Gasmesscomputer GMC from Version 1.0. Output Extension RK Data Sheet. Gas Detection and Warning Systems

Similar documents
FIREDEX Conventional Fire Panels

TMS TANK MANAGEMENT SYSTEM

Conventional Fire Detection and Extinguishant Control System Specification

Duct Humidity Transmitter

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Product Information Fire alarm panel 8000 C

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Product Information Sheet UH36 Hi Pot Tester

Input module, input/output module

CONFIGURABLE SAFETY RELAYS

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Preset Counter signo 721

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Quick Connect. quick - simple - efficient.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Chapter 9 N.C. C. N.O. Single-Pole Double-Throw

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Digital display DA 48

WD-AMX Water Detection Controllers

NC-12 Modbus Application

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

SMS GSM Alarm Messenger

Modular I/O System Analog and Digital Interface Modules

PROTEC CIRRUS HYBRID ASPIRATING SMOKE DETECTION SYSTEMS

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

RRV934. Multi-controller. Synco living

connecdim Gateway G1 Ethernet TCP/IP to DALI

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

LED - Indicator Panels

ACS-30-EU-EMDR-10-MOD

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Digital inductive conductivity transmitter

Repeaters and Mimics Data Sheet

Combi switchbox with integrated 3/2 way pilot valve

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

I STAR COMPUTER CO., LTD

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

SYSTEM DESCRIPTION Termination Boards

HWg-STE HWg-STE PoE MANUAL

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

Electronic Control Devices The European Product Catalogue 2007

LC/LCD ranges level controllers

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Temperature & Humidity SMS Alert Controller

Digital Single Axis Controller

J TB/TW Temperature limiter, temperature monitor

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Electronic Control Devices The European Product Catalogue 2007

Programming Logic controllers

Remote Monitoring and REC 501 Control Unit Product Guide

instabus KNX / EIB System System E F G H

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Air conditioning, electrical testing

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

CONFIGURABLE SAFETY RELAYS

Catalog. Arc Guard System TM TVOC-2

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Busch-Watchdog Presence EIB Type:

EBDSPIR-PRM, EBDSPIR-PRM-IP

UM-X Field display for continous level sensors

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

PowerGem Pro Uninterruptible Power Supply

DKG 972 Gas Burner Safety Control

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

FIRERAY 2000 Installation Guide

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

GSM Alarm System User Manual

ABB i-bus KNX Fan Coil Controller FC/S 1.1

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

R001. Room Control Unit TG650. Summary. Control functions. Orders. Planning. Installation

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

EBDSPIR-DD, EBDSPIR-DD-IP

Centro-Matic Automatic Lubrication Systems System Controls

GSM HOME SECURITY SYSTEM

Tina 2A/B Adaptor unit

Manual. Solar Fountain Mobile Phone Charger

COMPALARM AP GENERAL MAIN FEATURES


Triple Waveband Infra-Red Flame Detection

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Product Information Sheet UH28CS-12kV Hi Pot Tester

Application/Connection Examples

DUCT SMOKE DETECTOR D4120

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Transcription:

Gasmesscomputer GMC 8420 from Version 1.0 Output Extension RK 8420 Gas Detection and Warning Systems

Application The controller Gasmesscomputer GMC 8420, in conjunction with detectors that supply 4-20 ma output signals, has the following functions: Measurement and display of the gas concentration Monitoring these gases and warning of their presence Triggering protective measures to counter increasing concentration. Set-up Detector Controler A gas warning installation consists of the following components: An evaluation system A detector Controllable devices, such as: - fans - solenoid valves - horns - illuminated warning signs Product Features Type of installation: wall-mounting Evaluation System GMC 8420 Four measurement channels Concentration display Two alarm stages and additional horn output Microprocessor technology provides numerous functions and simple operation Verification of alarm signal without test gas Fault monitoring for: - mains failure - computer defect - wire break / short circuit of sensor leads Potential-free relay outputs for: - 3 freely programmable relays for Alarm 1, Alarm 2, Horn - 1 error message relay Output Extension RK 8420 Type of installation: wall-mounting Optional extension of relay outputs - 4 freely programmable relays for Alarm 1, Alarm 2, Horn Page 2 Technical Status: 11/2010

