for air dampers and control valves of oil and gas burners

Similar documents
TX OPEN RS232/485 module

Air damper actuators

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Electric Rotary Actuator - On/Off or programmable control actuator

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Digital input modules

Duct Humidity Transmitter

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

How To Power A Schen

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

VAV compact controller KNX / PL-Link

Adjustable room thermostat for heating only or cooling only systems

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Series 6000 Torque measured metal bellow coupling

Actuators. Building Technologies HVAC Products

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

VAV compact controller KNX / PL-Link

RRV934. Multi-controller. Synco living

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

NEXUS FX04 and FX04-1 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION. FX04-1 Shown

Drayton Digistat +2RF/+3RF

HCR3.2/.. Chipcard reader HOTEL SOLUTION

How To Read A Pipe From A Sensor

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Cross-beam scanning system to detect slim objects. 100 mm in

Butterfly Valves PN 6/10/16 for flanged connection

HMI display Installation Guide

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

WE-350 Series ¼ Turn Electric Actuator

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Combi switchbox with integrated 3/2 way pilot valve

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Technical Data. Dimensions

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Mounting Instructions. Torque Transducer. A en

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

Loewe GK Installation and operating manual

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

3/2- and 2/2-way cartridge valve type BVE

Description. Dimensions. Features. precision works better

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

OZW30. Central Unit SYNERGYR

804 Ti Stand. Manual EN

industrial drive systems AC LINE Spring-applied single-disc brake A H E00 / E00

Plug-in relays Mini ISO relays

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Reaction Torque Sensor

HERZ-Thermal Actuators

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Cable Plug acc. to DIN EN , Form A

Product and functional description

Redundancy Module QUINT-DIODE/40

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

D.C. Motors. Products and specifications subject to change without notice.

GREISINGER electronic GmbH

BoWex SD, SD1 and SD2 Operating-/Assembly Instructions

MOUNTING AND OPERATING INSTRUCTIONS

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

SMS 4 / SMS 5 safety mat Product information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Electronic overload relay EF19 and EF45

Highly flexible couplings

Manual. Solar Fountain Mobile Phone Charger

Type: DILM32 10(24V50HZ) Article No.:

Explosion proof enclosures

Operating instructions

Rotary actuators Rotary wing drives Series RAK. Brochure

Unit 24: Applications of Pneumatics and Hydraulics

Inductive sensor NI10-M18-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

R.C.C.B. s two-pole LEXIC

Heating Controller. Building Technologies HVAC Products

Proportional pressure regulators VPPE

Laserlyte-Flex Alignment System

n Measuring range 0... ± 0,02 Nm to 0... ± 1000 Nm n Low linearity deviation of ± 0.05 % F.S. n Intelligent operating state indicator

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Transcription:

7 814 Actuators for air dampers and control valves of oil and gas burners SQM45... SQM48... Electromotoric actuators Torques: SQM45... up to 3 Nm SQM48... up to 20 Nm SQM48.6... up to 35 Nm Running times: 1) SQM45... 10... 120 s SQM48... 30... 120 s SQM48.6... 60... 120 s 1) Depending on the type of basic unit (LMV5...) Versions: Choice of drive shafts (refer to «Type summary») The actuators SQM45... / SQM48... and this Data Sheet are intended for use by OEMs which integrate the actuators in their products! Use The actuators of the SQM45... / SQM48... range are used to drive gas and air dampers, oil control valves and other ancillary equipment. When used in connection with burner controls or electronic fuel / air ratio control, the associated controlling elements are controlled depending on burner output. 14.04.2009 HVAC Products

Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes must be observed! Do not open, interfere with or modify the actuators! All activities (mounting, installation and service work, etc.) must be performed by qualified staff Before making any wiring changes in the connection area, completely isolate the plant from mains supply (all-polar disconnection). Ensure that the plant cannot be inadvertently switched on again and that it is indeed dead. If not observed, there is a risk of electric shock hazard Ensure protection against electric shock hazard by providing adequate protection for the actuator and for the connection terminals and by securing the housing cover Each time work has been carried out (mounting, installation, service work, etc.), check to ensure that wiring is in an orderly state Fall or shock can adversely affect the safety functions. Such units must not be put into operation, even if they do not exhibit any damage Mounting notes Ensure that the relevant national safety regulations are complied with The connection between actuator drive shaft and controlling element must be flexible but torsionally rigid couplings with free from backlash Positive connection Possible connection with drive shaft or hub: Groove with Woodruff key Drive shaft with flat edge and matching counterpiece To avoid inadmissible loads and moments by mechanical overload, appropriate actions must be taken at the mechanical coupling Example: Metal bellows clutches as compensating clutches with no mechanical play Cable and cable shielding Only the specified cable may be used (refer to Basic Documentation P7550). The cable s shielding must be connected to the printed circuit board using the tab provided. Ensure that the actuator s housing is connected to functional earth (FE) of the system. If necessary, remove isolating layers of paint from the fixing points on the burner s casing or run separate earth wires. For detailed information, refer to «Installation Instructions for the LMV5 system» (J7550.1). CAN bus AGG5.6... 7814z03e/0502 Basic unit LMV5... SQM4... FE Working range of actuator The working range is given on the type field and must be observed when mounting the actuator. To ensure the actuator is accurately located on the burner, a positioning pin of 6 mm diameter must be fitted on the mounting surface. 2/8

