Light Fittings for Fluorescent Lamps Series EXLUX 6001

Similar documents
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire with LED Series EXLUX 6402/2

Terminal Boxes Series 8146

Plug and Socket Devices CES 63 A Series 8579

Control and Distribution Boxes made of Stainless Steel Series 8150

Plug and Socket Devices SolConeX 16 A Series 8570

Series 8146/5-V37 and Series 8150/5-V37

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Flameproof Audible Signal 115 db (A) Series YA90

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Floodlight Range Installation Guide

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Control Stations Made of Polyester Resin Series 8146

A good connection. International approvals.

Compact pressure switch Flameproof enclosure Ex d Model PCA

Operating Instructions

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

H45 LED - Direct and indirect pendant

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Abtech Custom Solutions

Solenoid Valve Island Type 3965

Product and functional description

Explosion proof enclosures

Control Stations in Sheet steel or Stainless Steel Series 8125

HERZ-Thermal Actuators

Technical Data. Dimensions

Emergency Light Fittings

e explosion-proof emergency light fittings battery sets for zone 1/21 and zone 2/22 e 187/ nd 187/188...

Technical data sheet TDS0070

Technical Data. Dimensions

Operating Instructions

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Fluxa Area floodlights for high pressure discharge lamps and LEDs

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

8146/5 Series Breaker Panelboards

Invue ECM/EMM EPIC MEDIUM W

7 Lighting Technology

Inductive sensor NI10-M18-Y1X-H1141

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Terminal Box. Specifications TNCN

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Cable Plug acc. to DIN EN , Form A

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Vario-Series Accessories

Digital inductive conductivity transmitter

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Acclaim III Recessed Fluorescent Luminaires ATEX

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

DuroSite TM High Bay Lighting

Nightscape High performance floodlights and spotlights for discharge lamps

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Instructions for Safe Use

ASSEMBLED SOCKET-COMBINATIONS

CUSTOMS UNION. CUSTOMS UNION CERTIFICATE OF CONFORMANCE No. RU C-DE.ГБ05.В Series RU No

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Software and Display instruments

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Electric Rotary Actuator - On/Off or programmable control actuator

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

Technical Specifications

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

TEIP11 I/P signal converter for standard signals. Measurement made easy

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

Technical Information RIA14

Nightspot A2 Floodlights for LEDs and high pressure discharge lamps

SITRANS F flowmeters SITRANS F M

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

Wolflite Safety Handlamp H-251E

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Capacitive Prox E2K-X

9 Control Equipment. Control Button Series 8082

Flow switches Series AD/VH

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Guide to enclosures for potentially explosive atmospheres

How To Build A Low Voltage Capacitor Lvcp

Transcription:

> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened www.stahl.de 15454E00 The lights of the can be used for normal lighting but also for an emergency light which is supplied with current via a group or a central system. ATEX / IECEx / GOST Zone 0 1 2 20 21 22 For use in: x x x x WebCode 6001A Lighting /1

