Checklist of points before submitting a Building Warrant Application for an extension to a dwelling

Similar documents
DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

Residential Inspection Guidelines

Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture

Building Control Guidance Note

Sample Drawing Package for One and Two Family Dwelling Applications

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

Energy Company Obligation (ECO): Technical Monitoring Questions

Practice Note

PLEASE REFER TO YOUR INDIVIDUAL QUOTE

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

BUILDING SAFETY UNIT

The Scottish Building Standards TECHNICAL HANDBOOK CONSERVATORIES

Requirements for Building Application Submission

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

Right to Compensation For Improvements

Certification: Building Plans Examiner. Exam ID: B3

The Types of Standard 2 Guidance on the Standards 2 Changes to Legislation 2

September September Consulting Structural and Civil Engineers. 100 St John Street London EC1M 4EH. akt-uk.com

Dealing with damp and mould growth

Commercial Applications

Building Condition Assessment Report

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

Melbourne balcony Assessments

Sports Buildings: budget costs for the Flood Relief Fund

2014 British Columbia Building Code Changes

Timber Frame Construction

THE VOID LETTABLE STANDARD

Property Accreditation Standards 2014/2015

Repair and Renew Grant. Croydon RRG Scheme

Park View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Home Improvement Insurance - UK Landlords

The Scottish Building Standards TECHNICAL HANDBOOK CONSERVATORIES 2 ND EDITION

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist

VILLAGE OF HUDSON FALLS 220 MAIN STREET HUDSON FALLS, NY (518) /

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

Personal Tax Planning - What is a Resiliant or Resistance Measurement?

Residential Building Permit Process

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri

CONTE NT DESIGN PROCESS. Appendix. 01 First Issue. 02 Revision A. 03 Revision B. 04 Co-ordination. 05 Panel Thicknesses. 06 Panel Surface Quality

Basement Development Construction requirements for the development of basements in residential dwellings.

Development Services City of Lawrence, KS

Condition Report SAMPLE. Property address. Client s name. Date of inspection

How to report a repair

October 5, 2015 Dear Client,

VALIDATION REQUIREMENTS FOR PLANNING APPLICATIONS

Basement Waterproofing in Existing Buildings

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

Services Enclosures and Protected Shafts - Maintaining Compartmentation

The Gold Shield Ten Year. Warranty Scheme

Building Warrant Issues

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

Leaky Homes Financial Assistance Package (FAP) Repair plan example

Does Wall Township require an inspection by the building department on resale of a home?

LONDON BOROUGH OF HACKNEY BUILDING SERVICES ENGINEER REPORT GAS HOUSE, SPRINGFIELD PARK, HACKNEY

Solar Panel Installations

Building Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County

Basic Requirements for Residential Plan Review _

Residential Plan Routing Information

Introduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References

Application for Repair and Renew Grant

B-1 Buildings & Service Maintenance

Tenant & Leaseholder Compensation Policy

Measures for reducing risk and increasing

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Guidance on loft conversions in two-storey houses

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Saferand easierinstallation

Simplifying design and construction. Alan Tovey, Director The Basement Information Centre

Module 3.7. Thermal bridging

Chapter 5.4. Waterproofing of basements and other below ground structures

Residential Foundations and Basements

Self-Home Inspection Checklist

Repair and Renew Grant Scheme Leeds - Guidance to Applicants Purpose of the Fund

Walls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open

Patio Covers / Carports

Building Standards Conservatory Roofs Meeting 28 Nov 2012

TECHNICAL RECOMMENDATION

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Excerpts from the Canadian National Building Code (NBC)

A Homeowner s Guide to Building Permits

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

ELIGIBLE REPAIR PROJECT PARAMETERS


- 5 - Table1. Maximum Compartment Volumes

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet.

RESPONSIBILITY FOR REPAIRS AND MAINTENANCE FAIR FUNDING: April 2002

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

The Gold Shield Park Home. Warranty Scheme

Minimum Housing and Health Standards

Structure Survey Findings:

Transcription:

Checklist of points before submitting a Building Warrant Application for an extension to a dwelling This is a list of basic specification notes and the most commonly noted objections and that our surveyors find when checking building warrant applications. If you use this list to check your plans and specifications against, prior to submitting you building warrant application, it will speed up the application process. The list is not exhaustive as every project is unique but by using the list you should have covered the basics. The application will be fully vetted upon receipt. General points that apply to all applications A completed Building Warrant Application Form together with the appropriate fee, plans, specifications etc. The form should contain the applicants name, address, phone and email address. Where an agent is being used, the agents name, address, phone and email address should also be provided. Where we are provided with an email address, all correspondence will be sent via email. This speeds up the application process. Please note applications received by post will have the stamped plans and building warrant sent back by post, once approved. Applications received online will have all correspondence including the approved building warrant sent back online. Please mark the plan/drawing on which the points below have been specified/marked and submit with your application Please provide 2 copies of all plans and specifications as follows:- A block/site plan at a scale of 1:200 or 1:500 A location plan at a scale of 1:1250. The site should be clearly outlined in red ink Elevations and floor plans of the building as existing at a scale of 1:50 or 1:100 Elevations and floor plans of the building as proposed at a scale of 1:50 or 1:100. A larger scale proposed floor plan of 1:20 may be required where the nature of the works is complex. Plans should show proposed works coloured as per the Procedural Regulations. Sectional elevations through the proposed works at a scale of 1:50. Larger scale sections at a scale of 1:20 may be required to clearly indicate specific construction details Fully dimension plans. Include all critical dimensions and

