High-voltage fuse-links

Similar documents
ABB Fuses Competitive Advantages

CEF 9 CEF-S 23 CEF-VT 27 CMF 31 WBP 39 WBT 47 BPS 61

Protection from Short-circuit

Medium voltage products. Fuses

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

ISO 9001 : 2000 certified Copyright 2008 All rights are reserved

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

The complete range of consumer switchboards and switchgear

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Trip circuit supervision relay. Type RXTCS

Technical Data. back-up time in minutes 100% load % load

Secondary Unit Substations

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Type: DILM32 10(24V50HZ) Article No.:

8146/5 Series Breaker Panelboards

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Enhanced Quality with a Touch of Style

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Type: DILM9 10(24VDC) Article No.:

Medium voltage arc flash eliminator units VAM 3ED,

TORKEL 820 Battery Load Unit

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

High-Voltage Insulated DC/DC Power Supply ISO3116I for gate drivers for 4.5kV and 6.5kV IGBTs

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

ADM1TE 5/30A DIN rail single phase two wire energy meter

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

The standards mentioned in this document

How To Build A Low Voltage Capacitor Lvcp

Type: DILM50(230V50HZ,240V60HZ) Article No.:

CAS 36 Ring Main Unit

The Intelligent AX1 Switchgear for Medium Voltage

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

How To Make A Fronius Cl Power Inverter

SURGE PROTECTIVE DEVICES

GTEC transfer switch open transition

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

How To Choose A Transformer

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Rack mounted telephone- and leased line modem for industrial applications

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

Phase Modular Finally the benefits of Modular ups are for all

DS 600. A contact free flux gate based current measurement sensor 600A rms

Electric Vehicle Charging Solutions

Technical catalogue. Modular DIN rail components Installation contactors

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Remote Monitoring and REC 501 Control Unit Product Guide

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Assisted lift operated 2/2-way solenoid valves Type EV250B

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Contents. Description. Product Selection Guide

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Quick Connect. quick - simple - efficient.

5SV Residual Current Protective Devices

Technicaldata General

DEHNshield Application-optimised multipole combined lightning current and surge arrester

Goodsky Technical Data. Contact Details

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed

Auxiliary Relay. Type P8n, PQ8n, PN8n

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

Comparative study for cables and busbars

Safety automation solutions

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

ELECTROMAGNETIC DISC BRAKES

Fuse Selection Method Module 2. Date of the presentation

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

DS1 Diode-based transient-free capacitor switch

Cable Plug acc. to DIN EN , Form A

Solenoid valves 2/2-way direct-operated Type EV210A

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

MEDIUM VOLTAGE SWITCHGEAR CATALOGUE. Code: P2490_xx

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H, K-556H form A contact (normally open) for PCBs

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

a Nexans company Catalogue 2014

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Surge Protection for Photovoltaic Systems

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World

Medium Voltage Fuses. Fuse Links for use in Air, BS Type 3.6 ADGHC* BDGHC* BFGHD* BDGHC* BFGHD* AKGHD 76.

LM78XX Series Voltage Regulators

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Bimetallic Overload Relay Specifications

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Transcription:

EFO Elektrik Malzemeleri San.ve Tic.Ltd.Şti. 0 Sokak No. A.O.S.B. Çiğli / İZMİR Tel : 3 37 83 05 (Pbx) Fax : 3 38 01 www.efoelektrik.com e mail:efo@efoelektrik.com High-voltage fuse-links IEC 08 1 TS EN 08 1

0 Sokak No. İ.A.O.S.B. Çiğli / İZMİR / TÜRKİYE Tel : +90 3 37 83 05 (Pbx) Fax: +90 3 38 01 EFO High-voltage current limiting fuse-links are used as a protective devices of distribution lines, transformers,motor circuits and capacitors from thermal and dynamic effects of short circuits and over currents. Because of they are cheaper, simpler and much more reliable than alternative protecting systems, they used widely.they commonly form part of fuse-switch combination units,or in some cases they are used as stand-alone device to provide the sole protection of equipment.they have equal design for indoor and outdoor applications. EFO High-voltage current limiting fuse-links have high breaking capacity and back-up type. Back-up type fuses can break all currents from min. breaking currents (I3),to max. breaking currents (I1). Their striker system serves as an optical indicator and same time actuate a switching device or circuit breaker with its force. EFO High-voltage current limiting fuse-links are producing according to IEC 08-1 with ISO 9001 quality system. The most significant features of EFO High-voltage current limiting fuse-links - High breaking capacity which proved with type test - Reliable interruption of minimum breaking currents - Equal design for indoor and outdoor applications - Low temperature rise, because of low power dissipation - Low joule integral values - Reliable sealing for humidity and water - Reliable operation of striker mechanism - Low switching voltages at interruption - Melting elements resistant to aging - Production from 3, kv to 3 kv and A to 0A - Upon a request,fuse links can be supplied into no-standard dimensions.

0 Sokak No. İ.A.O.S.B. Çiğli / İZMİR / TÜRKİYE Tel : +90 3 37 83 05 (Pbx) Fax: +90 3 38 01 Cross-section starcore porcelain tube body contact cap striker system striker coil melting element quartz sand Dimensions Ø e Ø d ±1 Ø 5 ±1 3-1 L 3 ±1 ( dimensions in mm ) Striker pin max.3 Two different striker pin forces is avaliable; 80N(standart), N(on request) Also thermal striker pin is avaible. Inside of the thermal striker pin there is temperature sensitive element which reacts in case of temperature increasing of the fuse-link due to various reasons.thermal striker pin is convenient for the protection of the fuse enclosure of SF switchgears which requires additional protection features againgst inadmissible temperatures of certain switchgear parts.

