Trench Etched Resonant Pressure Sensor: TERPS

Similar documents
THE STRAIN GAGE PRESSURE TRANSDUCER

How to measure absolute pressure using piezoresistive sensing elements

MEMS mirror for low cost laser scanners. Ulrich Hofmann

Subminiature Load Cell Model 8417

DATA LOGGING SYSTEM FOR PRESSURE MONITORING

Procon Engineering. Technical Document PELR TERMS and DEFINITIONS

The accelerometer designed and realized so far is intended for an. aerospace application. Detailed testing and analysis needs to be

Ultra High Temperature, Miniature, SOI Sensors for Extreme Environments

Silicon-On-Glass MEMS. Design. Handbook

The Do s and Don ts of Pressure Transducers

Weight Measurement Technology

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

SEMICONDUCTOR TECHNICAL DATA

Micro Power Generators. Sung Park Kelvin Yuk ECS 203

Surface Profilometry as a tool to Measure Thin Film Stress, A Practical Approach. Gianni Franceschinis, RIT MicroE Graduate Student

Biaxial tripod MEMS mirror and omnidirectional lens for a low cost wide angle laser range sensor

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007

Signal Conditioning Wheatstone Resistive Bridge Sensors

Practical Application of Industrial Fiber Optic Sensing Systems

An equivalent circuit of a loop antenna.

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

Application Note. So You Need to Measure Some Inductors?

Electronic Instrumentation

Varactor Diodes. Introduction. Key Electrical Parameters. Reverse Breakdown Voltage and Reverse Leakage Current APPLICATION NOTE

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

MEASUREMENT SET-UP FOR TRAPS

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

Development of New Inkjet Head Applying MEMS Technology and Thin Film Actuator

Introduction to vacuum gauges. Vacuum Gauges where the Pressure Readings are Independent of the Type of Gas (Mechanical Vacuum Gauges)

AAV003-10E Current Sensor

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

High Voltage Power Supplies for Analytical Instrumentation

METU DEPARTMENT OF METALLURGICAL AND MATERIALS ENGINEERING

Measuring Temperature withthermistors a Tutorial David Potter

MEMS devices application based testing

Application Note for SDP600 and SDP1000 Series Measuring Differential Pressure and Air Volume with Sensirion s CMOSens technology

1.Introduction. Introduction. Most of slides come from Semiconductor Manufacturing Technology by Michael Quirk and Julian Serda.

Application Note 58 Crystal Considerations with Dallas Real Time Clocks

Integrated Silicon Pressure Sensor On-Chip Signal Conditioned, Temperature Compensated and Calibrated

Signal Conditioning Piezoelectric Sensors

NEW MICROWAVE APPLICATIONS FOR THICK FILM THERMISTORS

S-Band Low Noise Amplifier Using the ATF Application Note G004

Op Amp Circuit Collection

Single Transistor FM Transmitter Design

MEMS Processes from CMP

The sensor can be operated at any frequency between DC and 1 MHz.

LM118/LM218/LM318 Operational Amplifiers

9. Force Measurement with a Strain gage Bridge

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Freescale Semiconductor. Integrated Silicon Pressure Sensor. On-Chip Signal Conditioned, Temperature Compensated and Calibrated MPX4080D.

Low Voltage, Resistor Programmable Thermostatic Switch AD22105

International Journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

Models SFP33 & SFP32 Pressure Transmitters

Basic RTD Measurements. Basics of Resistance Temperature Detectors

CHARACTERIZATION OF POLYMERS BY TMA. W.J. Sichina, National Marketing Manager

Objectives. Capacitors 262 CHAPTER 5 ENERGY

Errors Due to Shared Leadwires in Parallel Strain Gage Circuits

Why intelligent machining

FEATURE ARTICLE. Figure 1: Current vs. Forward Voltage Curves for Silicon Schottky Diodes with High, Medium, Low and ZBD Barrier Heights

