Water Hygiene Chlorination Water Treatment Legionella Control

Similar documents
[[ ;/LON/P&M/896/8/09 Date: Notice inviting quotation for Repairing heating system

Control of legionella bacteria in water systems

CONTROL OF LEGIONELLA AUDIT PROFORMA

Ultra Violet Disinfection

Water System Disinfection

PRIVATE WATER SUPPLY - WATER SAFETY MAINTENANCE PLAN

What To Do When Your Well is Flooded. Common Sense Steps To Take If Your Well Is Covered by Flood Water

Domestic Chemical Water Treatment Manufacturers Association

Legionnaires disease: Technical guidance Part 3: The control of legionella bacteria in other risk systems

Repair and Disinfection of Water Mains Water Protection Program fact sheet

A guide for employers

STANDARD OPERATING PROCEDURES FOR ALL WATERMAIN DISTRIBUTION REPAIR & INSTALLATION

Complete Plumbing. Drainage Solutions Ltd. All aspects of Plumbing & Drainage work undertaken A PARTNER YOU CAN DEPEND ON.

MAGB HEALTH, SAFETY AND ENVIRONMENT GROUP POLLUTION INCIDENT RESPONSE PLAN

DISTRIBUTION, OPERATION and MAINTENANCE STRATEGY ASSET MANAGEMENT WORK PROCEDURE EMERGENCY (TEMPORARY) TREATED WATER SUPPLIES

Water Quality Contingency Planning Standard EPB 540B

Environmental Management System Procedures

save water, save money, save the environment Monsoon domestic rainwater harvesting systems

guidance notes Form C

A Guide to Trouble-Free Cooling Towers

GUIDE TO LCA STANDARDS FOR SERVICE DELIVERY

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

December 2003 EPB 241B. Some sections are completed, some are partially complete and some are left blank.

Guidance Note on Flushing

CIBSE Guide M: Maintenance engineering and management Statutory compliance legislation and guidance

Protecting your private water supplies. The possible causes of contamination and their remediation to prevent this risk.

Legionnaires disease. Part 2: The control of legionella bacteria in hot and cold water systems

it has to be Hindmarsh for Service Excellence

Making sure your private water supply is safe Rainwater

5 Precautions during construction and repairs

Managing the Risk of Legionnaires Disease in Vehicle Wash Systems

FAQ and Device/Usage Chart. What Is a Cross-Connection? What Is Backflow Prevention? What Is Backflow?

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

ANNEX 2 Emergency / Pollution Incident Response Plan

WATER HYGIENE, AIR CONDITIONING & LEGIONELLA POLICY

SECTION DISINFECTION OF PIPE AND WATER STORAGE FACILITIES

Private Water Supplies Sampling Manual. A Field Guide

Hot water supply, distribution and use

Water Networks Technician Unit WNTC07 - Network Performance Monitoring

B-1 Buildings & Service Maintenance

Fact sheet 6: for farmers

Specifications For Rehabilitation Hudson #1A Hudson #2 Foster Island Well #41

Presented By: Fred J. Sánchez Water Quality Operations Supervisor

Application for a water connection to a commercial or mixed use development

Utilities and existing services

Water Quality Engineering. Asset management tailored to your needs.

Fact sheet 6: for farmers

Indiana Department of Environmental Management. Well Disinfection

Safe Method: Gas Safety in Catering Establishments

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

An Introduction: << Enter Text Here

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Domestic heating Fuel storage tanks

4.3 Cisterns and Rain Barrels

Supporting Guidance (WAT-SG-41)

Boiler Preparation, Start-Up and Shutdown

DISTRIBUTION, OPERATION and MAINTENANCE STRATEGY ASSET MANAGEMENT WORK PROCEDURE SECONDARY DISINFECTION DESIGN AND INSTALLATION

8 Chemicals from water treatment and distribution

HEALTH AND SAFETY IN THE FOOD INDUSTRY DETECTING HARMFUL MICROORGANISMS HEALTH AND SAFETY PRECAUTIONS (EXAMPLES FROM CONQUEST FOODS)

EASTERN IRRIGATION SCHEME, VICTORIA: OPERATION OF AN ULTRA-FILTRATION PLANT FOR A CLASS A RECYCLED WATER SCHEME. David Aitken. Earth Tech Engineering

NFPA 25 FAQs. 1. When inspecting an old system (60 years or older), when/where does NFPA 25 require a system to be upgraded to present standards?

