High Rise Fire Safety. Guidance Documents

Similar documents
SPECIFIC GUIDANCE FOR A HOUSE IN MULTIPLE OCCUPATION (HMO) CONVERTED ENTIRELY INTO SELF CONTAINED FLATS

Northern Ireland Housing Executive: HMO Fire Safety Guide

Fire precautions in dwellings. Private sector housing Providing homes building communities

Fire Safety in High Rise Residential Blocks

Introduction. CE marked construction products

3.In making the following determination, the Secretary of State has not considered whether the plans conform to any other relevant requirements.

REVIEW ON FIRE REGULATIONS FOR NEW HIGH-RISE COMMERCIAL BUILDINGS IN HONG KONG AND A BRIEF COMPARISON WITH THOSE IN OVERSEAS

Using Sprinkler Systems in Buildings and Structures Compliance with current fire safety guidance

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

HOUSES IN MULTIPLE OCCUPATION STANDARDS. Housing Executive

For use by landlords of small premises Premises Address

For use by landlords of small premises Premises Address

- 5 - Table1. Maximum Compartment Volumes

Fire Safety Challenges and Solutions. Claire Guise Health and Safety Manager

Building Control Guidance Note

FIRE RISK ASSESSMENT SW13 0HA

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

ON MOST schemes, the architectural design of. Flexible strategy. Case study. The Forum

Fire Strategy. Oak Park Care Home and Extra Care Block. 21 July 2015

Extracts from BUILDING REGULATIONS

Guidance on loft conversions in two-storey houses

Fire. The Fire Installers Mate. A guide to fire alarm systems design

BUILDING PERMIT SPECIFICATIONS

FIRE ESCAPE SIGNS Guidance on compliance

Grasshoppers Rugby Football Sports and Social Club. The Fire Risk Assessment

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

Additional Guidance. for application to. HM Government Guide to Fire Safety Risk Assessment Residential Care Premises

Decree of the Ministry of the Environment. on fire safety of garages

Fire Risk Assessment for

Fire safety guidance in purpose-built blocks of flats. Background to the project why a new guide? Background to the project why a new guide?

Contents. 1. Introduction 1.1 Reason for this Guide Interpretation 1.3 Principles of Fire Safety 1.4 Legal Provisions 4

FIRE DETECTION AND ALARM SYSTEMS

Fire Safety Risk Assessment Checklist for Residential Care Premises

Building Control Guidance Note

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

Fire Safety In High Rise Building

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

New York City Department of Buildings

NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02

UPP Residential Services Fire Risk Assessment

Fire Risk Assessment. John Revington

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER May 2015

London Borough of Barnet. Fire Safety in Houses in Multiple Occupation. A Guide to Landlords

Fire Evacuation Procedures Network Building, 97 Tottenham Court Road, London, W1

Fire safety advice for landlords

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

How To Write A Fire Risk Assessment

Guide to Houses in Multiple Occupation Self Contained Flats

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

A study of the nature of fire risks in tall buildings

Fire safety in purpose-built blocks of flats

Protection from falling. collision and impact. The Building Regulations edition for use in England* ONLINE VERSION APPROVED DOCUMENT

Fire Risk Assessment For Simple Premises

ONLINE VERSION ONLINE VERSION

CITY OF LONDON SCHOOL FOR GIRLS FIRE SAFETY, PROCEDURE AND RISK ASSESSMENT POLICY


FIRE RISK ASSESSMENT

I.S :2013 Fire Detection & Alarm Systems

Code Requirements for Existing Buildings

FIRE-FIGHTING DESIGN BRIEF REPORT

It is against this refusal that the appellant appealed to the Secretary of State.

Proposed Residential Complex At Holding No. - 98, B.T. Road, Kolkata Developer Premier Mica Mining And Manufacturing Company

The terms hazard and risk are often used, which we define as the following:

Residential Plan Routing Information

Refuse and Recycling Advice note For Developers. September 2015

I.S :2013 Fire Detection & Alarm Systems

Houses in Multiple Occupation

Waste management guidance notes for residential developments

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

Fire risk assessment a guide for businesses

How To Build A Basement House

Concord Department of Fire and Life Safety FIRE MARSHAL S OFFICE

City of Bettendorf Fire Alarm System Requirements

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3

FIRE SAFETY PRINCIPLES FOR RESIDENTIAL ACCOMMODATION

COMMONLY USED RESIDENTIAL BUILDING CODES

ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website

BS9999 and FRAME. FRAME and BS 9999

Guidance on the Preparation of an Access Statement

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

Fire safety ONLINE VERSION APPROVED DOCUMENT VOLUME 2 BUILDINGS OTHER THAN DWELLINGHOUSES ONLINE VERSION. The Building Regulations 2010

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

I strongly urge providers of pre-school services to study and apply the guidance contained in this publication.

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

The risk assessment of fire damper installations

St. John s University

Housing Act 2004 Regulatory Reform (Fire Safety) Order 2005 Fire Safety in Purpose-Built Flats Have you taken sufficient action?

Overview of Hotel Fire Safety Requirements

Fire Safety Management Strategy

REFUSE AND RECYCLING STORAGE REQUIREMENTS

To promote and protect the private residential landlord. Fire Safety Logbook. Information. Advice. Support. Services START DATE:

Law No. (9) of 2012 Amending some provisions of Law No. (13) of 1997 Concerning the Civil Defense

RESIDENTIAL WINDOW REPLACEMENT

FIRE RISK ASSESSMENT WORKED EXAMPLE

Generic Risk Assessment for use of Residential Accommodation. Visual inspection of fire escapes, alarms, equipment, meeting point and procedures.