Selection Table Design Length Lamp wattage Number of lamps Order number Weight mm W kg EXLUX 6001 700 18 2 6001/522-9510-1511 8.500 1310 36 2 6001/542-9510-1511 10.400 1610 58 2 6001/562-9510-1511 10.800 Order Number Supplement Through wiring without 6001/5..-.0..-... with 5 conductors 6001/5..-.5..-... ECG 220... 240 V 1xDC 6001/5..-...0-... 220... 240 V 2xDC 6001/5..-...1-... 110... 240 V 1xDC (only 18 W and 36 W) 6001/5..-...2-... 110... 240 V 2xDC (only 18 W and 36 W) 6001/5..-...3-... 120... 277 V 2xDC (17 W, 32 W and 40 W NEC-standard) 6001/5..-...6-... Connection terminal Cage clamp terminal type WAGO 0.5... 4 mm 2 6001/5..-...-1... Screw-type terminal type STAHL 1.5... 6 mm 2 6001/5..-...-2... Cable glands Standard 1 x M25 x 1.5 cable gland and 6001/5..-...-..1. 2 x M25 x 1.5 stopping plugs Special 1 x M20 x 1,5 cable gland and 2 x M20 x 1,5 stopping plug 6001/5..-...-..2. Note The lights are delivered without fluorescent lamps and assembly parts. These parts must be ordered separately! Explosion protection Global (IECEx) Gas and dust IECEx PTB 13.0003 Ex d e IIC T4 Gb or Ex db eb IIC T4 Ex tb IIIC T80 C Db or Ex tb IIIC T80 C Europe (ATEX) Gas and dust PTB 13 ATEX 2004 E II 2 G Ex d e IIC T4 Gb or Ex db eb IIC T4 Approvals and Certificates Certificates E II 2 D Ex tb IIIC T80 C Db or Ex tb IIIC T80 C IECEx, ATEX Technical data Electrical data Ballast 6001/...-...0-... 6001/...-...1-... Lamp start Cold start Cold start Voltage 220... 240 V AC 220... 240 V AC Voltage DC during 198 264 V DC 104 264 V DC switching on Voltage DC during 176 264 V DC 198 264 V DC operation Frequency 0 / 50 60 Hz 0 / 50 60 Hz Operation of the 1 lamp 2 lamps lamps DC Lamp standard IEC 60081 IEC 60081 Lamp power 18, 36, 58 W 18, 36, 58 W Nominal current 1 x 18 W, 85 ma 2 x 18 W, 170 ma 1 x 36 W, 160 ma 2 x 36 W, 320 ma 1 x 58 W, 250 ma 2 x 58 W, 500 ma 1 x 18 W, 85 ma 2 x 18 W, 170 ma 1 x 36 W, 160 ma 2 x 36 W, 320 ma 1 x 58 W, 250 ma 2 x 58 W, 500 ma /2 Lighting

Technical data Electrical data Ballast Power factor cos p cos p ) 0.97 capacitive; no additional compensation required Disconnection of the light When opening the light Switch with safety lock; when opening the central lock, all poles of the voltage supply to the ballast are disconnected; contacts of the switching element are NC contacts, they can only be switched on again when the lamp cover and the central locking system are closed. In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power supply. End of life switch The electronic ballast, type 6042/9..-. fulfills the requirements according to IEC 61347-2-3 (simulation of the "end of life effect" of fluorescent lamps, "asymmetric pulse test 1" and "asymmetric power test 2" correspond to the test conditions in the draft IEC 60079-7 ed.4 appendix H). Luminous Characteristics Measures for light guidance 6001/...-...2-... 6001/...-...3-... 6001/...-...6-... Lamp start Cold start Cold start Cold start Voltage 110... 240 V AC 110... 240 V AC 120... 277 V AC Voltage DC during 104 264 V DC 104 264 V DC 113 294 V DC switching on Voltage DC during 104 264 V DC 104 264 V DC 113 294 V DC operation Frequency 0 / 50 60 Hz 0 / 50 60 Hz 0 / 50 60 Hz Operation of the 1 lamp 2 lamps 2 lamps lamps DC Lamp standard IEC 60081 IEC 60081 ANSI C78.81 Lamp power 18, 36 W 18, 36 W 17, 32, 40 W Nominal current 1 x 18 W, 85... 175 ma 2 x 18 W, 170... 345 ma 1 x 36 W, 155... 330 ma 2 x 36 W, 310... 660 ma 1 x 18 W, 85... 175 ma 2 x 18 W, 170... 345 ma 1 x 36 W, 155... 330 ma 2 x 36 W, 310... 660 ma 1 x 17 W, 80 155 ma 2 x 17 W, 160 305 ma 1 x 32 W, 135 285 ma 2 x 32 W, 270 570 ma 1 x 40 W, 160 360 ma 2 x 40 W, 325 715 ma Standard: Deep bowl, reflector of the lamp is white Lateral dazzle limitation in the lamp cover Ambient conditions Operating temperature Through wiring range Type without with 6001/52.-...0-... -30 C... 60 C -30 C... 50 C 6001/52.-...1-... -30 C... 60 C -30 C... 50 C 6001/52.-...2-... -30 C... 45 C -30 C... 40 C 6001/52.-...3-... -30 C... 45 C -30 C... 40 C 6001/54.-...0-... -30 C... 55 C -30 C... 50 C 6001/54.-...1-... -30 C... 55 C -30 C... 50 C 6001/54.-...2-... -30 C... 45 C -30 C... 40 C 6001/54.-...3-... -30 C... 45 C -30 C... 40 C 6001/56.-...0-... -20 C... 55 C -20 C... 50 C 6001/56.-...1-... -20 C... 55 C -20 C... 50 C 6001/53.-...6-... -30 C... 40 C -30 C... 40 C 6001/55.-...6-... -30 C... 40 C -30 C... 40 C The lowest ambient temperature when used with breather is -20 C. Mechanical data Degree of protection IP66 (IEC 60589) Protection class Material Enclosure Enclosure I(with internal PE connection) Polyester resin, glass fibre-reinforced Colour white, similar to RAL 9010 Colour colour grey, similar to RAL 7035 Gasket Silicone foam gasket in the lamp cover Lamp cover Polycarbonate Lamp locking Central locking which can be opened/closed using a socket key M8 / wrench size 13, hinged lamp cover Lighting /3

