CEMA. Engineering Standard Variable Frequency Drive (VFD) Selection For Screw Feeders

Similar documents
We will discuss common industrial applications with guides for the proper use of electric motors on these.

Specifying a Variable Frequency Drive s

Centrifugal Fans and Pumps are sized to meet the maximum

Product Brochure. Controlled start transmission

The Technical Legacy of the CEMA Engineering Conference

Controlled Start transmission

Basic Nameplate Information

Design and Analysis of Screw Conveyor at Inlet of Ash/Dust Conditioner

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

Documenting Results to Validate Energy Savings Projects: Case Study of Direct Drive Cooling Tower Installations: Before and After

The Energy Independence and Security Act of The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010

Solving VFD-sourced Bearing Current Problems in AC Motors.

Energy Savings With Adjustable Frequency Drives. for Centrifugal Fans

Rotary Phase Converters

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

UM Series UniModule. Pre-assembled, C-face Clutches and Brakes. Original Design Sizes 210 & 215. GEN 2 Design Sizes 50, 100 & 180

COOLING TECHNOLOGY INSTITUTE

Chapter 4.5: Electric Motors, Variable Speed Drives

ENGINEERING BULLETIN No. EB 039 Product: Cooling Towers, Closed Circuit Coolers & Evaporative Condensers Date: June 2003

What Do All Those Things on an AC Motor Nameplate Mean?

Technical Guide No High Performance Drives -- speed and torque regulation

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Electric Motor Brake Horsepower Calculations

Motor Specifications. Nameplate

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

ADJUSTABLE FREQUENCY DRIVES APPLICATION GUIDE

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

Introduction. Upon completion of Basics of AC Motors you should be able to:

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

Electric Motors and Drives

Model No. 4 Vertical Mixer 9 Screw Feeder Inlet H15400, May 1999 (# )

AC Kinetics Variable Frequency Drive Comparative Transient Inertial Testing. This document was prepared by Advanced Energy.

Chapter 3.5: Fans and Blowers

The Ultimate Truck Stock Motor

DESIGN AND SIZING OF SCREW FEEDERS. By Marco Bortolamasi Johannes Fottner

Providing Answers For All Your Machine Tool Needs

Unit 33 Three-Phase Motors

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Fundamentals of Inverter Fed Motors

GE Industrial Systems. AC Motor Selection and Application Guide

BALL & ACME LEAD SCREW TECHNICAL INFORMATION

5 or 12 yard capacity SOLID PRODUCTS. SOLID PERFORMANCE.

TABLE OF CONTENT

300 Series PA Pump and Cooler Assemblies

TECHNICAL INFORMATION Bulletin

Tips For Selecting DC Motors For Your Mobile Robot

Unidrive M Energy Savings

Permanent Magnet Technology within Direct Drive Cooling Tower Motors Creates System Energy Savings

Current Transformers

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

Installation Manual Version 7.3 IMPORTANT:

Diesel Engine Driven Generators Page 1 of 6

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

Data Center. Ultra-Efficient chilled water system optimization. White paper. File No: Date: december 03, 2015 Supersedes: new Date: new

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

Application Note AN-SERV-006

Baldor Electric ProSPEC MASTERFORMAT SPECIFICATION May 3, A. This specification covers integral horsepower squirrel cage AC induction motors.

The Right Drive to Maximize Efficiency and Production for Large Overland Conveyors

Drives Low Voltage. Adjustable Frequency. Adjustable Frequency Drives Low Voltage Contents

General Information. ME-business can be accessed through: www. marathonelectric.com.

TECHNICAL INFORMATION Bulletin

GE Industrial Systems. AC Motor Selection and Application Guide

Installation & Operation Manual Dial-A-Flow Adjustable Frequency Drives

VARIABLE FREQUENCY DRIVES THEORY, APPLICATION, AND TROUBLESHOOTING

BUT PRECAUTIONS MUST BE TAKEN OR SERIOUS BURNS CAN RESULT.

FREQUENCY CONTROLLED AC MOTOR DRIVE

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Voltage Drop. Voltage Drop 1

Servo Motor Selection Flow Chart

APPLICATION GUIDELINE FOR ELECTRIC MOTOR DRIVE EQUIPMENT FOR NATURAL GAS COMPRESSORS

2015 EPO No. 14. Examination Procedure Outline for. Belt-Conveyor Scale Systems

WINDER SYSTEMS GE Industrial Control Systems

32VFD Variable Frequency Drives for Centrifugal Chillers

DIRECT CURRENT GENERATORS

Application Information

Evaluation Report CCMC R Pieux Vissés Vistech / Postech Screw Piles

Understanding Variable Speed Drives

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

QSV Series Vacuums an EnPro Industries company QUINCY QSV SERIES ROTARY SCREW VACUUM PUMPS 7.5 HP TO 200 HP

NEW CONVEYOR EQUIPMENT Parts & Services

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

(3) Explosion proof. Designed to prevent ignition of any explosive gases or dust and dirt which may surround the motor.

