MV Indoor Disconnectors

Similar documents
Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Unified requirements for systems with voltages above 1 kv up to 15 kv

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Low Voltage Switchboards The Best Technical Solution for Your Ship

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Transformer Bushings for GIS

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

Transmission Silicone Insulators Line Post 69 kv to 161 kv

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

R.C.C.B. s two-pole LEXIC

How To Build A Low Voltage Capacitor Lvcp

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

VD4. Vacuum circuit-breaker

HV glass suspension insulator U70BS and U70BL type Ball and socket type Standard profile

ABB Fuses Competitive Advantages

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Electronic overload relay EF65, EF96 and EF146

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

The power distribution board that sets new standards

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Distribution Boards & Consumer Units

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Low Voltage Products. Switches Automatic Transfer Switches

GE Power Controls. MiniFORM Switchboards

MNS is Switchgear System Technical Overview

MEDIUM VOLTAGE SWITCHGEAR CATALOGUE. Code: P2490_xx

Electronic overload relay EF19 and EF45

Pluggable interface relays CR-P Pcb relays

CAS 36 Ring Main Unit

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

DS 600. A contact free flux gate based current measurement sensor 600A rms

Medium voltage insulator

Sectionneur rotatif traversant d intérieur Wall bushing disconnector for indoor substation

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

Transformer oil cooler ALFA A02

Secondary Unit Substations

Tmax MCCBs. Molded case circuit breakers. Tmax

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

How To Choose A Transformer

E-STOP relays, safety gate monitors

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

OLI. Oil level indicator

Vario-Series Accessories

Switchboard system. NorLine 800

The standards mentioned in this document

ELECTROMAGNETIC DISC BRAKES

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

SIVACON The Versatile Low-Voltage Switchboard

Disconnectors and Earthing Switches 36 kv up to 800 kv

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Medium-voltage transformers

RY2 miniature industrial relays

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D MOOSBURG TEL FAX

AC-DC Converter Application Guidelines

ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Vacuum Circuit Breaker

The Intelligent AX1 Switchgear for Medium Voltage

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

Industrial Process Plants. Residential & Commercial Buildings. Roads & Tunnels. Airports & Seaports

ADM1TE 5/30A DIN rail single phase two wire energy meter

MEDIUM VOLTAGE SWITCHGEAR. DI-2, a modular concept combining all mediumvoltage

Transcription:

EFO Elektrik Malzemeleri San.ve Tic.Ltd.Şti. Tel : 232 376 83 05 (Pbx) Fax : 232 328 01 46 www.efoelektrik.com e mail:efo@efoelektrik.com MV Indoor Disconnectors IEC 62271 102

EFO indoor disconnectors are mechanical switches that,used in MV distribution systems for opening and closing of outdoor lines without current.they are producing according to IEC 60129 and IEC 62271-102 with ISO 9001 quality assurance system. EFO M.V outdoor disconnectors have TSE certificates. Technical and Constructional Features: - Type tests performed acc. to IEC 60129 and IEC 62271-102 - Frame is hot deep galvanized. - Porcelain and epoxy resin insulators are J type and creepage distance 12 mm/kv - Fix and moving terminals are made of electrolytic copper and silver plated so power lost minimized. - Disconnectors are delivered in wooden case with hand drive mechanism. - There are corrosion resistive materials used between frame and shafts. - There are double springs where fixed and moving terminals in touch so that contact resistances are minimized. - According to customers request earthing switches can be located outgoing or incoming side Rated voltage kv 36 / 24 / 17,5 / 12 Rated nominal current A 630 / 1250 / 2500 Rated frequency Hz 50 Number of poles pcs 3 Rated short-time withstand current ka 16 Rated duration of short-circuit s 1

TYPES Indoor Disconnector (DNA) Indoor Disconnector with Earhting Switch (DTA) On request earthing switch can be located outgoing or incoming side Indoor Disconnector with Fuse Base (DSA) Indoor Disconnector with Fuse Base and Earthing Switch (DSTA) On request earthing switch can be located outgoing or incoming side

Operating of indoor disconnector There is two way of operating; - Operating with manuel mechanism from front of panelboard - Operating from main shaft of disconnector Working with manual drive mechanism - This is used for operating from front of panelboard. - There can be coil (bobin) for electromagnetic lock.coil voltages can be 24VDC,48VDC,110VDC, 220VDC,220VAC. - Auxilary switches can be used for signal of disconnector positions. Auxilary switches 2NO+2NC or 4NO+4NC. Auxilary switches Back side Pipe welding rod Adjustable arm Front side Electromagnetic coil Frame Operating arm Fixing holes to panelboard

Disconnector closed position at MV panelboard Disconnector opened position at MV panelboard

Dimensions of indoor type manual drive mechanism (DKMN)

36kV,630A,Indoor Disconnector (DNA) Dimensions (mm) (Please contact us for other rated voltages and rated currents)

36kV,630A,Indoor Disconnector with Earthing Switch (DTA) Dimensions (mm) (Please contact us for other rated voltages and rated currents)

36kV,630A,Indoor Disconnector with Fuse Base (DSA) Dimensions (mm) (Please contact us for other rated voltages and rated currents)

36kV,630A,Indoor Disconnector with Fuse Base and Earthing Switch (DSTA) Dimensions (mm) (Please contact us for other rated voltages and rated currents