NEW!! OxyProbe II. Manufacturers of Sensors, Bioreactors and Process Control Automation. D500 and D600 Series

Similar documents
Stainless Steel Dissolved Oxygen Electrodes

Dissolved Oxygen Sensors

DISSOLVED OXYGEN PROBE

Trace Dissolved Oxygen Sensor

Toroidal Conductivity Sensor

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Milwaukee USER MANUAL

Stainless steel process fittings

RTD Temperature Probe for the Food/Pharmaceutical Industry

General Purpose ph/orp Sensors

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Galvanic Parts Per Million Dissolved Oxygen Systems

For additional information, please visit our website at

Typical Aluminum GFM Mass Flow Meter

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

Vacuum drying oven for non-flammable solvents

Submersion/Insertion Toroidal Sensor

Compact ph Measuring Instruments

Incubator with mechanical convection

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Digital inductive conductivity transmitter

Test equipment for temperature and its reduction

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

The Do s and Don ts of Pressure Transducers

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

User Guide Dissolved Oxygen Probes

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

TB2CS Conductivity sensor 2-Electrode. Superior accuracy in low level conductivity measurement ranges

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

VISIFERM DO. Optical Oxygen Sensors with Integrated Transmitter THE MEASURE OF EXCELLENCE

Quick Connect. RTDs, Cordsets and Transmitter with M12 Connections

Discover Configurable BioProcessing Solutions

Introducing: BioXpert. Supervisory Control and Data Acquisition Software

Robot Welding Torch System

Low Frequency Velocity Sensor

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Material test chamber with mechanical convection

Heating oven with mechanical convection

Features. Picture. Specifications

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

Conductive Level Switch FK 2 Technical Data:

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Heating oven with mechanical control

Kit Highlights and Key Features

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Uncompromising Customer Service. Baumann TM Sanitary and Aseptic Process Valves

psens Pressure Measurement

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Relative and absolute pressure switch type 529

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Key Features. Product Overview. Threaded Joint Rate Simulator

08. SEK IDC CONNECTORS

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Baumann Flexsleev Sanitary Control Valve

Subminiature Load Cell Model 8417

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

Datalogger DL/N 70 Version:

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Pressure transmitter For general industrial applications Model A-10

Lenntech Tel Fax

Section: R100 Bulletin: R Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

ExStik TM ph Waterproof Meters

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

How to measure absolute pressure using piezoresistive sensing elements

Hydraulic Control Solutions

SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration

PS-SEAL PTFE based high performance seal

Models SFP33 & SFP32 Pressure Transmitters

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

Electronic Pressure Monitoring New Products

Innovative Vacuum for Automation. Vacuum Components Modular System for Vacuum End Effectors VEE

Operator Quick Guide EC SENSOR

PAT Tester Printers and Barcode Scanners

Electronic Pressure Switch EDS 300

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Digital input modules

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

ArtisanLink Staining System is an automated special stains slide

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

LED...A Q Series Sealed High-Intensity

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

A99B Series Temperature Sensors

Mass Flow Meters & Controllers

Portable digital microprocessor thermometers with interchangeable probes

Transcription:

NEW!! Manufacturers of Sensors, Bioreactors and Process Control Automation NEW!! OxyProbe II D500 and D600 Series Dissolved Oxygen Sensors for Biotech Applications

