MiniTec TM Series Manual Ranging Mini MultiMeter Model MN35 USER MANUAL

Similar documents
Manual Ranging MultiMeter

AutoRanging Digital MultiMeter

User's Guide. True RMS Industrial Multimeter

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

User Guide. Model Insulation Tester / Megohmmeter

Model UT33A: OPERATING MANUAL Table of Contents (1)

Hygro-Thermometer + InfraRed Thermometer Model RH101

UT202A Operating Manual. Contents

Model UT201/202: OPERATING MANUAL. Table of Contents

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

10 Multimeter. Users Manual

User Guide. 4 wire Earth Resistance Tester Model GRT300

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Ground Resistance Clamp On Tester

7 FUNCTION DIGITAL MULTIMETER

How To Use A Cdm250 Digital Multimeter

Model UT58A/B/C: OPERATING MANUAL

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

Integrating Sound Level Meter and Datalogger

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Table of Contents. Page

Owner s Manual & Safety Instructions

4-Channel Thermometer / Datalogger

HVAC Clamp Meter. Users Manual

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Seven function digital multimeter

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Intelligent Digital Multimeters

DIGITAL MULTIMETER OPERATION MANUAL ITEM DIGITAL MULTIMETER CONTENTS

Model UT60A: OPERATING MANUAL. Table of Contents. Page

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

RS DIGITAL THERMOMETER

User Guide. Temperature and Humidity Datalogger. Model 42280

USER GUIDE. LED Light Meter. Model LT45

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

INTRODUCTION SAFETY PRECAUTIONS/

Owner s Manual & Safety Instructions

User's Guide. Digital Sound Level Meter. Model

Model UT71A/B OPERATING MANUAL

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

User's Guide. Pinless Moisture Meter. Model MO257

Thermistor Thermometer MODEL NO

AVO410. Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter

i410/i1010 AC/DC Current Clamp

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Ground Resistance Clamp-On Tester

323/324/325. Calibration Manual. Clamp Meter

Model UT713 OPERATING MANUAL

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Instructions A Amp AC/DC Current Probe

Model 77 Series IV Digital Multimeter

Microwave Meter. Instruction Manual

Model 1756 Test Lead Kit

Mini Power Bank and Charger

Essential Electrical Concepts

ECO SENSORS, INC. OZONE SENSOR AND MONITOR

User s Manual Before using the inverter, you need to read and save the safety instructions.

Portavision-50 AM/FM/TV1/TV2 Portable Radio ( ) Features Faxback Doc. #

What is a multimeter?

T+ and T+ PRO Electrical Tester

User's Guide Integrating Sound Level Datalogger Model

AM/FM Aircraft Radio ( ) Features Faxback Doc. # 17253

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Table of Contents. Page No.

How To Use A Power Supply Unit (Upu)

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Mini InfraRed Thermometer with Laser Pointer

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

1587/1577. Insulation Multimeters. Users Manual

Install Guide CT101. Caution. Caution

ExStik TM ph Waterproof Meters

BLOOD COLLECTION MIXER

Multimeter with Temperature

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Table of Contents. Title

User s Manual AURORA 1.2K/2.2K

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter

High Temperature InfraRed Thermometer with Laser Pointer

ABCs of DMMs Multimeter features and functions explained Application Note

Users Manual. ProcessMeter

DLP-PU/E Instruction Manual

Operating Instructions Air Conditioner

12-Volt 10-Amp Regulated Power Supply

HOW TO USE MULTIMETER. COMPILE BY: Dzulautotech

Renewable Energy Monitor User Manual And Software Reference Guide. (979)

AM/FM Portable Radio

1. SAFETY INFORMATION

EzFlex Combustible Gas Leak Detector Model EZ40

Instruction Manual IDM 71/72/73 Digital Multimeter EN FR IT DE

AM/FM Stereo Portable Radio ( ) Features Faxback Doc. # 19744

Portable Multiband Radio ( A) Features Faxback Doc. # 56400

±15 V Current-Limited Power Supply

MODEL 2202IQ (1991-MSRP $549.00)

MCR1900 Media Converter 19-Slot Chassis

User Manual for CH-PFC76810

900 MHz Lightweight Wireless Stereo Headphones

OPERATING INSTRUCTIONS

Transcription:

MiniTec TM Series Manual Ranging Mini MultiMeter Model MN35 USER MANUAL

Introduction Congratulations on your purchase of Extech s MN35 Manual Ranging Multimeter. This meter measures AC/DC Voltage, DC Current, Resistance, Temperature, Battery Test, Diode Test and Continuity. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version of this User Guide, Product Updates, and Customer Support. Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation Safety Precautions 1. Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual before operating the meter. 2. Make sure any covers or battery doors are properly closed and ured. 3. Always remove the test leads before replacing the battery or fuses. 4. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair any damage before use. 5. Do not exceed the maximum rated input limits. 6. Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard. 7. Always discharge capacitors and remove power from the device under test before performing Diode, Resistance or Continuity tests. 8. Remove the battery from the meter if the meter is to be stored for long periods. 9. To avoid electric shock, do not measure AC current of any kind Input Limits Function Maximum Input VDC, VAC 600V DC/AC Resistance, Diode, Continuity 500V DC/AC ma DC 250mA DC 10A DC 10A DC (15sec. max every 15 min.) 2

Meter Description 1. LCD Display 2. Hold button 3. Function switch 4. COM jack 5. 10A jack 6. Positive jack Note: Tilt stand and battery access is on the rear of unit. Operating Instructions Note: If H and a blank screen appear when the meter is turned on the HOLD feature is active. Press the HOLD button to exit the HOLD mode. AC or DC Voltage Measurements plug into the positive V jack. 2. Turn the rotary switch to the highest VAC or VDC position. 3. Touch the test probes to the circuit under test and read the voltage on the display. 4. Reset the function switch to successively lower positions to obtain a higher resolution reading. If the polarity is reversed (DC voltage only), the display will show ( ) minus before the value. DC Current Measurements CAUTION: Do not make current measurements on the 10A scale for longer than 15 seconds followed by a 15 minute cool down period. Exceeding 15 seconds may cause damage to the meter and/or the test leads. 1. Insert the black test lead banana plug into the negative COM jack. 2. For current measurements up to 200mA DC, set the function switch to the 200mA DC position and insert the red test lead banana plug into the V/ /ma jack. 3. For current measurements up to 10A DC, set the function switch to the 10A DC range and insert the red test lead banana plug into the 10A jack. 4. Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current. 5. Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to the positive side of the circuit. 6. Apply power to the circuit. 7. Read the current in the display. 3

Resistance Measurements plug into the positive V/ /ma jack. 2. Set the function switch to the highest position. 3. Touch the test probe tips across the circuit or part under test. It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading. 4. Read the resistance in the display and then set the function switch to the lowest position that is greater than the actual or any anticipated resistance. Temperature Measurements WARNING: To avoid electric shock, disconnect test leads from any source of voltage before making a temperature measurement. Be sure that the thermocouple has been removed before changing to any other measurement function. 1. Insert the type K thermocouple probe into the V/ /ma and COM jacks. 2. Turn the rotary switch to the o F or o C position. 3. Read the temperature on the display. Continuity Measurements plug into the positive V/ /ma jack. Observe polarity. 2. Turn the rotary switch to the ))) position. 3. Touch the test probes to the circuit or device under test. If the resistance is less than approximately 40 the buzzer will sound. Diode Measurements plug into the positive V/ /ma jack. 2. Turn the rotary switch to the ))) position. 3. Touch the test probes to the diode under test. Forward voltage will indicate 0.4V to 0.7V. Reverse voltage will indicate 1.. Shorted devices will indicate near 0mV and an open device will indicate 1. in both polarities. Battery Test plug into the positive V jack. 2. Turn the rotary switch to the 1.5V or 9V BAT position. 3. Connect the red test lead to the positive side of the 1.5V or 9V battery and the black test lead to the negative side of the 1.5V or 9V battery. 4. Read the voltage in the display. Good Weak Bad 9V battery: >8.2V 7.2 to 8.2V <7.2V 1.5V battery: >1.35V 1.22 to 1.35V <1.22V Data Hold Press the Hold button to freeze the reading in the display. H will appear in the LCD. Press the key again to release the display. 4

