Furman Model IT-2315 Balanced Isolation Transformer

Similar documents
LOXONE 12 Channel Amplifier

Pf-pro E Features. Pf-pro r E additional Features

Balanced vs. Unbalanced Audio Interconnections

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Congratulations! Thank you!

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

MODEL 2202IQ (1991-MSRP $549.00)

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

CX Zoner Installation & User Guide

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

AC Direct Off-Line Power Supplies

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

PAL to NTSC (NTSC to PAL) Converter with 19 inch Rack (CDM-640AR)

Antec TruePower User's Manual

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

HP UPS R1500 Generation 3

IMPORTANT SAFETY INSTRUCTIONS

Power Supply Specifications

F(t) Forssell Technologies Inc

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

The Dangerous Monitor Manual

INSTALLATION & SERVICE MANUAL. Display Panel

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

Specifying a Variable Frequency Drive s

Powerware 5110 UPS User s manual

Grounding Demystified

S/PDIF D/A Converter. User Manual. Rev.B, December 2011 Audial d.o.o Belgrade, Serbia

1 All safety instructions, warnings and operating instructions must be read first.

STEREO PREAMPLIFIER INSTRUCTIONS FOR USE

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

DC POWER SUPPLY ALIMENTATION C.C.

HP R12000 and R18000 DirectFlow UPS User Guide

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

Tone Hammer 500. Owners Manual. Manual Version 1.0

MIDI control allows the Split Personality to be used remotely in rack systems, or integrated into MIDI controlled setups for easy preset recall.

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Three-Phase Electric Power Distribution for Computer Data Centers

Applied Electronics. Commercial Dimming System UPDATE NOTICE

ELECTRICAL AUDIO EApreq

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac

Replacing the vacuum tube

PERF10 Rubidium Atomic Clock

ST Series POWER SUPPLIES USER INSTRUCTIONS

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Line Level Converter Box. S Class Signal Processors

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Bypass transfer switch mechanisms

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

To reduce the risk of electrical shocks, fire, and related hazards:

Perseus. Owner s Manual. Vacuum Tube Preamplifier. Rogue Audio, Inc. 3 Marian Lane Brodheadsville, PA Issue date: 02/01/06

CV-5000 HEAVY DUTY PROFESSIONAL AMPLIFIER

I STAR COMPUTER CO., LTD

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

750VA/1000VA/1500VA 100/120/230VAC 2U

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Line Reactors and AC Drives

Installation and Operation Back-UPS 1250, 1300, 1500

PSP3. Stereo M/S preamplifier. User manual

TOA 900 SERIES II MIXER POWER AMPLIFIER

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

Application Note. Troubleshooting Communications

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

3 Slot Payphone Controller

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

Operation and Installation Manual

Features, Benefits, and Operation

User Manual Wohler Technologies Inc. ALL rights reserved ECO-2668 (10/13/04)

Zone Mixer. 6 channels configurable from 24 inputs. 3 zone outputs. Expandable via Sys-Link TM Built-in comp/limiter, ducking and alarm functions

Current Transformers

Agilent 87421A/87422A Power Supply

Back-UPS Pro 1300/1500 Installation and Operation

Brio-Rmanual:Cursamanual.qxd 08/04/ :25 Page1

Rack mounted telephone- and leased line modem for industrial applications

Safety Warnings and Guidelines

EKOS Cart. Instructions for Use

Current Probes. User Manual

INSTRUCTIONS FOR USE Pro-Ject Tube Box S

User Manual. English. APC Smart-UPS VA 120/230 Vac VA 100/120/208/230 Vac. 2U Rack Mount Uninterruptible Power Supply

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

Telephone- and leased line modem for industrial applications TD-36

WHOLESALE DIRECT INC WEST 65TH STREET

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

user guide Meridian 558 Multi Channel Power Amplifier

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

StorTrends 3400 Hardware Guide for Onsite Support

White Paper: Electrical Ground Rules

Transcription:

Furman Model IT-2315 Balanced Isolation Transformer Furman Sound, Inc. 1997 South McDowell Blvd. Petaluma, California 94954-6919 Phone: 707-763-1010 Fax: 707-763-1310 Web: http://www.furmansound.com e-mail: info@furmansound.com

