EazyVolt & Voltage Tester Instruction Manual

Similar documents
Manual Ranging MultiMeter

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

AutoRanging Digital MultiMeter

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Model UT33A: OPERATING MANUAL Table of Contents (1)

Model T100, T120, T140, VDE

User Guide. 4 wire Earth Resistance Tester Model GRT300

UT202A Operating Manual. Contents

Model UT201/202: OPERATING MANUAL. Table of Contents

User's Guide. True RMS Industrial Multimeter

User Guide. Model Insulation Tester / Megohmmeter

HVAC Clamp Meter. Users Manual

10 Multimeter. Users Manual

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

i410/i1010 AC/DC Current Clamp

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Instructions A Amp AC/DC Current Probe

RM4TG20 three-phase network control relay RM4-T - range V

7 FUNCTION DIGITAL MULTIMETER

Modular I/O System Analog and Digital Interface Modules

User s Manual Before using the inverter, you need to read and save the safety instructions.

How To Use A Cdm250 Digital Multimeter

Model 1756 Test Lead Kit

Quick Connect. quick - simple - efficient.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Seven function digital multimeter

ADM1TE 5/30A DIN rail single phase two wire energy meter

Ground Resistance Clamp On Tester

INSTRUCTION MANUAL IPM Phase Power Analyser EN FR IT DE ES

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

12 Volt 30 Amp Digital Solar Charge Controller

SURGE PROTECTIVE DEVICES

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Model UT58A/B/C: OPERATING MANUAL

Owner s Manual & Safety Instructions

Handheld portable appliance testers

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

323/324/325. Calibration Manual. Clamp Meter

Safety technique. Emergency stop module BO 5988 safemaster

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Preset Counter signo 721

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Ground Resistance Clamp-On Tester

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Table of Contents. Page

Thermistor Thermometer MODEL NO

Thermocouple Thermometer Models

DLP-PU/E Instruction Manual

TIG INVERTER INSTRUCTION MANUAL

Operating Manual Remote Cost Control Monitor

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Emergency lighting units EM powerled

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Digital MULTIFUNCTION & INSULATION CONTINUITY-VOLTAGE TESTER

12-Volt 10-Amp Regulated Power Supply

SPST-NO SPDT DPST-NO DPDT

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

5SV Residual Current Protective Devices

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

Microwave Meter. Instruction Manual

U-shaped Micro Photoelectric Sensor

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Owner s Manual & Safety Instructions

3M Wrist Strap and Footwear Tester 740. User s Guide

Thermal-Magnetic Circuit Breaker M1-..

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Duct Humidity Transmitter

Fluke 1650B Series Multifunction Installation Testers

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

Insulation resistance

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Cross-beam scanning system to detect slim objects. 100 mm in

PowlVac Vacuum Integrity Tester

ABB i-bus KNX SA/S Switch Actuators Product Manual

BB800 Off-Grid Solar System

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Instruction Manual IDM 71/72/73 Digital Multimeter EN FR IT DE

MEGGER Insulation & Low Resistance Tester

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Multi-Function Ground

SX460. Generator Automatic Voltage Regulator Operation Manual

Transcription:

EazyVolt & Voltage Tester Instruction Manual EV EV

TABLE OF CONTENTS Page 1. Safety 2 2. Symbols and Features 3 3. AC/DC V Measurements 4 4. Continuity / Diode Test 5 5. Resistance Measurements 6 6. Single-Pole Phase Tests 6 7. Phase Rotation Test 7 8. RCD Voltage Test 9 9. Illumination 10 10. Battery Replacement 11 11. 4mm Tips Replacement 11 12. Cleaning 12 13. Transport And Storage 12 14. Maintenance 12 15. Specification 13 16. Warranty 15 1

