Compliance Guide 2009 IFC/IBC 1024 LUMINOUS EGRESS PATH MARKINGS General Markings within exit enclosures

Similar documents
Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

COMMONLY USED RESIDENTIAL BUILDING CODES


New Ontario Building Code Highlights

* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.

Walking and Working Surface Checklist:

The replacement or modification of existing windows shall comply with the following requirements:

Number of Sides Required to Have a Handrail

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

BUILDING PERMIT SPECIFICATIONS

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

FIRE AND LIFE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS

Residential Decks. Planning and Development Services Department

MEANS OF EGRESS CHAPTER 10

CITY OF TORONTO. BY-LAW No

MEANS OF EGRESS CHAPTER 10

MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal

Simplified Steel Stair Design for Commercial and Institutional Buildings

MEANS OF EGRESS CHAPTER 10

MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST

Mobile Home Pre-Inspection Checklist

FIRE SAFETY INSPECTION REPORT

2.9 WINDOW & DOOR BUCKS

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

Errata has been identified as follows:

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau

SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST

MEANS OF EGRESS CHAPTER 10

The emergency provisions affect the following Building Code sections:

City of Riverside Building & Safety Division Phone: (951)

New York City Department of Buildings

17,280 square feet Overview:


Single Family Residential Basement Finish

OCFRD TENT STANDARD This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

Section 7: Elevators and Lifts. Main Entry Floor Outside the Elevator

CHAPTER 10 MEANS OF EGRESS. User Note: See Preface page iv ("marginal markings" for Chapter 10 reorganization information.)

Classroom Door Security & Locking Hardware

MEANS OF EGRESS CHAPTER 10

Base Cabinet with Self-storing Folding Doors and Floor

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

Chapter 3 Installing Over-the-Post Railing on an L-Shaped Stair

ADA POST INSPECTION CHECKLIST. Job No. Route County Location

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

Summary of Preliminary Assessment on Structural, Fire and Electrical Safety

ELECTRONIC HEALTH RECORDS AND WRITING SURFACES

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

PUBLIC RESTROOMS, DESIGN INTENT

Solving Geometric Applications

DE Frame with C Series Sidelight

The Commonwealth of Massachusetts Executive Office of Public Safety Department of Fire Services

2010 FLORIDA BUILDNG CODE, FIRE AND LIFE SAFETY i

Automatic Door Selection Guide

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

Healthcare Engineering. Code Summary Report

THIRD LAGUNA HILLS MUTUAL

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

PART 1 GENERAL 1.1 SECTION INCLUDES

19 DYNAmax Free Standing Server C A B I N E T s

New York City Department of Buildings

Uncovered Decks & Porches

AUSTRALIAN HUMAN RIGHTS COMMISSION NOTICE OF DECISION ON APPLICATION FOR TEMPORARY EXEMPTIONS: AUSTRALASIAN RAILWAY ASSOCIATION

Basic Fire Door Requirements

Reduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U

Stair Parts Installation. Tricks

Window Installation Instructions

Residential Deck Safety, Construction, and Repair

glass & Glazing Products

House Design Tutorial

Building Code Clarifications - 7. Fire Resistance

Bath Planning Guidelines With Access Standards

CHAPTER 9 FIRE PROTECTION SYSTEMS

TENTS, CANOPIES AND OTHER MEMBRANE STRUCTURES

Charter Township of Shelby Harry Reese Building Director

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

FIRE-RESISTANCE-RATED CONSTRUCTION

Wren Kitchens Installation Tips Carefully check your kitchen delivery Measuring out and marking up Fitting the base cabinets...

How To Protect A Swimming Pool

Town House Center Highway North Huntingdon, PA 15642

19 DYNAmax Free Standing Server C A B I N E T s

How To Build A Basement House

Building Regulations (Northern Ireland) Department of Finance and Personnel protection from impact.

