1.0 Introduction and Guided Tour Installation Instructions Commissioning 4

Similar documents
Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide

conventional system operation

CB200W Water Leak Detection Panel Application Guide

ZETA ALARM SYSTEMS PREMIER AL MANUAL

VEGA Analogue Addressable Control Panels

FIREDEX Conventional Fire Panels

MSL1000 Monitored Serial Link Interface Manual V1.01

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Fire Detection Product Range

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Advanced Intelligent Modules. Overview. Description

AlarmSense 2-wire detection and alarm system. Product Guide

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Conventional Fire Detection and Extinguishant Control System Specification

Product Data Sheet. User Manual. User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels

4 Loop Analogue Addressable Control Panels

Modular I/O System Analog and Digital Interface Modules

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL

Product Information Fire alarm panel 8000 C

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Planning Instructions MEW01351 Revision -

ACTIVE 5 ENGINEERING MANUAL

Syncro. Multi Loop Analogue Addressable Fire Control Panel. Product Manual. Man-1055 Issue 21 September 2010

WHO ANSWERED FIRST? FIND OUT WITH THIS QUIZ BUZZER KIT

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

DK40 Datasheet & Hardware manual Version 2

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

Syncro. Multi Loop Analogue Addressable Fire Control Panel. Product Manual Man-1055 Issue 26 May 2016

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Input module, input/output module

TAC I/NETTM. Intrusion Alarm System

D287/D288/D292/D293A/D293E

POLON 4100 FIRE DETECTION AND ALARM ADDRESSABLE CONTROL PANEL

Repeaters and Mimics Data Sheet

Nu-Lec Training Modules

TMS TANK MANAGEMENT SYSTEM

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

SFC-200 SERIES LCD FIRE ALARM PANEL

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

... Electronic Softstarter...

AIS750 Series Alarm Annunciator

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

CKM-EP2500, CKM-EP1501, and CKM-EP1502 Mercury Network Controllers

JUNIOR V3. Fire Alarm Control Panel INSTALLATION & COMMISSIONING MANUAL GLOBAL REVISION 2.3 FIRE EQUIPMENT QUEUE REVIEW STATUS ZONES

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

PLC training panel (Twido version)

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

Syncro AS. Analogue Addressable Fire Control Panel. Product Manual Man-1096 Issue 14 May 2016

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Fire Fighter Phone System Installation Instructions

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Application/Connection Examples

Programming Logic controllers

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

Surveyor Excel-K. Fire Alarm Control Equipment. Installation, Commissioning and Operating Manual

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

OCTOPLUS WARNING AND MEASUREMENT CONTROL UNIT FOR TOXIC AND FLAMMABLE GASES

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Life Alarm Fire Alarm Controls

Control/Communicator Installation Manual

DTW Works Master Specification Version 2006

Fire Alarm Control Panel. Family. Operating Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

MOTION COORDINATOR MC206X Quick Connection Guide

FX 3NET + SLC FIRE ALARM SYSTEM Part 1: General Rules

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

User s Information Guide R1A


Software Release For DF6000/CF3000/FX6000. Site Installer Network Card

Fire alarm system EBL512 G3

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

DCREG INTERFACE VIA DEVICENET

INSTALLATION MANUAL PC2525. Version 1.1

Premier M Plus & Infinity 8

Reversing starter circuit for single phase induction motors Updated 1 st September 2008

FIRE DETECTION SYSTEMS

200 Range Dialer Installation Manual. Version 1.0

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

9452/9453 Installation and User Guide

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panels with Integrated Communicator INS159-9

IRIS Touch 600 Range Dialler Installation Manual. Version 1.3

Installation Manual for D1110 DigiCom2

The supplier and installer of the system should be approved by the local civil defence authority.

