Determination of cell density in bacterial cultures using the Hellma fiber optic probe in combination with the Eppendorf BioSpectrometer

Similar documents
Quantifying Bacterial Concentration using a Calibrated Growth Curve

Transformation Protocol

BACTERIAL ENUMERATION

MTT Cell Proliferation Assay

Transformation of the bacterium E. coli. using a gene for Green Fluorescent Protein

UTILIZATION of PLASMA ACTIVATED WATER in Biotechnology, Pharmacology and Medicine. JSC TECHNOSYSTEM-ECO Moscow, Russia April, 2009

Microbiology BIOL 275 DILUTIONS

Lab 10: Bacterial Transformation, part 2, DNA plasmid preps, Determining DNA Concentration and Purity

Transferring a Broth Culture to Fresh Broth

Agilent Cary 60 UV-Vis

Enzymes: Amylase Activity in Starch-degrading Soil Isolates

Nucleic Acid Purity Assessment using A 260 /A 280 Ratios

Theory and Measurement of Bacterial Growth

Agrobacterium tumefaciens-mediated transformation of Colletotrichum graminicola and Colletotrichum sublineolum

Lab Exercise 3: Media, incubation, and aseptic technique

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

Bacterial Transformation with Green Fluorescent Protein. Table of Contents Fall 2012

ENZYME KINETICS ENZYME-SUBSTRATE PRODUCTS

Marine Microbiological Analysis of Ballast Water Samples

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

Use of the ambr 250 in combination with high-throughput design and analysis tools for rapid, scalable USP development

Cloning GFP into Mammalian cells

GRS Plasmid Purification Kit Transfection Grade GK (2 MaxiPreps)

Phosphorus, Reactive (Orthophosphate)

Microbiological Testing of the Sawyer Mini Filter. 16 December Summary

Application Note USD3013. Monoclonal Antibody Production in Suspension CHO Culture Using Single-Use PadReactor Mini Bioreactor

The Determination of an Equilibrium Constant

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

Instructions. Torpedo sirna. Material. Important Guidelines. Specifications. Quality Control

QuickZyme Soluble Collagen Assay

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Green Fluorescent Protein (GFP): Genetic Transformation, Synthesis and Purification of the Recombinant Protein

Transformation Kit BACTERIAL TRANSFORMATION: GREEN FLUORESCENT PROTEIN. Partnership for Biotechnology and Genomics Education

Quaternary Ammonium Compounds DOC

HiPer Ion Exchange Chromatography Teaching Kit

Hellma. Where precision becomes an art. Calibration standards for spectrophotometers by Hellma

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Esterification Method 1 Method to 2800 mg/l (as acetic acid) Reagent Solution

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Related topics: Application Note 27 Data Analysis of Tube Formation Assays.

INTERNATIONAL OLIVE COUNCIL

KINETIC DETERMINATION OF SELENIUM BY VISIBLE SPECTROSCOPY (VERSION 1.8)

STANDARD OPERATING PROCEDURE

Laboratory 5: Properties of Enzymes

National Food Safety Standard Food microbiological examination: Aerobic plate count

Measuring Cell Viability/Cytotoxicity: Cell Counting Kit-F

Fast, easy and effective transfection reagent for mammalian cells

Effects of Antibiotics on Bacterial Growth and Protein Synthesis: Student Laboratory Manual

Transfection reagent for visualizing lipofection with DNA. For ordering information, MSDS, publications and application notes see

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy

Chem 131A: Absorbance of Riboflavin

Aseptic Technique. A GMP/GTP Training Module

Testing Waste Water for Fecal Coliforms and/or E.coli using Colilert and Colilert -18 & Quanti-Tray

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Biological Sciences Initiative

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

LAB 11 PLASMID DNA MINIPREP

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

TransformAid Bacterial Transformation Kit

2 Spectrophotometry and the Analysis of Riboflavin

Shaking Water Baths THERMOLAB

Biology 29 Cell Structure and Function Spring, 2009 Springer LABORATORY 2:CHLOROPLASTS AND PHOTOREDUCTION

Factors Affecting Enzyme Activity

Human Luteinizing Hormone (LH) Custom Kit

DENSITY MEASURING SYSTEMS

VWR SPECTROPHOTOMETERS

ADP/ATP Ratio Assay Kit (Bioluminescent)

DNA quality: electrophoresis, spectrophotometry and fluorometry

Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO

Measuring Protein Concentration through Absorption Spectrophotometry

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Determine Osmolarity Activity Using RFP under PompC

DUST EMISSION MONITORING SYSTEM

Specials. designed. 3rd edition 2015 English. for scientists 1

In order to be useful, a smear must have the following qualities:

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

PARALLEL AUTOCLAVABLE MINI FERMENTERS/ BIOREACTORS

Immunoglobulin E (IgE) concentrations in Human. Immunoglobulin E (IgE) Human ELISA Kit

Contaminant. Publication Order Number. EPA Publication Number. Method. Date. Source of Method. Total Coliforms

Dedicated and calibrated pipettes can reduce variability. The Most Expensive Test is a Retest By Ruth Noe, UK and Ireland Sales Manager

Calculating Nucleic Acid or Protein Concentration Using the GloMax Multi+ Microplate Instrument

DETECTION OF BACTERIAL MOTILITY. To demonstrate bacterial motility by microscopic and macroscopic techniques.

