OUTDOOR DUAL-IR SENSOR USER MANUAL (VERSION 2.5

Similar documents
PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Wireless Alarm system s manual

LED Security Spotlight User Manual

FSLIMRF

REDWALL-V adjustment procedures guide

KEETEC BS 400 KEETEC BS 400 LED USER'S MANUAL

WIRELESS MAGNETIC CONTACT

90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F

WIRELESS WATER LEAK DETECTOR

GSM Home Alarm System User Manual.

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

FIRERAY 2000 Installation Guide

This icon denotes a situation involving the risk of serious injury or even death, if the warning given is ignored.

4.3-inch Back-Up Camera

SELF LEARNING PARKING SENSOR KIT USER MANUAL AVRSLRN

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

IN-OUT Thermometer with Cable Free Sensor and Clock

5W LED Energy Saver PIR Bulkhead

Polarization of Light

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

o^c a (fg 1) Telephone Line Socket ( flcg. 2b ) ) fig. 2a ) TeiePhone b ^^I r DC Adaptor

GSM ALARM SYSTEM USER MANUAL

Alignement of a ring cavity laser

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Wireless Home Security Alarm System AM 500

AX-100TFR/AX-200 TFR INSTALLATION INSTRUCTIONS INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR.

Owner s Manual

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL

WIRELESS HOME ALARM SYSTEM (WHA1)

Beam Laser Pointer Service Manual

1pcs. 1pcs. 2pcs 1pcs 1pcs 2pcs

LED MOTION ACTIVATED FLOOD LIGHT

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products

INTRUSION ALARM SYSTEM

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential Control Panels

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

2M IR Mini Dome Quick Installation Guide

Six-defense zone Display Alarm System. User Manual

Passive Infrared Motion Detector 5420/90. Installation Instructions

PiSector Home security systems

CS848E Receiver for 868GEN2 Devices Installation Sheet

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Wireless Indoor/ Outdoor Thermometer

Duct Humidity Transmitter

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

Version 2.0. Camera Placement and Location

Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

Home Security Alarm System

ALARM SYSTEM INSTALLATION GUIDE

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

How To Make A Commercial Detector

Intelligent GSM Auto-dial Alarm System User s Manual

DCMT-2500 Wireless Transmitter. Owner s Manual

Alarm Security Kit - NVR

GSM Alarm System User Manual

HDTV Anywhere USER MANUAL / HDTV Anywhere ALL RIGHTS RESERVED MARMITEK

OC821 Iris Outdoor Camera Set-Up Guide. RC8221 Iris. Camera Set-Up Guide

39HQ Airovision Air Handling Units

Additional Instruction

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

Wireless Auto-dial Intruder Alarm System

AN ESTIMATION OF A PASSIVE INFRA-RED SENSOR'S PROBABILITY OF DETECTION

EF70-200mm F2.8L IS USM. Instruction

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Be careful not to scratch or hit front edge of the side viewing micro prisms onto hard objects!

TRIMBLE TX5 3D LASER SCANNER QUICK START GUIDE

User Manual CN2HK LIMITED. Complete Wireless Home Alarm Security System (CK-8806) ENG. Please read this manual before operating this product.

Business/ Home GSM Alarm System

Treasure Cove Metal Detector

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

INFRARED QUARTZ WALL HEATER

LUCCI AIRFUSION QUEST II CEILING FAN

Your Simple Guide to Battery. Replacement. Customer Care:

Q-Scan UniComm V2.0. User Manual. Q-Scan People Counters

User Guide. Model: MAS-WA-SYS

Dome Security Camera with IR night vision

Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

EF24-105mm f/4l IS USM

EF70-300mm f/4-5.6 IS USM

Interference. Physics 102 Workshop #3. General Instructions

Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions

Infrarot-Bewegungsmelder IP44

Dome Camera with IR Night Vision

DIY QUAD. Build Manual V.A 2014

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

IP Camera User Manual

2-Way Wireless Indoor Siren Installation Guide

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

Intruder Alarm System

3D GLASSES FOR SHARP 3D AQUOS OPERATION MANUAL

Installation Instructions. Wireless Adapter/Repeater. Introduction Rev C

Transcription:

DIRRVE - DIRFE OUTDOOR DUL-IR SENSOR USER MNUL (VERSION 2.5 2.5) We thank you very much for choosing our product. Now we would like to invite you to read carefully the following instructions before installing the product in order to use all its capacities. This electronic device is compliant to the essential requirements of the European Union (EU) norms, concerning the electromagnetic compatibility and the electric safety.

