Photo Z. Jedrus A breakthrough in long life, energy efficient lighting Energy Advantage Long Life 25W T8 System
Optanium Ballasts from Advance and Philips Energy Advantage Long Life 25W T8 Lamps The industry s lowest energy-consuming 4-foot T8 system available. For example, two Energy Advantage Long Life 25W T8 lamps driven by a 2-lamp Optanium electronic ballast consumes only 43 total watts, as much as 27% lower than a standard 32W T8 system (which draws 58 59 watts), reflecting a consumption range of only 21.5 22 watts per lamp for one, two, three or four lamp models. The Optimized Solution Developed jointly to optimize performance, the new fluorescent T8 system comprised of Philips Lighting s Energy Advantage Long Life 25W T8 lamp featuring ALTO Lamp Technology and Advance s family of high-efficiency Optanium electronic ballasts currently represent the lowest energy-consuming 4-foot T8 system on the market. Optimized by Philips Lighting and Advance for energy efficiency on both Instant Start and Programmed Start lamp ignition, this revolutionary 25W system can help reduce energy consumption by over 40% relative to older systems involving T12 lamps and magnetic ballasts, and by 20 30% relative to systems utilizing conventional T8 lamps and electronic ballasts. Suitable for both new construction and retrofit applications, Philips and Advance s optimized system for 25W fluorescent T8 applications represents a long life, maximumefficiency, high-performing, and sustainable lighting solution for today s general office, healthcare, retail, and warehouse settings. The system represents a major breakthrough in long life, low energy-consumption lighting and provides a range of powerful features. 2
Long lamp life equates to lower maintenance costs, thereby reducing cost-of-ownership even further. Photo Z. Jedrus Optimal System Design Delivers 36,000 Hour Rated Average Lamp Life 1 Poor maintenance can result in lower light levels, dark fixtures, inconsistent lamping, poor color, and employee complaints. Using the Energy Advantage Long Life 25 Watt lamp in conjunction with the Advance High Performance Optanium Programmed start ballast extends the service cycle, which lowers labor and material cost, and avoids work interruptions. When operated on 12-hour cycles, this system delivers an industry leading rated average life 1 of 36,000 hours, 50% longer than standard T8 lamps. 1) Average life under engineering data with lamps turned off and restarted once every 12 operating hours. 3
Optimized System Warranty Only from Philips Lighting and Advance Energy Advantage Long Life 25W T8 lamps with Optanium Instant Start Electronic Ballasts Delivers long lamp life (30,000 hours rated average life 1 at 12 hours per start) 2400 approximate initial lumens 2 with 95% lumen maintenance Superior color rendering (85 CRI) 30 month lamp warranty 60 month ballast warranty 3 Energy Advantage Long Life 25W T8 lamps with Optanium Program Start Electronic Ballasts Delivers long lamp life (36,000 hours rated average life 1 at 12 hours per start) 2400 approximate initial lumens 2 with 95% lumen maintenance Superior color rendering (85 CRI) 36 month lamp warranty 60 month ballast warranty 3 Breakthrough Lamp Technology: Philips Energy Advantage Long Life 25W T8 Long lamp life (30,000 hours of rated average life 1 at 12 hours per start on Optanium Instant Start ballasts and 36,000 hours of rated average life 1 at 12 hours per start on Optanium Programmed Start ballasts) 2400 approximate initial lumens 2 with 95% lumen maintenance Superior color rendering (a CRI of 85) Low mercury (Philips ALTO lamps average 70% less mercury than the 2001 industry average for fluorescent lamps up to 60 inches, which are not TCLP 4 -compliant) 1) Average life under engineering data with lamps turned off and restarted once every 12 operating hours. 2) The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions. 3) Together the system further qualifies for Advance s exclusive PLUS 90 Protection, which adds 90 days of additional warranty protection on both the lamps and ballasts. For details, visit www.advancetransformer.com/support and click on Warranty. 4) The TCLP is the US EPA s Toxicity Characteristic Leaching Procedure. 4