Procedures for Cutting and Handling of Asbestos Cement Pipe. City of Richmond Public Works Operations

Reference Guide for Obtaining Permits and Utility Services For New Construction

UPPER MOHAWK VALLEY REGIONAL WATER BOARD SERVICE AREA. City of Utica

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Development enquiry request

REPLACEMENT AIR CONDITIONING UNITS FOR BRITISH EMBASSY RESIDENCE

GRAHAM ENVIRONMENTAL SERVICES

SECTION IV - TESTS AND INSPECTIONS PART 1 - GENERAL Testing - General

No. Name of Legislation Applicable Issues and Requirements Demonstration of Compliance 1. Health and Safety at Work Act 1974

Flood Checklist ACTION TO BE TAKEN BEFORE THE FLOOD SEASON

DISTRIBUTION, OPERATION and MAINTENANCE STRATEGY ASSET MANAGEMENT WORK INSTRUCTION HYDRANT OPERATION

t w rentokil-hygiene.co.uk For more information, or a full view of our services please contact us.

Standard Operating Procedures for Water Line Response and Repair. 2/12/2014 Illinois State University Environmental Health and Safety

I. Introduction. 10 minutes

The Importance of Safe Isolation of Plant and Equipment

AWWA Small Systems Pipe Repair Checklist, as published in July 2008 Opflow Question of the Month

Cross-Connection Control. Protecting the potable water supply from contamination.

FINAL EVENT LIFE+ BIOMOMI BIO-MONITORING AND AUTOMATIC MICROBIOLOGICAL CONTAMINATION CONTROL SYSTEM OF INDUSTRIAL HYDRAULIC CIRCUITS

Facilities Maintenance Standards rev

LEGIONELLA MANAGEMENT AND CONTROL POLICY. Documentation control

COOLING WATER MANAGEMENT

DRAFT July, 2006 Page 1 of 18

Installation, Maintenance, & Repair Series 4000B/LF4000B

Oil and Coolant Circulating Heating System. Model - OCSM

How To Design A Gas Dryer

oil care Looking after your heating oil in the south east

COMMERCIAL REPORT / STOCK CONDITION SURVEY. Sydenham Hill Estate Sydenham Hill London SE 23

Roles and Responsibilities of Plant Commissioning, Hydrocarbon Introduction and Acceptance Test Run

Water Coolers and Dispensing Machines:

Risk Engineering Guideline

Continuous flow direct water heating for potable hot water

The Village of Malta

Asbestos Management Consultants COMPANY PROFILE Tersus Consultancy Limited

British Standard Underground Hydrant Range

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold

water regulation facts The Water Supply Regulations The Water Supply (Water Fittings) Regulations 1999 What are they, and how do they affect you?

STANDARD PLUMBING AND DRAINAGE REGULATION 2003

Transcription:

www.whs-ltd.com Water Hygiene Chlorination Water Treatment Legionella Control

WATER MAINS DISINFECTION Chlorination Procedure A chlorination has recently been carried out on your mains water supply pipe. This is the process of introducing water containing a known amount of free available chlorine into the pipe and allowing it to stand for a known period of time in order to kill potentially harmful micro-organisms such as bacteria. The normal chlorination procedure involves the introduction of at least 50 ppm of free chlorine and allowing it to stand for at least 1 hour. This is the standard set out by your Water Authority and is the method laid out in the British Standards, BS8558:2011. The chlorine within the pipe is regularly tested throughout the standing time to ensure that the chlorine levels remain at or above the target strength for the whole period. Once the chlorine has stood for the allotted time the chlorine is purged from the system. Where it is necessary to neutralise any active chlorine to prevent environmental damage this is done through the use of sodium thiosulphate crystals. These react with the chlorine and render it safe. Chlorine measurements are once more taken from the system to ensure that all chlorine has been removed and that levels are identical to those present in the mains supply (chlorine is added in small amounts to the water at the treatment works). Once chlorine levels are normal the system is sampled for microbiology and it is then capped to prevent any ingress of dirt, and a chlorination certificate is completed detailing all facts and figures of the chlorination. All samples are sent away for analysis by a UKAS accredited laboratory. What Now? Your chlorination has now been carried out and you have your certificate of chlorination. This section details what to do next. The client or main contractor will require the completed chlorination certificate below. If microbiological samples have been taken then once completed these will be provided under a separate cover and should be presented with this certificate of chlorination. If in doubt check with the main contractor as to the original specifications and what steps should be taken. This certificate should be placed into the O&M manual for future reference and inspection. Microbiology results should be provided to you within 7 days and you will need these prior to being allowed to connect. Copies of the chlorination certificate and the laboratory microbiology report must be forwarded together to the Water Authority responsible for your connection. Do not send just the chlorination certificate as it is not adequate alone. Store both the microbiology report and chlorination certificate together for future reference. Please note that a chlorination certificate is generally valid for a limited time period and connections must be carried out within the time period determined by your Water Authority. Failure to do so may render the chlorination certificate unacceptable.

Water Mains Disinfection Certificate (BS 8558:2011) Site Details Site Location Example Site Name Example Site Contact Balfour Date 22/02/2014 WHS Engineer Name Joel Green EUSR Number 185160 CSCS Number 1885371 Job Details Pipe Details System Type New Mains Installation Pipe Designation New mains pipe work for drinking water supplies and fire hydrant points. Pipe Material Barrier Pipe MDPE (Protectaline) Pipe Diameter 125/32 mm Pipe Length 250/300 m Source Water Water Supply Used Hydrant Water Supply Free Cl 2 0.05 ppm Water Supply Flow Rate 250 L/min Swabbing Swabbing Performed Double Volume Flush Swab Size N/A Pipe Flush Time 60 mins Chlorination Phase Disinfectant Used Sodium Hypochlorite Location Free Cl 2 Level Start Sprinkler tank hydrant (3) 92 ppm Courtyard hydrant (2) 88 ppm Site vehicle entrance hydrant (1) 94 ppm 32 mm plant room 1 97 ppm 63 mm plant room 2 89 ppm Location Free Cl 2 Level End Courtyard hydrant (2) 82 ppm Site vehicle entrance hydrant (1) 87 ppm Sprinkler tank hydrant (3) 80 ppm 32 mm Pipe End Room 1 93 ppm 63 mm Pipe End Room 2 75 ppm Chlorine Contact Time 60 mins Post Contact Flush Time 90 mins

Post Chlorination Phase Location Free Cl 2 Level Total Cl 2 Level Turbidity Hydrant 3 0.10 ppm 0.14 ppm 0.25 NTU Hydrant 1 0.07 ppm 0.11 ppm 0.24 NTU Hydrant 2 0.09 ppm 0.14 ppm 0.28 NTU 32 mm pipe end 0.06 ppm 0.09 ppm 0.21 NTU 63 mm pipe end 0.08 ppm 0.12 ppm 0.24 NTU Site mains supply 0.06 ppm 0.09 ppm 0.19 NTU Taste Odour & Appearance Good clear appearance and clean taste with no discernible odour. Pipe Capped Yes Samples Location Sample Type Supply Water Source Hydrant (2) courtyard Site mains supply Hydrant (3) sprinkler tank 32 mm pipe end room 1 63 mm pipe end room 2 Pipe End Hydrant (1) vehicle entrance Diagram