The following variations on the Model IT-2315 may be obtained to satisfy the current and voltage specifications required for international use: Table 1 Current ratings for international versions of the IT-2315 Model Current (A) Voltage (V) IT-2315B, IT-2315I, IT-2315F 15 230 IT-2315U 13 230 IT-2315S 10 230 IT-2315A* 15 240 *The IT-2315A draws 15 A from the mains but supplies 10 A to each outlet. Features IT-2315 Schuko (most of Europe) IT-2315F France Belgium IT-2315U Ireland United Kingdom IT-2315A New Zealand Australia IT-2315S Switzerland Figure 1 Optional outlet configurations IT-2315I Italy IT-2315B British Commonwealth India, Central & South Africa Tightly balanced, isolated, AC power for ultra-low-noise installations. Available with seven outlet configurations to meet the requirements of almost every nation. Available in 10 A, 13 A and 15 A models (15 A typical). Typically provides a 16 db improvement in background noise floor. Toroidal transformer with center-tapped secondary is the most efficient and compact design, with minimal magnetic field leakage. Exclusive Soft Start circuit prevents turn-on transients and high inrush currents. Faraday shield reduces electrostatic coupling between primary and secondary. Extreme Voltage Shutdown circuit protects against dangerously high or low input voltages, such as accidental connection to 460 V. Microprocessor-controlled, smart AC voltmeter monitors line voltage and alerts the user to marginal and extreme voltage conditions, even when the unit is switched off (must be plugged in). Provides basic power conditioning functions like spike suppression and RFI filtering; dissipates spikes with a gas discharge tube. Current Fault Protection System prevents inadvertent shocks (equivalent to GFCI). CE and C-tic listed 2

Introduction Thank you for purchasing the Furman IT-2315 Balanced Isolation Transformer, designed to supply low-noise AC power for critical installations. It can supply up to 15 A of balanced AC power to a recording studio, video or film production facility, broadcast station, live concert venue, or home theater. Its main function is to drastically reduce hum and buzz caused by ground currents from power supplies and radiation from supply cables into sensitive signal sources like guitar pickups, tape heads, and microphones. The IT-2315 dramatically reduces the noise floor and significantly improves dynamic range and sonic clarity. The unit is housed in a 3-U rack-mount chassis and can be installed in just a few minutes. The heart of the IT-2315 consists of a specially wound and shielded, toroidal, isolation transformer with a center-tapped secondary. Its normal input voltage range is 180 256 V. The back panel provides four outlets and one inlet; the front panel contains one outlet (see Table 1 on page 2 for current ratings of different models). All outlets are spaced widely enough to provide clearance for wall warts. The IT-2315 supplies completely clean and safe power without using ground lifts or compromising the integrity of safety ground wires to reduce hum. Figure 2 IT-2315 front panel Figure 3 IT-2315 rear panel 3

Background Unfortunately, international power distribution is not balanced. Current distribution standards were derived over a century ago, long before the existence of EMI-sensitive applications, when electric power was used primarily for lights and motors. The original emphasis was on convenience for the power utilities and safety for the consumer, not on noise cancellation. The resulting distribution scheme used one hot and one neutral wire for the 230 V branch circuit with the neutral tied to a third wire connected to an earth ground. The third wire carried current as a safety precaution only if there was a short circuit. This unbalanced method causes hum in audio circuits for two main reasons: The current flowing in the hot wire induces hum in other nearby wires; low-level audio signals are particularly vulnerable. Because the impedance of chassis and cable shielding to ground is not zero, ground current flows from power supply capacitors and from EMI. This resulting voltage drop adds a 50 Hz fundamental and its harmonics to the audio signal. Similar to the method by which balanced audio lines reduce hum and other types of EMI, balanced AC power lines significantly reduce system noise in sensitive audio, video, or computer installations. The AC power feeding a facility can be balanced at its source with a center-tapped isolation transformer. The two current-carrying wires are no longer hot (230 V) and neutral (0 V), but equal voltages of opposite polarity, each referenced to the safety ground connected to the center tap. Balanced power does not induce hum into nearby audio wiring because the two power conductors induce equal and opposite voltages that cancel each other. Ground currents are also virtually eliminated by the same common-mode cancellation effect. Cumbersome and expensive star-ground systems, massive bus bars, or heavy ground rods are no longer necessary. These methods yielded only mediocre results because it is impossible to reduce the ground impedance to zero. The common-mode rejection of a truly balanced, AC supply is far more effective, simpler, and cheaper. Note: Balanced, or technical, power is recognized by the IEC for critical, lownoise applications. 4