0 Sokak No. İ.A.O.S.B. Çiğli / İZMİR / TÜRKİYE Tel : +90 3 37 83 05 (Pbx) Fax: +90 3 38 01 Dimensions Rated Voltage Rated Current Rated Maxsimum Breaking Current Rated Minimum Breaking Current Ød Øe L Cold Resistance Power Dissipation Weight Un (kv) In (A) I1 (ka) I3 (A) mm mm mm mω W kg 8 1 01 77 8 0 0 1 53 5 50 13 1,7 0 80 39 15 5 0 31 7, 50 9 31 0 1 37 50 00 1 0 3 5 11 3 80 0 75 78 7 51 3,1 0 00 5 15 500 1 0 85 88 3 13 3,8 8 995 5 1 7 7 5 9 0 1 1 1 53 5 8 19 1,7 0 80 5 0 5 3 1 50 9 3 0 3 57 50 00 5 3 5 19 5 80 0 75 78 1 78 3,1 0 00 5 15 500 7 150 0 85 88 5 05 3,8 8 158 8 1 91 3 8 1 5 05 5 1 7 53 5 138 8, 0 7 7 8 5 9 85 3 17,5 50 70 8 0 00 58 118 50 50 1 19 3 315 9 191 80 75 78 19 0, 0 00 1 15 500 11 0 0 85 88 9 70 5, 8 1890 17 1 13 35 85 1 0 01 9 1 53 5 19 7, 0 80 19 7 5 0 8 0 8 9 0 70 08 50 00 5 05 3 5 37 80 75 78 5 1, 0 00 18 3 15 500 1 0 85 88 11 380 5, 8 8 1 1 170 1 39 71 18 77 9 1 95 53 5 18,8 0 1 170 8 5 113 15 175 3 1 150 537 11 189 0 170 9 09 50 00 75 3 5 55 381 80 75 78 3 398 5, 0 00 17 15 500 0 0 0 85 88 1 5,9

0 Sokak No. İ.A.O.S.B. Çiğli / İZMİR / TÜRKİYE Tel : +90 3 37 83 05 (Pbx) Fax: +90 3 38 01 1 A A A A ms ms 00 sn 00 sn 00 sn 00 sn 0 sn 0 sn 0 sn 0 sn sn sn sn 1 05 0 50 3 80 0 15 A 0 A 0 A 0 A 0 A 00 A 00 A 00 A 00 A 000 A EFO ELEKTRİK MALZEMELERİ SAN. VE TİC. LTD. ŞTİ. Back - Up Fuse Time - Current characteristics 000 A 000 A 000 A 0000 A sn 00 ms 00 ms 00 ms 0 ms 0 ms 0 ms 0 ms CURRENT ms ms 1 ms TIME

0 Sokak No. İ.A.O.S.B. Çiğli / İZMİR / TÜRKİYE Tel : +90 3 37 83 05 (Pbx) Fax: +90 3 38 01 I0 (A) EFO ELEKTRIK MALZEMELERI SAN. VE TIC. LTD. STI. Cut - Off Current Characteristics For Back - Up Fuse Links Ip Ip In (A) 3 0 0 1 Cut - Off Current (peak) 3 1 1 3 Ip (A)

0 Sokak No. İ.A.O.S.B. Çiğli / İZMİR / TÜRKİYE Tel : +90 3 37 83 05 (Pbx) Fax: +90 3 38 01 Selection table of fuse for transformer protection for 7, kv Selection table of fuse for transformer protection for 1 kv Rated Current of Fuse (A) 1 0 5 0 50 3 80 0 15 Transformer Rated Capacity (kva) 50 0 50 00 800 00 150 0 Rated Current of Fuse (A) 1 0 5 0 50 3 80 0 15 Transformer Rated Capacity (kva) 50 0 50 00 800 00 150 0 Not : Till kva % Uk=,5, above kva % Uk= Not : Till kva % Uk=,5, above kva % Uk= Selection table of fuse for transformer protection for 17,5 kv Selection table of fuse for transformer protection for kv Rated Current of Fuse (A) Transformer Rated Capacity (kva) 50 0 50 00 800 00 150 0 Rated Current of Fuse (A) Transformer Rated Capacity (kva) 50 0 50 00 800 00 150 0 1 0 5 0 50 3 80 0 15 1 0 5 0 50 3 80 0 15 Not : Till kva % Uk=,5, above kva % Uk= Not : Till kva % Uk=,5, above kva % Uk= Selection table of fuse for transformer protection for 3 kv Rated Current of Fuse (A) 1 0 5 0 50 3 80 0 15 Transformer Rated Capacity (kva) 50 0 50 00 800 00 150 0 Not : Till kva % Uk=,5, above kva % Uk=

0 Sokak No. İ.A.O.S.B. Çiğli / İZMİR / TÜRKİYE Tel : +90 3 37 83 05 (Pbx) Fax: +90 3 38 01

0 Sokak No. İ.A.O.S.B. Çiğli / İZMİR / TÜRKİYE Tel : +90 3 37 83 05 (Pbx) Fax: +90 3 38 01

0 Sokak No. İ.A.O.S.B. Çiğli / İZMİR / TÜRKİYE Tel : +90 3 37 83 05 (Pbx) Fax: +90 3 38 01

0 Sokak No. İ.A.O.S.B. Çiğli / İZMİR / TÜRKİYE Tel : +90 3 37 83 05 (Pbx) Fax: +90 3 38 01