Better Performance! Modular Construction Laser Etched Identification and Serial Number Universal Pg13.5 Threads Choice of Industry Standard 4-Pin Connector or VarioPin Our standard D9 connector has hermetically sealed gold-plated contacts in a glass insulator that offers the ultimate in signal isolation and transmission. For customers with installed VarioPin cable systems we also offer the VP connector as a standard option on all of our designs. Hygienic Sensor Design: Microrganisms cannot adhere to the sensor surface due to the enhanced finish (N5/Ra15µ in Quality). The sensor is fully sterilizable and autoclavable. Time-Saving Maintenance: Membrane body and sensor inner body can be changed out very quickly. A simple membrane body replacement takes just two minutes and can be made on site by the user. Due to the modular design, the different sensors have basically the same spare parts. This minimizes inventory stocking requirements. Features Overview: Autoclavable and steam sterilizable. Accurate measurement and quick response. Long lasting and easy to maintain membranes. FDA positive listed materials of construction. Hygienically polished N5 surface finish (Max. Ra15µ in). Wetted O-rings comply with FDA and USP Class VI standards. Other Highlights: Comes with either waterproof VarioPin or D9 connector. T-Pull connector versions allow for easy removal from fermenter and reduces strain on cable. Variety of sensor lengths available. Electropolished Stainless Steel Surfaces This provides better surface cleanability than mechanically polished Ra15µ in alternatives. Copies of 3.1 certificates and mill certificates are available on request. Every sensor is serialized with paperwork on file in our database. The Second Generation of the OxyProbe incorporates an improved membrane design, increased signal stability, easier assembly, and enhanced regulatory documentation. p.2 www.broadleyjames.co.uk tel: +44 (0) 1525 862518 sales@broadleyjames.co.uk

Documented Materials! Parts/Components Material Certs. Compiled into: USP Class VI Wetted Materials of Construction Each membrane has a lot number traceable back to the principal components. All wetted materials conform to USP Class VI specifications. All lot numbers and serial numbers are stored in our database linking them to the primary materials of construction, and in turn, the various MSDS, Heats, Material Certs, Animal Derived Materials statements, etc. Steel Teflon O-Ring Animal Derived Materials Heat # Certificate R a Finish Certificate Electropolish Certificate Animal Derived Materials USP Class VI Certificate Animal Derived Materials USP Class VI Certificate 3.1 and C.O.C. Documents and Quality Certs. Broadley-James Document Summary of Certificates. All OxyProbe II sensors and membranes come with complete traceability of all wetted materials, including o-rings, membrane material and steel. Easier To Use! A lot number is laser-engraved on each individual membrane, and each sensor has a unique serial number. Replaceable Anode/Cathode Assembly A concept pioneered by Broadley-James, this unique assembly permits the sensor to be repaired quickly and reliably. Send your sensors to us for rebuild and save about half the price of purchasing a complete new sensor assembly! Membrane Cartridge Filling is easy with the self-adjusting reservoir. No need to measure and no risk of overfilling. Just fill the membrane to the top and insert onto the cathode. Cap Sleeve New OxyProbe II This new design is tip-tolerant and allows for the sensors to be held horizontal or set on a desk or workbench with no need to worry about the electrolyte shifting away from the cathode tip. Rugged 3-Ply Membrane Material The outer silicone layer protects the inner Teflon layer, and an added steel mesh provides the mechanical strength required to withstand repeated autoclaving or steam sterilization. The strongest, most robust membrane in the industry, it is an improvement of the industry standard design. www.broadleyjames.co.uk tel: +44 (0) 1525 862518 sales@broadleyjames.co.uk p.3

Sensor Selection: Size SENSOR SELECTION FOR BIOREACTOR VESSELS A typical benchtop application is less than 20 L and uses a glass vessel with steel headplate. Usually the entire vessel can be placed or wheeled into an autoclave for sterilization prior to a run. Not only is there a range of different vessel sizes used in benchtop bioprocess applications, but also the volume of the media in the vessel will often change during the process. Accordingly, the sensors for benchtop vessels are available in a wide variety of lengths. The operator must choose a sensor length that ensures the sensor tip is submerged at all times during operation. Some sensor models have been configured to thread directly into the headplate and various access ports found on small vessels. Detachable cables and other design features allow these products to withstand the demands of autoclaving requirements. VESSEL SIZE (Total Volume) SENSOR LENGTH 2, 3 and 5 L ph = 225 mm DO = 220 mm 7-10 L ph = 325 mm ph DO = 320 mm 15-20 L ph = 420 mm DO = 420 mm EXAMPLE: 7 L vessel uses 325 mm long sensor Our new OxyProbe II Dissolved Oxygen Sensors Will Work With Your Existing Electronics. Our sensors are compatible with the following equipment/manufacturers using the cables below: Mettler-Toledo Rosemount Knick Sartorius B. Braun Applikon DasGip New Brunswick Scientific Infors VarioPin type and more... Questions? For More Information On Our Cables Call Our Tech Support: Phone: +44 (0) 1525 862518 Fax: +44 (0) 1525 862811 (FF) (L6) (G3) sales@broadleyjames.co.uk p.4 www.broadleyjames.co.uk tel: +44 (0) 1525 862518 sales@broadleyjames.co.uk