AC Electric Motors best practice

AC Induction Motor Slip What It Is And How To Minimize It

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

PowerFlex Dynamic Braking Resistor Calculator

I hope you find them useful and I would appreciate any comments or thoughts you might have for future improvements, corrections or topics.

How To Save Energy On A Power Supply

Variable Frequency Drive For use with Block Machines

Storage and Handling Requirements for Biomass. Richard Farnish, CEng MIMechE

Section 10. Application Manual for NEMA Motors. Special Applications

ETZGAR CONVEYOR COMPANY Controls Section v12.05

Motor Protection Voltage Unbalance and Single-Phasing

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

WIND TURBINE TECHNOLOGY

Transcription:

CEMA Engineering Standard 351-2007 Variable Frequency Drive (VFD) Selection For Screw Feeders Approved: September 19, 2007 Published by the CEMA Screw Conveyor Section as a service to the conveying industry. Conveyor Equipment Manufacturers Association 6724 Lone Oak Blvd. Naples, Florida 34109 www.cemanet.org

CEMA ORGANIZATIONAL CHART COMMITTEES BOARD OF DIRECTORS OFFICERS Conference Finance and Budget General Bulk Handling Section Meet in March and/or September Unit Handling Conveying Section Strategic Planning Insurance Bulk Handling Components and Systems Screw Conveyors Bulk Accessories Controls Conveyor Chain Palletizers Meetings MeetsEach June Membership Engineering Conference Accessories Past Presidents Public Relations Committees Idlers Pulleys Statistics Conveyor Chain Performance Terminology Unit Handling Standards Unit Handling Section Bulk Handling Section Screw Conveyors Belt Systems Safety Controls Terms and Definitions International Standards Belt Manual DISCLAIMER The information provided in this document is advisory only. These recommendations are provided by CEMA in the interest of promoting better engineering approaches to certain equipment applications. Any use of this document, the information contained herein, or any other CEMA publication may only be made with the agreement and understanding that the user and the user s company assume full responsibility for the design, safety, specifications, suitability and adequacy of the system component, or mechanical or electrical device designed or manufactured using this information. The user and the user s company understand and agree that CEMA, its member companies, its officers, agents and employees shall not be liable in any manner under any theory of liability for the user or user s reliance on these recommendations. The users and the user s company agree to release, hold harmless and indemnify CEMA, its member companies, successors, assigns, officers, agents and employees from any and all claims of liability, costs, fees (including attorney s fees), or damages arising in any way out of the use of this information. CEMA and its member companies, successors, assigns, officers, agents and employees make no representations or warranties whatsoever, either express or implied, about the information contained in this document, including, but not limited to, representations or warranties that the information and recommendations contained herein conform to any federal, state or local laws, regulations, guidelines or ordinances.

CEMA Engineering Standard 351-2007 Variable Frequency Drive (VFD)Selection For Screw Feeders Screw feeders are designed to operate under flooded conditions with a head load of product on the screw or multiple screws. The unit must be designed to overcome the static condition of the screws and the force exerted by the product head load. The product head load exerts a downward force on the screws and creates frictional resistance. As a result, additional torque is required to start and operate a screw feeder when compared to a screw conveyor. Special consideration is required when designing screw feeders. The starting torque requirements of screw feeders can be as much as 2-1/2 times the demand running torque. Torque is a function of horsepower and speed. Most screw feeders for industrial applications operate at speeds below 30-rpm. The lower screw feeder speed provides higher torque at the drive shaft. Screw feeders are volumetric metering devices. A fixed volume of product is discharged with each revolution of the screw. The volumetric capacity of the screw feeder is based on the volume available in the last pitch before the shroud and the speed of the unit. All calculations are based on the capacity given in cubic feet per hour. Procedure for Calculating Demand Horsepower for Screw Feeders 1. Perform screw feeder speed calculations for normal operating conditions to determine operating speed at the desired capacity, lowest density, degree of incline and screw pitch. Set the trough loading to 95-percent. Be sure to use the speed calculated for the appropriate housing style if the screw feeder is inclined. 2. Perform screw feeder horsepower calculations for worst-case operating conditions using the highest density and the volumetric capacity in cubic feet per hour as calculated in step 1. The screw feeder speed must be the same as calculated in step 1. The inlet length, head load height, product angle of repose and flight design must be taken into consideration to determine the demand horsepower requirements. 3. Perform screw feeder horsepower calculations with a range of material factors to determine high and low reference points for demand horsepower. The product will increase in density when stored in a hopper or silo due to compression. The material factor of the product will increase as the density increases. For example, if the average material factor for a product is 2.0, then perform horsepower calculations using material factors of 2.0, 3.0 and 4.0. Typically, the demand horsepower will not exceed the calculation using a material factor of 4.0. Procedure for Determining Inverter Size for Screw Feeders (Standard is based on 230/460-volt, 3-phase motors) 1. Determine the Motor Base Speed. The motor base speed is determined by selecting a motor and gear reducer ratio that delivers the desired speed at the drive shaft of the screw feeder. Motors with 1800-rpm base speeds are most common in the U.S. 1200 and 3600-rpm motors are also available. Most commercially available industrial motors used in screw feeder applications are NEMA Design B motors. Depending on the horsepower and base speed, a NEMA design B motor can generate up to 275-percent of the nameplate rated torque at start up when started at full voltage across the line. Please refer to Figure 1 below. The same motor started on a VFD will 1.