Mounting notes (cont d) IP54 To ensure degree of protection IP54, suitable M16 glands must be fitted in the actuator s M16 openings. The M16 glands used must feature cable strain relief. To ensure degree of protection IP54 during the actuator s entire service life, the bearing of the drive shaft must be located such that it will not be directly exposed to water or dust. Mounting example Spacer Mounting plate SQM45... Mounting plate VKF41... Secure coupling piece to drive shaft such that intermediate plastic piece has an axial play of about 0.2 to 0.5 mm ASK33.4 VKF41... Installation notes Housing cover ESD Addressing Cable length Topology To ensure protection against electric shock hazard, make certain that the AC 230 V section of the SQM4... is strictly segregated from the functional low-voltage section The holding torque is reduced when the actuator s power supply is switched off The housing cover may only be removed for short periods of time for wiring or when making the addressing. It must be made certain that dust or dirt will not get inside the actuator while such work is carried out. The actuator contains a printed circuit board with ESD-sensitive components. The top side of the board carries a cover which affords protection against direct contact. This protective cover must not be removed! The underside side of the board must not be touched. Addressing (assignment of functions) defines whether the SQM4... shall operate as a fuel actuator air damper actuator, or auxiliary actuator, and is made with the display and operating unit AZL5... and the addressing button on the actuator, which is located under the housing cover (refer to Basic Documentation P7550). The correct assignment of actuator functions can be checked with the help of flashing LEDs. For the maximum permissible cable length, refer to the Basic Documentation. Cabling must be strictly serial (no branching permitted!). 3/8

Standards and certificates Conformity to EEC directives - Electromagnetic compatibility EMC (immunity) - Low-voltage directive 2004/108/EC 2006/95/EC ISO 9001: 2000 Cert. 00739 ISO 14001: 1996 Cert. 38233 Service notes Replacement When replacing an actuator, the following points must be checked and, if necessary, corrected: Addressing (assignment of functions) Bus termination Adjustment of the curvepoints of electronic fuel / air ratio control (e.g. with the LMV5...) Disposal notes The actuator contains electrical and electronic components and must not be disposed of together with domestic waste. Local and currently valid legislation must be observed. Mechanical design Housing The housing is made of die-cast aluminium. The cover is made of impact-proof and heat-resistant plastic. Color of cover: Black Actuator Adjustment of switching points / position indication Electrical connections Geartrain Drive shaft Mounting and fixing Mounting kit ASK33.4 Stepper motor In connection with the basic unit (e.g. LMV5...): Via the display and operating unit AZL5 (refer to Basic Documentation P7550). RAST3.5 terminals (supplied together with the AGG5.720 / AGG5.721). SQM45...: Spur gears made of plastic with small backlash and permanent lubrication. SQM48...: Spur gears made of steel with small backlash and permanent lubrication. Made of black-finished steel, ready fitted to the front of the gear train (SQM48... uses a drive shaft made of hardened steel). The front of the gear train is used as the mounting surface. The actuator has 4 fixing holes and 1 elongated hole for the positioning pin. Alternatively, the actuator can be secured from the side of the controlling element with 3 self-tapping screws. For mounting of SQM45.295A9 actuator on VKF41...C butterfly valve, an ASK33.4 mounting kit is always required. The mounting kit consists of coupling with a preassembled mounting kit. 4/8

