Specifications. S&C CS Line Post Current Sensors and CSV Line Post Current/Voltage Sensors Outdoor Distribution (14.4 kv through 34.

Similar documents
Transmission Silicone Insulators Line Post 69 kv to 161 kv

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

Design Test Report Veri*Lite Suspension Insulators Catalog Numbers: , , ,

DS 600. A contact free flux gate based current measurement sensor 600A rms

The very Best. ANSI Post Insulators 2016

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

Composite Insulators Suspensions Line Posts Brace Posts Station Posts

Veri*Lite Silicone Rubber Line Post Insulators for 15-69kV Applications

SPECIFICATIONS. S&C Switch Operators Type PM SPECIFICATION BULLETIN For Field Retrofit on Manual PMH, PMS, and PME Pad-Mounted Gear

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

PART 1 - INTRODUCTION...

Veri*Lite Deadend & Suspension Insulators for 15-69kV Applications

P O W E R C A P A C I T O R A S S E M B L I E S

Medium voltage insulator

Voltage Loss Formula s

HV glass suspension insulator U70BS and U70BL type Ball and socket type Standard profile

Current Limiting Protector For Systems rated kV and continuous currents through 5000A.

Hi*Lite XL Transmission Insulators

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Lightning Arresters P KVA P KVA. Description & Installation

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

Current Probes. User Manual

Using Current Transformers with the 78M661x

6 Buck Boost Transformers

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

WIRE AND CABLE ENGINEERING GUIDE

Hyperlinks are Inactive

New XUY roller sensors

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

SMA Interface Mating Dimensions (Per MIL-STD-348)

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

3-Component Measuring System

ALARMLINE ANALOGUE Linear Heat Detection System

NAVICOM DYNAMICS RTK BASE STATION INSTALLATION AND COMMISSIONING INSTRUCTIONS

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

CAUTION. 4. Cable Connections DANGER WARNING CAUTION. 3. Bushing Components

K-Type Thermocouple Sensor User s Guide

OLI. Oil level indicator

ENGINEERING COMMITTEE

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Low Frequency Velocity Sensor

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

An Overview of Lapp Insulator High Voltage Bushing Design

Operating Temperature Range: -30 to +85ç (Note 1) Operating Humidity Range: 40 to 80%

KNOW YOUR OPTIONS: 230 KV POWER CABLES

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Velomitor Piezo-velocity Sensor

WIRE AND CABLE ENGINEERING GUIDE

SnoTrace KSR Surface Snow and Ice Melting INSTALLATION PROCEDURES

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Mylar polyester film. Electrical Properties. Product Information. Dielectric Strength. Electrode Size. Film Thickness

Specifications. S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)

Z-TRAUQ INC. Tel.: (450) Fax: (450)

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits, 7620-S, 7680-S and 7690-S Series 5, 8, 15, 25/28 and 35 kv

Table of Contents. TransformerIQ FAQs 1

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

Current Transformers

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

Times Microwave Systems Hermetically Sealed Assemblies

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

V.A PJM Design and Application of Overhead Transmission Lines 69kV and Above

Enhanced Quality with a Touch of Style

World Leader in HV Testing Technology

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

Vario-Series Accessories

Section kv Power Cables

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Low Voltage Switchboards The Best Technical Solution for Your Ship

New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

How To Use A Corona Mdi 110

Instrument Transformers Application Guide

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

18 AWG thru 8 AWG Not greater than 100/30 100/30. 6 AWG thru 1/0 AWG Not greater than 200/60 100/30

Current and Temperature Ratings

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Current Transformers

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Transcription:

S&C CS Line Post Current Sensors and CSV Line Post Current/Voltage Sensors Outdoor Distribution (14.4 kv through 34.5 kv) For Capacitor Control Applications Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. How to Order Select the catalog number of the desired sensor from the table below. SPECIAL TO THIS PRODUCT: INCLUSIONS: S&C CS Line Post Current Sensors provide the current-sensing input for S&C IntelliCap and IntelliCap Plus Automatic Capacitor Controls. CSV Line Post Current/ Voltage Sensors provide both current- and voltage-sensing inputs for these controls. Available in ratings of 14.4 kv, 25 kv, and 34.5 kv, CS and CSV Sensors are vertically mounted with a hot stick; sensor calibration is unnecessary. Current- and voltage-signal calibration is virtually unaffected by conductor material or size, temperature, armor rod, adjacent phases, line angle, or insulator contamination. The two-sided keeper is made of galvanized ductile iron and can accom modate aluminum or copper conductors ¼ to 1¼ in diameter. These molded polymeric sensors are less sus ceptible to damage than porcelain sensors. For CS and CSV Line Post Sensors, the current sensor output is 1 VRMS/60 Amps. The CSV Line Post Voltage Divider Ratio is 10000:1. S&C CS and CSV Line Post Sensors Item CS Line Post Current Sensor Nominal Voltage Rating, kv Catalog Number Page Reference for Dimensional Drawings Net Wt. Lbs., (Kg.) 14.4 904-001124-00 4 44 (19.8) 25 904-001125-00 5 54 (24.3) 35 904-001126-00 6 64 (28.8) 14.4 904-001128-01 4 44 (19.8) CSV Line Post Current/Voltage Sensor1 25 904-001129-01 5 54 (24.3) 34.5 904-001130-02 6 64 (28.8) 1 CSV Sensors can be used with cap controls, in place of the recommended CS Sensors, by using cable Catalog Number 904-001155- 01 to connect the CSV Sensor to the junction box. Sensor power is not available for S&C Capacitor Controls, so control power is required with CSV Sensors. May 4, 2015 S&C Electric Company 2003-2015, all rights reserved Specification Bulletin 1061-31

