3M Passive Optical Splitter Shelves and Modules

Similar documents
Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable

Healthcare. Passive Optical LAN Solutions

3M Quick Connect System (QCS) 2810 Models 2810A and 2810B

Expanding a 40-Type Cabinet

3M Quick Connect System (QCS) 2814

3M Serial Attached SCSI (SAS) Connector Boardmount Compliant Pin and Surface Mount, Vertical Receptacle

Physical. Electrical. Environmental. Insulation: Contact: Plating: Temperature Rating: -55 C to +85 C

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

Cable Assembly Solutions at the Speed of Light

Gigabit Passive Optical Networks

SATELLITE TV on fiber

3M Dynatel Triple Play Customer Service Test Set INS970

3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series

3M Integrated Splitter Block BRCP-SP

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

3M One Pass Fiber Pathway

3M Pin Strip Header.100,.295 Mating Length, Straight & Right Angle, Solder Tails 929 Series

3M Pin Strip Header Single and Dual Row.100,.235 /.318 Mating Length, Straight & Right Angle, Solder Tails 929 Series

Faster Method for Connecting Customers in the Colocation Data Center

OSMIUM HIGH DENSITY FIBER OPTIC CHASSIS

3M Wrist Strap and Footwear Tester 740. User s Guide

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

Reliable, Consistent, Quality

3M Pin Strip Header 2 mm 2 mm Solder Tail Straight & Right Angle, Surface Mount Straight 1512 Series

3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series

Discontinued. Volition. Fiber Optic Cable. 3Innovation

PHOENIX OPTIX WIRING AND INTERCONNECT SOLUTIONS

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

ATTACHMENT F 050R CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

3M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer

2 To 1 Serial (RS-232) AUTO SWITCH. AS-251S User Manual

T1 Backhaul Connectivity Solution All Products :: Application Note

3 740 Wrist strap + shoe tester

InstaPATCH ZERO Solution Guide

The Infrastructure of Tomorrow, Available Today. Luca Rozzoni RCDD Business Line Manager TE Connectivity

Obsolete Fiber Technology? Not in my Data Center!

FTTH ARCHITECTURE WHITE PAPER SERIES

FACT OPTICAL DISTRIBUTION FRAME SYSTEM

16-Port and 24-Port 10/100 Switches

T-Extender E-Extender

Pretium EDGE HD Solutions

Cables and Accessories Selection Guide

16/32 Channel 1U Rack Mount CCTV Power Supply

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

Infrastructure for the next three generations

F2400 FOM II Series Fiber Optic Modem Technical Manual

FCS-FCT-FCP Housings and Connector Panels. InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

What testing is required for PREMISES Fiber Optic Cabling and the standards used

2-Way Wireless Indoor Siren Installation Guide

Data Center Topology Guide

Network Monitoring - Fibre TAP Modules

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

HARTING Ethernet Cabling 8-poles Overview

Advantium 2 Plus Alarm

ADC Structured Cabling Solutions

Belden. Optical Fiber Catalog. One Enterprise. One Infrastructure. One Partner. Belden IBDN FiberExpress Systems

BroadBand PowerShield. User Manual

Pretium Connector Housings

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

Plug & Play Universal Systems

How To Use A Network Instrument Ntap

Advantages of Fiber Optic Splitters in Key Applications Increase the Efficient Use of Optical Infrastructure with These Passive Components

ASKING FOR ASSISTANCE

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

CHARTER TOWNSHIP OF SHELBY REQUEST FOR PROPOSAL. Fiber Optic and Data Cabling Project Shelby Township Police Building

Fundamentals of Fiber Cable Management WHITE PAPER

Cisco SFP Optics for Gigabit Ethernet Applications

How To Make A Data Center More Efficient

AMP NETCONNECT Data Center Cabling Solutions

Single Port T1/E1 Tap

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

Secure/Keyed LC System Solutions Overview

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER

2X1 DVI Switch (DS-21R) 4X1 DVI Switch (DS-41R) USER MANUAL. DTronics Inc.

Gigabit Switching Ethernet Media Converters - Product User Guide

Living Infrastructure

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

TrueAlarm Fire Alarm Systems

Unpacking, Installation, and Customization

FTTX Solutions FDH 3000 Cross-Connect

LANC Fibre Patch Panel Solution

CISCO 10GBASE X2 MODULES

Optimux-34, Optimux-25

Optical Power Meter. Specification & User Manual

ETD Fiber Optic Products

InstaPATCH Cu Cabling Solutions for Data Centers

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand

Quick Reference Guide Euro Style Terminal Blocks

3M Wireless Infrastructure Solutions. Moving. Mobility. Forward

Nest Learning Thermostat Installation Guide. Installation step-by-step

TECHNICAL NOTE 7-1. ARCNET Cable Length vs. Number of Nodes for the HYC9088 in Coaxial Bus Topology By: Daniel Kilcourse May 1991.