Unsteady Pressure Measurements

W07 Sensors and Measurement (1/2) Yrd. Doç. Dr. Aytaç Gören

AN_6521_035 APRIL 2009

Pressure Transducer to ADC Application

SMT POWER THERMISTORS

Advantages of Precision Resistance Networks for use in Sensitive Applications

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

LM35 Precision Centigrade Temperature Sensors

Section 2 Kulite Sensing Technology

A wave lab inside a coaxial cable

Mounting instructions. Acceleration Transducer B12. B 26.B12.10 en

DPI 260 SERIES: Digital Pressure Indicators

Fraunhofer ISIT, Itzehoe 14. Juni Fraunhofer Institut Siliziumtechnologie (ISIT)

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

MCE380: Measurements and Instrumentation Lab. Chapter 9: Force, Torque and Strain Measurements

Injection molding equipment

Capacitors in Circuits

Overview. also give you an idea of ANSYS capabilities. In this chapter, we will define Finite Element Analysis and. Topics covered: B.

A Remote Plasma Sputter Process for High Rate Web Coating of Low Temperature Plastic Film with High Quality Thin Film Metals and Insulators

Evaluating AC Current Sensor Options for Power Delivery Systems

New High Current MOSFET Module Offers 177 µω R DS(on)

E/M Experiment: Electrons in a Magnetic Field.

MMIC packaging. 1. Introduction 2. Data interface. Data submittal methods. Data formats. Single chip & MCM solutions. Contents

Technical Information TI/266-EN Rev.B. 2600T Series Pressure Transmitters Basic Transmitter Theory. Engineered solutions for all applications

Freescale Semiconductor. Integrated Silicon Pressure Sensor. On-Chip Signal Conditioned, Temperature Compensated and Calibrated MPX5500.

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

NATIONAL TYPE MB-40SL MULTI-BAND TANK 9/29/1953

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

Bi-directional FlipFET TM MOSFETs for Cell Phone Battery Protection Circuits

CHAPTER 6 THERMAL DESIGN CONSIDERATIONS. page. Introduction 6-2. Thermal resistance 6-2. Junction temperature 6-2. Factors affecting R th(j-a) 6-2

APPLICATION NOTE AP050830

Resistor Theory and Technology

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Trends in Hitachi s MEMS Sensors for Automobiles

MXD7202G/H/M/N. Low Cost, Low Noise ±2 g Dual Axis Accelerometer with Digital Outputs

A Comparison of Trapped Acoustic Technology and Standard Piezo Switching Elements By: Donald Sweeney

How to Improve Tablet PCs and Other Portable Devices with MEMS Timing Technology

Lecture 030 DSM CMOS Technology (3/24/10) Page 030-1

Basic Principle. These trapped energy regions are set into motion with transducers and act as high quality resonators.

Transcription:

Trench Etched Resonant Pressure Sensor: TERPS Russell Craddock & Peter Kinnell GE Measurement & Control Solutions, Fir Tree lane, Groby, UK LE6 0FH INTRODUCTION High precision pressure sensors based on resonating techniques have been manufactured for many years but use large transducer components and often have unwieldy media isolation techniques. This paper presents a MEMS Resonant Pressure Transducer (RPT) that is produced using a flexible fabrication route to allow pressure ranges from 1bar to 700bar in fully oil isolated hermetic packages without compromising sensor performance. The key aspects of the fabrication process and sensor design that make this possible are presented. Data showing long-term stability of better than 100ppm drift per year are presented. This paper discusses a new silicon based transducer design that can be packaged for use in a harsh environment in a small form factor. Existing Pressure sensor technologies Metal devices Strain Gauges Invented in 1938 traditional strain gauge sensors employ the change in resistance of a metal foil or wire as its shape is deformed. In simple terms this is the increase in length of the wire and the corresponding decrease in cross sectional area due to Poissons s ratio. This shape change increases the resistance as electrons are forced to flow further, and are crowded by the decreased cross sectional area. (The opposite is also true- the wire can be compressed creating a decreasing resistance). The change in resistance caused by strain- or Gauge factor is typically around 2. These strain gauges are often bonded onto diaphragms in a Wheatstone bridge arrangement to create pressure sensors. A major disadvantage in these sensors is the limitation in signal due to the material properties of the foil or wire. The material can only be strained until it s elastic limit beyond which a permanent deflection and hence resistance is created. Typically a limit of 3mV per volt of excitation is employed to maintain an acceptable industrial pressure hysteresis of <0.1% full-scale output. Thermal hystersis is also created by the thermal expansion mismatch between the strain gauge material and the diaphragm material.