CEMA Engineering Standard 351-2007 deliver torque at either the current overload of the VFD or the breakdown torque of the motor, whichever is lower. Figure 1. (Courtesy of Baldor Dodge Reliance) 2. Determine the Turndown Ratio. The desired operating range of the screw feeder is based on the given customer s requirements. If the customer would like to meter anywhere from 100 to 1,000 cubic feet per hour of product, then in this example the turndown ratio of the motor is 10-to-1. The screw feeder speed and horsepower should be calculated for the maximum feedrate or worst-case operating conditions at motor nameplate frequency. 3. Determine Motor Type. It is important to select a motor that is capable of running with constant torque over the required speed range. Most standard TEFC motors are capable of either 4-to-1 or 10-to-1 turndown ratios on a constant torque load. Normally, to get higher turndown ratios, motor manufacturers have designed motors with cooling independent of motor speed with the use of auxiliary cooling fans. Motor manufacturers have also developed motors that are capable of developing constant torque from zero speed up to base motor speed. 4. Determine the VFD Size. The VFD must be sized for at least 2 times the full-load amps of the motor to allow for the high inrush of current during screw feeder starting. For example, a typical 20-hp premium efficient motor is rated for 49-amps at full-load and 230-volts. A minimum of 98-amps are required for sizing the VFD for start up conditions. Most VFDs limit the current output to 150-percent of full-load amps because torque and current are not proportional above 150-percent torque. A typical 20-hp VFD is rated for 1.5 times full-load amps or 74-amps and is not sufficient for the application. A typical 30-hp VFD is rated for 108-amps at 230-volts. The minimum VFD size would be 30-hp. A 40-hp VFD would be recommended. 5. Program the VFD. The VFD must be programmed for full torque boost with the least amount of time delay at start up. The time delay limits the inrush of current and creates a soft start. Soft starting a screw feeder under load is not recommended. The VFD soft-start feature must be disabled. 2.

CEMA Engineering Standard 351-2007 Other Factors to Consider 1. All motors are constant horsepower and variable torque above base speed. A motor can only generate nameplate horsepower up to base speed because the voltage is fixed by the power source. As motor speed increases above nameplate frequency it becomes constant horsepower and variable (decreasing) torque. Since the horsepower is fixed, the torque of the motor will decrease as the speed of the motor is increased. Please refer to Figure 2 below. Maximum motor speed is limited by rotor balance, bearing life, overheating and other physical limitations of the motor. Figure 2. (Courtesy of Nord Gear) 2. Alternate methods for determining screw feeder horsepower and VFD size are used by manufacturers. Some manufacturers choose to oversize the motor instead of the method described above. A successful method for determining screw feeder horsepower is to multiply the demand horsepower calculated at the minimum capacity by the turndown ratio and again by 2.5 to allow for start up conditions. This is a conservative method for determining screw feeder horsepower and the equipment must be sized for full-motor torque. 3. This Engineering Standard is a guide for manufacturers and users of screw feeders for the metering of bulk materials. The intent of the standard is to provide information to aid in the proper design and operation of screw feeders. Each manufacturer may have internal standards for designing screw feeders that are based on independent experience and research. Their internal standards may differ from the CEMA standard but provide similar results. Please consult a CEMA screw conveyor manufacturer for further information. Note Special thanks to Nord Gear and Reliance Electric for assistance in creating this standard. 3.