Breakers and Switches. Enclosed switches eot Enclosed disconnect switches Manual motor controllers

Similar documents
Breakers and Switches. Quick selection tool Accessories for switch-disconnectors and DC-switch-disconnectors

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM

Electronic overload relay EF19 and EF45

8146/5 Series Breaker Panelboards

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Electronic overload relay EF65, EF96 and EF146

Breakers and Switches. Switches Change-over, bypass and transfer switches

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire

Tmax MCCBs. Molded case circuit breakers. Tmax

MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved

SPEEDFAX TM 2011 Disconnect Switches Contents

Series 8146/5-V37 and Series 8150/5-V37

Rotary Disconnect Switch Specifications

Low Voltage Products. Switches Automatic Transfer Switches

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

OTM_F_C_. Installation instruction 34OTM_F_C_ / 1SCC303009M0201

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Three-phase monitoring relay CM-PFE

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

ZS25 Screw Clamp Terminal Blocks Feed-through

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Manual motor starter MS116

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Contractors Guide Central Inverter System Installation

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

PSR The compact range Description

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

LIEBERT VNSA Installation Sheet

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Analog signal converters CC-E I/I Current / current isolators

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Catalogue May EasyLine XLP Fuse Switch Disconnector pole

FUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue SOCOMEC. Fuse combination switches

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

INSTALLATION INSTRUCTIONS

How To Drive A Compact Serie 1

R.C.C.B. s two-pole LEXIC

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Class 58 Drum Controller Catalog & Price List November 2015, Replaces Jan 2015

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Electric Rotary Actuator - On/Off or programmable control actuator

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

EDS / EFS Series Control Stations

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Catalog. Modular DIN rail components Installation contactors

Plugs and Receptacles

MCR1900 Media Converter 19-Slot Chassis

IRRIGATION PUMPING Table of Contents - Section 900

Switches for photovoltaic applications Switch-disconnectors OTDC and OTDCP

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

IEC 309 INTERLOCKS NORTH AMERICAN

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

Catalog January. Heavy industrial power applications Motor contactors and starters

Circuit Breakers. Next Generation of Protection Capabilities

Owner's/Installation Manual

AdvAntAge SerieS Switch-rAted iec Pin And Sleeve

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Self Monitoring Power Supply (BPSM)

RAY-MAX Integrated Solar Power Strip

Plug and Socket Devices CES 63 A Series 8579

Distribution Boards & Consumer Units

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

FLB Series Circuit Breakers and Enclosures

Type K current limiting fuse canister Technical information and installation guide

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

ASCO SERIES 185 Power Transfer Switches

The complete range of consumer switchboards and switchgear

Type: DILM32 10(24V50HZ) Article No.:

Products and solutions for lifting systems

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Speed Control Relays SX2

Rugged & Reliable Power Connections

38 Series - Relay interface modules A

Bulletin 1489 Circuit Breakers. Selection Guide

Selection Guide. Bulletin 194R/140U External Operating Handles

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Transcription:

Breakers and Switches Enclosed switches eot Enclosed disconnect switches Manual motor controllers

The next generation of enclosed switches General information The eot series of enclosed manual motor controllers are rotary operated, 3 pole, 600V Hp rated switches, housed in thermoplastic/polycarbonate or sheet steel enclosures. They are suitable for wet and corrosive environments. Disconnect means Short Circuit protective device Plastic enclosed manual motor controllers UL/NEMA 3R/12 and NEMA 4X versions Standard black handle, selector or pistol type Steel sheet enclosed switches UL/NEMA 3R/12 versions Standard black handle, selector or pistol type M Controller Overload protections Motor disconnect (OSHA Lock Out/Tag Out) eot products are properly installed on the load side of a branch circuit protective device and are suitable for use as motor disconnects as illustrated in Figure. 2 1SCC340011C0201 Enclosed switches eot

Cutting edge design and technology. eot ensures reliable switching time after time. Outstanding features cul approval, UL508 Listed, UL98 Suitable as motor disconnect Horsepower rated Touch safe construction Positive operation Clear position indication Self lifting tunnel terminals Extremely compact size Accessories 4th power pole Snap-on auxiliary contacts Clean and simple installation Plastic enclosures have conduit knockouts provided on the top and bottom of the enclosure. Plastic enclosures have a metallic base plate that electrically bonds together all conduit hubs installed in the top and bottom of the enclosure - additional conduit bonding jumpers are not required. Plastic enclosure installs flush on mounting surface, reducing the accumulation of dirt behind the enclosure. Sealed enclosure cover is water tight, suitable for hose-down environments (Type 4X version only). Enclosed switches eot 1SCC340011C0201 3