BY UV SPECTROPHOTOMETRY

Induction of Enzyme Activity in Bacteria:The Lac Operon. Preparation for Laboratory: Web Tutorial - Lac Operon - submit questions

Amaxa 4D-Nucleofector Protocol for Mouse Embryonic Stem [ES] Cells For 4D-Nucleofector X Unit Transfection in suspension

One Shot TOP10 Competent Cells

Aerobic Count. Interpretation Guide. 3M Food Safety 3M Petrifilm Aerobic Count Plate

Malondialdehyde (MDA) ELISA

Enzyme Kinetics: Properties of â-galactosidase

ENUMERATION OF MICROORGANISMS. To learn the different techniques used to count the number of microorganisms in a sample.

Your Personal Pipetting Robot

THE ACTIVITY OF LACTASE

First Strand cdna Synthesis

Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law.

Alignment Laser System.

Transcription:

PPLICTION NOTE No. 272 I October 2013 Determination of cell density in bacterial cultures using the Hellma fiber optic probe in combination with the Eppendorf iospectrometer Sarah Kühnapfel 1, Jochen Hallmann 3, Ines Hartmann 1, Tanja Musiol 1, Wolf Wente 2, Martin rmbrecht 1 1 Eppendorf G, Hamburg, Germany ² Eppendorf Instrumente GmbH, Hamburg, Germany ³ Hellma GmbH & Co. KG, Müllheim, Germany bstract Photometric measurement of turbidity for the purpose of determining cell density in a bacterial suspension is a basic method in every molecular biology laboratory. In addition to consumption of single use cuvettes and pipette tips, reduction of the culture volume is an effect of frequent sample removal and subsequent disposal for the purpose of measurement. The present work will show that the alternative use of a fiber optic probe, which operates without consumables and without reduction of the bacterial suspension, in combination with the Eppendorf iospectrometer, yields comparable results and thus presents a good alternative to a common measurement method. Introduction Liquid culture of bacteria serves as a basic method for many experiments, as high cell densities may be achieved by this culture format. Expression of recombinant proteins and amplification of plasmid DN in bacteria are only two examples. For the purpose of liquid culture, the broth is inoculated either directly with a single colony from an agar plate, or with a defined volume from a preculture, followed by incubation predominanthy at 37 C in an incubator shaker for a specific period of time. Depending on the experiment, it is frequently required to monitor cell growth in regular intervals, allowing definition of the optimum moment for cell harvest. Measurement of optical density of a bacterial suspension is based on the light scatter which is captured by the photometer or spectrometer. Such loss of light is measured as optical density or extinction in a spectral photometer at 600 nm. To this end, sample volumes of 12 ml are removed at different time points for measurement in plastic cuvettes. The consumption of items such as single use cuvettes and pipette tips is considerable, and removal of the sample is time consuming. In order to reduce both, the suitability of fiber optic probes for determination of optical density was evaluated as an alternative to the common method of cuvette measurements. The areas of application for fiber optic probes range from process control in chemical plants, to monitoring of bioreactors, to simple control of syntheses on the laboratory scale. Fiber optic probes (figure 1) enable measurement directly inside the solution to be measured, thus also simplifying spectroscopic analyses of samples. dditional advantages of this method include time savings and increased yield. Connection of the light conductors of a probe is possible either directly via SMconnection on the photometer, or via an adapter in the cuvette shaft. For the Eppendorf iospectrometer, the latter configuration constitutes the easiest solution. The light is decoupled by the adapter and guided to the probe by the light conductor. t the tip of the probe the light traverses the measurement gap of defined width, is reflected by a mirror, recoupled to a second light conductor and guided back to the photometer (figure 2). Exchangeable measurement gaps allow quick and flexible selection of 1, 2, 5, 10 and 20 mm path lengths.

