EVALUATION SUBJECT: STUDOR AIR ADMITTANCE VALVES DIVISION: PLUMBING SECTION: AIR ADMITTANCE VALVE.

Similar documents
This page does not print. Placeholder for Cover art IPS CORPORATION

DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215

DIVISION: PLUMBING SECTION: INSTRUMENTATION AND CONTROL FOR PLUMBING REPORT HOLDER: XIAMEN SPRINT SHOWERS TECHNOLOGY CO. LTD.

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

When Should Examination Preparation Begin?

PLUMBING ROUGH IN INSPECTION

PMA ONLINE TRAINING Venting for Plumbing Systems

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

What to Expect From the Examination. How to Study the Plumbing Codes

Jay R. Smith Mfg. Co.

CHAPTER 11 STORM DRAINAGE

Top 10+ Mistakes of DWV plumbing design

ONTARIO PLUMBING INSPECTORS ASSOCIATION INC. In the public service since Wet Venting. Incorporating Stack Venting and NPC Harmonization

CHAPTER 9 VENTS TRANSPORTATION OF SEWER GAS

State of Connecticut Department of Public Health RADON PROGRAM

2010 Residential Water Heater Replacement Check List

Residential Plumbing BCN 1058

Please also see 10 golden rules for correct Saniflo installation on

Hunter Plastics Ltd Nathan Way London SE28 0AE Tel: Fax:

Plumbing Code in Commercial Kitchens

Report of Impact of Food Waste Disposers on Combination Waste and Vent Systems and Individual Vents Terminating to an Air Admittance Valve

2006 Codes. Please verify the following before calling for inspection

A Cost Comparison for the Supply and Installation of Three High Rise Sewer Stack Systems

CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004

WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Teacher Assessment Blueprint. Plumbing. Test Code: 5175 / Version: 01. Copyright 2010 NOCTI. All Rights Reserved.

SECTION FACILITY STORM DRAINAGE PIPING

JB ENGINEERING AND CODE CONSULTING, P.C Cardinal Drive Munster, IN Phone: Fax:

CHAPTER 11 STORM DRAINAGE

Chapter 7 Plumbing Connections

SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

Amendments to the 2012 International Plumbing Code

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Sewage Compliance Form Instructions

SECTION SOIL AND WASTE SYSTEMS

CHAPTER 5 WATER HEATERS

PLUMBING CODE REGULATION

Arapahoe County Residential Water Heater Installation and Inspection Guide

Job Ready Assessment Blueprint. Plumbing. Test Code: 3061 / Version: 01

EMERGENCY PLUMBING FIXTURES

INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville

SECTION COMMERCIAL PLUMBING FIXTURES

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

Carriers, Fixtures & Piping

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

Why Do I Have Sewer Smells In My Home or Business?

A. This Section includes the following for soil, waste, and vent piping inside the building:

REVISED AGENDA UNIFORM BUILDING CODE COMMISSION PLUMBING /HEAL TH ADVISORY COMMITTEE

Plumbing Identification and Damage Assessment Guide

Pre-Drywall Inspection Report

Grade Level Spill Containment Manholes

Building Condition Assessment Report

- 3 - SANITARY SEWER BACK-UP

Chicago Plumber Licensure Examination Information

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

INTERNATIONAL RESIDENTIAL PLUMBING CODE

Mitigating Basement Backups

Element D Services Plumbing

later damage - Loss ControL

Beacon Hill Sewer District Standard Specifications

Downspout Disconnection Program FAQs

Assessment Blueprint PHCC Educational Foundation Plumbing Year 2

FIX TURE CARRI ERS. 140(a) MPB-2011-USA

Understanding and Designing Plumbing Systems

SMITH MFG. CO. PROTECT YOUR INVESTMENTS. Automatic Backwater Valve SMITH MORRIS GROUP INTERNATIONAL.

How To Make A House Safe

Home Management Checklist: Spring

AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

CHAPTER 7 SANITARY DRAINAGE

The Plumbing Pipeline

Value Engineering Considerations for Cast Iron Soil Pipe and PVC in Commercial Sanitary and Storm Drainage Applications

Georgia State Amendments to the International Plumbing Code

Apprenticeship Curriculum Standard. Plumber. Level 1. Trade Code: 306A

ONE AND TWO FAMILY DWELLINGS Plumbing July, 2007

Chapter PLUMBING CODE

Installation Manual DIAPHRAGM WELL TANK

Electric Water Heater

INTERNATIONAL RESIDENTIAL CODE PLUMBING

SANITARY DRAINAGE CHAPTER 7

SANITARY SEWER BACKUP. Causes & Prevention

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Builder Specifications for Solar Ready Homes

CLARK COUNTY DEPARTMENT OF BUILDING COMMERCIAL PLUMBING AND MECHANICAL INSPECTION CHECKLISTS 2006 CODE

Division A. Compliance, Objectives and Functional Statements

South Carolina Home Inspector Standards of Practice

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

CHAPTER 3 GENERAL REGULATIONS

Element D Services Plumbing

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

Reticulation sewers in basements Technical guidelines

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

Acumen Enterprises, Inc.