Installation Because of its weight, the IT-2315 should be mounted at the bottom of a standard 3-U rack. Although the toroidal transformer minimizes magnetic leakage, its high capacity can radiate a small magnetic field. We recommend not placing the IT-2315 adjacent to a low-level audio signal processor, such as a mic preamp, mixer, or tape recorder; a power amp may be a more suitable rack neighbor. Place the IT-2315 in a central location so its balanced power can reach all devices to achieve the maximum noise reduction. It must be connected to a power source that supplies at least 15 A. If the total power consumption for all equipment exceeds 15 A at 230 V, disconnect high-level or mechanical devices first, such as power amps, large tape machines, and power supplies. Physically isolate equipment that must use conventional power on a different circuit and route their AC cords away from all other cables. To install the IT-2315 in a rack that has rear- as well as front-mounting rails, adjustable rear-rack ears are available from Furman (model RRM-2) to more securely attach the device on both sides. Note: The balanced power produced by the IT-2315 is restricted for use with electronic equipment only and may not be used for lighting equipment. Operation Soft Start and Outlets On/Off Indicator When power is first applied to the IT-2315, the Soft Start circuit prevents excessive inrush current from reaching the IT-2315 s transformer. After about half a second, the green Outlets On LED turns on, indicating that all outlets are fully powered. Note: If power at any of the IT-2315 s outlets turns off for any reason, the Outlets On LED will be off. Circuit Breaker On/Off Switch The only control on the IT-2315 is the large blue switch on the front panel that functions as both a precision, magnetic circuit breaker and an on/off switch (Figure 4). This breaker trips (snaps to the O position) if the total current drawn through the IT-2315 exceeds 15 A. If this occurs, reduce the load by unplugging some equipment (see Installation above), then flip the switch back to the I position. The breaker also trips in response to a short circuit at the input or output and excessive current leakage to ground. 5

Current Fault System Protection Current Fault System Protection is a safety feature that uses a special circuit breaker to detect an imbalance in the current flowing in the two hot wires. The missing current is assumed to flow through the center pin on the AC outlet (ground conductor). Ground current is a hazardous condition that often indicates a partial or full short circuit. A current as small as 5 ma is sufficient to trip the main breaker and shutdown the unit. Figure 4 Current Fault System Test button and circuit breaker/power switch Before resuming operation, it is essential to troubleshoot the source of the problem. Start by powering up the IT-2315 with nothing connected. Add one piece of gear at a time until the circuit trips again. If this device must be used, do not power it from the IT-2315; isolate it on a different AC circuit than that which supplies power to the IT-2315. Contact the manufacturer of the unit for possible solutions. Test the fault protection once a month by pushing the button marked Current Fault System Test (Figure 4). This should cause the main breaker to trip and cut off power. If this does not occur, contact a local Furman service representative. Restore operation after the test by simply turning the unit on. Extreme Voltage Shutdown This LED Status Indicator monitors wiring faults, such as accidental connection to 460 V, a hazard particularly common in the entertainment industries. The IT-2315 detects voltages less than 170 V or greater than 270 V that make operation impossible. A voltage in this Extreme range removes power to the unit before damage can occur and lights the Extreme Voltage Shutdown LED (Figure 5). If the mains voltage is in the Extreme range when power is first applied, the outlets will not receive power. If the unit has been operating within the normal voltage range and the voltage rises or falls into the Extreme range, the IT-2315 will shutdown and the LED will flash. Power will not be restored until the mains voltage rises above 180 V or falls below 260 V, which prevents on/off oscillation under marginal conditions. 6