DIRRVE DIRFE Outdoor DUL-IR sensor DIRRVE / DIRFE is an innovative passive infrared sensor for outdoor use. It has two PIR detection heads that are completely independent and can be separately adjusted. This allow to obtain a great functioning versatility and contemporary, if correctly installed, an excellent reduction of unwanted alarm. Infact the sensor can work with two different logic combinations between the two heads: OR logic or ND logic. In OR mode, the sensor gives alarm when any one of the sensible elements detects a movement. In ND mode, the sensor gives alarm only when both elements detect a movement. It is also possible to select a directional ND mode. LL THIS MENS MORE SECURITY ND LESS UNWNTED LRMS. VILBLE MODELS: DIRRVE wireless version DIRFE wired version Both the models are identical in functionality and optical performances. They only differ for the alarm transmission method. 2 DIRRVE-DIRFE V2.5

WRNING DIRRVE-DIRFE HS BEEN DESIGNED TO GURNTEE VERY HIGH IMMUNITY TO LIGHT INTERFERENCE, HOWEVER VERY BRIGHT LIGHT CN PRODUCE RNGE DECRESE. IT IS THEREFORE RECOMMENDED TO TKE GRET CRE IN INSTLLTION TO VOID DIRECT OR REFLECTED SUNLIGHT OR HIGH INTENSITY LIGHT BEMS IT IS RECOMMENDED TO USE THE OUTDOOR SENSOR S N DDITIONL TOOL TO SECURITY SYSTEM ND NOT FOR CTIVTING DIRECTLY LRM TOOLS S SOUNDERS ND PHONE DILLERS VOID TO ORIENT THE SENSOR TOWRDS MOVING OBJECTS SUCH S BUSHES, FLGS, BRNCHES ETC, IN ORDER TO VOID UNWNTED RELEVTION IN OUTDOOR INSTLLTION, IT IS RECOMMENDED TO USE THE SENSOR IN THE ND MODE FOR BEST IMMUNITY TO UNWNTED LRMS ND TO SET BOTH ELEMENTS IN THE SME DIRECTION. INCORRECT INSTLLTION COULD REDUCE SECURITY LEVEL. THE SENSOR DIRRVE HS N IP54 PROTECTION LEVEL GINST THE DUST ND WTER. IF POSSIBLE, IT IS NYWY RECOMMENDED TO VOID INSTLLING THE SENSOR IN RES DIRECTLY EXPOSED TO RIN OR SNOW. DO NOT SPRY NY HIGH PRESSURE WTER ON THE SENSOR. WHEN POSSIBLE INSTLL THE SENSOR IN SHELTERED RES OR MOUNT IT ON THE DEDICTED BRCKET (ST). TO HVE THE IP54 LEVEL IT IS MNDTORY TO INSERT THE O- RING INCLUDED IN THE PCKGE. IF YOU DO NOT COMPLY WITH THE BOVE MENTIONED RECCOMNDTIONS, IT MY CUSE NOT CORRECT WORKING OF THE SENSOR ND IN SUCH N EVENT, THE MNUFCTURER WILL DECLINE NY RESPONSIBILITY. DIRRVE-DIRFE V2.5 3

PROPER USE OF THE SENSOR DIRRVE/DIRFE sensor can be fixed at height between 80 and 250 cm from the ground level, on vertical surfaces, walls or posts using the fixing and protecting provided visor. Each detection unit is equipped with a Fresnel lens that builds 5 double sectors beams horizontally oriented with a radial aperture of 100 (Fig.1). Fig. 1 - View of the beam s sectors NOTICE The IR sensor is sensible to the amount of heat emitted by a moving body. The maximum range of the sensor (measured in meters) is referred to a human body. However the same amount of heat may be emitted by a smaller body at lower distances, or by a larger one at greater distances. It should be considered therefore that the range of any passive infrared sensor is a RELTIVE measure (referring to a human body) and NOT BSOLUTE (for any body). IR sensor Range (m) 4 DIRRVE-DIRFE V2.5

OUTDOOR USE The detecting units MUST be adjusted in order to have beams facing downward to the ground level or parallel to the ground, but NEVER upward. This is to avoid situations of blinding by sunlight during the day and to prevent the not-correct working of the sensor. The two detecting units MUST be adjusted on the vertical axis in order to the two beams pattern slight divergent: the upper unit see the most distant area, the lower one see the nearer area. In this way, using the ND logic, an alrm is triggered only when a human intruder crosses both the beams. The alarm is not triggered when only one beam is crossed for example by an animal or objects that you do not want to be considered intruders. NO LRM LRM NO LRM Fig. 2 - ND logic mode: the human trigger alarm, the dog doesn t. The function of "directional ND" allows to further refine the way in which an alarm is triggered. This mode make the sensor to trigger an alarm only after a sequence of detection that starts with the upper head (farther beams) and end, within the ND period, with the lower head (closest beams). This feature allows to give a directionality to the detection, that means the sensor is able to identify an intruder approaching the protected zone, avoiding alarms for people who, even if moving inside the detection zone of the upper head, are not approaching the protected zone. DIRRVE-DIRFE V2.5 5