PPLICTION NOTE I No. 272 I Page 2 Figure 1: Fiber optic probe by Hellma In order to ensure optimum growth and aeration, culture in flasks is mainly carried out in orbital incubator shakers. In addition to exact temperature control for optimum growth conditions, the use of a programmable refrigerated incubation shaker such as the Eppendorf New runswick Innova 42R ensures timed programming of different temperatures and speeds. Hence, bacterial cultures of a known growth kinetic may be incubated under shaking conditions at 37 C for a defined period of time, followed by growth cessation by stationary cooling at 4 C.* Thus, overgrowth of the cultures past the exponential phase is prevented. Under good cooling conditions liquid cultures survive for approximately one week. The culture my therefore be kept overnight or even over the weekend without compromising quality. Figure 2: Measurement principle of the fiber optic probe Materials und Methods Materials > Eppendorf iospectrometer kinetic > Programmable refrigerated Incubator shaker Eppendorf New runswick Innova 42R > Hellma nalytics 66.1668U.V, mini probe fiber optic probe, path length: 10 mm > PMM Vis Cuvettes, path length: 10 mm > acterial culture: Escherichia coli DH5 > C. ROTH Lmedium (Luria/Miller) for molecular biology Methods In order to obtain a bacterial culture suitable for a series of measurements, a preculture of Escherichia coli DH5 was first generated. The preculture was incubated overnight for approximately 18 h at 37 C and 180 rpm with shaking in the incubator shaker Eppendorf New runswick Innova 42R. The following day, two times 2 ml preculture were removed and transferred to two 1 L flasks containing 200 ml L medium. These two cultures formed the basis for the subsequent series of measurements. third flask with 200 ml L medium only was incubated in the same manner and served as the blank. Incubation of cultures during the measurement series was carried out in the incubator shaker at 37 C and 180 rpm. The respective display selections are shown in figure 3. Measurements were performed once per hour for the first three hours. With increasing turbidity of the cultures, subsequent measurements were carried out in half hour intervals, until a total of 4.5 h, at which time the incubator shaker was programmed to lower the temperature to 4 C. The cultures were then stored in a stationary position overnight. One additional measurement of optical density was performed the following day. * The Innova 42R provides temperature control from 20 ºC below ambient (with a minimum setpoint of 4 ºC) to 80 C. Naturally, both these ranges depend on relative humidity and other ambient factors, as well as the options installed in the unit.

PPLICTION NOTE I No. 272 I Page 3 C Figure 3: Settings on the incubator shaker Innova 42R. ) Main display shows current number of revolutions per minute and temperature. ) Programming function with selection of times, temperature and number of revolutions per minute. Figure 4: Use of the Hellma fiber optic probe with the Eppendorf iospectrometer ) Cuvette adapter of the fiber optic probe for insertion into the cuvette shaft. ) Probe for insertion into the bacterial culture. C) Cuvette adapter and probe are connected by a cable to allow greater freedom of movement The measurements were performed in an Eppendorf iospectrometer kinetic using the preprogrammed method OD600. Growth of the bacterial culture could be deduced from the measured optical density. Figure 5 depicts the path for selection of the method outlined above, as well as the relevant parameters. The measurements were performed as follows: medium was measured to obtain a blank value, followed by determination of optical density of the bacterial cultures. The probe was inserted in as much of an angle as possible to ensure sufficient coverage with medium (figure 4). In order to avoid interfering air bubbles, motion of the culture during measurement should be minimized. For comparison, 1 ml of the bacterial culture was removed and measured PMM macro Cuvettes. 5 replicates were measured, respectively. In order to ensure sterile conditions, the probe was cleaned with 70 % ethanol prior to each new series of measurements. etween time points the probe was kept in VEwater (figure 4C) to avoid precipitation of contaminants on the probe.

PPLICTION NOTE I No. 272 I Page 4 C D Figure 5: Parameter selection on the iospectrometer for use of the 10 mm light path in the method OD 600 ) Selection of method OD600. ) Verification of parameters such as path length and wavelength. C) Display for blank measurement. D) OD600 measurement example of a bacterial culture using the Hellma fiber optic probe on the iospectrometer

