FAST-STAT. Model 7000 Installation Instructions. Application. Fossil Fuel / Supplemental Controller. Before Installing This Product

Similar documents
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.

General Information. Do programmable thermostats really save energy?

INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER

, User s Manual

CONTROLS KITS AND ACCESSORIES /2014 Supersedes10/2014

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

INSTALLATION AND OPERATION MANUAL

Nest Learning Thermostat Pro installation & configuration guide

Digi-Motor Installation Guide

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Installation Questions

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

INSTALLATION & SERVICE MANUAL. Display Panel

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Failure code manual. content

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

E2 Series Electric Furnaces

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

T-100-R Installation Guide

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

HM-W536 Install Guide

PUSH BUTTON START INSTALLATION MANUAL

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

WHITE-RODGERS COMFORT-SET 90 SERIES

Professional Contractor INSTALLATION GUIDE

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

Customized Assessment Blueprint

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Installation Instructions

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

1 For All Non-Programmable Digital Thermostat

WHOLESALE DIRECT INC WEST 65TH STREET

Wiring Diagram. Diplomat 400V 3N.

NIPSCO AIR CONDITIONER (AC) CYCLING PROGRAM. Frequently Asked Questions. 1. Can I really make a difference by participating?

Electronic Power Control

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

SYSTEM 45. C R H Electronics Design

INSTALLER S & OWNER S MANUAL

Model 201 Wiegand Touchpad Reader Installation Guide

For Models #6-5001, #6-7501, # & #10-12K1

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Fossil fuel heating equipment

FAN-PWM-V3. Instructions

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

SECURITY SYSTEM ADP-CAN

PANASONIC TROUBLE SHOOTING GUIDE

Field Commander Wiring Manual

INSTALLATION GUIDE OWNER S GUIDE

Single Zone LCD Thermostat Operating Instructions

Technical Information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

How To Control A Thermostat

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

Service manual. The voltage in P3 and P4 in outdoor PCB is high voltage about 310V The voltage in P5 and P6 in outdoor PCB is high voltage about 310V

INSTALLATION GUIDE OWNER S GUIDE

HEAT SIPHON ANSWERBOOK

Digital Keypad Use s Manual

1F Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Integrated Metering Systems, Inc.

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P


Installation Guide. Programmable Thermostat TH6220D

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

Install Guide CT101. Caution. Caution

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

TMS TANK MANAGEMENT SYSTEM

1F /1/1 Day Programmable. 1F Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1

CT3200 Programmable Thermostat

User s Information/Installation Instructions

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

HEAT PUMP PROGRAMMABLE THERMOSTAT

ACS-30-EU-EMDR-10-MOD

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.


Install Guide 3M-50. Caution. Caution

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Air conditioning, electrical testing

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Commercial Refrigeration Temperature and Defrost Controls

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Transcription:

FAST-STAT Model 7000 Installation Instructions Application The FAST-STAT Model 7000 is designed to reduce installation time when converting from an air conditioner to a single or 2- stage heat pump. Before Installing This Product 1. Read Instructions. If you have any questions please contact our tech support line 2. This product is designed for use only on 24-volt AC circuits supplied by a Class 2 transformer. 3. This product is only to be installed by qualified technicians. 4. To avoid risk of electrical shock or equipment damage, disconnect power before beginning installation. Sender Installation The sender is installed in the wall space behind the thermostat. Enlarge the opening around the thermostat cable so that the sender can be inserted into the wall cavity. Trim the lead ends as required to fit the sub-base terminals but avoid cutting large amounts off. Use the included wire nuts to connect the sender to the thermostat cable. Once the connections to the cable and thermostat are completed, insert the sender into the wall cavity. The sender hangs by the leads and does not require any mounting. In certain modes of operation, the sender will produce a small amount of heat. To prevent this from affecting the thermostat it is advisable to have the sender as far as possible from the thermostat. This is achieved by having the sender leads as long as possible. Any unused leads should be taped back. Module Installation The furnace / air handler module is normally mounted inside the cabinet of the furnace near the other controls. If there is no space inside the cabinet, the module may be located in any dry location without exposure to high temperatures. The heat pump module is mounted in a dry location inside the heat pump cabinet near the other controls. The heat pump module is not rated for direct exposure to outdoor conditions. Do not mount it outside of the heat pump cabinet. Wiring There are two installation methods. One is the grounded commons method and the other is the two transformers method. In most installations the grounded commons method provides for the quickest installation. If this method is unsuitable then the two transformers method can be used. When installed with a fan that has more than two speeds, connect the G (green wire) on the furnace / fan-coil module to the Y1 (1 st stage cooling) terminal on the furnace or air handler. The Y2 (brown wire) is connected to the Y2 (2 nd stage cooling) terminal without change. All red wires are interchangeable and all black wires are interchangeable. The power supply must be between 20 to 28 volts for proper operation. The total connected load must not exceed 2 amps for each module. The connected load cannot operate at a voltage of more than 30 volts (not intended for line voltage control). Fossil Fuel / Supplemental Controller The two grey wires on the heat pump module may be connected to a remote bulb type thermostat to operate the built-in fossil fuel / supplemental heat controller. The use of this controller is optional When set for fossil fuel mode, a temperature drop to the set point of the heat pump thermostat will shut off the compressor and the indoor unit heating system will start. When the temperature rises above the set point, the indoor unit heating system will shut off and the compressor will start. When set for supplemental heat mode, the compressor will continue to run and the indoor unit heating will start when the temperature drops to the set point of the heat pump located thermostat. The grey wires are connected to the thermostat terminals that make when the temperature falls to the set point.. On the heat pump module there is a loop of purple wire. This loop of wire is cut if the heat pump has a cool active reversing valve. Tape back the leads after cutting. This is required only if the optional use heat pump located thermostat is installed for fossil fuel or supplemental heat operation. On the heat pump module there is a loop of green wire. This loop of wire is cut if the unit is to function in fossil fuel mode. Tape back the leads after cutting. If the green loop is left intact, then it will operate in supplemental heat mode. This is required only if the optional use heat pump located thermostat is installed for fossil fuel or supplemental heat operation Start Up Testing 1. Set the thermostat to fan manual on. The fan will start. Set the fan mode selector switch to auto mode. The fan will shut off. 2. Set the thermostat so that it will call for the indoor unit heating system to start. This is usually backup or emergency heat. The indoor unit heating system will start. Return the thermostat to the off position. The indoor unit heating system will shut off. 3. Set the thermostat to a call for cooling. The fan and compressor will start. Depending on the type of heat pump the reversing valve may energize. Set the thermostat to off. The fan and compressor will stop. 4. Set the thermostat to a call for heat. The fan and compressor will start. Depending on the type of heat pump the reversing valve may energize. Set the thermostat to off. The fan and compressor will stop. Page 1 of 6 Specifications subject to change without notice Nordic Technology Ltd www.fast-stat.com

