Ethernet based multichannel audio system for public address, music and broadcast applications

Similar documents
ETHERNET based public address and voice alarm system

T Zone Weekly Timer

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

EN54-16 Voice Alarm System PRODUCT DATASHEETS

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

MANUAL PC1000R

Plena Voice Alarm System. Software Manual Configuration Software

Praesideo - Digital Public Address and Emergency Sound System

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Contents. Connection Guide. What is Dante? Connections Network Set Up System Examples Copyright 2015 ROLAND CORPORATION

HCS-3600MB2 Conference Main Unit

Safety Warnings and Guidelines

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

SMS GSM Alarm Messenger

SNMP Web Management. User s Manual For SNMP Web Card/Box

Disturbance Recoder SPCR 8C27. Product Guide

TI 313 (1.0 EN) d&b Remote network - Integration

Voice Alarm System LOCAL & GLOBAL

DVI KVM Switches DP-MUX 7.4

HARTING mcon 1000 Introduction and features

Temperature & Humidity SMS Alert Controller

User Manual. Please read this manual carefully before using the Phoenix Octopus

DATA SHEET TESirAFOrTÉ Ai TESirAFOrTÉ AVB Ai

VM-3000 Series. With new features! Integrated Voice Evacuation System. sound without compromise.

PLENA matrix Digital Sound System Surprisingly Flexible. Powerful Control.

HomePlug adapters for transferring music and speech over your household power circuit

Soundcraft Vi Series MADI Fundamentals

NC-12 Modbus Application

IMPORTANT SAFETY INSTRUCTIONS

Plena Voice Alarm System. Installation and Operation manual

PowerGem Pro Uninterruptible Power Supply

Remote Sources. Facility. Router

Zone Mixer. 6 channels configurable from 24 inputs. 3 zone outputs. Expandable via Sys-Link TM Built-in comp/limiter, ducking and alarm functions

Notice. Reverse engineering and disassembly are prohibited.

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP!

3500/22M Transient Data Interface

Mbox Basics Guide. Version 6.7 for LE Systems on Windows XP or Mac OS X. Digidesign

How To Sell A Talan

BRIDGEWAY MOBILE VOIP RADIO-INTERCOM GATEWAY

AXIS 211A Network Camera

A-307. Mobile Data Terminal. Android OS Platform Datasheet

SESSION ACOUSTIC DI USER S GUIDE

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Voice alarm system E100 the new standard for safe evacuation

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

Co-designed by TASCAM and

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

Repeaters and Mimics Data Sheet

Features, Benefits, and Operation

SD Rack. DiGiCo SD Rack. User Manual B - August

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

Solutions for Mass Notification Systems

1 All safety instructions, warnings and operating instructions must be read first.

Product Information Fire alarm panel 8000 C

BridgeWay Fixed Base Radio Telecom VoIP Gateway

HDCATS-100. Installation Guide

AXIS 262+ Network Video Recorder

BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION

FIREDEX Conventional Fire Panels

Power Feeding Equipment for Optical Submarine Cable Systems

Permissible ambient temperature Operation Storage, transport

Starlink 9003T1 T1/E1 Dig i tal Trans mis sion Sys tem

IP Intercom System. Classroom intercom system for two-way voice communications, help desk support, and security/status monitoring.

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

a reliable choice to go on-air

MICROSENS. Installation Switch with PoE (5x10/100Base-TX) and fiber uplink (1x100Base-FX) General. Features

User Manual. EtherUSB

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

DS-7208HVI-ST Series DVR. Technical Manual

The completely Ethernet-based. protocol enables several imode devices to be linked, using easily-sourced. cables and components.