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

MEMOBUS/Modbus Communications

PRODUCT LIST Facility DDC Access WebXL DDC

UM0272 User manual. Central Unit for Alarm System (CUAS) Evaluation Board. Introduction

Contents. : AEOS Blue cabling and technical aspects. NEDAP N.V. IDEAS Information Bulletin No: H032. Date : 12 January 2016

TS510 & TS500. Installation & User Guide. Compatible Equipment

RP1r. Extinguishing Control Panel. User Manual (Software version 3.x) 3 zone control panel to protect 1 extinguishing risk

Transcription:

A1535 8 Way Relay Board for Nexus 1-8 Loop Analogue Addressable Control Panels Application, Installation and Commissioning Manual Contents Page 1.0 Introduction and Guided Tour 1 2.0 Node Addressing Details 3 3.0 Installation Instructions 3 4.0 Commissioning 4 Appendices i Technical Specifications 5 ii Other Relevant Documentation 5 1.0 Introduction Up to 31 A1535 (relay) [and/or A1536 alarm] programmable expansion boards may be connected to the Nexus 1-8 loop panel. Two boards may be housed internally within the double-doored Nexus cabinet, the remainder require other enclosures. The A1535 board provides 8 programmable inputs (0V switched) and 8 programmable relay circuit outputs. Document Ref: 1535apin.doc/Rev2 26.04.00 Page 1 of 5 Originator MC Checked by GG Approved byjbj

1.1 A Guided Tour 1.1.1 A1535 8 Way Programmable Input/Output Relay Board RS 485 comms data in/out from A1557 motherboard MUX I/O terminals & to other A1535/ Board A1536 boards address Enable O/C & S/C fault monitoring on inputs 1-8 Disable inputs Disable outputs Fault LEDs Watchdog reset 8X VF relay contacts each reated at 1A 24V DC MX- MX+ MX- MX+ IP1+ IP1- IP2+ LK1 - I/P1 MON DE DIS 4 3 2 1 0 IPOP ON EDGSW1 1 2 3 4 5 6 7 8 Links to isolate open collector & relay output terminals. LK9 - O/P1 + RL 1 LK10 - O/P 2 + RL 2 etc. PROC FAILED COMMSWATCHDOG FAILEDRESET LK9 OP1 RL1 LK10 OP2 LK11 OP3 LK12 OP4 LK13 OP5 RL2 LK14 OP6 LK15 OP7 LK16 OP8 RL3 RELAY OUTPUTS COM RL 1 COM RL 2 COM RL 3 IP2- IP3+ LK2 - I/P2 IP3- LK3 - I/P3 RL4 COM RL 4 IP4+ IP4- LK4 - I/P4 Links to isolate inputs. Open collector outputs 0V 100mA each max. IP5+ IP5- LK5 - I/P5 RL51 COM RL 5 IP6+ LK6 - I/P6 IP6- COM RL 6 IP7+ IP7- IP8+ LK7 - I/P7 LK8 - I/P8 RL6 COM RL 7 IP8-0V 24V 24V DC power in RL7 COM RL 8 RL8 LK17 Buzzer disable link 8X inputs. Either normally open non monitored or O/C & S/C fault monitored as selected on SW1. Document Ref: 1535apin.doc/Rev2 26.04.00 Page 2 of 5 Originator MC Checked by _GG