LED Voltmeter The AC voltmeter continuously measures input voltages in four-volt steps and displays the result on a three-color, 20-LED bargraph (Figure 5). The voltmeter reads the input voltage before the circuit breaker-on/off switch so its LEDs stay on while the IT-2315 is plugged in, even when the power switch is off; this allows the voltage to be checked before powering up equipment. The LEDs are designed for continuous use and consume very little power. The normal voltage range is indicated by green LEDs, moderately high and low voltages by yellow, and high and low voltages by red (see Table 2). Figure 5 Extreme Voltage Shutdown and Outlets On LEDs and voltmeter Three special flashing patterns indicate abnormal voltage status conditions: 1. Marginal Low: The single LED flashing beneath the number 180 indicates an input voltage below 180 V. The outlets remain powered unless the input voltage falls below 170 V. 2. Marginal High: All LEDs flashing indicates an input voltage in the range 257 265 V. The outlets remain powered unless the input voltage exceeds 265 V. 3. Extreme Voltage Shutdown: If none of the voltmeter LEDs are lit and the Extreme Voltage Shutdown LED indicator is flashing, the IT-2315 has removed power from the outlets due to an input voltage below 170 V or above 270 V. The voltmeter is accurate to ±4 V under normal conditions and ±5 V in extreme cold or heat. Table 2 summarizes the IT-2315 s outlet status and the voltmeter s display for all possible voltage ranges. 7

Table 2 AC Voltmeter behavior and outlet status AC Mains Voltage Range (V) Voltage Status Voltmeter Reading Outlet Status < 165 Extreme Shutdown No meter display Extreme Voltage LED flashes Off 166 179 Marginal Low LED below the 180 V mark flashes On 180 211 Low Low red On 212 219 Moderate Low Low yellow On 220 240 Normal Green On 241 248 Moderate High High yellow On 249 256 High High red On 257 265 Marginal High All LEDs flash red On > 265 Extreme Shutdown No meter display Extreme Voltage LED flashes Off Note: The voltage reading is for advisory purposes only. The IT-2315 does not compensate for high or low line voltage. If you frequently relocate your rack, derive power from generators, use long extension cords, travel internationally, or are at risk of brownouts, you may benefit from one of Furman s AC Line Voltage Regulators. Contact Furman for more information. 8

Output Current (1Ø AC, 50 Hz) IT-2315 Specifications IT-2315S IT-2315, IT-2315B (I, F) IT-2315U IT-2315A 10 A (2300 W at 230/115 VAC) 15 A (3450 W at 230/115 VAC) 13 A (2990 W at 230/115 VAC) 15 A (3600 W at 240/120 VAC) Voltage Ranges Normal High Low Marginal (flashes alert) Extreme (shuts down IT-2315) 220 240 V 241 256 V 180 219 V 166 179 V or 257 270 V below 170 V or above 270 V Inlets IT-2315, IT-2315A (B, I, F) IT-2315U Detachable heavy duty power cord with 15 A three-prong plug to IEC-320 C-19 connector Detachable heavy duty power cord with 13 A three-prong plug to IEC-320 C-19 connector IT-2315S Outlets (Current Fault System Protected) Detachable heavy duty power cord with 10 A three-prong plug to IEC-320 C-13 connector IT-2315, (B, I, F) IT-2315U IT-2315S (A) 4 rear, 1 front, each rated at 15 A 4 rear, 1 front, each rated at 13 A 4 rear, 1 front, each rated at 10 A Input-to-Output Isolation Breakdown Voltage Capacitance 1500 V minimum 300 pf maximum Noise Attenuation Transverse Mode Common Mode > 60 db at 1 200 MHz > 80 db at DC 1 MHz 9

IT-2315 Specifications Mechanical Dimensions Weight Construction General Turns Ratio Transformer Regulation Spike Protection Modes Spike Clamping Voltage Spike Response Time Maximum Spike Energy Maximum Surge Current Power Consumption Safety Information 88 mm H x 475 mm W x 425 mm D 79 lb (35 kg) Steel chassis, powder coated; glass epoxy printed circuit boards 1:1; windings separated with Faraday shield 3% at full load Line to neutral, neutral to ground, line to ground TVSS rating of 650 V peak L-N, 400 V peak L-G, N-G 1 nanosecond 80 J per mode; 240 J total 6500 A (8 x 20 ms pulse) 8.5 W for display and control circuits independent of load CE and C-tic listed 10