Brittle and crystal materials Moving away from metal strain gauges to brittle materials avoids the pitfalls of material yield and plastic creep. The materials of choice are typically quartz or silicon with the latter having the advantage of the quality and availability driven by the semiconductor industry. Silicon Piezoresistive Pressure sensors Silicon Piezorestive sensors derive from Smith s (1) discovery of the piezoresistive effect in discrete silicon resistors (Piezoresistance itself was discovered by Lord Kelvin in 1856). Commercial silicon pressure sensors became available in the early 70 s with the GE legacy brand Druck starting production in 1972. Unlike strain gauges piezoresistive gauges do not change their resistance due to the change of shape of the resistors but instead due to the separation of the, normally equal, energy band in the semiconductor, due to the stress created by applied forces. This causes increase in the ratio of high mobility carriers with respect to the low mobility carriers in one axis and consequent decrease in resistivity. A Gauge factor of ~200 is possible ~100x that of simple strain gauges. The advantages of silicon piezoresistive pressure sensors are the high output levels, 20mV/V is typical and the virtual non-existence of pressure hysteresis due to the brittle nature of the silicon crystal. The disadvantages are the requirement to correct the temperature coefficient of the piezoresistive coefficients (~2000ppm/ºC), and the long term drift in the resistors due to, for instance, surface charge effects These drifts create a 0.1%/year drift in a typical commercial sensor although well designed sensors such as GE Druck s Harsh Environment products can have significantly better performance. Silicon Capacitive Pressure Sensors Silicon capacitive pressure sensors rely on measuring the change in deflection of a diaphragm. They have the same advantages of the brittle silicon crystal that piezoresistive sensors have and avoid the issues of resistor stability. Often they are used in absolute devices where the capacitive plates can be maintained in a vacuum. This helps avoids one of the causes of error: change in the dielectric between the capacitor plates. The other difficulty in the technique is the difficulty in measuring the small capacitance changes that are created. These changes can be swamped by the wire-bond interconnects in the assembly and by changes in the detection circuit itself. Despite the difficulties relatively low accuracy silicon capacitive products exist in particular accelerometer devices where deflection can be created with low stresses giving high over-range levels. Higher accuracy products can be created in limited applications for instance benign environment, capacitive absolute barometric sensors exist with stabilities of 0.01%/yr Quartz pressure sensors Quartz Mechanical sensors By relying on the brittle nature of fused quartz a number of interesting mechanical structures can be created. These can be capacitive- similar to silicon devices or more interestingly based on the Bourdon tube principle such as a mechanical pressure gauge. In this latter device a coiled tube of fused quartz is pressurized creating a rotational force as the tube tries to un-roll. This defection can be measured using capacitive or inductive techniques or as the GE legacy brand Ruska the force required to prevent the un-rolling measured. This latter, force feed back technique, gives the Ruska 7250 instrument a precision of 50ppm of reading. The disadvantage of this technique is the size and fragility of the sensor rendering it useful only in precision instruments.

