150 Series Drawout Motor (MVD) and Feeder (FVD) Protection Relays

Similar documents
Eaton s E-Series protective relay family

Disturbance Recoder SPCR 8C27. Product Guide

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Install the DeviceNet Module using the following procedure:

Permissible ambient temperature Operation Storage, transport

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

E-Series protective relay family

M2M The measure of efficiency

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

T Substation Maintenance and Commissioning Test Equipment

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Applications. diris_826_a_1_gb_cat

Installation manual. Generator Paralleling Controller GPC multi-line C

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Generator Differential Relay Electrical Apparatus

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

CSDPR. Multi Powered Over-Current Relay

FREJA 300 Relay Testing System

Polyphase kwh Electricity Meter

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Digital multimeters DMG

Safety technique. Emergency stop module BO 5988 safemaster

Multi-Range Programmable DC Power Supplies 9115 Series

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Power Meter Series 700

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

LogicLab s.r.l Via della valle Carate Brianza (MI) Tel Fax

32VFD Variable Frequency Drives for Centrifugal Chillers

Quick Connect. quick - simple - efficient.

Temperature & Humidity SMS Alert Controller

Voltage Regulator SPAU 341 C. Product Guide

PCS0100en Persy Control Services B.V. Netherlands

Installation and User Guide

Contact expansion modules

Contact expander modules

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

High Power Programmable DC Power Supplies PVS Series

Products and solutions for lifting systems

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

How To Protect Your Power Supply From Dangerous Currents And Voltages

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

1 Application Description Objective Goals... 3

Application/Connection Examples

Capacitor Protection Relay SPAJ 160 C. Product Guide

SMS GSM Alarm Messenger

GB USER S MANUAL GB 41

PNOZsigma - Base units

ABB PSPS Erich Steinmann; Generator control-2013

PLA 44. Power quality analyzer. User and service manual. BMR trading

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

FP-4000 Feeder Protection

Sentron Series Circuit Breakers

DME4 V1.23 ( ) V1.30 ( ) V1.31 ( ) V1.32 ( ) V1.33 ( ) V1.34 ( ) V1.35 ( ) V2.00 ( ) V2.

MLC TM Maximum Productivity and Versatility for Control without Compromise!

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

NIM High Voltage Power Supplies

Automatic Transfer Switch Controller

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

Electronic Control Devices The European Product Catalogue 2007

E-STOP relays, safety gate monitors

Technical note NT588 NT604 NT695 NT782

Data Bulletin. Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers. Introduction. Thermal-Magnetic or Electronic Trip Unit?

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Product Information Sheet UH36 Hi Pot Tester

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Maximize protection. MiCOM series 10, 20, 30, 40. Make the most of your energy. Comprehensive range of digital protection relays

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Repeaters and Mimics Data Sheet

Number 1 in efficiency

1.44 kw Programmable DC Power Supplies XLN Series

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

NC-12 Modbus Application

Feeder protection. for overhead lines and cables in isolated neutral or compensated networks. Specification

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Square D Model 6 Motor Control Centers

HI/ICMI UVR-1 Universal Voltage Regulator Control

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Products and solutions for pumping, irrigation and piping

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Energy Management Energy Meter Type EM23 DIN

Uninterruptible Power Supply

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

Energy Management Power Analyzer Type WM14-96 Basic Version

Helmut Schoenfelder, ABB Stotz-Kontakt, UMC100.3 Technical Presentation. ABB Stotz-Kontakt May 18, 2015 Slide 1

Transcription:

150 Series Drawout Motor (MVD) and Feeder (FVD) Protection Relays Intelligent Protection and Control Field programmable front panel, including LEDs and display. Withdrawable case structure featuring self shorting CT contacts on removal. Support for Ethernet, IEC 61850, MODBUS TCP/IP. Serial, MODBUS RTU, P&B Network Gold and PROFIBUS DP. Simple and Easy to use menu interface Comprehensive Protection for MV and LV systems Designed for high temperature industrial environments 75 years experience of providing world class protection products

