Room pressure is the difference in pressure between the room itself and the reference it is being compared to.

Similar documents
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

Exhaust Calculation Booklet

Environmental Monitoring

PANDA SPRAY BOOTH FILTER INFORMATION

Air Hockey Training Camp Care and repair of your Air Hockey Playfield

FIRE DAMPER APPLICATION GUIDE

1 DESCRIPTION OF THE APPLIANCE

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Air Hockey Training Camp Care and repair of your Air Hockey Playfield

2003 ACCORD - Automatic Transmission Removal

Standardized Terminology for Combustion Appliances and. Combustion Safety Testing

AABC Specifications for Testing and Balancing HVAC Systems

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

RPV - RP - RA air handling units

Geismar Site Reviewed: 07/05/16 Effective: 07/05/16 Supersedes: 08/04/14 Preparer: Owner: Approver: S/IH Team Leader S/IH Team Leader Manager LA Hub

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

Industrial Ventilation Design Guidebook Chapter 10 LOCAL VENTILATION

Commercial Air is the smart choice for top air conditioning performance and the best value for money system around.

THE ARTIFICIAL INCUBATION OF EGGS FOR BEGINNERS:

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Use and Care Manual. Model CPA12KH AIR CONDITIONER

RESERVDELSLISTA NORMFINISH DP14

Model 201 Wiegand Touchpad Reader Installation Guide

Installation, operation and maintenance manual TX 35A

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

How To Reduce Noise From A Test Screen

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

1.2 Refrigerant Equipment. General

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

MASTER CYLINDER. Section 2. Master Cylinder. Tandem Master Cylinder. Master Cylinder

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Chapter 3.5: Fans and Blowers

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

Taurus Series YORK Window Air Conditioners

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

CE6500 Energy Recovery Ventilator

COOPER S PULLEY UPGRADE KIT INSTALLATION INSTRUCTIONS PART NUMBER NME5011

HOSPITAL ISOLATION ROOM HVAC SYSTEM DESIGN

Selection and Use of Water Meters for Irrigation Water Measurement 1

ASX7-4-IOM-7 J

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

ENGINEERING DATA. Fan Performance Troubleshooting Guide

Air Conditioning Clinic

Fuel System Description. Stromberg 175 CD-2 SE And SU-HS 6 Carburettors

Innovent LASER Packaged Fresh Air Conditioning Units

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Thermo Top - Troubleshooting Tree

HVAC Code Requirements

General Information... 2

SECTION AIR INLETS AND OUTLETS

Accessory Manual Ventilation Section Model Comfort Circle

- White Paper - Data Centre Cooling. Best Practice

Portable Air Conditioner

Experimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

Condensation. Some Causes, Some Advice

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Installation and maintenance instructions. Danfoss Vent

Fume Hood Questions and Answers

3 IN 1 BATHROOM HEATER

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

E-PDD Duct Smoke Detector Installation Sheet

Fan and Pad Greenhouse Evaporative Cooling Systems 1

HVAC Design Requirements

SHOT BLAST CABINET MODEL NO: CSB20B

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

How to Maintain an Air Conditioner

Incorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

DOE-HDBK Module 2.18 Air Sampling Equipment. Instructor s Guide

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

IMPORTANT SAFETY RULES TO FOLLOW

Topvex SX/C, Topvex TX/C. Air Handling Unit

Fig. 2 Option 1 Integrated Design using Physical Separation. Fig. 1 Standard Modular Process Skid Design Concept

Cooking at the Speed of light!

How to Measure HVAC System Airflow

PORTABLE AIR CONDITIONER

Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

Transcription:

Why Measure Room Static Pressure? What is Room Static Pressure? Room pressure is the difference in pressure between the room itself and the reference it is being compared to. If the room pressure is measured at +5Pascals (Pa) / 0.02 Inches of Water Column ("WC), and the reference is to the outside, this means that the air pressure in the room is 5Pa / 0.02 WC higher than A room will show a positive pressure if it is well sealed, and the volume of air being supplied into the room is greater than the volume of air being extracted from the room through the incubators and other exhaust systems. Why is room air pressure important? Incubators are designed to operate with a certain pressure differential between the intake and the exhaust. Too high or too low pressure differentials across the incubator can impair the flow of air through the incubator. This will affect the performance of the incubator and may compromise embryo development. Most hatcheries operate on a slight pressure gradient between rooms to keep air from the dirtiest parts of the hatchery (chick and wash rooms) from getting into the cleaner areas (egg store and setters). Why Measure Room Static Pressure? 01