Ordering Information Small diameter sensors for use in benchtop bioreactors, or single-use systems, like Hyclone and Xcellerex 12 mm Pg13.5 VARIOPIN D9 STYLE LENGTH PART NUMBER PART NUMBER 12 mm Sensor Order Number Straight T-Pull 120 mm 220 mm 320 mm 420 mm 120 mm 220 mm 320 mm 420 mm D540-B120-PT-VP D540-B220-PT-VP D540-B320-PT-VP D540-B420-PT-VP D545-B120-PT-VP D545-B220-PT-VP D545-B320-PT-VP D545-B420-PT-VP D540-B120-PT-D9 D540-B220-PT-D9 D540-B320-PT-D9 D540-B420-PT-D9 D545-B120-PT-D9 D545-B220-PT-D9 D545-B320-PT-D9 D545-B420-PT-D9 25 mm sensors for use in SIP vessels, from 20 L to 20,000 L 25 mm VARIOPIN D9 STYLE LENGTH PART NUMBER PART NUMBER 25 mm Sensor Order Number Straight T-Pull 80 mm 160 mm 80 mm 160 mm D600-B080-PT-VP D600-B160-PT-VP D605-B080-PT-VP D605-B160-PT-VP D600-B080-PT-D9 D600-B160-PT-D9 D605-B080-PT-D9 D605-B160-PT-D9 B. Braun (Sartorius) 100 mm D630-B100-PT-VP D635-B100-PT-VP D630-B100-PT-D9 D635-B100-PT-D9 www.broadleyjames.co.uk tel: +44 (0) 1525 862518 sales@broadleyjames.co.uk p.5

Accessories Single Cartridge Kit (MK29-01) This kit includes everything required to replace the membrane cartridge and internal o-rings on one 12 mm OxyProbe II. Four Cartridge Kit (MK29-04) This kit contains everything required to replace four membrane cartridges on a 12 mm OxyProbe II, packaged in one box for easy storage. 16 Piece Cartridge Kit (MS29-16) This convenient bulk pack is the most popular among large volume users. It contains 16 membrane cartridges in one easy-to-store box. Internal o-rings, gaskets and electrolyte must be ordered separately. MK29-01 1-pack MK29-04 4-pack MS29-16 16-pcs REPLACEMENT CAP SLEEVE (Steel Casing) AM-9657-S (Standard) AM-9657-G (Guarded) DISSOLVED OXYGEN ELECTROLYTE SOLUTION AS-3140-C30-0250 (250 ml) AS-3140-C30-0025 (25 ml) In critical biotech applications the electrolyte should be changed after every run to yield best results. The shelf life of this solution is approximately 2 years. Lot numbers and expiration dates are clearly marked on each bottle for tracking purposes. BATTERY POWERED POLARIZERS: DO sensors may need to be polarized for several hours prior to calibration and use. Polarization modules allow this to be done without the need for a transmitter. STANDARD POLARIZER (Part Number AM-9221) This battery operated module attaches directly to any OxyProbe. It uses a lithium battery, with a five year life span, which should be checked annually. This polarization module allows maximum portability of a polarized sensor. SMART POLARIZER (Part Number AM-9660) When the dissolved oxygen sensor is connected to the Smart Polariser a polarising voltage is automatically applied to the sensor. The unit displays the raw na output from the sensor, the temperature from the sensor s internal temperature compensator and the unit s battery voltage. This allows the user to test the dissolved oxygen sensor raw output (na) in air (100%) and in zero oxygen conditions (0%). p.6 www.broadleyjames.co.uk tel: +44 (0) 1525 862518 sales@broadleyjames.co.uk