NOTICE Take in consideration that small alterations of the head position corresponds to large modifications (at distance of 12 m) of the beams detecting zones. Consider that a 1 horizontal rotation of the head corresponds to a 20 cm shift of the beams at a distance of 12 m. It is then recommended to execute a very meticulous regulation and several tests in order to obtain the wanted result. To avoid unwanted alarms, NEVER adjust detecting heads allowing the beams to be parallel to the ground level. The beams should always finish against some surface (wall, ground) to have a well-defined detection area not pointing towards the open space (see Fig. 3). NEVER DJUST heads directly toward reflective surfaces, in order to prevent unwanted alarms. Typical examples of reflective surfaces are: windows, glass walls, water puddles, wet roads, smooth concrete surfaces, paved roads. The amount of reflection of these surfaces is not of course 100 %, however, if the heat source is very strong, reflection may be sufficient to trigger an alarm (see Fig. 4). 6 DIRRVE-DIRFE V2.5

OK NO!! Fig. 3 - void to have beams parallel to the ground level. NO!! Fig. 4 - void to have beams toward reflecting surfaces. DIRRVE-DIRFE V2.5 7

INDOOR USE The indoor installation allows greater flexibility of use, as sources of unwanted alarms are significantly reduced compared to the outdoor environment. In addition to the modes already described for the outdoor use, it is possible to adjust the detection heads also divergent in the horizontal plane. This allows to get different combinations of protection. For example it is possible to adjust heads forming a 90 angle in order to obtain a protected zone with semicircle shape, equivalent to that generated by 180 aperture lens. ccording to the selected logic (OR, ND, directional ND) you can have the sensor working in different ways. Lower head Upper head Top view (1) OR Logic The sensor gives alarm when it detects a movement in any of the areas covered by the two heads. Top view (2) ND Logic The sensor gives alarm only when it detects a movement crossing both the areas, not considering the direction. The movement inside only one area do not trigger an alarm. Top view (3) Directional ND Logic The sensor gives alarm only when it detects movement crossing from the upper head area to the lower one. DIP1=ON DIP1=OFF DIP3=OFF DIP1=OFF DIP3=ON 8 DIRRVE-DIRFE V2.5

INSTLLTION OF THE SENSOR Mount the sensor at height between 80 cm and 250 cm from the ground level. Position the sensor considering the coverage of an area with maximum distance of 12 m and radial aperture of 100 degrees. Device may not detect Device detects For a reliable and repeatable detection, it is recommended to install the sensor so that the intruder cross beams perpendicularly and not with a frontal approach. Once positioned the sensor, to adjust the heads, it is advisable to slightly untighten the screws of joints. Proceed with the "calibration" of the sensitivity of detections heads, starting with the minimum value of sensitivity (trimmer completely rotated counterclockwise) and the heads as downward as possible. Increase gradually sensitivity and orientation of the heads in order to obtain a detection only in the area that is to be protected and no alarms outside that area. Once finished the adjustment, tighten the screws of joints. NOTICE The external cover of the sensor causes an attenuation of about 30 % of the length of the beams. This should be considered during the setting operations. WRNING POWERING THE SENSOR WHILE THE TMPER JUMPERS RE CLOSED WILL DISBLE THE SUPERVISION CODE TRNSMISSION. THIS IS SIGNLED BY THE BLINKING OF THE BLUE LED (10 TIMES). THE SENSOR WILL BE CTIVE ND STBLE ONLY BOUT 20 S FTER THE RED LEDS STRT BLINKING. DIRRVE-DIRFE V2.5 9

PRTIL COVERING OF THE LENS In some environment the detection area of the heads can be too wide and be a potential source of problems if inside the area to be protected there are tree branches, curtains, windows, etc. Under these conditions it is possible to reduce the detection area by masking appropriately lateral or intermediate beams with adhesive tape placed over sectors of head lens (beams blinding), leaving it able to detect only the beams oriented towards stable zones of detection. This precaution avoids unwanted alarms raised by wind, moving branches, curtains or other objects present in the area. In the sensor package are included two plastic lens-covers to be applied to the detection heads in order to obtain a CURTIN EFFECT. With such a cover, the beam detection sector is reduced to 20, having the same detection range. The lens cover is to be inserted pressing it on the detection head as showed in following figures. Pay attention to correctly lock the two hook on the sides of the cover and that the lens cover is well fixed on the detection head. HED WITH CURTIN EFFECT LENS COVER VERIFY THT THE HOOKS RE WELL FIXED IN THEIR JOINT HED WITH STNDRD LENS 10 DIRRVE-DIRFE V2.5