Technical data Mounting / Installation Cable glands Connection Through wiring Assembly Standard luminaire Plastic: 1 x M25 x 1.5 cable gland 8161 and 2 x M25 x 1.5 stopping plugs 8290 (enclosed) Metal: 2 x metal plates M20 x 1.5 connected by means of PE for metal cable entries Attention: cable entries must be ordered separately Special: max. 4 bores for M20, M25, NPT ½ max. 2 bores for NPT ¾ Metal cable glands: M20 x 1.5, M25 x 1.5; earthing of the metal cable entries by means of metal plates Standard: Sonder: Through wiring without Käfigzugfederklemmen 5-polig: L1, L2, L3, N, PE Klemmbereich: 1 x 0,75... 4 mm 2 (eindrähtig / feindrähtig) (2 freie Klemmstellen je Pol vorhanden) Klemmenblock mit Abdeckung 5-polig: L1, L2, L3, N, PE Klemmbereich: 2 x 1,5... 6 mm 2 (eindrähtig); 2 x 1,5... 4 mm 2 (feindrähtig) Standard luminaire Luminaires are equipped with internal through wiring. Ingoing and outgoing leads can be connected on the opposite sides. Terminals: see Techn. data Wiring cross-section: 2.5 mm 2 for max. 16 A Optional On the connection side, there are 2 bores M25 x 1.5 for cable entries for ingoing and outgoing wiring of the connection line (ingoing and outgoing leads on one side). For outdoor mounting, a breather is recommended Standard luminaire Standard: 2 x M8 insert nuts in the enclosure Special: Mounting grooves in the enclosure for the use of fastening and ceiling rails for variable luminaire mounting (variable mounting distances for luminaires 18 W: 320... 480 mm; 36 W / 58 W: 670... 930 mm) Accessories and Spare Parts Designation Figure Description Art. no. Weight Fluorescent lamps 04936E00 Two-pin cap d 26 mm Light colour: universal white 18 W 1350 Im kg 108952 0.100 36 W 3350 Im 58 W 5200 Im 108951 0.200 108950 0.220 Lamp cover for luminaire L=700 222427 0.639 for luminaire L=1310 222428 1.149 for luminaire L=1610 222429 1.450 Lamp-holder Lamp holder G13 1 piece 117252 0.025 Switch 05696E00 Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.025 10809E00 /4 Lighting