Optanium Ballasts, Optimized for Instant Start Operation IntelliVolt multiple-voltage technology enables the ballasts operation at any input voltage from 120 to 277 volts, 50/60Hz Anti-striation circuitry eliminates flicker and improves visual comfort Independent lamp operation (ILO) Lamp auto-restrike capability eliminates the need to reset power mains after failed lamps are replaced 20-foot remote mounting/tandem wiring capability for maximum application flexibility UL Type CC Anti-Arc rating protects system components in the event of damaged sockets or poorly-seated lamps Standard F32T8 System vs. Energy Advantage Long Life 25W T8 System Operating on an Instant Start Ballast 3-lamp System @.10 Per KWH Standard F32 T8 Energy Advantage Long Life 25W T8 Standard Instant Start Ballast High-efficiency Optanium.87 Ballast Factor (BF) 1 Instant Start Electronic Ballast.87 Ballast Factor 1 CRI Maintained Lumens System Wattage 78 85 2800 x.87 2400 x.87 BF 1 x.95 LM x 3 = 6943 BF 1 x.95 LM x 3 = 5951 88 65 Energy Savings 23 Watts Saved Annual Energy Saved $3.32 Per Lamp 2 Energy Saved $23.11 Per Lamp 2 over Rated Average Lamp Life 3 This feature is only available on the IntelliVolt models. 1) Ballast Factor (BF): Measure of light output from lamp operated by commercial ballast, as compared to a laboratory standard reference ballast. 2) Based on 4,380 annual operating hours, 12 hours per day/7 days per week at.10 per KWH. Hours x KWH Rate x Watts Saved 1000. 3) Average life under engineering data with lamps turned off and restarted once every 12 operating hours. 5
Optanium Ballasts, Optimized for Programmed Start Operation Advance s Optanium Programmed Start electronic ballasts, together with Philips Energy Advantage Long Life 25W T8 lamps represent the industry's lowest energy-consuming Programmed Start system as well as the only one suitable for applications involving frequent on/off switching or occupancy sensors. IntelliVolt multiple-voltage technology enables the ballasts operation at any input voltage from 120 to 277 volts, 50/60Hz 20-foot remote mounting/tandem wiring capabilities UL Type CC Anti-Arc rating protects system components in the event of damaged sockets or poorly-seated lamps Semi-independent lamp operation Auto-restrike capability Standard F32T8 System vs. Energy Advantage Long Life 25W T8 System Operating on a Programmed Start Ballast 3-lamp System @.10 Per KWH Standard F32 T8 Energy Advantage Long Life 25W T8 Standard Instant Start Ballast High-efficiency Optanium Programmed.87 Ballast Factor (BF) 1 Start Electronic Ballast.88 Ballast Factor 1 CRI Maintained Lumens System Wattage 78 85 2800 x.87 2400 x.88 BF 1 x.95 LM x 3 = 6943 BF 1 x.95 LM x 3 = 6019 88 67 Energy Savings 21 Watts Saved Annual Energy Saved $2.95 Per Lamp 2 Energy Saved $24.25 Per Lamp 2 over Rated Average Lamp Life 3 This feature is only available on the IntelliVolt models. 1) Ballast Factor (BF): Measure of light output from lamp operated by commercial ballast, as compared to a laboratory standard reference ballast. 2) Based on 4,380 annual operating hours, 12 hours per day/7 days per week at.10 per KWH. Hours x KWH Rate x Watts Saved 1000. 3) Average life under engineering data with lamps turned off and restarted once every 12 operating hours. 6
Outperform T12 Systems Replacement of existing F34T12 magnetic systems with Energy Advantage Long Life 25W T8 lamps and High Efficiency Optanium Programmed Start Ballast can deliver an energy savings of up to 60 Watts per fixture, or over 40%! The Energy Advantage Long Life 25W T8 is ideal for office environments that are currently overlit with antiquated T12 lamps and need more energy efficiency without sacrificing light quality. Photo Z. Jedrus Standard F34T12 System vs. Energy Advantage Long Life 25W T8 System Operating on a Programmed Start Ballast 3-lamp System @.10 Per KWH Standard F34 T12 Energy Advantage Long Life 25W T8 Standard Instant Start Ballast High-efficiency Optanium Programmed.88 Ballast Factor (BF) 1 Start Electronic Ballast.88 Ballast Factor 1 CRI Maintained Lumens System Wattage 62 85 2650 x.88 2400 x.88 BF 1 x.87 LM x 3 = 6087 BF 1 x.95 LM x 3 = 6019 115 67 Energy Savings 48 Watts Saved Annual Energy Saved $6.57 Per Lamp 2 Energy Saved $45.00 Per Lamp 2 over Rated Average Lamp Life 3 1) Ballast Factor (BF): Measure of light output from lamp operated by commercial ballast, as compared to a laboratory standard reference ballast. 2) Based on 4,380 annual operating hours, 12 hours per day/7 days per week at.10 per KWH. Hours x KWH Rate x Watts Saved 1000. 3) Average life under engineering data with lamps turned off and restarted once every 12 operating hours. 7
Philips Lighting Company 200 Franklin Square Drive P.O. Box 6800 Somerset, NJ 08875-6800 1-800-555-0050 A Division of Philips Electronics North America Corporation Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050 A Division of Philips Electronics Ltd. Advance 10275 West Higgins Road Rosemont, IL 60018-5603 1-800-322-2086 A Division of Philips Electronics North America Corporation www.philips.com www.advancetransformer.com Printed in USA 4/05 P-5751