CLASS D POWER AMPLIFIERS

NGSS Data Consolidator (DC)

Netlog. Network Audio Logger. June catalogue. Manufacturers of audio & video products for radio & TV broadcasters

Uninterruptible Power Supply

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

40 Watt Mixer Amplifier Owners Manual with Media Player

Megapixel IP66. IP66 Waterproof Housing, Cable through bracket and Anti-Fog Front Cover

Plena Two-zone Call Station. Installation and User Instructions PLE-2CS

Public Address and Voice Alarm

QUALITY AV PRODUCTS INMATE/INMATE USB PROFESSIONAL 19" MIXER. User Guide and Reference Manual

ECD 2 High Performance Balanced DAC. 24 Bit /192kHz. Owner's Manual

DR-1 Portable Digital Recorder OWNER'S MANUAL

DS-7608NI-S Series NVR. Technical Manual

C24-CAMANL Video Server/Encoder

MN3310 Evaluation Kit v1 User Guide

TELECOM HF VHF UHF over IP

Stunning sound and revolutionary intelligence to analyze and correct the problems in any room.

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

IP Intercom System

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

Understanding the DriveRack PA. The diagram below shows the DriveRack PA in the signal chain of a typical sound system.

LwLVision-USB 2.0. Installation Guide

Transcription:

Ethernet based multichannel audio system for public address, music and broadcast applications 64 channels/48khz/24bit/1.33ms

System data Ethernet based multichannel audio system for public address, music emergency and broadcast applications Simultaneous transmission of up to 64 digital audio channels in studio quality (48 khz / 24 bit), with a constant latency period of 1.33 ms (digital) Distributed audio system no single point of failure Real-time configuration with ITEC NET - NET DESIGN: Allows system configuration changes during normal operation of the system Real-time audio transmission: Constant latency of 4.6 ms analog-in/analog-out Up to 4000 devices can work simultaneously together in a network Up to 16,000 output zones in one audio network Can also be used with standard Ethernet network components Integrated 2 GB memory card for alarm texts and music files Recording Capacity 256 files, total time about 3 hours! Integrated real-time recorder for delayed announcements Speaker impedance and line monitoring during program mode ITEC NET application interface (TCP / IP) for connecting to security management systems It has never been so easy to plan complex audio systems System components in certification according to EN 54-16 ITEC NET DESIGN configuration software 2

Channel A Channel B 24V DC Fault Clip Fault 230V AC Operating mode Signal Operating mode 24V DC 230V AC Channel A Fault Clip Operating mode Signal Channel C Fault Clip Operating mode Signal Channel B Fault Operating mode Clip Signal Clip Signal Channel D Fault Clip Operating mode Signal DIGI POWER 2x250T DIGI POWER 4x150T Contents System Overview Page 4 Spider44 Page 6 SpiderMike2 Page 8 Fire fighters callstation Page 10 Switch 4/1 Page 11 Software NET DESIGN Page 12 DigiPower power amplifier Page 16 DSV54-4 power supply Page 17 API interface Page 18 Voice alarm speaker systems Page 19 3

- SYSTEM OVERVIEW Media Control For configuration, monitoring, logging and recording 4x analog Audio in RS232 Dynamic or electret Microphone monitoring Built-In Speaker 8x 0-10V Input Fader Panels or Can manage up to more than 4.000 nodes in one network 4

Integrated 2 GByte micro SD Flash Card 4x analog Audio out Panel PC API MIC/LINE Gain, Phantom P., Comp./Limiter,... RS 232 Media Control 4x Speakerline monitoring 5

- SPIDER44 The combined Break-in/Break-out module in 19 design, equipped with 4 analog audio inputs and outputs, 2 network ports and 24 VDC power supply. Other connection options: 2 serial ports (RS-232 and RS-485) for control tasks, 8 analog inputs, 8 digital inputs, 8 digital outputs, optional plug-in card for speaker monitoring (4 channels), integrated 2 GB Micro SD Card Flash memory card as a voice mail. Front-page display for the output of messages, program selection and volume. The digital encoder / push-button can also be used to operate the SPIDER44 directly when configured accordingly. Furthermore, located at the front an infrared receiving diode is in place allowing an access via IR remote control (e.g.: Program and volume). AES/EBU TX- TX+ RX- RX+ T 10V RX TX T 1 6