Specifications OxyProbe II PERFORMANCE SPECIFICATIONS Operating Range: 0-300% Saturation Accuracy: < + [1%] Response Time at 25 C: 98% of final value in <60 seconds Sensor Signal in Air 25 C: 40 to 80 na Residual Signal in Oxygen-Free Medium: < 0.1% of the signal in ambient air Maximum Flow Error: < 3% of Total Reading CONSTRUCTION Measuring Principle: Electrochemical - Polarographic Cable Connection: VarioPin or D9 (T82) Connector Design: Straight or Angled (T-Pull) Sensor Body: 316L Stainless Steel Membrane Material: Silicone/Teflon (Reinforced with Steel Mesh) Surface Roughness of Wetted Parts: Max. Ra15µ in (N5) O-Ring Wetted Material: Silicone, EPDM (FDA and USP Class VI positive listed) Sensor Diameter: 12 mm and 25 mm WORKING CONDITIONS Temperature Compensation: Automatic Measuring Temperature Range: 0 to 80 C Environmental Temperature Range: -5 to 135 C (sterilizable and autoclavable) Measuring Pressure Resistance: 0.2 to 6 bar (2.9 to 87 psi absolute) Mechanical Pressure Resistance: Maximum 12 bar (174 psi absolute) CERTIFICATES: FDA approved materials USP Class VI Material Certificate 3.1 Surface Finish Certificate Electropolish C.O.C. (Certificate of Compliance) Quality (Final Inspection Cert.) If you use 12 mm Dissolved Oxygen sensors in your cell culture or fermentation process you are going to want to try the new OxyProbe II design soon. It greatly improves on the existing 12 mm style, offering increased stability, fast response, durability, and ease-of-use. www.broadleyjames.co.uk tel: +44 (0) 1525 862518 sales@broadleyjames.co.uk p.7

Overview: The New OxyProbe II At Broadley-James we all know how important your cell culture or fermentation process is to the success and profitability of your company. We strive to make the best quality products available, while incorporating the best technology and, where possible, greatest cost savings. It s not that often that we have a distinctive new design, as the existing ones meet most the above criteria. However, after several years of refinement we are introducing our latest set of improvements all bundled up in one new sensor, the OxyProbe II. As always, Broadley-James Corporation strives to keep our products backwards compatible. In this case, any of our existing 12 mm OxyProbe sensors can be updated to the OxyProbe II design during the rebuilding process. We can install a new OxyProbe II cathode assembly and will laseretch the Roman numeral II on the sensor body so you will know which type of membrane to use. Over time, you will have all of your existing sensors updated without having to purchase any new ones! The new membrane design is modeled after our successful 25 mm membrane cartridge. It has an expandable inner Silicone bladder that holds the electrolyte within a 316L stainless steel cage. During SIP processes or during autoclaving the electrolyte turns to steam, but does not distend the measurement membrane because the internal bladder expands first, taking the pressure off the sensitive measurement area. This allows us to have a maximum of electrolyte present, with minimum risk of damage to the sensor. The new membrane cartridge design is easy to use and durable enough to be used many times over if necessary. Manufacturers of Sensors, Bioreactors and Process Control Automation Wrest Park, Silsoe Beds MK45 4HS United Kingdom www.broadleyjames.co.uk Phone: +44 (0) 1525 862518 Fax: +44 (0) 1525 862811 sales@broadleyjames.co.uk Broadley-James Ltd., OxyProbe and FermProbe are registered trademarks of Broadley-James Corporation Xcellerex is a registered trademark of Xcellerex, Inc Hyclone is a registered trademark of Thermo Fisher Scientific