clearly designate use of rooms. A full construction specification. This can either be clear notes added to the plans or a separate specification sheet to be read in conjunction with the plans. Generic specifications are not suitable. All specification should be specific to the actual works applied for. If applying and submitting plans online, a separate specification sheet that can be read in conjunction with the submitted plans is preferable. All plans must have a title block detailing the applicants name, the site address, a description of the plan, the scale the plan is drawn to and a unique reference. Clarify the age of the property to determine which category the U values should comply with within clause 6.2.9 of the Domestic Handbook 2010 General points for a simple extension Substructure:- Foundations to be to the same depth as the existing foundations or 450mm, whichever is greatest Specify size of foundations Provide a fully dimensioned foundation layout plan Specify below ground wall construction Cavity below ground level requires to be filled up to ground level Specify solumn construction Indicate DPM to solumn DPC to walls require to be minimum 150mm above ground level Provide section plan through substructure (if required) Provide annotated drainage layouts (existing & proposed) showing foul and surface water drains. Show connection of new drainage to a suitable existing drainage system. Suspended Ground Floor/Mid Floor (timber or concrete):- Specify floor construction Indicate and specify sub floor ventilation on floor plan and elevation

150mm clear air space required between solumn and underside of floor joists/floor slab Provide floor joist layout plan including all joist sizes, joist centres and dwanging Specify depth of floor slab Specify support to floor joists/suspended floor slab Indicate and specify insulation to ground floor and provide a u value calculation Specify size and type of floor boards If chipboard flooring used, moisture resistant flooring is required to kitchen and bathroom areas Solid Ground Floor:- Specify ground floor construction Indicate and specify damp proof membrane to floor Indicate and specify insulation to floor and provide a u value calculation External Walls:- Specify external wall construction If block work used, specify density of blocks Specify wall ties Specify method of tying new walls to existing Specify insulation to external wall and provide a u value calculation Specify lintels to openings Specify cills to openings, including DPC Specify cavity closers, including DPC Indicate and specify movement joints to walls, if required Timber Frame External Walls (points additional to those above):- Provide timber panel drawings Provide a nailing schedule Specify anchor straps to kit and indicate on plans

Indicate and specify moisture barrier and vapour membrane Specify cavity barriers and indicate on plans Specify cavity ventilation Indicate fire protection to walls within 1m of any boundary Roof:- Provide a roof member layout plan If hand cut trusses to be formed on site, specify all roof timber sizes. The design may require to be accompanied by design calculations. If pre manufactured trusses to be used, provide a roof truss design certificate. Specify under felt Specify baton and counter baton sizes Specify roof covering Specify tie down straps, truss clips, lateral restraints Specify valley gutters (if applicable) Specify ventilation to roof voids Specify roof insulation and provide a u value calculation Electrical Installation:- All electrical works to be to BS7671 : 2008 (17 th edition of IEE Regulations) Electrics to be installed and/or tested by a SELECT or NICEIC approved electrician. An electrical certificate will be required before completion is approved. Indicate all lighting points and sockets on plans Specify height of sockets and light switches on plans Indicate and specify all mechanical ventilation on plans Show all mechanical vent terminals on elevation plans Extend smoke detection/heat detection system to extension where required and show on the plans.

Gas/boiler installation:- A GasSafe registered engineer should be employed to undertake any proposed boiler installations Please indicate a carbon monoxide detector on the plans Plumbing/Drainage :- Please indicate all existing and proposed underground drainage Please indicate all proposed internal pipework All wash hand basins and WCs require to be fitted with water saving devices Glazing:- Please specify u value to glazing Please specify locks to vulnerable doors and windows. Refer to Secure by Design standards Please specify any low level glazing (under 800mm from floor). Low level glazing to be toughened Please indicate and specify escape windows where required Please indicate opening configuration for all windows and doors Stairs and landings:- Specify all internal and external stairs and landings Miscellaneous:- Sound proofing. Depending on the layout, apartments require to be individually soundproofed. Party walls. If required, please specify any party walls Please add this note to the plans The Relevant Person is responsible for ensuring all works are carried out in accordance with The Building (Scotland) Act 2003, as amended, and The Building (Scotland) Regulations 2004, as amended. The building warrant will be subject to a Construction Compliance & Notification Plan (CCNP) that will be issued when the warrant is approved. The CCNP requires that you contact us at all stages listed on the CCNP when ready for inspection.