Type summary Actuators SQM4... Type reference Drive shaft 1) Running time (min.) for 90 Nominal torque (max.) Holding torque 2) (max.) Radial bearing force (max.) no. s Nm Nm N SQM45.291A9 1 10 3 3) 4) 1.5 190 SQM45.295A9 5 10 3 3) 4) 1.5 190 SQM48.497A9 7 30 20 3) 4) 20 420 SQM48.697A9 7 60 35 3) 4) 35 800 Legend 1) Refer to «Dimensions» 4) Under nominal conditions 20 C. Under extreme 2) With operating voltage applied conditions (above +50 C ambient temperature), the 3) Under nominal conditions 20 C. Under extreme conditions (below 15 C ambient temperature), the available torque is about 15 % lower torque is about 15 % lower Ordering When ordering, please give type references of actuator and accessories according to «Type summary». In addition to the actuator, the following item is to be ordered separately and is also supplied as a separate item: Shielded cable Special terminals RAST3.5 as part of the AGG5.720 / AGG5.721 kit Accessories Accessories must be ordered as separate items. Mounting kit - For mounting of SQM45.295A9 on VKF41...C butterfly valve ASK33.4 CAN bus connecting cable - Between LMV5... and SQM4... or between the SQM4... - Shielded 5-core cable - Cable length 100 m, 8 mm dia. - Power supply 2 x 1,3 mm², 1 x 0,56 mm² - Data line 2 x 0,22 mm² - Double shielding AGG5.641 CAN bus connecting cable - Shielded 5-core cable, 100 m - Refer to Basic Documentation on LMV5... (P7550) AGG5.631 Separable cable entry (single packing) Separable cable entry (packed in sets of 50) AGG5.810 AGG5.812 Specified connecting cables are mandatory! 5/8

Technical data Actuator Environment conditions Operating voltage AC 2 x 12 V via bus cable from the basic unit or via a separate transformer Safety class III to IEC730-1 Power consumption - SQM45... 9...15 VA - SQM48... 26...34 VA On time 50 %, max. 3 min. continuously Angular adjustment Max. 90 Mounting position Optional Degree of protection To EN 60529, IP54, provided adequate cable entries are used Cable entry SQM45... / SQM48...: Insertable threaded cable glands for 2 x M16 Electrical connections RAST3.5 terminals (for details, refer to the basic unit) Ferrules Matching the dia. of the stranded wire Direction of rotation Can be selected on the basic unit Torques and holding torques Refer to «Type summary» Reproducibility (typically in the show-room ± 0.2 (when used with the basic unit condition) LMV5...) Running times Refer to «Type summary» (can be selected on the basic unit) Load changes with continuous nominal load - SQM45... / SQM48.497... Typically 500,000 Typically 300,000 - SQM48.697... Weight - SQM45... - SQM48... Direction of rotation (when facing the shaft) - Standard - Reverse Approx. 1 kg Approx. 1.6 kg Counterclockwise Clockwise Storage DIN EN 60721-3-1 Climatic conditions Class 1K3 Mechanical conditions Class 1M2 Temperature range -20...+60 C Humidity <95 % r.h. Transport DIN EN 60721-3-2 Climatic conditions Class 2K2 Mechanical conditions Class 2M2 Temperature range -20...+70 C Humidity <95 % r.h. Operation Climatic conditions Mechanical conditions Temperature range Humidity DIN EN 60721-3-3 Class 3K3 Class 3M3-20...+60 C <95 % r.h. Condensation, formation of ice and ingress of water are not permitted! 6/8

Function The actuators SQM45... / SQM48... are of robust design and have a gear train with only small backlash. Control and position feedback take place via a bus system (CAN). The bus cable is also used for powering the actuators. The actuators are driven by stepper motors and can be positioned with a resolution of 0.1. The characteristics and settings (running time, direction of rotation, limit positions) of the SQM4... are determined by the controlling basic unit (e.g. LMV5...; for details, refer to the Basic Documentation P7550 of the LMV5...). The running times of the associated controlling elements are varied by the basic unit depending on the burner s control phase (e.g. startup phase: short running time; operation: long running time). Terminating resistor At the end of the serial bus cabling, a terminating resistor must be fitted. For that purpose, a jumper must be set to BUS TERMINATION on the last actuator of the bus cable, which will activate the resistor. On all the other actuators, that jumper must be set to the other position (deactivated). Addressing button LED (function code) Jumper Bus termination Assignment of terminals 12VAC1 12VAC2 CANH CANL GND X1 12VAC1 12VAC2 CANH CANL GND X2 7814z01e/1002 The 2 terminal blocks (X1 and X2) are identical. 7/8

ø10 Dimensions Dimensions in mm SQM45... / SQM48... ø5,4 SQM45... ø16 1,5 ø10 7814m07e/0409 Prepared for self-tapping screws M5, 10 mm deep, todin 7500 Choice of drive shaft lateral view Drive shaft no. to "Type summary Choice of drive shaft vertical section SQM45... ø18 ø16 ø10 Groove for Woodruff key 3x3.7 DIN 6888 D-shaft 5 ø14 Groove for parallel key A5x3x28 to DIN 6885 T3 7 8/8 2009 Siemens HVAC Products GmbH Subject to change!