Transcription:

ICC-ES Report PMG-1025 Reissued 02/2016 This report is subject to renewal 02/2017 EVALUATION SUBJECT: STUDOR AIR ADMITTANCE VALVES DIVISION: 22 00 00 PLUMBING SECTION: 22 13 19.36 AIR ADMITTANCE VALVE Report Holder: STUDOR, INC., DIVISION OF IPS CORPORATION 500 DISTRIBUTION PARKWAY COLLIERVILLE, TN 38017

ICC-ES PMG Listing PMG-1025 Effective Date: February 2016 This listing is subject to re-examination in one year. www.icc-es-pmg.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council CSI: DIVISION: 22 00 00 PLUMBING Section: 22 13 19.36 Air Admittance Valve Product certification system: The ICC-ES product certification system includes testing samples taken from the market or supplier s stock, or a combination of both, to verify compliance with applicable codes and standards. The system also involves factory inspections, and assessment and surveillance of the supplier s quality system. Product: Studor Air Admittance Valves: Mini-Vent, Maxi-Vent, Redi-Vent, Tec-Vent, Trap-Vent Listee: Studor, Inc., Division of IPS Corporation 500 Distribution Parkway Collierville, Tennessee 38017 www.studor.com Additional listees: Hajoca (Mainline brand) 1942 Airport Road Monroe, NC 28110 Compliance with the following codes: 2015, 2012 and 2009 International Plumbing Code (IPC) 2015, 2012 and 2009 International Residential Code (IRC) 2012 and 2009 National Standard Plumbing Code (NSPC)* *National Standard Plumbing Code is a copyrighted publication of Plumbing-Heating-Cooling-National Association Compliance with the following standards: ASSE 1050 2009, Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems ASSE 1051 2009, Performance Requirements for Individual and Branch Type Air Admittance Valves for Sanitary Drainage Systems- Fixture and Branch Devices NSF Standard 14 2015, Plastic Piping System Components and Related Materials Listings are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the listing or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this listing, or as to any product covered by the listing. Copyright 2016 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 6

PMG-1025 Most Widely Accepted and Trusted Page 2 of 6 Identification: Installation: Models: Conditions of listing: The Studor Mini-Vent, Maxi-Vent, Redi-Vent, Tec-Vent and Trap-Vent must be identified by molded lettering on the lid, indicating the name of the product, the manufacturer s name, manufacturing location (Ellington, Connecticut), and the ICC-ES PMG listing mark. Studor Mini-Vent, Maxi-Vent, Redi-Vent, Tec-Vent and Trap-Vent must be installed in accordance with the manufacturer s installation instructions and the conditions of this listing. The Studor Mini-Vent, Maxi-Vent, Redi-Vent, Tec-Vent and Trap-Vent are air admittance valves conforming to ASSE 1050, ASSE 1051 and NSF 14. The Mini-Vent and Redi-Vent are designed for pipe sizes of 1 1 / 2 inches through 2 inches (38 mm through 51 mm). The Maxi-Vent is designed for pipe sizes of 3 inches through 4 inches (76 mm through 102 mm). The Tec-Vent is designed for 1 1 / 2 inch pipe (38mm). The Trap-Vent is designed for 1 ¼ inches through 1 ½ inches pipe. The Studor air admittance valves are used as a vent termination for individual vents, common vents, circuit vents and branch vents. Mini-Vent, Maxi-Vent, Redi-Vent, Tec-Vent and Trap-Vent are also permitted to be used as the vent termination for a vent stack or stack vent with six branch intervals or less. 1. The Studor Mini-Vent and Redi-Vent are supplied with a connector which enables the valve to be solvent cemented onto 1 1 / 2 -inch- or 2-inch-diameter (38 mm or 51 mm) pipes or screwed into 1 1 / 2 - inch (38 mm) I.P.S. threads. The Tec-Vent has 1 1 / 2 (38mm) I.P.S. threads and does not come with a connector. 2. The Studor Maxi-Vent is supplied with a synthetic rubber connector which enables the valve to be push fitted into a 4-inch-diameter (102 mm) PVC, cast iron or ABS pipe. It may also be installed on a 3-inch-diameter (76 mm) PVC, cast iron or ABS pipe in accordance with the manufacturer s instructions. 3. The use of Studor Mini-Vent, Maxi-Vent, Redi-Vent, Tec-Vent and Trap-Vent is limited to systems subject to siphonage conditions and a maximum pressure condition of 1-inch (25 mm) water column. 4. Each Studor Mini-Vent, Maxi-Vent, Redi-Vent, Tec-Vent and Trap-Vent must be located a minimum of 4 inches (102 mm) above the horizontal branch drain or fixture drain being vented when providing trap seal protection for fixtures or branches. When serving as vent terminals for stack vents or vent stacks, they must be a minimum of 6 inches (152 mm) above the flood level rim of the highest fixture served. 5. Each Studor Mini-Vent, Maxi-Vent, Redi-Vent, Tec-Vent and Trap-Vent must be accessible for replacement if required. 6. The Studor Mini-Vent, Maxi-Vent, Redi-Vent, Tec-Vent and Trap-Vent must be located to allow adequate air to enter the valve. When the products are located in a wall space or attic space, ventilation openings must be provided into the space. When in an attic space, the vents must be located a minimum of 6 inches (152 mm) above any ceiling insulation. 7. The air-admittance valve must be installed in the vertical upright position. The maximum offset from the vertical upright position must not exceed 15 degrees. 8. Each vent must connect to the drain with a vertical connection to maintain an unblocked opening in the piping to the air admittance valves.