Technical data Enclosed switches Technical data eot16 eot32 eot45 eot63 Approvals 3pole UL508 UL508 UL508 UL508 UL Amperage Rating 16 40 60 80 Max Horsepower rating Three Phase 200V-208V HP 3 10 15 20 240V HP 6 10 15 20 480V HP 10 20 30 40 600V HP 10 25 30 40 Single Phase 120V HP 1 2 2 2 240V HP 2 5 7.5 10 Interrupting Capacity (SCCR) with fuse Fuse Type CC ka 10/- 10/- -/- -/- Fuse Type J ka 10/10 10/10 100/- 100/- Fuse Type T ka 10/10 10/10 100/- 100/- Fuse Type RK1 ka 10/- 10/- -/- -/- Fuse Type RK5 ka 5/5 5/5 10/5 10/5 Fuse Type L ka -/- -/- -/- -/- Fuse Type H ka -/- -/- -/5 -/5 Maximum Fuse Size A 30/60 1) 30/60 1) 100/150 100/150 Endurances Min. electrical endurance power factor 0.75...0.8 op. cycles 6000 6000 6000 6000 0.40...0.50 op. cycles 1000 1000 1000 1000 Mechanical endurance operations 20000 20000 20000 20000 Switch operating torque lbs. in. 8.8 8.8 10.5 10.5 Nm 1 1 1.2 1.2 Knock-outs Plastic enclosure Ends 4 1/2 or 4 3/4 4 1/2" or 4 3/4" 4 3/4" or 4 1" 4 1" or 4 1 1/4" Terminal Lug Kits Not required Not required Not required Not required Wire Range AWG #18-8 #18-8 #14-4 #14-4 mm 2 0.75-6 0.75-6 2.5-16 2.5-16 Wire Tightening Torque lbs. in. 7 7 18 18 Nm 0.8 0.8 2.0 2.0 Lug Mounting lbs. in. Integral Integral Integral Integral Auxiliary Contacts Suitable auxiliary contacts Plastic enclosure OA1G_ or OA2G11 OA1G_ or OA2G11 OA1G_ or OA2G11 OA1G_ or OA2G11 Metallic enclosure OA1G_ OA1G_ OA1G_ OA1G_ NEMA ratings, AC AC600 AC600 AC600 AC600 AC rated voltage VAC 600 600 600 600 AC rated thermal current A 10 10 10 10 AC maximum volt-ampere making VAC 7200 7200 7200 7200 AC maximum volt-amperage breaking VAC 720 720 720 720 NEMA ratings, DC R300 R300 R300 R300 DC rated voltage VDC 300 300 300 300 DC thermal rated current A 1 1 1 1 DC maximum make-break VA 28 28 28 28 Torque: wire tightening lbs. in. 7 7 7 7 Nm 0.8 0.8 0.8 0.8 Wire Range AWG #18-14 #18-14 #18-14 #18-14 mm 2 0.75-2.5 0.75-2.5 0.75-2.5 0.75-2.5 1) Fuse size 70A for RK5 4 1SCC340011C0201 Enclosed switches eot

Ordering information Enclosed manual motor controllers EOT16/32_-S EOT45_-S Plastic enclosed 3-pole manual motor contollers Amp Weight/ rating Handle Handle Auxiliary* unit [A] type color contacts Catalog number Order number [kg] UL/NEMA 3R, 12 16 Selector Black - EOT16U3P3-S 1SCA022792R2700 0.55 40 Selector Black - EOT32U3P3-S 1SCA022793R3060 0.55 60 Selector Black - EOT45U3P3-S 1SCA103984R1001 1.10 80 Pistol Black - EOT63U3P3-P 1SCA103999R1001 2.11 UL/NEMA 4X 16 Pistol Black - EOT16U3P4-P 1SCA022793R4030 0.62 40 Pistol Black - EOT32U3P4-P 1SCA022793R3810 0.62 * Types with auxiliary contacts available on request EOT63_-P Sheet steel enclosed 3-pole manual motor contollers Amp Weight/ rating Handle Handle Auxiliary unit [A] type color contacts* Catalog number Order number [kg] UL/NEMA 3R, 12 40 Selector Black - EOT32U3M3-S 1SCA022823R7440 2.1 60 Pistol Black - EOT45U3M3-P 1SCA022823R8840 2.8 80 Pistol Black - EOT63U3M3-P 1SCA022823R9060 2.8 * Types with auxiliary contacts available on request EOT16/32_-P EOT32U3M3-S EOT45/63U3M3-P Enclosed switches eot 1SCC340011C0201 5

Ordering information Accessories OA1G S00261A Auxiliary contacts Contact numbering according to EN 50013. AC thermal amp rating 10 A and AC rated voltage 600 V. IP20 touch safe. The catalog numbers are for one piece. Maximum number of auxiliary contacts: 2NO+2NC, if fourth pole installed: 1NO+2NC. OA2G11 suitable only for plastic enclosed disconnect switches, not mountable on same side as the fourth pole. S01025A Weight/ Mounting to the side unit Function of the switch Catalog number Order number [kg] 1NC left OA1G01 1SCA022353R4890 0.03 1NO right OA1G10 1SCA022353R4970 0.03 1NO+1NC right OA2G11 1SCA022379R8100 0.03 OA2G Fourth poles Mountable on the side of the switch. Only one additional pole per switch. AC rated voltage 600 V. IP20 touch safe. The catalog numbers are for one piece. OTP_40_ OTP_80_ S00262A S00263A AC thermal Weight/ Suitable for amp rating unit switches [A] Catalog number Order number [kg] Simultaneous function with the main contacts EOT16, EOT32 40 OTPS40FPN2 1SCA105000R1001 0.03 EOT45, EOT63 80 OTPS80FP 1SCA105461R1001 0.06 Late-break and early-make EOT16, EOT32 40 OTPL40FP 1SCA105717R1001 0.03 EOT45, EOT63 80 OTPL80FP 1SCA105452R1001 0.06 Solid neutral pole EOT16, EOT32 40 OTPN40FP 1SCA104997R1001 0.03 EOT45, EOT63 80 OTPN80FP 1SCA105457R1001 0.06 6 1SCC340011C0201 Enclosed switches eot