PPLICTION NOTE I No. 272 I Page 5 Results and Discussion Comparison of optical density values obtained with a plastic cuvette with those obtained using a fiber optic probe shows only minimal differences between their measurement results. Slight deviations are to be expected for multiple measurements, as OD measurements are simply measurements of turbidity, and motion within the culture needs to be taken into consideration. Table 1 shows the example of measurement after 3.5 h. The standard deviation is small for both measurement systems. It is further evident that the deviation of the average of the results obtained with the probe, compared with those of the PMM macro Cuvettes, is small: a mere 1.2 % at the 3.5 h time point. Table 1: Measurement (OD600) results of the 5fold determinations using the Hellma fiber optic probe and PMM macro Cuvettes, respectively. Time 3.5 h Measurement PMM cuvette 10mm 1 1.186 1.119 2 1.173 1.159 3 1.144 1.150 4 1.149 1.109 5 1.142 1.185 verage 1.159 1.144 Standard deviation 0.020 0.031 Hellma probe 10mm [%] CV 1.693 2.690 Deviation to PMM cuvette 0.014 10 mm Deviation to PMM cuvette 10 mm [%] 1.243 Figure 6 shows the growth curve of one of the cultures measured. The two curves representing optical densities obtained with the fiber optic probe, in comparison with the 10 mm plastic cuvette, are nearly identical up to an OD of approximately 1.2. Only above an OD of 1.4 slight deviations are noted; however, these are small and thus negligible. Due to the congruence of the growth curves it may be inferred that probe and cuvette are equally suited for measurement of bacterial growth. Following termination of bacterial growth after 4.5 h by keeping the culture in the incubator shaker at 4 C overnight, the optical density was slightly lower than that measured on the previous day. This is indicative of complete growth cessation, thus demonstrating the suitability of the incubator shaker s cooling and general programming functions for termination of further culture growth following the incubation phase. This also applies during times when it is not possible to transfer the cultures from the incubator to the refrigerator. Figure 6: Growth curve of one of the bacterial cultures measured with the fiber optic probe compared with the 10 mm PMM macro Cuvettes. The 5 h time point is equivalent to the result obtained on the following day after testing the cooling function of the incubator shaker (value = 24 h). If bacterial cultures are very overgrown, it is possible that optical density measurements can no longer be performed. Since OD measurements at very high bacterial concentrations do not follow linear kinetics it is not recommended to simply dilute the culture. Measurement of the diluted suspension will not yield the true OD of the undiluted culture. More accurate results may be obtained with a fiber optic probe of shorter path length (e.g. 2 mm). With this approach, a possible dilution error can be avoided. If a probe with shorter path length is to be used, the respective value is changed in the method parameters for the purpose of OD calculation (figure 7). In the results display, this value is automatically calculated to a path length of 10 mm. The original data are also displayed.

PPLICTION NOTE I No. 272 I Page 6 Figure 7: Parameters to be selected and measurement results obtained when using a fiber optic probe with a path length of 2 mm. ) Selectable parameters: If using a path length of 2 mm, this must be changed in the respective field. ) Measurement result display: The value displayed in smaller font represents the original measurement with a path length of 2 mm; the value displayed in larger font represents the value calculated for a path length of 10 mm. Conclusion The series of experiments performed here was able to show that the alternative use of a fiber optic probe yields equally good results which are comparable to those obtained with a cuvette. Since sample removal from the culture flask is not required for this method, but rather the measurement occurs directly inside the vessel, time is saved, as well as consumables such as pipette tips and single use cuvettes. further advantage is the option to measure higher cell densities due to the exchangeable path lengths included with the probe. Furthermore, the advantage of the programmability of the incubator shaker Eppendorf New runswick Innova 42R could be demonstrated. Since no further bacterial growth occurred in the cooled incubator shaker overnight, this instrument is ideally suited for growth, followed by cooling, of bacterial cultures. If growth parameters of a bacterial culture are known, this incubator shaker may easily be used overnight or over the weekend by programming the desired times, temperatures and revolutions per minute.

PPLICTION NOTE I No. 272 I Page 7 Ordering information Description Order no. International Order no. North merica Eppendorf iospectrometer kinetic 230 V/5060 Hz, European power plug, additional power plug connections available 120 V/50 60 Hz, mains plug for North merica Eppendorf iospectrometer basic 230 V/5060 Hz, European power plug, additional power plug connections available 120 V/50 60 Hz, mains plug for North merica Eppendorf New runswick Innova 42R Incubated/Refrigerated, 3/4 orbit, 230 V, 50 Hz 120 V, 60 Hz Eppendorf New runswick Innova 42R Incubated/Refrigerated, 1 orbit, 230V, 50 Hz 120 V, 60 Hz Hellma fiber optic probe 6136 000.002 6136 000.010 6135 000.009 6135 000.017 M13350006 M13350004 M13350016 M13350014 661.668UV 6136000010 6135000017 M13350004 M13350014 Your local distributor: www.eppendorf.com/contact Eppendorf G 22331 Hamburg Germany eppendorf@eppendorf.com www.eppendorf.com www.eppendorf.com C. Roth is a trademark of Carl Roth GmbH & Co., Germany. Hellma is a registered trademark of Hellma GmbH & Co.KG. Innova is a registered trademark of New runswick, Scientific, Co., Inc., US. New runswick is trademark of New runswick, Scientific, Co., Inc., US. Eppendorf, the Eppendorf Logo and Eppendorf iospectrometer are registered trademarks of Eppendorf G, Germany. ll Rights reserved, incl. graphics and images. Copyright 2013 by Eppendorf G.