PMG-1025 Most Widely Accepted and Trusted Page 3 of 6 9. A minimum of one vent stack or stack vent must extend outdoors to the open air for every building plumbing drainage system unless specifically engineered. 10. The Studor Mini-Vent, Maxi-Vent, Redi-Vent, Tec-Vent and Trap-Vent are permitted to be installed as the vent termination for a vent stack or stack vent with six branch intervals or less or as a branch vent terminal for fixtures on the same floor. 11. The air admittance valves must be installed after the drainage system has been pressure tested. 12. When a horizontal branch connects to a stack more than four branch intervals from the top of the stack, a relief vent must be provided. The relief vent must be located between the connection of the branch to the stack and the first fixture connecting to the branch. The relief vent may also serve as a vent for a single fixture. The relief vent must connect to the vent stack or stack vent and extend to the open air outside the building. 13. The air admittance valves shall not be installed in non-neutralized special waster systems as described in chapter 8 of IPC. 14. The air admittance valves shall not be located in spaces utilized as supply or return air plenums. 15. The air admittance valves without an engineered design (See Figure 11) shall not be utilized to vent sumps or tanks of any type. 16. The Studor Mini-Vent, Maxi-Vent, Redi-Vent and Tec-Vent are produced in Ellington, Connecticut; the Studor Trap-Vent is produced in Darul Eshan, Malaysia under annual surveillance audits by ICC-ES. TABLE 1 AIR ADMITTANCE VALVE MODELS NUMBERS OF STUDOR/IPS NAME ONLY DESCRIPTION Mini Vent w/ PVC adaptor Mini Vent w/ ABS adaptor Maxi Vent USA PVC Redi Vent - w/ PVC adaptor Redi Vent - w/ ABS adaptor Tec Vent Trap Vent TABLE 2 AIR ADMITTANCE VALVE CROSS REFERENCE OF MODEL NUMBERS, STUDOR AND HAJOCA STUDOR/IPS PART NO. DESCRIPTION HAJOCA CORP. (BRIDAGE / MAINLINE BRAND) MODEL NO. 20302 Maxi Vent USA PVC (25 pack) BR10464 / ML10464 20305 X-Pack Mini Vent-PVC (40 pack) BR10465 / ML10465 20336 X-Pack Mini Vent-ABS (40 pack) BR10466 / ML10466 20386 Redi Vent-PVC (120 pack) BR10469 / ML10469 20389 Redi Vent-ABS (120 pack) BR10470 / ML10470 The following diagrams are examples of acceptable designs using the Mini-Vent, Maxi-Vent, Redi-Vent and Tec-Vent

PMG-1025 Most Widely Accepted and Trusted Page 4 of 6 TRAP-VENT TRAP-VENT

PMG-1025 Most Widely Accepted and Trusted Page 5 of 6

PMG-1025 Most Widely Accepted and Trusted Page 6 of 6 Figure 11