1. Safety Safety Information To ensure safe operation and service of the Tester, follow these instructions. Failure to observe warnings can result in severe injury or death. - Avoid working alone so assistance can be rendered. If the operators safety cannot be guaranteed, the Tester must be removed from service and protected against use. - Prior to usage ensure perfect instrument function (e.g. on known voltage source) before and after the test. - Do not connect the instrument to voltages higher than 690V. - The safety can no longer be insured if the Tester : shows obvious damage does not carry out the desired measurements has been stored for too long under unfavorable conditions has been subjected to mechanical stress (i.e. during transport). - All relevant statutory safety regulations must be adhered to when using this instrument. - The Tester may no longer be used if one or several functions fail or if no functionality is indicated or the Tester looks damaged. - When using this Tester, only the handles of the probes may be touched do not touch the probe tips (metal part). - Do not use the Tester if the Tester is not operating properly or if it is wet. - Use the Tester only as specified in the Instruction card including environmental conditions and the usage in dry environments must be followed or the protection by the Tester might be impaired. - Use extreme caution when working around bare conductors or bus bar. Contact with the conductor could result in an electric shock. - Use caution with voltages above 50V AC rms or 110V DC. These voltages pose a shock hazard. 2

2. Symbols and Features Symbols as marked on the Tester and Instruction manual Risk of electric shock See instruction manual + or - + DC or DC measurement Equipment protected by double or reinforced insulation Battery Earth AC measurement Conforms to EU directives High Voltage Detection List of features - AC Voltage - DC Voltage - Continuity - Resistance (only on EazyVolt II) - Single pole phase test - Phase rotation of a three-phase mains - Probe tip torch - Drop proof 1 meter - IP 64 Protection - Auto Power On/Off - Selectable probe tips 2/4 mm. 3

3. AC/DC V Measurements AC V DC V Reverse polarity with sound If the tester is used in a noisy background, you need to ensure that the soundlevel of the tester is perceptible here. 4

4. Continuity / Diode Test Continuity / The Continuity / test is only possible when batteries are installed and in good condition. 5

5. Resistance Measurements Only on EV II The Resistance test is only possible when batteries are installed and in good condition. 6. Single-Pole Phase Test Single-Pole Phase Firmly 6

The single-pole phase test is only possible when batteries are installed and in good condition. The single-pole phase test is not always appropriate for testing whether a circuit is not live. For this purpose, the bipolar test is required. To determine external conductors during phase tests the display function may be impaired (e.g. for insulating body protection or insulating sites). Firmly grasp the insulated grips of the Tester probe L2 it is better for increase the sensitivity of single-pole phase test. 7. Phase Rotation Test Rotary phase of a three-phase mains Right rotary field Firmly 7

Left rotary field Firmly Testing of phase-sequence direction is possible from 100V AC voltage (phase to phase) provided the neutral is earthed. On making contact with both test electrodes (probe tips) to two phases of the three-phase power supply which are connected in clock-wise rotation, a symbol appears in the LCD Display. If the rotation is anticlockwise, then a symbol is displayed. In this case both phases of the unit should be switched around. Note : Testing the phase rotation always requires a negative phase rotation test! To ensure a connect test, it is better to test on a known source. 8

Attention : Please ensure that the test electrodes (probe tips) make good contact with two phases of a three-phase mains while testing the phase rotation. For absolute determination of a clock-wise phase rotation it is necessary to make a negative phase rotation test after changing the phases. The indication or can be affected by unfavorable light conditions, by protective clothing or in insulated locations. Firmly grasp the insulated grip of the Tester probe L2, it is better for the sensitivity of the phase rotation test. 8. RCD Voltage Test Voltage Test with RCD Trip Test During voltage tests in systems equipped with RCD circuit breakers, a RCD switch can be tripped at a nominal residual current of 10mA or 30mA by measuring the voltage between L and PE. These Testers EV/ EV are equipped with an internal load enabling the tripping of an RCD protection device of 10mA or 30mA. 9

