 façade panels. steni Colour 7. steni Colour 7

Architectural composite panels

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

BETONYP building boards. The modern way of living.

Prefabricated building PVC vertical sliding window

Concepts. Products. Service. Glass partitions Lindner Life

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

Concepts. Products. Service. From one source. Plafotherm Plasterboard Heated and Chilled Ceilings

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick

Mineral fibreglass insulation

Innovators in steel buildings Innovators in steel buildings CEPTRA

European Technical Approval ETA 13/0526

COLD Heat Fire

Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER

SmartPly OSB3 SMARTPLY

Ecophon Focus Ds. System range. XL 1800x600. Size, mm. XL 2400x600 T24 Thickness (THK) XL 2000x x x x600 M206, M208, M238

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

Façade panels for interior cladding on a wooden supporting structure

Avantis 75. Windows & Doors. Sapa Building System

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Unbeatable energy efficient glass curtain wall system

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

TIGER Drylac U.S.A., Inc Swenson Avenue St Charles, IL T F office.us@tiger-coatings.us

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

Passive Fire Protection

SANDWICH PANEL FILLING MATERIALS

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

New: Standard Safety Light Grille. High-Speed Doors

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

Light Architecture. Colors Sweden. Light

Mold Preventing I nterior System

ALUMINIUM. Product Data Sheet

How To Make A Supply Air Ceiling

Fire Resistant Systems

Initial Type Testing Report

Brochure EX

Innovators in steel buildings Innovators in steel buildings ASTRIGMA

Confort 160. Sliding Systems. Sapa Building System

Structural fire design Eurocode Timber structures

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

Longspan. Insulated Panels. Architectural Frame to Frame Insulated Panel System. CI/SfB (4-) Rh2 September 2008

Transcription:

Decaroc - Mineral wool panels Isotherm constructions

03 Decaroc Mineral wool panels Up to 120 minutes fi re-resistance! Decaroc Mineral wool panel is a sandwichpanel with a mineral wool core with a width of 1170 mm which can be erected vertical or horizontal. The Decaroc Mineral wool panel can be used as a separation wall or fi re wall and as a ceiling in buildings as well as an exterior wall. Fire resistance according EN 13501-2 - Thickness 80 mm as wall, horizontal up to 4m span : EI 60 - Thickness 80 mm as wall, vertical up to 4m span : EI 60 - Thickness 100 mm as wall, horizontal up to 6m span : EI 90 - Thickness 100 mm as wall, vertical up to 6m span : EI 90 - Thickness 120 mm as wall, horizontal up to 6m span : EI 120 - Thickness 120 mm as wall, vertical up to 6m span : EI 120 - Thickness 120 mm as ceiling, up to 5m span : REI 120 Fire reaction according EN 13501-1 - A2s1,d0 (the panel) - A1 (mineral wool core) R = load-bearing capacity E = Integrity I = Insulation REI = load-bearing, integrity, insulation EI = Integrity, Insulation

04 Decaroc - Mineral wool panels Characteristics Types 050C - 050F Dimensions Module : - Width : 1.170 mm - Total width : 1.186 mm Length : - Available on measure per 10 mm - Minimum length : 2.000 mm - Maximum length : 15.000 mm (dependent on thickness) Types : - 60 / 80 / 100 / 120 / 150 / 200 / 240 / 300 mm Tolerances (from EN 14509) - Width : ± 2 mm - Length : ± 5 mm ( L < = 3.000 mm ) ± 10 mm ( L > 3.000 mm ) - Thickness : ± 2 mm ( D < = 100 mm ) ± 2 % ( D > 100 mm ) on real thickness Aspect Standard : Slightly ribbed Option : - Linea - Smooth (excl. stainless steel fi nishing) Insulation Decaroc Rockwool consists of 95 to 99 % melted vulcanic rock drawn to fi bre in order to receive a fi brous structure. The rockwool fi bres are uniformaly split in order to keep the shearstrength constant. Characteristics : - Thermal insulation - Acoustic insulation - Incombustible material Lambda value : (EN 13162, EN14509, declared value) - Type : 050C : 42 mw/mk 050F : 45 mw/mk U-Value (W/m 2 K) 60 80 100 120 150 200 240 300 050C 0,656 0,498 0,400 0,334 0,289 0,205 0,172 0,146 050F 0,702 0,533 0,429 0,358 0,310 0,220 0,184 0,157 Mechanical properties Decaroc Rockwool panels have a rockwool core specially produced and designed for sandwichpanels. That s why a subdivision in types is made according to the mechanical characteristics, fi re resistance and not only according to the density of the rockwool. Type : 050C 050F (better fi re-resistance) Weight Kg/m 2 60 80 100 120 150 200 240 300 050C 14,4 16,2 17,9 19,7 22,3 26,5 29,9 35,4 050F 16,3 18,6 21,0 23,4 26,9 32,6 37,2 44,6

05 Decaroc - Mineral wool panels Characteristics Fire characteristics Fire reaction - Decaroc Mineral wool panels : fi re class A2S1d0 according EN13501-1 and EN14509 - Rockwool core : fi re class A1 according EN13501-1 Fire resistance - according EN 13501-2 - Thickness 80 mm as wall, horizontal up to 4m span : EI 60 - Thickness 80 mm as wall, vertical up to 4m span : EI 60 - Thickness 100 mm as wall, horizontal up to 6m span : EI 90 - Thickness 100 mm as wall, vertical up to 6m span : EI 90 - Thickness 120 mm as wall, horizontal up to 6m span : EI 120 - Thickness 120 mm as wall, vertical up to 6m span : EI 120 - Thickness 120 mm as ceiling, up to 5m span : REI 120 Decaroc - Accoustic - The Deacroc accoustic mineral wool panels are used for noise reduction in internal walls and ceilings for instance in machinerooms, control rooms, car inspection rooms, etc. - Note that the acoustic panel is only for use in dry, normal internal climate conditions, not for external use. - The perforated steel sheet is only on one surface. Sound reduction 50F perforated Decaroc 60 : Rw = 32 db ; S = 0,85 Decaroc 100 : Rw = 34 db ; S = 0,90 Perforation 11,25 5 D-pitch 11,25 perforation grade 17,5% 50F non perforated Decaroc 60 : Rw = 29 db ; S = 0,15 Decaroc 100 : Rw = 30 db ; S = 0,10 11,25 Rw = Sound reduction index S = Sound absorption coeffi cient 5 According to: EN ISO 354:2003, EN ISO 140-3:1995 Perforation pattern