Photographs View of pipe work run View of end cap fitted View of stop tap fitted Comments Chlorination of new mains water pipework. Both fire main and drinking water main was part of the chlorination. Chlorination included 3 hydrants at various points on site and 2 tank supplies. All services were bought to the required levels of chlorine and left to contact for 1 hour. Post hour the system as a whole was completely flushed and all chlorine was neutralised and removed. Samples from each outlet were taken for continuity of the test. All hydrants were left isolated and both tank feeds were also left isolated. Samples sent 22/02/14 Signatures Client Signature Client Name Balfour WHS Signature WHS Name Joel Green

METHOD STATEMENT Disinfection Of Mains Supplies & New Lay Mains Pipe Work Disinfection General The following disinfection procedure is designed to remove bacterial contamination from either new mains pipe work, refurbished or altered mains pipe systems or a mains supply system that has produced a high bacterial count. If systems are heavily contaminated or show presence of biofilm then additional methods may be required to remove this from pipe work internals. It is important to ensure that when chlorinating mains water systems that all precautions are taken to ensure no backflow of chlorinated water can occur and contaminate the mains supply. It is also important to ensure that people working within the area fed by the water system are informed and cannot accidently come into contact with chemically treated water. Disinfection Procedure 1. Sign into site and obtain necessary permits to work 2. Perform full risk assessment of the area around the system to be disinfected and note pipe diameter, length and produce a rough diagram of the system. 3. Before any disinfection procedure begins place warning boards in good view. Inform relevant site staff, particularly if the water supply is to be disrupted and ensure all staff fully understand the length of service loss and relevant consequences. 4. Ensure that all outlets are clearly labeled with laminated warning signs quoting CHEMICAL DISINFECTION IN PROGRESS DO NOT USE WATER. This will ensure complete safety of all people in the area during the works. 5. Before commencing work flush the incoming water at full bore for at least 10mins, this must be done before every chlorination starts with no exceptions. Whilst flushing measure flow rate in L/min and take a water sample of the incoming water to be used for the chlorination. Label as Sample 1, name of job. Note the location and type of water supply and measure and record the free chlorine level. 6. Break into incoming pipe work/or locate pipe end and attach relevant adaptors to allow fitting of a clean hoses. All hoses used must be clean, previously disinfected and free from damage. Ensure double check valves are in place to prevent backflow. 7. If swabbing is required flush the pipe work with 2 volumes of water at maximum pressure and/or pass chlorinated foam swab into the system and push down the pipe work with water. Remove chlorinated foam swab. 8. Attach hoses from incoming mains/water supply into inlet side of chlorination equipment. Test flow is present through the system. 9. Attach hose from outlet side of chlorination equipment into feed side of mains fed system. 10. Place pickup pipe of chlorination equipment into sodium hypochlorite solution in bunded container and prime.

METHOD STATEMENT 11. Ensure connections are tight and open mains stop valve. 12. Open outlets and pull chlorinated water through to all outlets, ensuring >50ppm of chorine appears at all outlets. 13. Measure free chlorine content at pipe end or nearest and furthest outlets on each leg of pipe work with digital photometer to gain an accurate reading of free chlorine level and note results. 14. Once adequate free chlorine levels have been achieved at all outlets turn off all valves to further protect against backflow. 15. Allow the chlorine solution to stand within the pipe work for at least 1 hour or overnight as required by the Water Authority. 16. Turn back on all valves and turn off chlorination equipment. 17. Open mains stop tap/water supply tap. 18. Check chlorine levels at outlets to ensure they have remained >35 ppm and record results. If levels have dropped below 35 ppm then return to section 8 and re-start chlorination procedure. 19. If chlorine levels are >35 ppm then begin to draw water through the system to remove chlorinated water. If chlorinated water is not entering a specific foul drain or is of high volume (>500 L) then de-chlorination of the water must be undertaken. Sodium thiosulphate should be dosed into the outgoing water to fully neutralise the chlorine. Regular checks should be made to ensure all chlorine has been neutralised. 20. Continue to flush outlets until all outlets are showing identical chlorine levels to that of the incoming mains water. 21. Take required number of water samples and sample water for free chlorine, total chlorine and turbidity as standard. If required perform further chemistry samples and note all results. 22. Take water sample from the furthest outlet and label as Sample 2, name of job and outlet and take any further samples required by the client. Check water for odour, taste and appearance and note results. 23. Shut off mains stop tap/water supply and disconnect chlorination equipment. Take care to minimise loss of water from the system. 24. Reconnect mains system pipe work originally broken and turn on mains stop tap to check for leaks or cap off pipe ends with disinfected end caps. 25. Remove lock offs and signs, sign off certificate, inform site staff and sign off any work permits. Remove all debris and tools from the site prior to signing out. Note!! Ensure that all outlets return initial chlorine levels of at least 50 ppm free chlorine and that this remains higher than 35 ppm of chlorine after 1 hour. Failure to do so means failure to comply with BS8558:2011.