Firefighter Review. Instructor Guide

FIRE SAFETY RISK ASSESSMENT

Fire Safety Regulation, a comparative perspective, Ireland v Poland. Piotr Smardz

Building Regulations Technical Guidance Document B

Transcription:

High Rise Fire Safety Appendix B Guidance Documents Introduction Prior to 1991, the guidance for fire safety in blocks of flats was provided by CP3 Chapter 4, first published in 1948 and based on Post War Building Studies 1946. After the war it was acceptable for residential blocks of flats to be served by a single protected stairway. The individual flats were also provided with an escape balcony and, provided that the balcony was no higher than 14 yards above ground level (the height of fire brigade ladders), the corridors giving access to the flats from the single stair could be over 12m in length. In practice, single direction corridors of 24m were not uncommon. In the 1950s and 1960s blocks of flats became taller and taller without a great deal of change to the internal layout. It is for this reason that the internal design for Lakanal House included corridors of 24m from a single escape stair with escape balconies for each flat, including the 15 th floor flats. At the time, architects questioned the wisdom of this venture, but at that time the codes of practice were guidelines only, and did not have the same power as formal regulations. The CP3 guidance document was revisited and in 1975 it gave firmer guidelines with regards to blocks of flats, very similar to the guidance that we know today. In 1985 the first Building Regulations Approved Document B was published. This had greater power because it was linked to formal regulations, but unfortunately it did not cover blocks of flats. In 1990 BS 5588:Part 1 was published. This document picked up on the essential elements of CP3 Chapter 4 and formalised them as a British Standard in order to promote consistence of standards within the UK. In 1991 the AD B was reviewed, and on this occasion it copied and pasted the 1975 edition of CP3 and included it completely without amendment. The Approved Document was modified further in 2002, and again in 2007. The 2002 edition did not change the guidance with regards to the common s of blocks of flats, and nor did the latest edition. The only change that the 2007 edition made is with regards to fire alarm systems within the dwellings themselves. The CLG Sleeping Guide recognises the 1991 edition of AD B as the benchmark. It directs the reader to assess the risk and provide appropriate levels of fire protection. It goes on to outline the general principles of

protection expected for a normal risk premises. It does not differ greatly from AD B in many s, but it requires a fire alarm system in the common s to compensate for the s in which it does differ. The Local Authorities Coordinating Office on Regulatory Services (LACORS) also recognises the 1991 edition of AD B as the benchmark for flats. It recognises that not all flats have been built with fire resisting floors, and are not suitably covered by ADB or the Sleeping Guide. It therefore offers alternatives to address these shortfalls. All four guides seek to provide the same level of safety as that originally intended in the 1975 edition of CP3, which appears for the most part to have stood the test of time. The BS 5588 series has been superseded by BS 9999 for the most part, with the exception of Part 1. BS 5588: Part 1 is still referred to within AD B, and the contents have not been mapped across to the new BS. It is understood that the British Standards Institute is seeking to re-badge this part under a new number so that it continues to stand alone. Whether the re-badging takes place or not, the standard is still very useful to inspectors. Not only does it provide the requirements to meet the standards, but also gives the rational behind those requirements. The purpose of this paper is to look at the standards required to protect the common s in blocks of flats, and to assist inspectors in understanding how the guidance documents work to achieve a similar standard. 2

Approved Document B BS 5588: Part 1 CLG Sleeping Guide Lacors - 6 Storey Compartmentation: <18m 18-30m >30m Between Dwellings Maintained to AD B Between Dwellings and Means of Escape Between Floors Refuse Storage Chamber Enclosing Means of Escape Enclosing Lift Shaft Enclosing Service Shafts If lower than AD B, basement floors should be at least 60 mins FR alternate and upper sleeping floors floors (incl. basement) should be separated by at least FR. Fire Doors Dwelling Entrance Enclosing Means of Escape Cross Corridor Doors Hold Open Devices Letter Openings FD30 S FD30 S FD30 S FD30 S FD30 S FD30 S FD30 S FD30 S FD20 S FD20 S FD20 S Not restricted if door is considered a hindrance Cross-Corridor doors only To be avoided if possible. If unavoidable 1.1m from floor (within the neutral plane) Not restricted if door is considered a hindrance

Fire Alarm Common Area Operation of AOV Operation of electro magnetic door holder Travel Distance from Dwelling to Stair Single Direction Alternatives Available Unnecessary and Undesirable 7.5m from dwelling door 30m from dwelling door Unnecessary and Undesirable 7.5m from dwelling door 30m from dwelling door Grade A LD2 if premises not to AD B Standard 18m incl. flat interior 7.5m max in corridor 35m including flat interior Grade A LD2 Must not be excessive Must not be excessive Ventilation Dead End Alternative Routes Available Stairways AOV 1.5m 2 AOV 1.5m 2 AOV OV OV Stairways Minimum Width 1.0m 1.0m 1.05m Min Width if Fire-fighting Shaft 1.1m 1.1m Not Specified N/A External Openings in Stairway 1.8m Rule 1.8m Rule 1.8m Rule 1.8m Rule Stores Opening Onto Acceptable if Fire Stairway Not Permitted Not Permitted Resisting Construction 4

Single Stairway Multiple Stairs Building Height >18m Building Height >60m or Ancillary Parts 1x Cannot serve basement. Cannot serve ancillary parts on same floor as dwelling or Ancillary Parts 1x Cannot serve Basement. None can serve Ancillary Parts Should not serve basement Wet Rising Main Wet Rising Main Not Specified N/A Ancillary parts separated by 60 mins FR Ancillary parts separated by 60 mins FR N/A Escape Lighting Fire Fighting Equipment Required in all common escape routes Not discussed Where Necessary Where Necessary Where Necessary Yes if free from vandalism Open to interpretation. Advice from D Stotesbury Simple multi-purpose extinguisher on each floor 5