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER May 2015

Transcription:

Compliance Guide 2009 IFC/IBC 1024 LUMINOUS EGRESS PATH MARKINGS 1024.1 General Approved luminous egress path markings delineating the exit path shall be provided in buildings of Groups A, B, E, I, M and R-1 having occupied floors located more than 75 feet (22 860 mm) above the lowest level of fire department vehicle access in accordance with Sections 1024.1 through 1024.5. Applicable Occupancy Groups: A - Assembly B - Business E - Educational R1 - Transient Residential I - Institutional M - Mercantile 1024.2 Markings within exit enclosures Egress path markings shall be provided in exit enclosures, including vertical exit enclosures and exit passageways, in accordance with Sections 1024.2.1 through 1024.2.6. 1024.2.1 Steps A solid and continuous stripe shall be applied to the horizontal leading edge of each step and shall extend for the full length of the step. Outlining stripes shall have a minimum horizontal width of 1 inch (25 mm) and a maximum width of 2 inches (51 mm). The leading edge of the stripe shall be placed at a maximum of 1 / 2 inch (12.7 mm) from the leading edge of the step and the stripe shall overlap the leading edge of the step by not more than 1 / 2 inch (12.7 mm) down the vertical face of the step. 1024.2.1 Steps 1024.2.2 Landings E Series Photoluminescent contrast strips F / RF Series Flat aluminum stair nosings with photoluminescent contrast strips S Series Cast-in-place aluminum stair nosings with photoluminescent contrast strips Exception: The minimum width of 1 inch (25 mm) shall not apply to outlining stripes listed in accordance with UL 1994. 1/6

1024.2.2 Landings The leading edge of landings shall be marked with a stripe consistent with the dimensional requirements for steps. 1024.2.3 Handrails All handrails and handrail extensions shall be marked with a solid and continuous stripe having a minimum width of 1 inch (25 mm). The stripe shall be placed on the top surface of the handrail for the entire length of the handrail, including extensions and newel post caps. Where handrails or handrail extensions bend or turn corners, the stripe shall not have a gap of more than 4 inches (102 mm). 1024.2.3 Handrails H Series Handrail strip and end caps Exception: The minimum width of 1 inch (25 mm) shall not apply to outlining stripes listed in accordance with UL 1994. 1024.2.4 Perimeter demarcation lines Stair landings and other floor areas within exit enclosures, with the exception of the sides of steps, shall be provided with solid and continuous demarcation lines on the floor or on the walls or a combination of both. The stripes shall be 1 to 2 inches (25 mm to 51 mm) wide with interruptions not exceeding 4 inches (102 mm). 1024.2.4 Perimeter demarcation lines T5-G3001 / T8-6001 Aluminum track and photoluminescent guidance strip Exception: The minimum width of 1 inch (25 mm) shall not apply to outlining stripes listed in accordance with UL 1994. 1024.2.4.1 Floor-mounted demarcation lines Perimeter demarcation lines shall be placed within 4 inches (102 mm) of the wall and shall extend to within 2 inches (51 mm) of the markings on the leading edge of landings. The demarcation lines shall continue across the floor in front of all doors. 2/6

Exception: Demarcation lines shall not extend in front of exit doors that lead out of an exit enclosure and through which occupants must travel to complete the exit path. 1024.2.4.2 Wall-mounted demarcation lines Perimeter demarcation lines shall be placed on the wall with the bottom edge of the stripe no more than 4 inches (102 mm) above the finished floor. At the top or bottom of the stairs, demarcation lines shall drop vertically to the floor within 2 inches (51 mm) of the step or landing edge. Demarcation lines on walls shall transition vertically to the floor and then extend across the floor where a line on the floor is the only practical method of outlining the path. Where the wall line is broken by a door, demarcation lines on walls shall continue across the face of the door or transition to the floor and extend across the floor in front of such door. Exception: Demarcation lines shall not extend in front of exit doors that lead out of an exit enclosure and through which occupants must travel to complete the exit path. 1024.2.4.3 Transition Where a wall-mounted demarcation line transitions to a floor-mounted demarcation line, or vice versa, the wall-mounted demarcation line shall drop vertically to the floor to meet a complementary extension of the floor-mounted demarcation line, thus forming a continuous marking. 1024.2.5 Obstacles Obstacles at or below 6 feet 6 inches (1981 mm) in height and projecting more than 4 inches (102 mm) into the egress path shall be outlined with markings no less than 1 inch (25 mm) in width comprised of a pattern of 1024.2.5 Obstacles OB20025 Photoluminescent obstruction strip OB20025-TP Photoluminescent obstruction tape alternating equal bands, of luminescent luminous material and black, with the alternating bands no more than 2 inches (51 mm) thick and angled at 45 degrees (0.79 rad). Obstacles shall include, but are not limited to, standpipes, hose cabinets, wall projections and restricted height areas. However, such markings shall not conceal any required information or indicators including, but not limited to, instructions to occupants for the use of standpipes. 3/6