Maintenance WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the battery/fuse cover. WARNING: To avoid electric shock, do not operate your meter until the battery/fuse cover is in place and fastened securely. This Multimeter is designed to provide years of dependable service, if the following care instructions are performed. 1. Keep the meter dry. 2. Use and store the meter in mild ambient conditions. Temperature extremes can shorten the life of the electronic parts and distort or melt plastic parts. 3. Handle the meter gently. Dropping it can damage the electronic parts or the case. 4. Keep the meter clean. Wipe the case occasionally with a damp cloth. DO NOT use chemicals, cleaning solvents or detergents. 5. Use only fresh batteries of the recommended size and type. Remove old or weak batteries so they do not leak and damage the unit. 6. If the meter is to be stored for a long period of time, the batteries should be removed to prevent damage to the unit. 5

Battery Replacement WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the battery/fuse cover. 1. Disconnect the test leads from the meter. 2. Remove the rubber holster (if in place). 3. Remove the two screws securing the rear cover using a Phillips head screwdriver. 4. Lift the cover off and replace the battery observing the correct polarity. 5. Insert the new battery into the battery holder. 6. Replace the rear cover and secure with the screws. Fuse Replacement Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and electronic equipment. Other Battery Safety Reminders o Never dispose of batteries in a fire. Batteries may explode or leak. o Never mix battery types. Always install new batteries of the same type. WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing battery/fuse cover. 1. Disconnect the test leads from any circuit being measured. 2. Remove the rubber holster (if in place). 3. Remove the two screws securing the rear cover using a Phillips head screwdriver. Remove the rear cover. 4. Remove the old fuse by gently pulling up on it. 5. Install the new fuse by gently pushing it into the holder. 6. Always use a fuse of the proper size and value; 250mA/250V fast blow. 7. Replace the rear cover and secure with the screws. 6

Specifications Function Range Accuracy DC Voltage (V DC) 200.0mV 2.000V 20.00V 200.0V 600V AC Voltage (V AC) 200.0V (40 400Hz) 600V DC Current (A DC) Resistance Temp F (0.5% reading + 2 digits) (0.8% reading + 2 digits) (1.2% reading + 10 digits) 200.0mA (1.5% reading + 2 digits) 10.00A (3.0% reading + 5 digits) 200.0 (0.8% reading + 4 digits) 2.000k 20.00k 200.0k 20.00M 4 to 1400 F (0.8% reading + 2 digits) (3.0% reading + 3 digits) 4 to 59 F; (2.5% reading + 19 digits) 60 to 750 F (1.0% reading + 9 digits) 751; to 1400 F; (2.5% reading + 19 digits) 20 to 16 C; (2.5% reading + 10 digits) Temp C 20 to 750 C 17 to 400 C; (1.0% reading + 5 digits), 400 to 750 C; (2.5% reading + 10 digits) (probe accuracy not included) Accuracy Stated at 23 o C 5 o C (73 o F 10 o F) and less than 70% RH Diode Test Test current of 1mA maximum, open circuit voltage 2.8V DC typical Continuity Check Audible signal will sound if the resistance is less than approximately <40 5 Temperature sensor Requires type K thermocouple Input Impedance 10M (VDC) and 4.5M (VAC) Display 1999 count LCD Overrange 1 or 1 is displayed Polarity Automatic (no indication for positive polarity); Minus ( ) sign for negative polarity. Measurement Rate3 times per second, nominal Low Battery is displayed if battery voltage drops below operating voltage Batteries Requires one 9V battery (NEDA 1604 or equivalent) Fuses ma range; 250mA/250V fast blow 10A range, no protection Operating Temp 0 o C to 40 o C (32 o F to 104 o F) Storage Temp 20 o C to 60 o C ( 4 o F to 140 o F) 7

Relative Humidity Maximum relative humidity 80% for temperatures up to 31 C decreasing linearly to 50% relative humidity at 40 C. Operating Altitude 2000 meters (7000ft) maximum. Weight 153g (5.4 oz.) Size 138mm x 72mm x 38mm (5.43 x 2.83 x 1.5 ) Safety For indoor use and in accordance with Overvoltage Category II, Pollution Degree 2. Category II includes local level, appliance, portable equipment, etc., with transient overvoltages less than Overvoltage Category III. Symbols AC (voltage) DC (direct current or voltage) ))) Continuity and Diode test mv, V millivolt, volt (voltage) km ohm, kilohm, megohm (resistance) µa, ma, A microamp, milliamp, Amp (current) º F, º C Degrees Fahrenheit, centigrade (temperature) º HOLD Low battery Display hold. Copyright 2013 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www.extech.com 8