Transcription:

Communication Markets Division 3M Passive Optical Splitter Shelves and Modules 3M offers a robust portfolio of passive optical fiber splitter products made to enable easy configuration, design, ordering, and installation of passive optical networks. 3M Passive Optical Splitters are compliant to GR- 1209/GR-1221 and factory tested. Splitters are optimally configured and labeled with port counts specifically suited for PON networks and are self-contained and pre-connectorized to enable easy interconnect or cross-connect configurations. 3M Passive Optical Splitters enable various physical topology solutions to optimize the optical signal distribution for PON networks in a campus environment or throughout a building according to the installation needs including rack-mount, wall-mount or ceiling/ floor enclosure. 3M Rack-mount 1RU Splitter Shelf and optional 3M Patch Cord Management Tray Product Overview Application Product range Splitter shelves Splitter modules Standards Passive optical networking applications that require fiber optic splitter components to branch and distribute the optical signal to multiple endpoints. Products are available to accommodate evenly distributed optical splitter configurations from 1x2 to 2x32. 1RU 19" rack-mount pre-configured and SC/APC pre-connectorized splitter shelves are available in five models (1x32, 2x32, two 1x16, two 2x16, four 1x8s). Splitter modules, pre-connectorized with SC/APC, can be installed in various 3M Fiber Distribution Unit rack or wall-mount enclosures or flat rack-mount panels. They are available with the following port configurations: 3-slot wide (2x32, 1x32, two 2x16, two 1x16, four 1x8s, four 2x8s) 2-slot wide (2x16, 1x16) 1-slot wide (2x8, 1x8, two 1x4s) Telcordia GR1209 Generic Requirements for Passive Optical Components and GR1229 Generic Reliability Assurance Requirements for Passive Optical Components, SC/APC connectors are GR-326 compliant

Fiber optic splitters are used typically to enable passive optical networks signal distribution between the main aggregation optical line terminal/ switch and the singlemode fiber-fed multiple optical network terminals/ endpoints. 3M Passive Optical Splitter products are clearly labeled with connectorized SC/APC couplers into and out of the modules which makes them easy to configure, install, and test for passive optical networks. 3M Passive Optical Splitter Shelves and Modules 1x8 (1-slot) 1x16 (2-slot) 1x32 (3-slot) 3M Splitter Modules Features Factory tested High performance specifications Self-contained units Pre-connectorized SC/ APC Produced to industry specifications Both rackmount shelf and modular Benefits Consistent quality, faster installs Provides infrastructure longevity, flexibility in optical design Protects fibers, provides increased reliability Ready for quick installation on arrival Provides system compatibility and interoperability Allows flexible, optimized configurations for the project 3M Flat Mount Panel Splitter performance values (provided without connectors): Operating wavelength range 1260-1650 nm Parameters 1X2 1X4 1X8 1X16 1X32 2X4 2X8 2X16 2X32 Insertion loss (max db) 3.8 7.1 10.5 13.5 16.8 7.5 10.8 14.1 17.4 Uniformity (db) 0.5 0.6 0.8 1.2 2.5 1.2 1.5 2.0 2.5 PDL (db) 0.2 0.2 0.25 0.3 0.4 0.3 0.4 0.4 0.4 Return loss (db) 55 55 55 55 55 55 55 55 55 Directivity (db) 55 55 55 55 55 55 55 55 55 Maximum insertion loss Uniformity Polarization Dependent Loss (PDL) Return loss Directivity Ratio of optical power at the input port of the coupler to optical power from any single output port. Maximum value for the device over entire operating wavelength and temperature range. Measure of how evenly power is distributed between the output ports of the splitter. It is the maximum variation of the insertion loss between different legs of the splitter. Performance of a splitter can vary slightly depending on the direction of polarization of light in the fiber. PDL is a measure of variation of the coupler s insertion loss with varying polarization of the signal. Return loss is the ratio of optical power into an input port to the power returning to the same port. Ratio of the optical power into an input port to the optical power returning to any other input port.

3M Connectorized Splitter Shelves and Modules (includes two SC/APC connected pairs) Optical Insertion Loss and Reflectance Specifications: Parameters 1X2 1X4 1X8 1X16 1X32 2X4 2X8 2X16 2X32 Insertion Loss (max db) 4.6 7.9 11.3 14.3 17.6 8.3 11.6 14.9 18.2 Return Loss (db) 55 55 55 55 55 55 55 55 55 3M factory connectorized SC/APC insertion loss per mated pair: Typical.15 db, Max.4 db, return loss better than 60 db 3M Rack-mount 1RU Splitter Shelves 19-inch 1RU self-contained splitter shelf (1.7" H x 19" W x 6.9" D) All pre-connectorized with SC/APC Dual input splitters are provided to enable redundant configurations Use with second fiber patch panel for cross connect or stand alone for interconnect solution Optional, removable front fiber management tray for the unit 3M Rack Mount 1RU Splitter Shelf and optional 3M Patch Cord Management Tray 3M Patch Cord Management Rings, 1 RU 8421BK-132 Splitter shelf 1 rack unit, one 1X32 SC/APC in/out 80-6114-8025-4 8421BK-232 Splitter shelf 1 rack unit, one 2X32 SC/APC in/out 80-6114-8026-2 8421BK-2X116 Splitter shelf 1 rack unit, two 1X16 SC/APC in/out 80-6114-8027-0 8421BK-2X216 Splitter shelf 1 rack unit, two 2X16 SC/APC in/out 80-6114-8028-8 8421BK-4X108 Splitter shelf 1 rack unit, four 1X8 SC/APC in/out 80-6114-8029-6 8421BK-MGR Patch cord management tray for 19" splitter shelf, black 80-6114-8430-6 8421BK-RNG Patch cord management rings, 1 RU for 19" shelves 80-6114-8431-4