METHOD STATEMENT HEALTH & SAFETY DISINFECTION CHEMICAL HANDLING SITE SPECIFIC AS REQUIRED

ABOUT WATER HYGIENE SOLUTIONS LTD Water Hygiene Solutions Ltd is a specialist technical water hygiene company providing services including cleaning and chlorination work, water hygiene consultancy, water treatment chemicals and equipment. We have an excellent reputation nationwide both for the quality of work we undertake and the expertise and experience of our staff. Our can do attitude ensures that our clients obtain the work they require when they require it, particularly important when deadlines are looming. With a commitment to staff development and with significant health and safety budget you can be assured of a quality service every time. OUR SERVICES INCLUDE Water Tank Cleaning - Regardless of the type of water system it is important that water hygiene is maintained. Water storage tanks especially require regular cleaning to remove debris and bacteria build up and maintain hygiene. Even new water tanks should be chlorinated prior to use to maintain potable water quality. Our specialist teams and equipment can provide cleaning and chlorination of all types and sizes of domestic and industrial water tanks including underground rain water harvesting tanks. Legionella Management - It is vital to ensure that systems do not pose a risk of Legionnaires Disease and operate within the HSE guidelines. By carrying out bespoke water hygiene risk assessments we are able to determine the risks and provide advice on how to reduce these. It also allows us to design a Legionella control program based on current legislation. Our trained hygiene engineers can provide testing and monitoring of your site to ensure Legionella risk is managed at all times. A site specific log book for records ensures legislative compliance. Chlorine Dioxide Water Treatment Chlorine dioxide is an ideal water treatment option to reduce bacteria numbers and maintain water hygiene. It has applications both in potable water supplies for the control of Legionella and general water hygiene and also in process systems such as food manufacturing where bacterial control is important. We provide safe generation and dosage of chlorine dioxide in all applications with chemical supply and routine service. Boiler Water Treatment - Correct steam boiler management is essential as the lack of, or failure, of a water treatment regime will rapidly lead to increased fuel costs and maintenance bills and will, over time, damage steam plant. Through a full analysis of your water conditions and steam process systems we offer a tailored boiler water treatment program to include pretreatment plant and chemical water conditioning. Routine analysis by our experienced water treatment engineers ensures continued efficiencies. Cooling Tower Management - The correct management of cooling towers and evaporative condensers is essential to ensure long life, efficiency and to prevent health hazards from Legionella growth. Our water treatment engineers use in depth water analysis to develop bespoke chemical treatment programs. Service contracts provide routine analysis, monitoring and cleaning to ensure that your cooling tower remains efficient and safe and you remain compliant with HSE guidance.

METHOD STATEMENT Registered office: London office: Warehouse: Water Hygiene Solutions Ltd 16 Church Lane, Mirfield West Yorkshire WF14 9HU T: 0845 387 3037 F: 0845 387 3047 Water Hygiene Solutions Ltd International House 221 Bow Road London E3 2SJ T: 0203 390 3037 F: 0845 387 3047 E: info@whs-ltd.com www.whs-ltd.com Water Hygiene Solutions Ltd Unit 2A - Longwood Road Corringham Road Ind Est Gainsborough DN21 1QB T: 0845 387 3037 F: 0845 387 3047