Technical data: General: up to 64 digital audio channels (default) IEEE802.3 Ethernet - based network with 100Mbit/s duplex 4 analog audio inputs and 4 analog outputs (XLR / M / F) lowest latency times due to high-performance DSPs Power supply: 24 VDC Interfaces / IOs: 8 analog inputs 8 digital control inputs, 8 digital control outputs 1x RS232, 1x RS485 2x Ethernet RJ45 connector Infrared Remote Control Audio Features: 16/24 or 32-bit Digital Audio Sample rate: 48 or 96 khz Adjustable latency: 0.6 / 1.3 / 2.6 ms Dynamic range: 103 db Total harmonic distortion (THD) <0.005 % Frequency response: 20 Hz - 20 khz (± 0.5 db) 44 B A DC 24V POWER IN ZONE 1 ZONE 2 ZONE 3 OUT + - + - + - IN OUT RET. IN OUT RET. IN RET. + + - + - + - + - + - + - + - + - - ZONE 4 44 IN OUT RET. + + - + - - 2 3 4 5 6 7 8 T 10V 44 Made in Austria 7

- SPIDERMIKE2 The call station, remote control and monitoring system - all in one. ITEC Spidermike2 is equipped with the same characteristics as the Spider44, however the functions are distributed in a different way. The communication terminal offers 19 soft keys (that can be labeled with insertion stripes individually), a double spaced message monitor for the display of help and error messages, a XLR connection for microphones (dynamic or electret), a built-in speaker for microphone monitoring, intercom, respectively alerting integrated 2 GByte micro SD Flash Card. Rear panel connectors: 2 x RJ45 network port, Power supply: 24 VDC. Optional Keyboard Extensions à 24 keys. Expandable to 115 keys. Audio In 2 Audio Out 2 Power Supply 24 VDC RS232 Interface Analog Control Inputs Digital Outputs 8

Technical data: General: Ethernet-based network with 100 Mbit /s duplex (CAT5 cable or fiber optic) 2 analog microphones / line inputs Integrated speaker 1 additional analog audio output 2-line text display for status and error messages 19 free configurable soft keys 2 digital outputs 6 analog measurement inputs Integrated 2 GByte micro SD Flash Card Power supply: 24 VDC Audio Features: 16/24 or 32-bit Digital Audio Sample rate: 48 or 96 khz Adjustable latency: 0.6 / 1.3 / 2.6 ms Dynamic range: 103 db Total harmonic distortion (THD) <0.005 % Frequency response: 20 Hz - 20 khz (± 0.5 db) SpiderMike2 Base Station Keyboard Extensions (Up to 4x 24 keys) Automatic microphone monitoring and logging (Audio In 1) Built-In speaker (Audio Out 1) 9

- FIRE FIGHTERS CALL STATION (ACC. TO ÖNORM F 3033) The fire fighters call station has within all security relevant PA applications always the highest priority. With this call station the responsible fire fighters chief is able to activate, start or interrupt on the flash card pre-stored alarm and evacuation messages across zones. When removing the microphone from its holder, text announcements are interrupted and live announcements can be spoken in by pushing a further talk button at the microphone. All functions of the call station are continuously monitored to ensure an operation at all times: For example, the function of the microphone cartridge, the contents of the memory chips and the microprocessors. The call station is networked redundant to the ITEC NET switches, and what the 24 V DC power supply concerns connected to the ITEC NET backup power supply. Different national and international standards are governing the functions and features of call station for fire brigades. The terminal shown here corresponds to the Austrian standard F3033 (for system designs according to TRVB S 158). Technical data: General: Ethernet-based network with 100 Mbit /s duplex (CAT5 cable or fiber optic) Hand held microphone Integrated speaker 1 additional analog audio output 6 announcement buttons Status indication lights 2 digital outputs 6 analog measurement inputs Integrated 2 GByte micro SD Flash Card Power supply: 24 VDC Audio Features: 16/24 or 32-bit Digital Audio Sample rate: 48 or 96 khz Adjustable latency: 0.6 / 1.3 / 2.6 ms Dynamic range: 103 db Total harmonic distortion (THD) <0.005 % Frequency response: 20 Hz - 20 khz (± 0.5 db) 10