How It Works The controller is designed to be connected to up to four gas detectors with 4 20 ma signal interfaces. In the event of an alarm, the relay outputs of the controller can switch technical safety measures, for example, to close a solenoid valve in a gas supply line. A built-in buzzer provides an acoustic alarm. In addition the unit has four built-in DC switches for 32 VDC/ 200 ma, which can be used for further switching operations. The Ready LED shows that the controller is ready for use. The Measure LED indicates each measurement. There are also visual indicators for error, prealarm and main alarm for each measurement channel. A fault message (Error LED) is given when the signal is outside the measurement range. The Error LED also indicates a wire break in the detector leads. LEDs A1 and A2 signal when a pre-alarm or main alarm is given. The present reading is shown in the display. The channel number is displayed so that a concentration reading can be correctly assigned. By briefly pressing the Stop button for any desired channel, its reading is continuously displayed. An alarm threshold can be freely assigned to the Horn output which controls an external acoustic device and the built-in buzzer. For the control of technical equipment and warning devices there are three freely programmable output relays (230VAC/4A). These can be programmed with the messages Alarm 1, Alarm 2 or Horn. A further output relay is permanently assigned to the Error function. The output extension RK 8420 can be connected at the integral DC switch. This module provides the option of four more freely-programmable output relays (230VAC/4A). Parameters can be freely set for each measurement channel: - Alarm threshold for Alarm 1 - Alarm threshold for Alarm 2 - Alarm when signal is outside measurement range - Alarm latching / non-latching - Zero capture The system parameterisation is carried out using an RS232 interface. For this operation a simple terminal emulator is necessary. As a rule this software is provided by all operating systems, or it is available on a free licence. Technical Status: 11/2010 Page 3

Technical Data GMC 8420 Number of detectors that canbeconnected Detector inputs External reset Outputs Max. 4 detectors 4x 4-20 ma Yes Potential-free changeover contacts (230 VAC, 4A): -1xError - 3x programmable for Alarm 1, Alarm 2, Horn PhotoMOS relay (32 VDC, 200 ma) - 4x programmable for Alarm 1, Alarm 2, Horn Alarm device Built-in 85dBA signal horn Display elements - Display for concentration - Display for channel number - LEDs for Alarm 1, 2, Error, Ready, Measurement Power supply 100-240 VAC, 50-60 Hz, 20W Emergency power supply 1x 24VDC emergency power supply input Distribution terminals For each: 6 terminals for N and PE, 3 for L Temperature range -10 C to +40 C Relative humidity Air pressure 800 1200 hpa Ambient conditions - Can be used up to 2000 m above sea level - Protect from direct sunlight Storage conditions -10 C to +70 C Degree of protection IP44 Housing Wall-mounting plastic housing (240x190x90 mm) Weight 1300 g Anticipated useful life Typically > 8 years Connections - Mains connection: cable gland for 7-14 mm dia. cable - Cable entries for sensors and switched outputs: double-diaphragm sockets, sealing range 5-9 mm Electrical safety EN61010 EMC requirements EN50270 (Type 2) EN61000-6-3 Ready Measure A3 / 3 4 Error A1 A2 Concentration Channel Stop Reset 190 mm GMC 8420 240 mm 90 mm Page 4 Technical Status: 11/2010

Technical Data RK 8420 Outputs Potential-free changeover contacts (230 VAC, 4A): - 4x programmable for Alarm 1, Alarm 2, Horn Inputs 4 x control inputs from GMC 8420 Power supply Power supply from GMC 8420 Distribution terminals 6 terminals (L, N, PE) for each Temperature range -10 C to +40 C Relative humidity Air pressure 800 1200 hpa Ambient conditions - Can be used up to 2000 m above sea level - Protect from direct sunlight Storage conditions -10 C to +70 C Degree of protection IP44 Housing Wall-mounting plastic housing (160x190x90 mm) Weight 750 g Anticipated useful life Typically > 8 years Connections 2x cable glands for 7-14 mm dia. cables 5x double-diaphragm sockets, sealing range 5-9 mm Electrical safety EN61010 EMC requirements EN50270 (Type 2) EN61000-6-3 190 mm RK 8420 90 mm 160 mm Technical Status: 11/2010 Page 5

Accessories Service Customer-specific Installations Bieler + Lang GmbH Gas Detection and Warning Systems Afriso Ema AB Kilvägen 2, 232 37 Arlöv Tel: 040-92 20 50 Fax: 040-19 33 58 info@afriso.se www.afriso.se