2.0 Node Addressing Details Set the required board address on switches SW1, according to the table below: Node Address Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 I/O Circuits 1 Off Off Off Off On 1 to 8 2 Off Off Off On Off 9 to 16 3 Off Off Off On On 17 to 24 4 Off Off On Off Off 25 to 32 5 Off Off On Off On 33 to 40 6 Off Off On On Off 41 to 48 7 Off Off On On On 49 to 56 8 Off On Off Off Off 57 to 64 9 Off On Off Off On 65 to 72 10 Off On Off On Off 73 to 80 11 Off On Off On On 81 to 88 12 Off On On Off Off 89 to 96 13 Off On On Off On 97 to 104 14 Off On On On Off 105 to 112 15 Off On On On On 113 to 120 16 On Off Off Off Off 121 to 128 17 On Off Off Off On 129 to 136 18 On Off Off On Off 137 to 144 19 On Off Off On On 145 to 152 20 On Off On Off Off 153 to 160 21 On Off On Off On 161 to 168 22 On Off On On Off 169 to 176 23 On Off On On On 177 to 184 24 On On Off Off Off 185 to 192 25 On On Off Off On 193 to 200 26 On On Off On Off 201 to 208 27 On On Off On On 209 to 216 28 On On On Off Off 217 to 224 29 On On On Off On 225 to 232 30 On On On On Off 233 to 240 31 On On On On On 241 to 248 3.0 Installation Instructions 3.1 Connect MX+ and MX- from the A1535 relay board to the control panel motherboard (terminals MUX I/O) observing correct polarity at both ends. 3.2 Connect 24V and 0V supplies from the A1535 relay board to the power supply unit. This can either be an auxiliary power supply or the control panel s power supply. TE: If an auxiliary power supply is used, then the open collector fault output on the power supply should be connected to the power supply fault monitor input terminals on the motherboard. WARNING: Do not apply power at this stage. 3.3 Connect the output circuit field wiring to open collector outputs or relays, dependent on the configuration of the A1535 relay board. 3.4 Connect the field wiring for all required inputs to the A1535 relay board. There are Document Ref: 1535apin.doc/Rev2 26.04.00 Page 3 of 5 Originator MC Checked by _GG

two ways of connecting, one for monitored inputs and one for non-monitored inputs. 3.4.1 Monitored inputs require a combination of two resistors, a 3K9 end of line resistor which is connected across the switch contact and a 680 Ohm resistor which is connected in series between the positive input leg (IP4+) and the switch contact. 3.4.2 Non-monitored 0V inputs should be directly connected to the positive leg of the input terminals. 4.0 Commissioning 4.1 The first task is to programme the panel to accept the A1535 relay board. This is done in the EDIT C/E Data option on the Nexus panel (Option 9 in the extended menu). See Nexus 1-8 loop Installation & Commissioning Manual. The three valid board types for the A1535 are: Type 2: RELAY (N-MON) Type 3: RELAY (MON) Type 4: RELAY (FIRE) 8 non-latching, non-monitored indication only (ie non fire or fault reporting) inputs which can be used within the panel s cause/effect 8 non-latching, monitored indication only inputs which can be used within the panel s cause/effect 8 latching, monitored fire indicating inputs which can be used within the panel s cause/effect TE: Not suitable for connection to detectors. 4.2 The next step is to programme the desired cause and effect for the inputs and outputs on the A1535 board. The outputs are programmed using the PANEL OUTPUTS option in the EDIT C/E DATA extended menu option. See Nexus 1-8 loop Installation & Commissioning Manual. The inputs are programmed as zones in the ZONE ALLOCATION option. See Nexus 1-8 loop Installation & Commissioning Manual. Cause and effect programming can then be written using these zones. Document Ref: 1535apin.doc/Rev2 26.04.00 Page 4 of 5 Originator MC Checked by _GG

Appendices i Technical Specifications Device A1535 Relay Board Addressing 1 to 31 using DIL switches Communications protocol RS485 Supply voltage 24V DC Quiescent current 100mA Active condition current 100mA + 25mA per active output Maximum supply current 1A Open collector output current 8 x fully loaded outputs, each at 100mA Relay contact rating 8 x 24V 1A changeover contacts Relay rating 30V DC 3 Amps (non inductive) ii Other Relevant Documentation Sales Literature for Nexus 1-8 Loop panel Application Guide for Nexus 1-8 Loop panel Installation & Commissioning Manual for Nexus 1-8 Loop panel Wiring Recommendations After-Sales Technical Support Booklet Document Ref: 1535apin.doc/Rev2 26.04.00 Page 5 of 5 Originator MC Checked by _GG