Transformer Test Only required if the two transformer method is used. At the Thermostat 1. Set the thermostat so that the heat pump is running in heating mode. For two-stage heat pumps the compressor must be running in high speed. At the Heat Pump 2. Manually set the heat pump into defrost mode (see heat pump manual for instructions on how this is done). 3. Check to determine if the indoor unit heating is on. If it is on then this test is completed and no further action is required. If the indoor unit heat is not on then proceed to step 3 below. 4. If the indoor unit heat will not start when the heat pump is in defrost mode then the heat pump transformer and indoor unit transformer are connected in series when they need to be connected in parallel. Shut off the heat pump and switch the secondary leads of the heat pump transformer. Retest starting at instruction #1 above. Purpose of the transformer test The purpose is to insure that the indoor unit transformer and the heat pump transformer are connected in parallel. If they are in parallel then the indoor heating system will start when the heat pump is in defrost mode. If they are not in parallel (series connected) then the PTC (automatically resettable fuse) located in the heat pump receiver will trip. When it trips the signal from the heat pump that would start the indoor unit heating system cannot get through. No harm will occur to any part of the control system when this happens. All other functions will work properly when the transformers are series connected except that the indoor heating system will not start when the heat pump is in defrost mode. There is no easy method of determining transformer polarity when installing the heat pump transformer. There is a 50% chance of it being correct (or incorrect) when first connected. Switching the leads from the secondary side of the heat pump transformer will correct the problem. The PTC resettable fuse usually takes about 30 seconds to cool down and reset after being tripped. The PTC resettable fuse has to reset itself before the circuit can be tested. If equipped with a thermostat at the heat pump 1. Set the heat pump thermostat to a temperature setting at least 10 degrees colder than ambient. 2. Set the indoor thermostat to a call for heat from the heat pump. 3. With the heat pump running in heat mode, slowly adjust heat pump thermostat setting to above ambient temperature. If the heat pump receiver is set for fossil fuel operation then the heat pump will shut off and indoor unit will go into heating mode. If the heat pump receiver is set for supplemental heat then the heat pump will continue run while the indoor unit goes into heat mode. 4. Set the heat pump thermostat to the temperature at which either the heat pump is to shut off or supplemental heat is to be switched on. 5. Testing is now completed. Set indoor thermostat to desired settings. Troubleshooting 1. Check that there is a constant 24-volt power connected to the red and black leads of both the furnace module and the heat pump module. 2. Remove the thermostat from its sub-base. With a jumper, make a connection between R and Y1 on the thermostat terminal strip. The fan and compressor should start. If the fan and compressor start when a jumper is used but will not start when the thermostat is used, there may a set up or compatibility issue with the thermostat. If the fan and compressor do not start with a jumper proceed to step #3. 3. At the furnace module, disconnect the four wires connected to the thermostat cable. Join the furnace module red and purple wires together the fan and backup heat should start. Join the red and gray wires together the compressor, reversing valve, backup heat and high-speed fan should switch on. If the various functions can be switched on by this method then there may be a problem with the thermostat cable or the sender. If the indoor unit heating and fan switch on by this method but the outdoor unit does not start then go to step #4. 4. With the thermostat set so that the compressor should be on (high speed if 2-stage) and the reversing is on, measure the voltage between the orange and the common. If 24 volts is measured, then the wiring is correct up to the heat pump. If the heat pump will not operate proceed to step #5. 5. At the heat pump module disconnect the orange wire (connected to cable going to the furnace module). Join the orange wire to the transformer R. The compressor and reversing valve should switch on. If the compressor and reversing valve switch on by this method then check the cable and connections going to the indoor module. If the nothing starts then check that there is 24 volts coming from the transformer. If there is transformer power and the compressor and reversing valve will not start when jumped-out then there may be a problem with the heat pump module. Tech Support Line: 1-800-775-4750 ext. 3 Monday Friday: 8:30am to 4:30pm Pacific Standard Time Page 2 of 6 Specifications subject to change without notice Nordic Technology Ltd www.fast-stat.com

Page 3 of 6 Specifications subject to change without notice Nordic Technology Ltd www.fast-stat.com

Page 4 of 6 Specifications subject to change without notice Nordic Technology Ltd www.fast-stat.com

Model 7000 used to extend wiring from a indoor unit to a heat pump. 3-wire cable Thermostat Furnace / Air Handler Brown - not used - tape back Green - not used - tape back R C G W Y1 Y2 O/B R C G W Y1 Y2 White Yellow Brown Blue Gray Gray Purple Purple White - not used - tape back Green - not used - tape back - not used - tape back - not used - tape back Furance / Air Handler Module FAST-STAT For single-stage units join the Sender Brown & Yellow wires together onto the furance/air handler "Y" terminal Sender FAST-STAT Heat Pump Module Green - Cut for "Fossil Fuel" mode Purple - Cut for "cool active reversing valve" Not Used Blue Brown Yellow White Existing Condenser Cable OB Y2 Y1 W C R Reversing Valve Compressor Stage 2 Compressor Stage 1 Defrost Heat For single-stage use, tape back brown wires on Sender and Heat Pump Module. Heat Pump Control Board Heat Pump Page 5 of 6 Specifications subject to change without notice Nordic Technology Ltd www.fast-stat.com

Purple Sender Yellow - Y1 Brown - Y2 White - W Inputs Green - G Blue - O/B - R - C Power Thermostat Cable To 24 volt power - R - C Purple Indoor Unit Module Control Brd Outputs Brown - Y2 Green - G White - W Heat Pump Cable Thermostat for dual fuel controller (optional use) To 24 volt power Outputs -R -C Yellow - Y1 Brown - Y2 Blue - O/B Control Brd Input White - W Outdoor Unit Module Page 6 of 6 Specifications subject to change without notice Nordic Technology Ltd www.fast-stat.com