Pump-Transfer Cooler Filtration Unit UKF

Similar documents
RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Fixed displacement vane pumps

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Series TMM Axial Piston Motor. Technical Information

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

Radial piston pumps type R and RG

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

Components, Systems and Service for Municipal Machines.

Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + Water removal

Particle Measurement Technology in Practice. From Theory to Application.

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

Filter Elements E /05.06

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

PUMP AND MOTOR DIVISION

The Professional Choice. LDC With DC motor. OLAER LDC optimized for mobile use

Variable Displacement Pump AA10VSO

15/40/80CN Series Medium Pressure Filters

Breathers and Filler Breathers.

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Automatic Back-Flushing Filter AutoFilt RF9.

Hydraulic Control Solutions

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump


MANTA Piston Distributor for Oil and Fluid Grease

Internal gear pump PGF Series 2X and 3X

Refrigeration Compressed Air Dryer Buran Ultrapulse

Rotary screw compressors kw 5,5 7, , bar MODULO

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Unit 24: Applications of Pneumatics and Hydraulics

2/2 and 3/2 Way Size 6 Seat Valves

ECOCIAT. Domestic hot water heat recovery unit

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Pressure Relief Valves SPV, SPVF

Product catalogue, pipe and sewer cleaning systems

Duplex Filters 40/160 LD /160 LDN Industrial Filters Accumulators. Filters for inline installation for continuous operation

912. The engine for construction equipment.

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Unit 24: Applications of Pneumatics and Hydraulics

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

Unit 24: Applications of Pneumatics and Hydraulics

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

NORMAN FILTER COMPANY PRODUCT OVERVIEW

ThermoStar Refrigeration Air Dryers

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Specifications for Volkswagen Industrial Engine

Return line filters. Return line filters

Hydraulic Troubleshooting PRESENTED BY

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

COUNTERBALANCE VALVES

Thermostatic valve Type AVTA

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

PVS Series - Models 185, 600, 1200, 1800 and 2700

Single- and Multi-circuit Pumps

Pressure relief valves Size 6

Reusable contamination basket prevents loss of retained contaminants into the reservoir during element replacement.

Atlas Copco Stationary air compressors

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

ThermoSorb Desiccant Dryers

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Series PVP Variable Volume Piston Pumps

Hydraulic control unit series

Duplex Filters 40 FLDK 0008(C)-0120(C)

Energy Recovery Device isave 21-40

Quiz On Information Learned From Chapter 1

Chapter 5: Flow Valves

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Rules for Classification and Construction Additional Rules and Guidelines

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Conlift1, Conlift2, Conlift2 ph+

ETC -SV. Class 0 oil-free compressed air through catalysis

WANJET. Sprayers. Wanjet sprayers has been produced since 1978.

Rickmeier Solutions. Gear pumps for superior Lubrication

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Compact Air Solutions C Series kw Screw Compressors Want a 5. year warranty? Ask for details!

Machine nozzle with needle shut-off type HP pneumatically or hydraulically controlled

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY /UK March 2004

Longer lifetime for hydraulic oil

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Flow divider (flow distributor), type TQ

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Transcription:

Pump-Transfer Cooler Filtration Unit UKF Symbol General The UKF unit is a compact, easy-to-install system for offline filtration cooling circuits. It consists of a low-noise feed pump, a filter and a plate heat exchanger. Product features Continuous cooling and offline filtration extend the service life of the oil and of the hydraulic system. The offline unit ensures constant oil temperature regardless of the cycle times of the hydraulic systems. Furthermore, consistent flow rates prevent pressure spikes in the heat exchanger. Area of application l Plastic injection moulding machines l Pressing / Stamping l Machining centres l Hydraulic systems l Gears Operating data General Ambient temperature +10 C to +40 C Volumetric efficiency >90 % at ν = 40 mm²/s Mounting position UKF-1: Optional, but easier to maintain if filter below pump UKF-2 / UKF-3: vertical Noise levels UKF-1: <64 db(a) at 1,500 1/min UKF-2 / UKF-3: Pump [cm3/rev] 1 bar 6 bar 15 61 61 20 61 61 30 61 62 40 62 63 50 64 66 70 67 68 100 68 70 130 70 72 (Test medium: ISO VG46 at +40 C) The noise levels are only a guide as the acoustic properties of a room, connections, viscosity and reflections have an effect on the noise level. Pump Suction pressure across max. -0.4 bar to 0.5 bar the suction connection Operating pressure (oil side) max. 6 bar Medium (oil side) Mineral oil to D 51524 Part 1 and Part 2 Temperature range (oil side) +10 C to +80 C Permissible contamination NAS12 or ISO4406: 22/21/18 (oil side) Max. viscosity see viscosity-temperature graph Drive Motor Three-phase electric motor Insulation class: F Protection class: IP55 Speed 1,500 / 1,800 1/min (50/60 Hz) Heat exchanger Heat exchanger connections: Female thread (max. tightening torque 160 Nm) The pipes must be connected so that the connections are stress-free. Linear expansion and vibrations from the pipes to the heat exchanger must be avoided. Medium (water side): l Water glycol (HFC) l Water l s Temperature range (water side) +5 C to +60 C Operating pressure (water side): max. 30 bar Permissible contamination (water side) Water quality The level of particles in suspension should be less than 10 mg/l. Particle size <0.6 mm (spherical) Thread-like particles cause a rapid increase in pressure losses. The following ions are not corrosive under normal conditions: phosphate, nitrate, nitrite, manganese, sodium and potassium also see table on water quality 1

Design There are different versions possible depending on the requirements: UF Feed pump with filter UK Feed pump with plate heat exchanger UKF Feed pump with filter and plate heat exchanger Offline unit consisting of: l Low-noise feed pump l Filter l -water plate heat exchanger l The circuit is fitted with check valves to isolate the filter when used with a positive head tank when changing the filter element UKF-1 Flow rate: Motor rating: Cooling capacity*: 5 15 l/min 0.37 0.55 kw up to 10 kw UKF-2 UF (without heat exchanger) UKF Flow rate: Motor rating: Cooling capacity*: 15 60 l/min 0.75 1.5 kw up to 30 kw UKF-3 UF (without heat exchanger) UKF 2 Flow rate: 20 200 l/min Motor rating: 1.5 4 kw Cooling capacity*: up to 90 kw * Dependent on temperature difference and flow rate of the cold and warm medium (see also Pump-Transfer Cooler Filtration Unit Selection ).

Water quality The following limits are based on a water temperature of +60 C. Substances dissolved in water Concentration Stainless steel Copper ph value Electrical conductivity Cl - <300 SO 4-2 <6.0 0 0 6.0 9.0 0 / + + >9.0 + 0 <500 [μ S/cm] + + >500 [μ S/cm] + 0 + + 0 0 <50 + + 50 300 + 0 >300 0 0 CaCO 3 <50 + + >50 0 0 Fe <0.3 + + >0.3 + 0 NH 3 2 20 + 0 <2 + + >20 + 0 NO 3 <100 + + >100 + 0 S -2 Not suitable SiO 2 <30 + + NH 4 + <0.1 + + Free chlorine <0.1 + + CO 3-2 0: Corrosive +: Suitable <0.4 + + 3

Dimensions / Weight UKF-1 Clearance for filter element removal approx. 50 mm MF160 MF180 N5DM ~135 ~ 250 Water Water out in 208 250 110 out Water in ~ 550 ~ 655 466 HYDAC HEX S610-10 Ø12 ØG1 50 HYDAC HEX S615-10 Water MF160 310 290 MF180 N5DM Weight (unfilled) Basic unit (motor-pump unit + filter) + heat exchanger Motor-pump unit Heat exchanger Basic unit: 12 kg 610-10: 3 kg 610-20: 5 kg 615-10: 6 kg 615-20: 8 kg 4