- NETWORK SWITCH ITEC NET is based on the Ethernet standard IEEE 802.3, layer 2, 100 Mbit/s duplex in principle. That means for setting up a network you can use all the standard components of the computer world for networking ITEC NET devices without hesitation. However, the switches are system relevant components and need to be certified for the implementation in security sound systems according to EN 54-16. As leading manufacturers of network switches have no devices in their program to date, which are certified according to this particular fire alarm standard, we have developed a switch on our own and precisely tailored it to the ITEC NET requirements. Among others, these are facilities with fiber optic connections for long distance transmissions and single-source 24V DC power supplies (for a connection to certified power supply devices). Technical data: General: Meets IEEE802.3u standard Provides 2x 4x 10/100 Mbps Fast Ethernet ports and 1 x 100 Base-FX port Global LED support (e.g.: power status, 100Lnk/Act, Full duplex per port) IEEE 802.1q tag-based VLAN VLAN ID tag / un-tag options per port QoS priority management per port Automatic MDI / MDI-X crossover Stand alone (opt. managed functionality) DC IN Power: 24 V / max. 1 A Fiber port: Supports multi-mode fiber and SC connectors 802.3u 100 BaseFX compliant Fixed 100 Mbps Full duplex operation 11

- THE SOFTWARE NET DESIGN ITEC NET DESIGN is a Windows-based application for configuring and monitoring the entire ITEC NET network. Included is a TCP/IP interface (ITEC NET API) allowing a direct link to other control systems, such as media control or security management systems. In addition NET DESIGN offers the possibility to update the DSP- and control software from any point of the network. The huge number of monitoring and logging capabilities ensures a safe operation within this large audio and data distribution system. System Overview In this window you will find all ITEC NET components plus the connected configuration PCs. Photos or sketches of the system floor plan can be used as background information with a free arrangement of all components. The jump to function quickly finds all devices with direct access to the configuration pages. System Tree Audio Input Config Each audio input has the following settings: Mic / Line Gain in db steps Compressor / Limiter Various level controls Network channel assignment 12

A particular highlight is the exceptional possibility of real-time configuration: The technician can configure ITEC NET Systems in real-time during operation without the need for a system re-boot afterwards. The software runs on Windows XP / Server 2003 / Windows 7 / Server 2008 System Tree Audio Output Config Each audio output has the following settings: Modes (for example: Normal Operation) 4-channel mixer (mixing up to 4 network channels on one output channel) Output level control selection System Tree Audio Output Priority Table Independent of the program channels the priority channels are defined here: 16 different priority levels are adjustable 13

- THE SOFTWARE NET DESIGN System Tree Output EQs, Delay For each audio output the following DSP functions are available: 4x fully parametric EQ and / or 4x high-pass filter 4x low-pass filter 4x high shelf 4x low shelf 1x delay up to 650ms System List Feeding Channels Displays the current state of all audio channels in the network. Offers the possibility of recording simultaneously up to 8 network channels on a PC. 14

System Tree Keypad Config Table Different functions can be assigned to each soft key, e.g.: Zone selection Talk key All Zones Chime Delete Alarm texts + / -, up / down, etc. System Tree Zone Select Table With an entry in this table individual outputs or groups of outputs are explicitly addressed via priority announcement channels. This allows the direct access of a call station to specific output zones (The prioritization of terminals among each other had been defined in the output priority table in advance). 15