Functional Overview The MVD and FVD protection relays provide many functions, these include multiple communication options, a range of I/O configurations including programmable external inputs, trip circuit supervision protection, programmable outputs and configurable LEDs making the 150 Series relays a complete solution for MV and LV applications. Serial Engineering Workstation Ethernet Distributed Control System Digital Inputs * Feeder Protection Digital/Relay Outputs * Motor Protection Serial TCS Transformer Feeder PC Relay Programming Software Motor Trip Circuit Supervision Protection (* Dependent on relay type chosen) Hardware Overview Operating temperature range -20 C to +85 C Auxiliary power supply voltage range 80 265Vac/dc or 24-48Vdc 1A or 5A ac current inputs I1, I2, I3 and I0 500Vac maximum ac voltage inputs V1, V2, V3 and V0 Twelve programmable digital inputs Upto three programmable relay outputs with changeover contacts Upto seven programmable LED status indicators Two channel trip circuit supervision protection RS232 programming port Serial RS485 or Ethernet communication 128 x 128 graphic liquid crystal display Time Synchronsiation Serial and NTP Optional conformally coated circuit boards

Protection Overview U U U U Motor U U Voltage Inputs V1, V2 and V3 *Optional Neutral Voltage Vo Two Channel Trip Circuit Monitor Current Inputs I1, I2 and I3 Current Input I0 MVD Motor Protection Relay 27 59 86 81 U O Undervoltage Overvoltage UV Lockout Frequency *59N Overvoltage *TCM Trip Circuit Supervision 49 Thermal Overload 50/51 N Earth Fault 14 Speed Switch 37 Undercurrent 47 19 Phase Rotation 50 BF Overcurrent Short Circuit Breaker Fail Start Protection 55 Communications Module 86 74 Serial Inhibit 95 Overpower 51 Overcurrent/Stall Load Increase Power Factor 66 Starts Per Hour 46 Single Phasing Phase Unbalance Serial Timeout Disturbance Recorder 32 Event Alarm and Trip History, Last 5 fault with trip data. 1mS Time & Date Stamping Programmable Front Panel LEDs Ethernet Communication Port* Trip Circuit Supervision* Smart Card (settings/data) 128x128 Large Graphical LCD Multiple Motor Starter Configurations supported, such as DOL, Two-Speed, Star/Delta and others. Instantaneous Metering Serial Communication Ports 10 x Programmable External Inputs with Custom Strings IEC61850*, MODBUS TCP/IP*, MODBUS RTU, P&B Gold and PROFIBUS* Statistical and Historical Info. Display Mimic showing breaker Motor Status * Optional Functions 52 U U U U U Breaker U U Voltage Inputs V1, V2 and V3 27 *Optional Neutral Voltage Vo Two Channel Trip Circuit Monitor Current Input I0 Current Inputs I1, I2 and I3 FVD Feeder Protection Relay Undervoltage *59N Overvoltage *TCM Trip Circuit Supervision 50/51 N Earth Fault 1 EF 2 HS 50 Overcurrent LS Overcurrent HS 59 81 U O Overvoltage # 50/51 N Earth Fault 2 EF 2 HS 51 Overcurrent 1 Overcurrent 2 Load Increase Frequency *67N Directional Earth Fault 95 Overpower Communications Module 50 BF 74 Serial Timeout Breaker Fail 79 Auto Reclosing Disturbance Recorder 32 Event Alarm and Trip History, Last 5 fault with trip data. 1mS Time & Date Stamping Programmable Front Panel LEDs Ethernet Communication Port* Trip Circuit Supervision* Smart Card (settings/data) 128x128 Large Graphical LCD Breaker Wear Monitor Peak Demand Metering Instantaneous Metering Serial Communication Ports 12 x Programmable External Inputs with Custom Strings IEC61850*, MODBUS TCP/IP*, MODBUS RTU, P&B Gold and PROFIBUS* Statistical and Historical Info. Display Mimic showing breaker Status * Optional Functions # Dependent on software config.