UKF-2 UF-2 M10 30.2 MF180 58.7 G 1 LF500 ~ 500 ~ 450 ~ 410 15 200 140 ~ 485 430 90 Ø 12.5 208 UKF-2 M10 30.2 MF180 58.7 G 1 LF500 ~ 500 ~ 450 ~ 410 ~ 345 Water 430 15 15 90 Ø 12.5 140 200 50 250 G 1 466 HYDAC HEX S610-XX HYDAC HEX S615-XX ~ 560 Water Weight (unfilled) Motor-pump unit + heat exchanger + filter Motor-pump unit Heat exchanger Filter 0.75 kw: 16 kg 610-20: 11 kg MF180: 2 kg 1.5 kw: 20 kg 610-40: 14 kg LF330: 5 kg 615-20: 14 kg LF500: 7 kg 615-40: 18 kg 5

UKF-3 UF-3 MF180 M12 Ø 50 77.8 42.9 LF660 6 x Ø 11 190 ~ 530 240 ~ 625 95 ~ 570 ~ 525 20 275 315 UKF-3 MF180 Ø 50 77.8 M12 42.9 LF660 ~ 625 ~ 570 ~ 525 ~ 450 Water G 1 190 20 240 466 HYDAC HEX S615-XX ~ 580 95 6 x Ø 11 275 50 Water 6

UKF-3 MF180 M12 Ø 50 77.8 42.9 LF660 ~ 625 ~ 570 ~ 525 ~ 375 G 1 HYDAC HEX S610-XX 250 Water 50 Water 20 ~ 670 190 240 95 6 x Ø 11 275 Weight (unfilled) Motor-pump unit + heat exchanger + filter Motor-pump unit Heat exchanger Filter 1.5 kw: 44 kg 610-20: 11 kg MF180: 2 kg 2.2 kw: 48 kg 610-40: 14 kg LF330: 5 kg 4 kw: 52 kg 610-70: 17 kg LF500: 7 kg 610-100: 22 kg LF660: 8 kg 610-120: 25 kg 615-20: 14 kg 615-40: 18 kg 615-60: 24 kg 615-80: 30 kg 7

Model Code Type UKF UF UK = Pump + heat exchanger + filter = Pump + filter = Pump + heat exchanger Version 1.0 = Heat exchanger series 610 2.0 = Heat exchanger series 615 1.2 / 2.2 = With filter bypass Seals P+V P = Static seal Perbunan + Dynamic seal Viton = Static and dynamic seal Perbunan Pump flow rate: cm 3 /revolution cm 3 /revolution 1,000 1/min 1,500 1/min UKF-1 3.5 5 l/min 5 7.5 l/min 7 10 l/min 10 15 l/min UKF-2 15 15 l/min 20 l/min UKF-2 / UKF -3 20 20 l/min 30 l/min 30 30 l/min 45 l/min 40 40 l/min 60 l/min UKF-3 50 50 l/min 75 l/min 60 60 l/min 90 l/min 70 70 l/min 105 l/min 100 100 l/min 150 l/min 130 130 l/min 180 l/min UKF-2-1.0 - P - 40-1.5-610-40 - MF180-10 - D Motor UKF-1 0.37 kw @ 1,500 1/min 0.55 kw @ 1,500 1/min UKF-2 0.75 kw @ 1,500 1/min UKF-2 / UKF -3 1.1 kw @ 1,000 1/min (6-pole motor) 1.5 kw @ 1,500 1/min UKF-3 2.2 kw @ 1,500 1/min 2.2-6p kw @ 1,000 1/min (6-pole motor) 4 kw @ 1,500 1/min 4-6p kw @ 1,000 1/min (6-pole motor) Plate heat exchanger No. of plates 610-10 -20-30 -40-50 -60-70 -100-120 UKF-1 UKF-2 UKF-3 615-10 -20-30 -40-60 -80 UKF-1 UKF-2 UKF-3 Other plate heat exchangers on request. Filter N5AM/DM MF160 MF180 LF330 LF500 LF660 UKF-1 UKF-2 UKF-3 Filtration rating -03 = 3 μm -05 = 5 μm -10 = 10 μm -20 = 20 μm For further details on filter elements, see relevant brochure in Fluid Filters catalogue. Differential pressure of clogging indicator D = visual-electrical Additional clogging indicators on request, see relevant brochure in Fluid Filters catalogue. 8