3M Fiber Optic Splitter Modules 1-, 2-, or 3-slot-wide splitter modules Fits into various 3M fiber enclosures (check for enclosure number of slots available) Compatible with 3M Rack-mount Fiber Distribution Unit 8425, 3M Wall-mount Fiber Distribution Units 8430 series, 3M Wallmount Boxes 8437 series and 3M Rack-mount Panels 8422 series. Allows flexible, mix-n-match configurations with other 3M modular products (multi-fiber push on (MPO) trunk fan-out modules) 1-slot 2-slot 3-slot 3M Fiber Optic Splitter Modules 1-slot 1-slot module dimensions: 5.1" H x 1.15" W x 6.12" D 2-slot module dimensions: 5.1" H x 2.47" W x 6.12" D 3-slot module dimensions: 5.1" H x 3.72" W x 6.12" D 3M Rack-Mount FDU 8425 (12-slot capacity) with four 3-slot splitter modules Product Number Description Color 3M ID 8443BK-132 Splitter module, 3-slot wide, one 1X32 SC/APC in/out Black 80-6114-8034-6 8443BK-232 Splitter module, 3-slot wide, one 2X32 SC/APC in/out Black 80-6114-8035-3 8443BK-2x116 Splitter module, 3-slot wide, two 1X16 SC/APC in/out Black 80-6114-8036-1 8443BK-2X216 Splitter module, 3-slot wide, two 2x16 SC/APC in/out Black 80-6114-8037-9 8443BK-4X108 Splitter module, 3-slot wide, four 1X8 SC/APC in/out Black 80-6114-8038-7 8443BK-4X208 Splitter module, 3-slot wide, four 2X8 SC/APC in/out Black 80-6114-8039-5 8442BK-116 Splitter module, 2-slot wide, one 1x16 SC/APC in/out Black 80-6114-8040-3 8442BK-216 Splitter module, 2-slot wide, one 2x16 SC/APC in/out Black 80-6114-8041-1 8441BK-108 Splitter module, 1-slot wide, one 1X8 SC/APC in/out Black 80-6114-8043-7 8441BK-204 Splitter module, 1-slot wide, one 2X4 SC/APC in/out Black 80-6114-8091-6 8441BK-208 Splitter module, 1-slot wide, one 2X8 SC/APC in/out Black 80-6114-8044-5 3M Rack-mount Fiber Distribution System 8425 series The 3M Rack-mount Fiber Distribution Unit 8425 is a 4RU, 19" patch panel design accepting either the 3M Splitter Modules or 3M MPO to SC/APC Fan-out Modules in one-, two-, or three slot wide configurations. The 8425 may also be used with many modular adapter plates available with industry accepted connector adapters. 3M Rack-mount Fiber Distribution Unit 8425 8425BK FDU 4RU (holds 12 slots/plates) 80-6113-3545-8 8425BK-BPL FDU 4RU back panel with one 3M Splice Tray 2524-FT, locking doors (holds 12 slots/plates) 80-6113-3546-6

3M Wall-mount Fiber Distribution System 8437 Series The 3M Wall-mount Fiber Distribution System 8437 is a double door, lockable wall box designed specifically for the 3M Splitter Modules and 3M MPO to SC/APC Fan-out Modules in one-, two-, or three-slot wide configurations. 3M Wall-mount Box 8437 3M Wall-mount 8437 Boxes 8437BK-2HDM Wall-mount box for 2 3-slot splitter modules 80-6114-8432-2 8437BK-3HDM Wall-mount box for 3 3-slot splitter modules 80-6114-8433-0 8437BK-4HDM Wall-mount box for 4 3-slot splitter modules 80-6114-8434-8 3M Fiber Distribution Terminal PBPOC Series The 3M Fiber Distribution Terminals PBPOC with integrated splitters are wall-mounted compact boxes for application into distributed splitter architectures as part of a Passive Optical LAN Network. Because of this box's aesthetically pleasing design, it can easily integrate into common office environments without distraction. Fiber Distribution Terminal PBPOC 2x104 Product Number Description Color 3M ID PBPOC-2X104 Wall box, plastic, with two 1x4 splitters, SC/APC outputs White 80-6114-8433-0 PBPOC-108 Wall box, plastic, with one 1x8 splitters, SC/APC outputs White 80-6114-8434-8 3M is a trademark of 3M Company. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of 12 months from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. Communication Markets Division 6801 River Place Blvd. Austin, TX 78726-9000 USA Phone 1-800-426-8688 Fax 1-800-626-0329 Web 3M.com/Telecom Please recycle. Printed in USA 3M 2016. All rights reserved. 80-6116-2013-1