S&C Electrical Ratings Insulation Class1 15 kv 25 kv 35 kv Impulse (BIL) 110 kv 150 kv 200 kv Withstand (60 Hz, 1 minute) 34 kv 40 kv 50 kv Corona (extinction) 11 kv 19 kv 26 kv Low frequency dry flashover 80 kv 110 kv 125 kv Low frequency wet flashover 60 kv 85 kv 100 kv Leakage distance 16.4 24.5 35.3 Dry arc distance 8.8 12.6 16.3 Overall height 13.2 16.7 20.8 1 15-kV and 35-kV sensor ratings are minimum design values. Exact values may vary slightly. Mechanical For vertical mounting only. Cantilever strength (ultimate) 2,800 lbs. Insulation Class 15 kv 25 kv 35 kv Weight, lbs. 39 49 59 Shipping Weight, lbs. 44 54 64 Current Signal Output Ratio: 600 amperes: 10-Volt output. Output burden/load: output is matched to 10,000 ohm or greater. Accuracy: ±2%. Phase shift: 0 (nominal) ±1.5. Open circuit voltage: 10 Volt at 600 amperes line current. No calibration needed (unaffected by aluminum, copper, armor rod, conductor size, adjacent phases, line angle, or insulator contamination). Voltage Signal Output (optional) Ratio: 10,000: 1 for 15-kV and 25-kV sensors. Consult S&C for 35-kV ratio. Operating Environmental Characteristics Temperature: -40 C to +70 C. Conductor Diameter Range The two-sided keeper is made of galvanized ductile iron and can accommodate a 0.25-inch to 1.25-inch aluminum or copper conductor. Basic Construction The CS Series Sensor is molded from Polysil, a high dielectric strength, anti-tracking polymer concrete developed under EPRI (Electric Power Research Institute). 2 S&C Specification Bulletin 1061-31

S&C Sensor Cables For Junction Box-to-Current Sensor For Use with IntelliCap and IntelliCap Plus Catalog Numbers1 Length, Feet End One Connector End Two Connector Catalog Number 20 None None 007-000973-04 2-Pin 007-000767-03 30 None 2-Pin 007-000767-04 238050, 238160 35 None 40 None None 007-000973-03 2-Pin 007-000767-05 None 007-000973-01 2-Pin 007-000767-01 1 Refer to Specification Bulletin 1022-31 for S&C IntelliCap Automatic Capacitor Controls. Refer to Specification Bulletin 1023-31 for S&C IntelliCap Plus Automatic Capacitor Controls. 50 None None 007-000973-02 2-Pin 007-000767-02 S&C Sensor Cables For Control-to-Current Sensor For Use with IntelliCap Plus Catalog Number1 Length, Feet End One Connector End Two Connector Catalog Number 20 007-000261-04 35 007-000261-05 238160 40 3-Pin 2-Pin 007-000261-01 1 Refer to Specification Bulletin 1022-31 for S&C IntelliCap Automatic Capacitor Controls. Refer to Specification Bulletin 1023-31 for S&C IntelliCap Plus Automatic Capacitor Controls. 50 007-000261-03 60 007-000261-02 S&C CSV Cable For Connecting CSV Sensor to Junction Box Length, Feet End One Connector End Two Connector Catalog Number 20 4-Pin None 904-001155-01 S&C Specification Bulletin 1061-31 3

14.4-kV Line-Post Current Sensor NOTE: Line post current/voltage sensor is similar. Dimensions in inches 4 S&C Specification Bulletin 1061-31

25-kV Line-Post Current Sensor NOTE: Line post current/voltage sensor is similar. Dimensions in inches S&C Specification Bulletin 1061-31 5

35-kV Multi-Core Line-Post Current Sensor NOTE: Line post current/voltage sensor is similar. Dimensions in inches 6 S&C Specification Bulletin 1061-31