Feature Overview Large 128 x 128 graphic liquid crystal display. Provides clear concise information, multiple messages can be viewed along with detailed fault/troubling shooting data, such as disturbance recording data and motor start curve Smartcard interface port, allowing external Settings/Data storage Easy to use four button menu interface RS232 port allowing simple programming and data extraction from the relay via a PC. Programmable front panel LEDs to indicate user defined relay status Optional Ethernet communication port, MODBUS TCP/IP or IEC 61850 Power supply options 80 265Vac/dc and 24-48Vdc Programmable digital inputs, with editable custom string options Four programmable output relays with changeover contacts Optional two channel Trip Circuit Supervision (TCS) monitor High speed RS485 serial communication port CT inputs, 3 phase + Earth fault. CT inputs have self shorting contacts, which engage when relay is removed from the case. VT inputs, 3 phase + optional neutral voltage input All connectors are equipped for both screw and crimp terminals Optional IEC 61850 programming/upgrade port interface

User Interface and Programming The LCD menu is driven by four push buttons, this allows access to measured and recorded data as well as providing a programming interface for the relay settings. The large display allows the menu to be structured in an intuitive way to allow ease of use and clear understanding of the presented information. The 150 Series Drawout relays provide three ways to quickly and easily configure the protection and systems settings required to put the relay into service. One method is via the large liquid crystal display using the simple and intuitive menu structure, the second method is via a personal computer and the P&B dedicated Vision Control software and the third method is via a portable smartcard. Vision Control Software The Vision Control software is a Windows based PC program offering a graphical user interface allowing full access to the P&B Vision relays, key features are shown below. Designed to allow online/offline programming of all P&B Vision Relays One parameter file can store data for upto 32 devices as per a typical RS485 network Single drives or complete networks are supported, there is no limit on the number of Parameter files, which can be used/saved. Metering and Historic data is readily available for download/viewing Disturbance Recording data extraction (COMTRADE format) Support for relay firmware updates Support for Smartcard programming

Fault Reporting and Troubleshooting The 150 Series relay comes equipped with an extensive range of features designed to help and determine the order and cause of events, to aid and assist in troubleshooting and rootcause analysis. All events and waveforms captured are time and date stamped with a resolution of 1mS. Disturbance Recorder Overview Disturbance and fault recording is a very effective tool for the operating and design personnel to analyse the performance of the power system and related equipment during and after a major disturbance. P&B s Disturbance and Fault Recorder System acquires the conditions in an electrical system that lead to (pre-fault), persist during (fault) and follow the fault (post-fault) for subsequent analysis. The analysis provides a detailed insight, with time resolution in milliseconds, into the behaviour of the electrical system. Each relay can be equipped with its own onboard disturbance recording facility. This can provide up to 8 seconds of waveform capture and can be multi triggered and weighted pre and post fault. Each current and voltage phase is individually recorded along with one programmable digital input and one programmable digital output. Uniquely, due to the powerful graphical display, waveform traces can also be viewed directly at the relay with zoom and scroll functions without the need for any external equipment. Alternatively the waveform data maybe extracted from the relay using the front RS232 port in a COMTRADE format for analysis by any compatible software. For motor protection the disturbance recorder can be set to trigger on a motor start, this allows a complete capture of the motor start event providing a graphical capture of the actual waveforms allowing the user to easily troubleshoot any problems with motor starting. Fault Event Overview This allows upto 32 trip and 32 alarm events to be recorded all with time and date stamping, with a resolution of 1mS. The last 5 events, both for trip and alarm come complete with all the pre-trip data, this includes all current and voltage values, power, power factor and any other relevant data associated with the trip or alarm. The event recorder memory capacity can be increased through the use of an external smartcard. Through the use of the smartcard sequence event records can be recorded. This allows the tracking of control inputs, control outputs, command inputs, trip/alarm events and auxiliary power dips/losses. The time and date of each event are available in the report.