06 Decaroc - Mineral wool panels Finishing Standard finishing Lacquered galvanized steelplate with protection fi lm. Thickness : 0,53 mm / 0,53 mm - coating included Colour : white 9002 (RAL) or 9010 (RAL) Lacquer : Polyestercoating 20µm + 5µm primer Food quality Application : for interior and exterior use (non-agressive environment) Other colours : see ISOCAB colour range Finishing in option HDP 35µm - High Durable Polymer - Thickness : 0,63 mm - coating included - Thickness : 0,78 mm - coating included - Food quality PET film 55µm Polyestercoating + Polyethylene-tereftalate fi lm - Colour : white 9002 (RAL) and 9010 (RAL) - Thickness : 0,55 mm - coating included - Thickness : 0,65 mm - coating included - Food quality - Only for interior use - High chemical resistance durability STAINLESS STEEL AISI 304-316 L - Pinpoint fi nish - Line brushed fi nish - Aspect 2B - Food quality Polyestercoating 15µm (interieur-coating) - Colour : white 9002 (RAL) - Thickness : 0,52 mm coating included - Thickness : 0,77 mm coating included - Without protection fi lm Aluminium zinc - Thickness : 0,50 mm - 185 gr/m 2 2 sides - Without protection fi lm

07 Decaroc 050F Span table wall DECAROC 050F - SPAN TABLE WALL ADMISSIBLE DEVIDED LOAD IN FUNCTION OF THE SPAN Security factor S = min 3 maximum bending = L/200 L WIND PRESSURE - 2 SUPPORTS (dan/m 2 ) SPAN WIND SUCTION - 2 SUPPORTS (dan/m 2 ) 150 120 100 80 60 L in m 60 80 100 120 150 486 360 277 233 199 2,00 184 266 282 318 522 422 310 235 208 156 2,25 151 224 240 253 434 373 271 204 188 125 2,50 127 193 209 207 369 334 241 180 171 103 2,75 109 169 185 172 319 302 217 160 157 86 3,00 95 150 165 146 280 275 197 145 146 75 3,25 95 135 149 125 249 253 180 131 135 66 3,50 80 122 136 109 223 234 167 122 122 59 3,75 69 122 136 109 202 218 155 113 110 53 4,00 60 104 118 100 184 196 142 106 100 49 4,25 52 90 104 93 184 178 131 99 92 45 4,50 49 78 92 87 167 162 121 94 85 41 4,75 46 68 82 82 152 148 112 88 79 38 5,00 44 60 74 77 139 136 107 87 73 5,25 53 67 73 128 126 102 86 66 5,50 51 58 67 119 117 97 84 59 5,75 49 51 62 110 109 93 83 53 6,00 46 45 58 103 100 86 76 48 6,25 45 39 54 96 92 79 69 44 6,50 43 35 51 89 86 73 64 6,75 31 48 83 79 67 59 7,00 27 45 77 74 62 7,25 43 72 69 58 7,50 41 67 64 54 7,75 38 63 60 50 8,00 37 59 L L WIND PRESSURE - 3 SUPPORTS (dan/m 2 ) SPAN WIND SUCTION - 3 SUPPORTS (dan/m 2 ) 150 120 100 80 60 L in m 60 80 100 120 150 261 198 156 131 87 2,50 88 134 124 215 275 234 176 137 115 83 2,75 93 117 114 189 240 212 158 123 102 79 3,00 95 104 105 169 212 194 144 111 92 75 3,25 85 93 97 153 190 178 132 101 83 71 3,50 76 85 90 139 171 165 121 92 76 68 3,75 69 77 85 127 156 154 113 85 71 65 4,00 64 71 79 118 143 144 105 79 66 62 4,25 59 66 75 109 132 135 98 74 62 59 4,50 54 61 71 102 122 127 92 69 58 57 4,75 50 57 67 95 114 121 87 65 55 54 5,00 47 53 64 90 107 114 83 61 52 52 5,25 44 50 61 85 100 106 76 57 50 50 5,50 42 47 57 78 92 98 71 52 47 5,75 45 53 72 85 92 66 49 45 6,00 42 49 67 78 86 62 46 43 6,25 40 46 62 73 80 58 43 42 6,50 38 43 58 68 76 54 40 6,75 41 54 63 71 7,00 59

Isocab NV Treurnietstraat 10, 8531 Bavikhove - Harelbeke, Belgium Tel: +32 (0)56 73 43 11, Fax: +32 (0)56 73 43 22 www.isocab.com - info@isocab.be Isocab France SAS Z.I. de Grande Synthe, 3 Rue Charles Fourier, CS 30142, 59792 Grande Synthe Cedex, France Tél: +33 (0)3 28 29 24 40, Fax: +33 (0)3 28 29 24 50 www.isocab.com - info@isocabfrance.fr All details contained in this brochure are only guaranteed insofar as they have been expressly and specifically confirmed in writing. Subject to technical modifications. GB Info 2.3.1. 1.2005 LB IND-121212-E