To avoid RCD tripping, a test has to be carried out between L and N during approx. 5sec. Immediately afterwards, voltage testing between L and PE can be carried out without RCD tripping. 9. Illumination Probe tip torch 10

10. Battery Replacement If no signal sound is audible (EV)when short circuiting the test probes, if the symbol is displayed (EV) - Completely disconnect EV/ EV from the measurement circuit. - Unscrew the screw by a cross screw driver, then open the battery cover. - Remove discharged batteries. - Replace by new batteries, type 1.5V IEC LR03 by respecting correct polarity. - Close the battery cover and re-screw the screw. + - 11. 4mm Tips Replacement tighten unscrew 11

12. Cleaning Prior to cleaning, remove the instruments from all measurement circuits. If the instruments are dirty after daily usage, it is advisable to clean them by using a damp cloth and a mild household detergent. Never use acid detergents or dissolvent for cleaning. After cleaning, do not use the voltage tester till it is dried completely. 13. Transport and Storage In order to avoid instrument damage, it is advised to remove batteries when not using the instrument over a longer period. The tester must be stored in dry and closed areas. In the case of an instrument being transported in extreme temperatures, a recovery time of minimum 2 hours is required prior to instrument operation. 14. Maintenance Unauthorized persons shall not disassemble the tester and the supplementary equipment. When using tester EV/ EV testers in compliance with the instruction manual, no particular maintenance is required. If functional errors occur during normal operating, our service department will check your instrument without delay. 12

15. Specification Nieaf Instruments EV I EV II Voltage range LED/Bargraph resolution LCD voltage range LCD resolution Accuracy Voltage detection Acoustic signal sound Polarity detection Range detection 6.690V AC/DC 6,12,24,36,50,120, 230,400, 690V 10V 690V AC/DC 1V Automatic (3%rdg+2d) (AC Voltage) Yes ( DC Voltage) Yes Full range Automatic Response time <0.1s <0.1s/BAR <2s/RDG Frequency range Automatic load (RCD) Peak current Operation time Recovery Time Auto Power On DC, 45 65Hz Yes Is <0.2A / Is(5s) <3.5mA ED (DT)=30s. 10 min. <12 VAC / DC Single-pole Phase Test Voltage range Frequency range 100 690V AC 45 65Hz Resistance Test Resistance Range Accuracy Test Current 0 2K (3%rdg + 10d) < 0.5mA 13

Nieaf Instruments EV I EV II Continuity Test Threshold < 200K Test current < 20µA Overvoltage protection 690V AC/DC Rotary Field Indication Voltage range (LEDs) 100 690V Frequency range Measurement principle Power supply Power consumption Temperature Humidity Height above sea level Overvoltage class 50 60Hz Double-pole and firmly hold the grip (L2) 2 x 1.5V Micro IEC LR03 Max. 30mA / approx. 250m -10ºC 55ºC Max. 85% relative humidity Up to 2000m CAT III / 1000V CAT IV / 600V Pollution Degree 2 Type of protection IP64 / IP65 pending CE EN61326 : EN55011 : Safety EN61010-1 : 2001 EN61010-031 : 2002 EN61243-3 : 1998 EN61243-3/CI : 2000 EN60529 : 1992/AI2000 GS38 Functionality Certification Weight Dimensions EN61243-3 : 1998 EN61557-7 : 1997 EN61557-10 : 2001 EN 61557-1 : 1997 KEMA / VDE CSA / UL pending 230g (EVI), 240g (EVII), (incl. Batteries) 245x61x36mm 14

16. Warranty Nieaf Instruments are subject to strict quality control. However, should the instrument function improperly during normal use, you are protected by our 6 month warranty. We will repair or replace free of charge any defects in workmanship material, provided the instrument is returned unopened and unhampered with. Damage due to dropping or incorrect handling is not covered by the warranty. If the instrument shows failure following expiry of warranty, our service department can offer you a quick and economical repair. 15