Ordering information Accessories Handles OHBS2AJ Selector type handles NEMA 1, 3R, 12 (IP65), handles, padlockable with maximum 3 padlocks with bail diameter 0.20 0.32" (5...8 mm), door interlock in ON-position, defeatable. Indication I-O and ON-OFF. Weight/ unit Color Catalog number Order number [kg] For shaft diameter 0.24 0.24 (6 mm). Black OHBS2AJ 1SCA105213R1001 OHB65J6 Pistol type handles, plastic NEMA 1,3R, 12, 4, 4X (IP65) handles, padlockable with maximum 3 padlocks with bail diameter 0.20 0.39" (5 10 mm) in OFF-position, door interlock in ON-position. Screw fixing from the back side of the handle. No screws on the front ensures double insulation. Indication I-O, ON-OFF. Handle Weight/ length unit Color [in/mm] Catalog number Order number [kg] Black 2.6/65 OHB65L6 1SCA022580R9650 0.12 Enclosed switches eot 1SCC340011C0201 7

O OFF Dimension drawings Plastic enclosed manual motor controllers eot16_-s/p, eot32_-s/p mm in S07152 / M00084 EOT16-32U_P_-S A 76 2,99 140 5,51 152 5,98 161,4 6,35 50 1,97 I ON 100 3,94 4,5 0,18 R2,25 0,09 7,40 0,29 30 1,18 Metric M20 (0,79 dia) 20 0,79 34,5 1,36 115,5 4,55 Selector type handle 19 0,75 30 1,18 Metric M20 (0,79 dia) 20 0,79 45 126 1,77 4,96 Pistol type handle 36 1,42 152 5,98 3/4 " 1/2 " M25 24 0,94 50 25 1,97 0,98 Knock-outs on top and bottom eot45_-s 8 1SCC340011C0201 Enclosed switches eot

Dimension drawings Plastic enclosed manual motor controllers eot63_-p mm in 300 11.81 150 5.91 210 8.27 189 7.44 60 2.36 20.5 0.81 20 0.79 189 7.44 238 9.37 238 9.37 M00141/EOT30-100U_P_-P C Ø6.6 0.26 105 4.13 136 5.35 181 7.12 45 1.77 1" 1 1/4" 1" 1 1/4" Enclosed switches eot 1SCC340011C0201 9

O OFF Dimension drawings Sheet steel and stainless steel enclosed manual motor controllers eot32_s mm in A 19 0,75 Type 3R, 4X, 12 M00102 / EOT16-32M/S-S B B C D E F G I ON K I L H J P O eot32 Dimension [mm/in] A B C D E F G H I J K L M N O P 7,9/0,31 215,9/8,50 183,4/7,22 91,7/3,61 73,7/2,90 101,6/4,00 134,1/5,28 19,0/0,75 83,3/3,28 35,5/1,36 2,8/0,11 117,9/4,64 101,6/4,0 101,6/4,0 196,9/7,75 76,2/3,00 eot45/63_-p mm in A 19 0,75 Type 3R, 4X, 12 D M00101 / EOT16-32M/S-P B B C E F G K I L J H P O eot45-63 Dimension [mm/in] Handle code A B C D E F G H I J K L M N O P -P 7,9/0,31 241,3/9,50 208,8/8,22 104,4/4,11 86,1/3,39 127,0/5,00 159,5/6,28 36,0/1,42 108,7/4,28 45,0/1,77 2,8/0,11 153,7/6,05 127,0/5,0 127,0/5,0 222,3/8,75 101,6/4,00 -M 7,9/0,31 241,3/9,50 208,8/8,22 104,4/4,11 86,1/3,39 127,0/5,00 159,5/6,28 36,0/1,42 108,7/4,28 52,0/2,05 2,8/0,11 160,7/6,32 127,0/5,0 127,0/5,0 222,3/8,75 101,6/4,00 10 1SCC340011C0201 Enclosed switches eot

Contact us ABB Oy Breakers and Switches P.O. Box 622 FI-65101 Vaasa, Finland Phone: +358 10 22 11 Fax: +358 10 22 45708 E-Mail: firstname.surname@fi.abb.com www.abb.com You can find the address of your local sales organisation on the ABB homepage: www.abb.com/contacts > Low Voltage Products and Systems Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2014 ABB All rights reserved Copyright ABB. Catalogue OT10EU 14-02 1SCC340011C0201