- DIGIPOWER POWER AMPLIFIER Full power even at 24 V DC single supply! An absolute must for system designs conforming to international standards. Power supply equipment according to EN 54-4 provides after a breakdown replacement power directly from the connected accumulator (24 V DC). Therefore power amplifiers must be capable to provide even at 24 V DC the full output power. The new ITEC DigiPower series not only meets this requirement, but offers also many other important features such as an energy-optimized stand-by mode. 2 models: 2x250 W/100 V and 4x150 W/100 V Control LEDs for all signal and operation states Fault signals for battery and mains Fault signal for the power amplifier 2/4 channel in a 2 HU 19 rack Low installation depth (only 260 mm) All connections plug-in/screw terminals Balanced inputs with transformer option Automatic stand-by mode Protection for open-circuit, shorts, over temperature, DC 230 V AC and DC 24 V power supply Start-up delay Maintenance-free cooling system without fans Digital signal processing Only 10 W power consumption in stand-by mode Channel A Channel B DIGI POWER 4x150T Fault Clip Fault Clip 24V DC Operating mode Signal Operating mode Signal 230V AC Channel C Channel D Fault Clip Fault Clip Operating mode Signal Operating mode Signal 16

- BACKUP POWER SUPPLY (CERTIFIED ACC. TO EN 54-4) Backup power supply for system designs according to EN 833-4 and TRVB S 158 The digital power supply ITEC DSV54-4 is certified according to EN 54-4:1997 + A2: 2006. It is used to supply the components of the individual modules and for charging / monitoring of the emergency batteries. The power supply is intended for a connection to a 230 V/50 Hz (±15 %) power network and has to be connected via a two-pole pre-fuse of maximum 16 A. The integrated power supply provides power up to 300 W at 24 V DC. Thus during mains operation, in addition to the load current that is needed to recharge the batteries within 24 hours on at least 80 % of its rated capacity, sufficient power for the supply of 24 V system components (Spider44, SpiderMike2, Switch4 /1) is available (e.g.: 6 A for charging batteries with 160 Ah total capacity and 6 A for other devices). Supply voltage, connected batteries and the pre-fuses of the lowvoltage outlets are monitored by the ITEC DSV54-4. Errors are reported via LEDs on the front side and via potential-free relay changeover contacts. The internal resistance of the batteries is also measured cyclical. In case the resistance gets greater than 20 mω, it is reported at the front side via LEDs and relay contacts. The device is equipped with a deep discharge protection, which is activated when the battery voltage drops below 1.8 V/cell and which ensures a reliable protection of the batteries. 17

- API (APPLICATION PROGRAMMING INTERFACE) This TCP/IP based software interface for ITEC NET offers all necessary functions to operate and monitor a system. Using the free available software ITEC tablet designer an application has been implemented. This program allows you easily to manage complex PA systems via an amateur safe and self-explanatory graphical user interface. The user interface can be arranged freely and is highly flexible due to its modular design. Another request to the interface, that had been implemented, was the connection of ITEC NET to higher-level security management systems to combine all security relevant disciplines in a large building (fire alarm systems, access systems, video surveillance, etc.). 18

- VOICE ALARM SPEAKER SYSTEMS Decades of experience in the installation of professional sound systems have taught us that the impact of room acoustics on the speech intelligibility of sound events reproduced by speaker systems is more than important. All new standards in voice alarm sound reinforcement also require the compliance with respect to intelligibility values for announcements and CIS values greater than 0,7. In practice however it means, that for sound installations of halls and stands, the use of ceiling speakers, sound projectors and horn loudspeakers (even if certified) doesn t provide the desired results. Therefore we offer you for reverberant spaces strongly focusing sound columnes and for high-performance full-range applications our highpower fullrange speakers both as certified PA speakers. The most important ITEC PA speakers, which will be used within 100V full range applications as well as in voice alarm sound reinforcement systems, are currently under certification. By the end of 2011 are the following models, certified according to EN 54-24, will become available: The ITEC NeodymLine Series The ITEC FocusLine Series ITEC and Monitor12 ITEC PowerTop12 / 2 19

ITEC- Tontechnik und Industrieelektronik GesmbH, A-8200 Lassnitzthal 300 / Austria / Europe Tel.: +43 (0)3133 / 3780-0, offi ce@itec-audio.com