Quartz Resonant Sensors A number of manufacturers produce transducers relying on the piezoelectric effect to drive the quartz sensor into resonance much like a quartz crystal oscillator. Stretching or compressing the resonating structure changes the resonance of the crystal. Either mechanical linkages or quartz diaphragm structures are used to create this force. These true crystal quartz devices can be manufactured to be highly accurate sensors but tend to be bulky devices often requiring significant transducer packaging to contain the mechanical linkages. As with the quartz Bourdon tube they often fragile and used as laboratory instruments although transducers are also marketed. Typically the transducers require significant packing to create a product capable of use in harsh environments. The quartz sensor element is generally large compared with a silicon-based element that has the advantages of batch manufacture and precise microelectronics processing. Silicon Resonant Sensors Similar to crystalline quartz resonating transducers silicon resonant sensors rely on the stretching of a structure to change the frequency of the transducer. Pressure RESONATING STRUCTURE Fig 1 Resonant pressure sensor operation Unlike many of the quartz sensors, silicon resonating pressure sensors employ a crystalline diaphragm structure on-chip. These allow a small silicon device without the need of the complex mechanical linkages used to strain the elements in some quartz devices. Some examples of mature products are those based Yokagawa s Dharp and GE Sensing s RPT MEMs pressure elements. These devices differ on both construction and drive/sensing configuration. The Dharp is manufactured using surface micromachining on a silicon diaphragm creating a double-ended tuning fork configuration inside a vacuum-sealed poly-silicon tunnel. The device is operated as a differential pressure sensor in number of process transmitter products with a quoted stability figure of 0.1%/10 yrs. It is driven to resonance using an external magnetic field and is limited by extremes of temperature and compact packaging- but is well suited for it s application in bulky high line differential pressure process transmitters. GE Druck s RPT has been manufactured for 18years with a stability of 0.01%/year and accuracy of <0.01%Full Scale including temperature effects. Unlike the Yokagawa, device that relies on poly-silicon to create the resonator, the GE Druck RPT is a resonator and diaphragm manufactured with entirely single crystal silicon. The devices is driven in to oscillation electro-statically and sensing by charge output creating a compact structure that can be packaged in a internal diameter <7.5mm.

Fig 2 GE Druck RPT single crystal silicon element. The TERPS Device The RPT has been a very successful product but has a maximum pressure range of 3.5Bar and limited media compatibility. We have been perfecting it s replacement for some years concentrating on flexible manufacture of a MEMS resonating pressure sensor capable of pressure ranges beyond 700Bar with media compatibility as a key consideration. Fig. 3. Photograph of a TERPS die. The resonator has been specifically optimised such that it may be operated in media isolated harsh environment packages. There are two key aspects of the resonator design that allow this. The first is the use of a patented low impedance piezoresistive outputs so the resonator can be operated in a closed loop with reduced influence from parasitic capacitances. The second is the optimised resonator geometry that creates a lateral resonator mode. This mode is designed to be a fully mechanically balanced, which allows high resonator quality factors independent of the pressure media or isolation fluid. Fig 4 Picture of the TERPS structure

The sensor die is hermetically isolated from the pressure media by a metallic isolation diaphragm within a vacuum oil filled chip cavity. The diaphragm structure has been optimized to prevent the thermal expansion of the oil creating thermal hystersis. The die uses three technologies: silicon-on-insulator (SOI) wafers; direct silicon fusion bonding (SFB); and deep reactive ion etching (DRIE) to produce die as shown in Fig 4. These technologies are now commonplace in MEMS facilities and offer well-defined and controlled processes. The key advantages of these techniques are: Well defined resonant: frequency by using SOI to control thickness and mass of resonating structure. Insensitive of media viscosity: by using DRIE to create well defined patent structures for dynamic mass and force balance. Harsh media Isolation: by using DRIE to manufacture complex low impedance sensing technique. Low thermal and pressure hysteresis: by using SFB to assembly single crystal silicon wafers without the use of adhesives, solders or glass frits. Performance The consideration of packaging at the die design stage has allowed the new die to be packaged in isolated hermetic packages with no significant impact on resonator operation and long-term stability. Figs 5 and 6 show curves plotting sensor offset and full scale for a range of die from fully isolated to fully unconstrained. It can be seen that over an 18-month the offset and full scale output shifted by less than 0.01% of full scale. Fig 5 Full scale output stability

Fig 6 Offset stability Equal important to stability is the accuracy of the device. The TERPS device is presently packaged for operation from 54 C to 125 C and over this temperature range the frequency output of the resonator and temperature signal are combined by polynomial curve-fitting to create a performance of better than <0.01% of Full Scale pressure. Fig 6 Curve-fit accuracy

Conclusion GE created a new range of media isolated pressure sensors capable of achieving 0.01% Full-scale accuracy and 0.01%/year stability.