Specifications Auxiliary Power Supply & Low Voltage Power Supply AC Nominal Range 80 265V AC / DC Range 24V AC / 24-48V DC (Low Voltage Power Supply Optional Extra) Maximum Power Consumption 10VA Nominal Operating Temperature Range 150 Series Protection Relay -20 C to +85 C IEC 61850 Communication Card -40 C to +85 C Phase Current Measurement Method Range Full Scale Display Accuracy Pick Up Accuracy Earth Phase Current Measurement Method Range True RMS, Sample time <1ms 0.1 to 25x Phase CT Primary Amps 25 x Phase CT Primary Amps Setting ± 3% at Phase CT Primary amps ± 3% of setting True RMS, Sample time <1ms 0.01 to 2.5x E/F CT Primary Amps (MVD) 0.10 to 25x E/F CT Primary Amps (FVD) Full Scale 2.5 x E/F CT Primary Amps Setting (MVD) 25 x E/F CT Primary Amps Setting (FVD) Display Accuracy ± 3% of Reading Over Range Pick Up Accuracy ± 3% of setting CT Burden 0.1VA Voltage Reference Measurement Suitable for connection preferably via isolating transformers (VT) or direct connection to max phase to phase system voltage not exceeding the rated voltage. Method True RMS, Sample time <1ms Rated Insulation Voltage 1000V Range 100 500V AC up to 22kV with external VT Display Accuracy ± 3% Power Accuracy VT Burden ± 5% of Nominal 0.01 VA Overload Alarm and Trip Curves Fault Time Accuracy ± 50mS up to 10 seconds ± 2% of trip time over 10 seconds Threshold Current Level Overload Setting ± 2% Current Unbalance Alarm and Trip Method Unbalance = 100 x (Imax - Imin) / Ir % Where Imax = max. of 3 phase currents Imin = min. of 3 phase currents Ir = Larger of Imax or Motor FLC Alarm Threshold Unbalance Level 50% of Unbalance current ± 2% Alarm Fixed Time Delay Accuracy 1.0 ± 0.1 seconds Trip Threshold Unbalance Level Unbalance Current Setting ± 2% Trip Time Accuracy ± 0.1 second up to 10 seconds ± 0.1 second +/- 2% above 10 sec. Time Delays Accuracy ± 0.5 seconds or ± 2% of time Exceptions Earth Fault Trip +150mS,-0.0@ 1.1 x setting +60mS,-0.0@ 2 x setting +40mS,-0.0@ 5 x setting Total Run Time Accuracy ± 2% Auto Restart delay on Restart Time ± 0.2 seconds ( additional 2 second initialisation time delay if aux. supply lost) Output Relays Rated Load (at various supply voltages) Continuous Thermal Load Max Making Current (max. 4s at duty cycle 10%) Bounce time N/O contact / N/C contact Contact Protection 10A @ 250 AC 10A @ 30V DC 0.6A @ 110V DC 0.1A @ 220V DC 10A 35A 0.6 / 17 ms 385V DC, 47 J MOV across both normally closed and normally open contacts

Application Overview MVD Typical Application 150 Series Terminal Connections LIVE 1 2 NEUTRAL Digital Input 3 29 30 Digital Input 4 Relay 1 NC Relay 1 C 3 5 4 6 Relay 2 NC Relay 2 C Digital Input 5 Digital Input 7 31 33 32 34 Digital Input 6 Digital Input 8 Relay 1 NO 7 8 Relay 2 NO Digital Input 9 35 36 Digital Input 10 Relay 3 NC 9 10 Relay 4 NC Digital Input 11 37 38 Digital Input 12 Relay 3 C 11 12 Relay 4 C TCS 1 + 39 40 TCS 2+ Relay 3 NO 13 14 Relay 4 NO TCS 1-41 42 TCS 2-485 + 15 16 485 - TCS O/P 1 NC 43 44 TCS O/P 2 NC 485 Gnd 17 18 EARTH TCS O/P 1 C 45 46 TCS O/P 2 C Digital Input 1 19 20 Digital Input 2 TCS O/P 1 NO 47 48 TSC O/P 2 NO I1 High 21 22 I1 Low V1/I4 High 49 50 V1/I4 Low I2 High 23 24 I2 Low V2/I5 High 51 52 V2/I5 Low I3 High 25 26 I3 Low V3/I6 High 53 54 V3/I6 Low Io High 27 28 Io Low Vref High 55 56 Vref Low

FVD Typical Application

156.00 mm 150.00 mm 127.00 mm 23.00 mm 178.00 mm Designers and Manufacturers of Motor and Feeder Integrated Protection Control & Monitoring Systems 168.00 mm 158.00 mm P&B Protection Relays, Belle Vue Works, Boundary Street, Manchester M12 5NG UK Tel: +44 (0)161 230 6363 Fax: +44 (0)161 230 6464 http:www.pbeng.co.uk mail@pbeng.co.uk ø 4.30 mm 104.00 mm Enclosure Cut Out Dimensions