WLL MOUNTING 1. Use the visor as mask to mark the position of holes on wall ( and B), then drill and insert provided dowels: 2. Insert the TMPER adjustment screw in dowel (B) leaving protrude its head about 9 10 mm from wall surface: B TMPER adjustment screw B 3. Overlap the visor to the detector: fine adjust TMPER screw so that fixing the detector, the tamper switch is well pressed without break circuit: bout 9 10 mm B TMPER adjustment Wall Visor TMPER protection headset Detector B DIRRVE-DIRFE V2.5 11

4. Fix detector and visor to wall (E points matching to holes) by the three appropriate screws, taking care to add BLCK o-rings on each and placing the RED o-ring in its appropriate position: Note for DIRFE version Before fix the detector to wall it is necessary to pass the cables through appropriate holes. Break one or more pre-marked hole-places (up to needs) on visor (C) and detector support platform (D): x 3 E Place here RED O-ring DIRFE detector Break septums for passing cables Visor E E 5. Insert the cover over detector platform starting from the top (hooking the two locking tabs). Fix (F) the cover by appropriate screw taking care to insert the BLCK o-ring: D C Pass cables through holes (C and D) and proceed with installation as follows. x 1 F F Cables path 12 DIRRVE-DIRFE V2.5

LYOUT ND SETTINGS TMPER LRM GND +12 V JUMPERS JP5 Wall Tamper Closed = tamper disabled Open = tamper enabled JP6 Cover Tamper Closed = tamper disabled Open = tamper enabled JP4 Testing Buzzer Closed = buzzer enabled (only when DIP4 ON) Open = buzzer disabled JP7 larm Led (BLUE) Closed = led enabled Open = led disabled RNGE TRIMMER R25 Upper head Trimmer to adjust the detection depth of the upper head. Turn clockwise to increase the detection range. R26 Lower head Trimmer to adjust the detection depth of the lower head. Turn clockwise to increase the detection range. DIRRVE-DIRFE V2.5 13

DIP1 Sensor Logic DIP2 IR sensitivity DIP3 ND-mode selection DIP4 Test DIP5 Continuous Transmission (DIRRVE MODEL) DIP6 (*) Continuous Detection (DIRRVE MODEL) DIP-SWITCH OFF = heads work with ND logic ON = heads work with OR logic OFF = HIGH sensitivity (for indoor use) ON = LOW sensitivity (for outdoor use) OFF = NORML ND larm is triggered with a detection that starts from any head and, within the ND time, ends by the detection of the other head. If during the ND time the second head doesn t detect anything, the sensor returns in stand-by mode. ON = DIRECTIONL ND larm is triggered only with a detection that starts from the upper head and, within the ND time, ends by the detection of the lower head. If during the ND time the lower head doesn t detect anything, the sensor returns in stand-by mode. OFF = Normal Operation (Test OFF) ON = Test Mode It enables the detection led of any head, the alarm led and the buzzer emission (if JP4 is closed), useful to test the coverage area. OFF = Normal Operation ON = Enables the wireless transmission once a second to test the maximum transmission range. OFF = Detection with quiet time larm is triggered only if occurs a time gap of more than 30 seconds (quiet time) from the last alarm. If within this time it is detected another movement, the sensor resets to zero the quiet time. If no movement is detected, after the quiet time the sensor is ready to trigger a new alarm. This function is particularly useful in very crowded places, to extend the battery life. ON = Continuous detection larm is triggered every time heads detect a movement. (*) NOTICE: When DIP6 is changed from OFF to ON, before to obtain a real change in working mode, it is mandatory to avoid the sensor to detect a movemen until the quiet time is ended, otherwise the sensor will continue to work as the DIP6 is in the OFF position. 14 DIRRVE-DIRFE V2.5

TECHNICL FETURES (DIRRVE wireless) POWER SUPPLY CONSUMPTION LOCL SIGNLLING LRM INPUTS TEST WIRELESS SECTION REMOTE SIGNLLING Battery 9 V Stand-by < 15 u LRM < 10 m 1 Led for upper head, 1 Led for lower head, 1 Led for alarm transmission 2 IR sensible elements, programmable with OR / ND logic Test function selectable by dipswitch with led display and buzzer TX 433,92 MHz (100 m range) TX alarm, tamper, low battery, supervision. TECHNICL FETURES (DIRFE wired) POWER SUPPLY 12 V CONSUMPTION Stand-by < 20 m LRM < 100 m LOCL SIGNLLING 1 Led for upper head, 1 Led for lower head, 1 Led for alarm transmission LRM INPUTS 2 IR sensible elements, programmable with OR / ND logic TEST Test function selectable by dipswitch with led display and buzzer OUTPUTS larm relay, Tamper. DIRRVE-DIRFE V2.5 15