inplan Thermal Oil Boilers have been proven for many years by successful installation in more than 30 countries.

Similar documents
INTEC Engineering GmbH Heating Solutions for the Marine Industry

Condensing Boiler Efficiency

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Cooking at the Speed of light!

1 DESCRIPTION OF THE APPLIANCE

High-efficient gas boiler CompactGas

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

FLASH TANK ECONOMIZER PRODUCT GUIDE

REGULATORS 175/153 Series

Efficiency on a large scale CFB Steam Boilers

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

Natural geothermal energy.

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Laddomat Charging unit

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.

HEAVY DUTY STORAGE GAS

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

COMMERCIAL REPORT / STOCK CONDITION SURVEY. Sydenham Hill Estate Sydenham Hill London SE 23

Electric Flow Boiler

Commercial Gas Furnace Upflow

BorsodChem MCHZ, Czech Republic. 6,000 Nm 3 /h HTCR Topsøe Hydrogen Plant A Case Story: 18 Months from Engineering to Operation

Indirect fired heaters

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

High efficiency, cast-iron gas boiler

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

ECOCIAT. Domestic hot water heat recovery unit

Commercial Gas Water Heaters

Boiler & Pressure Vessel Inspection discrepancies and failures

Backflush filter R8-30W

Solar Hot Water Heaters

FLSmidth ball mill for cement grinding

Boiler Plan II Table of Contents

Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineering solutions.

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

COMMISSIONING OF HVAC SYSTEMS

REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED)

Rotary screw compressors kw 5,5 7, , bar MODULO

Spare Parts List M96A.24SM/B M96A.28SM/B

Oil and Coolant Circulating Heating System. Model - OCSM

RPV - RP - RA air handling units

SIOUX HYBRID WATER HEATER

Stove-boiler for solid fuels KW Directions for use and assembling

Description of functions

Originators of the Flexible Water Tube design

Steam System Best Practices Condensate System Piping

UDSA - UDSBD unit heater

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

ECOplus Solar Cylinder

OTF Oil Fired Pool Heater

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Oil, Gas and Dual Fuel Burners

CHAPTER 9: WATER HEATING

Heating with wood chips and pellets

Conlift1, Conlift2, Conlift2 ph+

Technical Specification. Generating Set with Waukesha engine burning natural gas

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

Practical Examples of Heat Regenerative System at Steelmaking Works

Operating instructions

IGEMA BOILER LEVEL & TDS CONTROLS

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Heat-Pipe Heat Exchanger

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Midland Combustion Electric Line Heaters with Integral Panels

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Laddomat 21 Charging Unit

Tank Heating Solutions. For Oil Spill Response Vessels

300 Series PA Pump and Cooler Assemblies

SunMaxx Solar Filling Station Operating Instructions

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

Making heating systems efficient and cost-effective: boilers, heating controls & more

ELECTRIC CENTRAL HEATING FLOW BOILER

Electric Coolant Pumps. Always at the Correct Temperature

NFPA31FuelOilPiping 1 Revised

Commercial Semi-Instantaneous Water Heaters

Reliable process heating for industrial applications

Power consumption (kw)

ThermoSorb Desiccant Dryers

Thermostatic valve Type AVTA


In-Line Air Separators

Bosch Commercial and Industrial Heating High efficiency steam boilers (175kg/h to 55,000kg/h)

CRN A-F-G-E-HQQE 3x400D 50 HZ

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

High Output Boiler Systems

Boiler and Burner Cleaning and Servicing Specifications

Commercial Gas Water Heaters

Commercial Gas Water Heaters

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Ligentoplant - The biomass cogeneration. Ligento green power GmbH

Solar Thermal Systems

ROTEX gas hybrid heat pump. A strong team.

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

Transcription:

established 1968 Thermal Oil Plants

Top quality and sophisticated technology provide solutions for individual heating problems. inplan Thermal Oil Boiler alternatively of horizontal or vertical design Capacity: 58-16.000 kw (50.000-13.750.000 kcal/h) inplan Thermal Oil Boilers are automatically operating forced flow heaters with a temperature range up to C, depending on the available heat transfer media. inplan Thermal oil Boilers are fitted as standard supply with all coercially available furnaces for fluid or gaseous type fuels. Depending on the range of output and the operational economy, the furnaces are supplied with 2-stage, sliding 2-stage or modulating control. inplan Thermal Oil Boilers are provided with all the necessary control and monitoring appliances, ready wired and fitted with multi-core control cables (approx. 10 m) including multi-pin plugs. inplan Thermal Oil Boilers are always supplied with a separate control cabinet, which has connecting sockets for the multi-pin plugs. The instrumentation and wiring of the control cabinet is of meticulous execution and in accordance with the VDE directives. Since boiler and control cabinet form a unit ready for plug connections, all that is required at the installation site is the mains connection. inplan Thermal Oil Boilers are equipped with spiral casing circulating pumps including coupling, coupling shields, base plate and electric motor. The circulating pumps are virtually free of maintenance. Cooling of the shaft seals is not required. inplan Thermal Oil Boilers can also be supplied as packaged units, whereby boiler, circulating pump, shut-off valves and dirt traps are preassembled to give a compact, ready-to-use unit. Expansion tank and discharge tank are supplied for separate mounting. Thus assembly times on site are considerably reduced. inplan Thermal Oil Boilers of horizontal design have a front door on hinges which can be swivelled out, providing easy access to the combustion chambers for any cleaning and maintenance work that may be necessary. inplan Thermal Oil Boilers have been proven for many years by successful installation in more than 30 countries. inplan Thermal Oil Boilers are economical and reliable.

inplan Thermal Oil Boiler with natural gas/heavy fuel oil burner, circulating pump, control cabinet Output: 1163 kw (1.000.000 kcal/h) max. outward flow temperature: C

Up-to-date technology guarantees optimum efficiency. Sound quality sophisticated technology are the fundamental principles of inplan. By using tried and tested materials inplan guarantees a long service life. Design Features 1. 2. 3. 4. 5. 6. Swivelling front door with assembly flange for burner attachment. Combustion chamber of generous dimension, built to suit the various types of fuel. Second and third flue gas pass designed for optimum heat transmission. Convection section pipe coil of special high grade steel. Radiation section pipe coil of special high grade steel. Rear panel through which heat transfer medium flows, designed to close off the combustion chamber. 7. 8. 9. 10. 11. 12. Gastight welded boiler shell made of steel. High grade heat insulation with mineral fibre. Exterior insulation jacket made from galvanised sheet steel or aluminium sheet. Heat transfer medium inlet. Heat transfer medium outlet. Flue gas discharge.

Manufacturing precision- Operational safety. inplan-thermal Oil Boiler (difference in temperature between outward flow and return flow 20 C) Main dimensions H = horizontal model V = vertical model Subject to design modifications TYPE H 600 H 800 H 1000 H 1250 H 1500 H 1600 H 1800 H 2000 H 2500 H 0 H 3500 H 0 H 5000 H 6000 H 8000 CAPACITY kcal/h x 1000 600 800 1000 1250 1500 1600 1800 2000 2500 0 3500 0 5000 6000 8000 CAPACITY kw 698 930 1163 1453 1744 1860 2093 2326 2907 3488 4070 4652 5814 6976 9304 A 2545 2895 3095 3570 3745 3790 4055 4165 4535 5042 5425 5795 3695 6990 ØB 1514 1670 1660 1898 2008 2040 2047 2077 2125 2197 2270 2640 2840 0 ØC 260 350 500 550 600 700 750 800 TYPE V 600 V 800 V 1000 V 1250 V 1500 V 1600 V 1800 V 2000 V 2500 V 0 V 3500 A 2760 3120 3320 4031 4031 4102 4317 4490 4920 5532 5900 ØB 1514 1670 1660 2008 2008 2040 2047 2077 2125 2197 2270 ØC 260 500 550 600 Larger outputs and models available on request

Comprehensive product range for highest technical demands. Electrically heated inplan Thermal Oil Boiler, 700 kw, 380 volts, 50 cycles, with 7 heating cartridges 100 kw each, circulating pump, control cabinet, max. outward flow temperature C. Prefabricated control stations for drying ranges with electropneumatic control valves, circulating pumps, shut-off valves, dirt traps. inplan plans designs assembles Thermal-Oil Boiler complete with expansion tanks and discharge tanks. Steel chimneys in various designs and materials. Indirectly heated steam generators and hot water heaters. Heat exchangers for heat recovery plants. Pipe systems with fittings and control apparatus. Fuel supply systems. dipl. ing. juergen peters gmbh & co. kg gewerbepark west 4, 76863 herxheim/germany, tel. +49 (0) 7276 92948-0, fax +49 (0) 7276 92948-20 e-mail: info@inplan-gmbh.com, internet: www.inplan-gmbh.com