How To measure Room Static Pressure Units of Measurement The most common units used to measure room pressures are Pascals (Pa) or Inches of Water Column ("WC). There are 2.5Pa per 0.01"WC. Inches of Water Column ("WC) Pascals (Pa) 0.01 2.5 0.02 5.0 0.04.0 0.08 20.0 0.12 30.0 Pressure Meters Pressure meters come in a variety of types and are known as manometers. Connection Tubes A simple, portable and accurate meter is the floating ball meter. This can measure both positive and negative pressure. Positive Port Negative Port How To measure Room Static Pressure Dial type meters, calibrated to measure both positive and negative pressure are also useful. Digital meters are also suitable. Before buying a manometer, confirm the required pressure range of your specific incubator type. For example, do not buy a manometer with a range of 0-60Pa (0-0.24"WC) if your rooms are only going to operate at +5Pa (+0.02"WC). 02

Reference Point Outside Air Pressure Room pressure should always be measured relative to the outside However, a room in the middle of a hatchery will often have several other rooms between it and the outside, all of them operating at slightly different pressures and none of them open to the outside. Here, measure room pressure relative to the roof or a passage, having first confirmed that the reference space is at ambient pressure. Note: It may be impossible to have a reference room at equilibrium to the outside air. If so, find the reference room pressure relative to the outside air and then add this second measurement to the difference between the room of interest and the reference room. However, this method will increase the likely error in the measurement, so it is worth making every effort to create a proper reference room. Options for finding a Reference Point 1. Measure relative to the roof space It is often easiest to use the roof space as a reference point. Make sure the roof space is neutral by checking the pressure relative to the outside through a door or roof hatch. If the pressure reading is 0, then the roof space is at If it is positive or negative relative to the outside, open doors in the roof space until the pressure is neutral. Once the roof space is neutral, measure the pressure of the room of interest through a small hole in the ceiling of the room. How To measure Room Static Pressure 03

2. Measuring relative to a passage First, check if the passage is at This can be done by opening all internal doors along the passage from the room to a point where the passage can open to the outside such as a window or door. Measure the passage pressure at this point. If the pressure reading is 0, then the passage is at If the pressure reading is positive or negative, open an external door or window in the passage to equalise the pressure to the outside and then measure again. Once the passage is neutral, go back to the room of interest (keeping all the inter leading doors along the passage open) and measure the room pressure through the door seal. 3. Measure directly to the outside If the room has an outside wall, then a small hole can be made in the wall directly to the outside. The outlet will need to be protected from the wind such that it is surrounded by still air. Measure the room pressure directly relative to the outside through the hole. How To measure Room Static Pressure 04

How To Use the Pressure Meter Read the operating instructions, which will give directions on how to hold the meter while measuring, and how to calibrate it. The meter will have both a positive and a negative port, and either one or both of these will have a plastic tube attached. Start by assuming that the rooms will be operating close to their design specification, and will be running at positive or negative pressure relative to atmosphere accordingly. - + If measuring from within a positive room to the outside/roof, then attach one end of the tube to the negative port and put the other end through the hole/door so that it is outside the room. If standing outside a positive room (in the passage or roof) you want to measure, place one end of the plastic tube on the positive port and put the other end of the tube through the door/hole into the room. In both cases above if the meter shows a positive reading or the dial moves to the right, the room is positive. Connect the tubes opposite to the above if measuring a negative pressure room. Take Care! The outside reference point will need protection from the wind. The opening into the reference point should be small enough to prevent any airflow around the tube. If measuring across a door or window frame, make the opening as small as possible by closing the door or window against the tube, making sure not to pinch or squeeze the tube in the process. The manometer should be held vertically. Drill a 6.5mm opening Opening into the reference point Outside reference point Measuring across a door or window frame How To Use the Pressure Meter 05

Troubleshooting If the pressure reading seems to fluctuate or is otherwise unstable. Check the shield around the reference point opening to the outside air. Switch extractor fans off in rooms being used as a reference point and check that the room still has a neutral pressure to the outside. Make sure that the rubber tube of the manometer is not blocked from pushing it through the measuring hole. If room pressure is not as expected. Check the reference point is correct. Check air inlets and filters are not obstructed or dirty. Check fan speeds, fan belts and fan blades are as they should be (bent or damaged fan blades will limit the effectiveness of the fan). Check the ventilation dampers are working correctly. Check the Air Handling Unit (AHU) filters and fan settings. Dirty air filters Worn fan blades Troubleshooting 06