Accessories and Spare Parts Designation Figure Description Art. no. Weight Socket key M8 / wrench size 13; to open/close the central locking kg 222430 0.210 Adapter plates 15507E00 for use together with metal cable glands; the metal cable glands are integrated in the earthing system via adapter plates 05755E00 1 x M20 x 1.5 1 piece 115815 0.070 1 x M25 x 1.5 1 piece 115818 0.070 2 x M20 x 1.5 1 piece 115826 0.060 2 x M25 x 1.5 1 piece 1 x NPT 1 / 2 1 piece 115828 0.060 115821 0.070 1 x NPT 3 / 4 1 piece 115824 0.070 Mounting rail 2 x NPT 1 / 2 1 piece for a variable mounting distance 1 pair 115829 0.060 222826 0.300 Mounting bracket 15584E00 Mounting clamp mounted on a mounting rail for a variable mounting distance; 1 pair 222456 0.400 Ceiling and wallmounting bracket Pipe clamp 15585E00 15586E00 mounted on a mounting rail for a variable mounting distance; Material: stainless steel Lamp can be swiveled in steps of 15 1 pair 222827 2.400 with mounting rail for a variable mounting distance; Material: stainless steel 1 pair 15583E00 R 1 1 / 4 222458 1.250 R 1 1 / 2 222459 1.200 R 2 222460 1.300 Bracket for wall mounting with tube for side entry lamp; with tube, length 400 mm, d 42 mm 108947 2.480 05460E00 Ring bolt M8, direct mounting in insert nuts, 1 pair 115736 0.120 05378E00 Breathing gland M25 x 1.5 in order to avoid condensate formation 115738 0.020 05703E00 Lighting /5

Accessories and Spare Parts Designation Figure Description Art. no. Weight kg Ballast Spare ballast for replacement 1:1 6042/923-21; 18 W; 220... 240 V; 1xDC 117594 1.460 15587E00 6042/923-22; 18 W; 220... 240 V; 2xDC 117593 1.400 6042/943-21; 36 W; 220... 240 V; 1xDC 117596 1.400 6042/943-22; 36 W; 220... 240 V; 2xDC 117595 1.400 6042/963-21; 58 W; 220... 240 V; 1xDC 117597 1.450 6042/963-22; 58 W; 220... 240 V; 2xDC 117598 1.400 6042/913-22; 18 W; 110... 240 V; 2xDC 202164 1.550 6042/983-22; 36 W; 110... 240 V; 2xDC 202165 1.550 Dimension Drawings (All Dimension in mm [Inch]) - Subject to Alternations b L1 L2 M25 x 1,5 L3 M25 x 1,5 h1 15440E00 Dimension Light 17/18 W 32/36 W 40/58 W L1 700 [27,56] 1310 [51,57] 1610 [63,39] L2 1) 400 [15,75] 800 [31,50] 800 [31,50] L3 2) 320... 480 [12,60... 18,90] 670... 930 [26,38... 36,61] 670... 930 [26,38... 36,61 b 184 [7,24] 184 [7,24] 184 [7,24] h1 125 [4,92] 125 [4,92] 125 [4,92] 1) fixed mounting distance 2) variable mounting distance EXLUX 6001 Standard Light /6 Lighting

Dimension Drawings for Assembly Parts and Accessories (All dimensions in mm [Inch]) - Subject to Alternations 12 [ 0, 47 ] 30,50 [ 1, 20 ] 30 [1,18]. 9 [0,35] 215 [ 8.46] 193-198 [7,60-7,80] 124 [ 4, 88] 11 [ 0, 43] 86 [ 3, 39] 74 [ 2, 91] 32 [1,26] 6,10 [0,24] ø 6,10 ø 8,10 9 [ø. 0, 24] [ø 0,32] [0,35] 18,50 [ 0, 73 ] 13 [0,51] 215 [ 8, 46] 193-198 [7,60. - 7,80]. 143 [5,63] 15778E00 15779E00 Mounting rail ø 20 [ø 0,79] 162 [6,38] Ring bolt fitted in the insert nuts of the light 24 [0,95] 172 [6,77] 15782E00 15781E00 15783E00 Mounting bracket fitted in the mounting rail ø 42 [ø 1 1/4] ø 48 [ø 1 1/2] ø 60 [ø 2] 180,50 [1 1/4] 187,50 [1 1/2] 200,50 [2] Pipe clamp fitted in the mounting rail 10x15 A 296 [11,65] 42 [ 1,65] ø 10,50 [ ø 0,41] 15 400 [15,75] A [1,39] 34 65,50-74,50 [2,58-2,93] 110 [4,33] 8,50 [0,35] 8,50 [0,35] 15780E00 Wall mounting bracket fitted in the mounting rail 198 [7,80] 160 [6,30] 120 [4,72] 143 [5,63] 104 [4,09] 90 130 [5,12] 220 [8,66] SW 5 20 [0,79] 180 [7,09] Bracket for wall mounting with pipe section 03257E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Lighting /7