1024.2.6 Doors from exit enclosures Doors through which occupants within an exit enclosure must pass in order to complete the exit path shall be provided with markings complying with Sections 1024.2.6.1 through 1024.2.6.3. 1024.2.6.1 Emergency exit symbol The doors shall be identified by a low-location luminous emergency exit symbol complying with NFPA 170. The exit symbol shall be a minimum of 4 inches (102 mm) in height and shall be mounted on the door, centered horizontally, with the top of the symbol no higher than 18 inches (457 mm) above the finished floor. 1024.2.6.1 Emergency exit symbol R Series Running man photoluminescent directional and door exit signs 1024.2.6.2 Door hardware markings Door hardware shall be marked with no less than 16 square inches (406 mm 2 ) of luminous material. This marking shall be located behind, immediately adjacent to or on the door handle and/or escutcheon. Where a panic bar is installed, such 1024.2.6.2 Door hardware markings DHM Series Door hardware indicators material shall be no less than 1 inch (25 mm) wide for the entire length of the actuating bar or touchpad. 1024.2.6.3 Door frame markings The top and sides of the door frame shall be marked with a solid and continuous 1 inch to 2 inch (25 mm to 51 mm) wide stripe. Where the door molding does not provide sufficient flat surface on which to locate the stripe, the stripe shall be permitted to be located on the wall surrounding the frame. 1024.2.6.3 Door frame markings G6001 1024.3 Uniformity Placement and dimensions of markings shall be consistent and uniform throughout the same exit enclosure. 4/6

1024.4 Self-luminous and photoluminescent Luminous egress path markings shall be permitted to be made of any material, including paint, provided that an electrical charge is not required to maintain the required luminance. Such materials shall include, but are not limited to, self-luminous materials and photoluminescent materials. Materials shall comply with either: 1. UL 1994; or 2. ASTM E 2072, except that the charging source shall be 1 footcandle (11 lux) of fluorescent illumination for 60 minutes, and the minimum luminance shall be 30 millicandelas per square meter at 10 minutes and 5 millicandelas per square meter after 90 minutes. 1024.4 Self-luminous and photoluminescent All components UL 1994 listed and/or ASTM E 2072 compliant 1024.5 Illumination Exit enclosures where photoluminescent exit path markings are installed shall be provided with the minimum means of egress illumination required by Section 1006 for at least 60 minutes prior to periods when the building is occupied. 5/6

COMPLIANCE QUICK REFERENCE 2009 IFC/IBC 1024 Luminous Egress Path Markings 1024.2.1 Steps - 1024.2.2 Landings E Series Photoluminescent contrast strips F / RF Series Flat aluminum stair nosings with photoluminescent contrast strips S Series Cast-in-place aluminum stair nosings with photoluminescent contrast strips Applicable Occupancy Groups: A - Assembly B - Business E - Educational R1 - Transient Residential I - Institutional M - Mercantile 1024.2.3 Handrails H Series Handrail strip and end caps 1024.2.4 Perimeter demarcation lines T5-G3001 / T8-6001 Aluminum track and photoluminescent guidance strip 1024.2.5 Obstacles OB20025 Photoluminescent obstruction strip OB20025-TP Photoluminescent obstruction tape 1024.2.6.1 Emergency exit symbol R Series Running man photoluminescent directional and door exit signs 1024.2.6.2 Door hardware markings DHM Series Door hardware indicators 1024.2.6.3 Door frame markings G6001 1024.4 Self-luminous and photoluminescent All components UL 1994 listed and/or ASTM E 2072 compliant 6/6