Pump-Transfer Cooler Filtration Unit Selection Determining the cooling capacity Estimating the cooling capacity requirements for mineral oil based on increase in tank temperature p = T x V x 1 t 35 p = heat dissipation [kw] T = temperature increase in the reservoir [K] V = tank capacity [l] T = operating time [min] Example: In an system, the tank temperature rises from +20 C to +70 C (= 50 K) in 30 minutes. The tank volume is 100 l. p = 50 x 100 x 1 30 35 p = 4.8 [kw] Selection of the plate heat exchanger: A sizing program is available to calculate accurately the required cooling capacity and a suitable plate heat exchanger. For this, five of the following seven variables are required: l inlet and outlet temperature l flow rate l Water inlet and outlet temperature l Water flow rate l Cooling capacity Additionally, the viscosity of the oil is required. The following graphs show the selection of plate heat exchangers based on cooling capacity. Estimating the cooling capacity requirement based on installed electrical power p ¼ x installed electrical power Calculating the oil and water outlet temperature Drop in oil temperature: T p x 36 Q Increase in water temperature: T p x 14.4 Q Water p Q Q Water = Cooling capacity [kw] = flow rate [l/min] = Water flow rate [l/min] 9

UKF-1 Operating condition: T = +55 C; oil ISO VG 46; Q Q Water = 1 5.00 4.50 4.00 3.50 Cooling capacity at 5 l/min 615-20 615-10 610-20 610-10 Cooling capacity kw Cooling capacity kw Cooling capacity kw 3.00 2.50 2.00 1.50 1.00 0.50 0 10 15 20 25 30 35 40 Water temperature C Cooling capacity at 10 l/min 8.00 7.00 6.00 5.00 4.00 3.00 2.00 1.00 0 10 15 20 25 30 35 40 Water temperature C Cooling capacity at 15 l/min 10.00 9.00 8.00 7.00 6.00 5.00 4.00 3.00 2.00 615-20 615-10 610-20 610-10 615-20 615-10 610-20 610-10 1.00 0 10 15 20 25 30 35 40 Water temperature C 10

UKF-2 Operating condition: T = +55 C; oil ISO VG 46; Q Q Water = 4 Cooling capacity kw Cooling capacity kw Cooling capacity kw Cooling capacity at 20 l/min 12.00 11.00 10.00 9.00 8.00 7.00 6.00 5.00 4.00 10 15 20 25 30 35 Water temperature C Cooling capacity at 45 l/min 25.00 23.00 21.00 19.00 17.00 15.00 13.00 11.00 9.00 7.00 10 15 20 25 30 35 Water temperature C Cooling capacity at 60 l/min 35.00 30.00 25.00 20.00 615-40 615-20 610-40 610-20 615-40 615-20 610-40 610-20 615-40 615-20 610-40 610-20 15.00 10.00 10 15 20 25 30 35 Water temperature C 11

UKF-3 Operating condition: T = +55 C; oil ISO VG 46; Q Q Water = 4 24.00 22.00 20.00 Cooling capacity at 45 l/min 615-40 615-20 610-40 610-20 Cooling capacity kw 18.00 16.00 14.00 12.00 10.00 8.00 6.00 10 15 20 25 30 35 Water temperature C Cooling capacity kw Cooling capacity kw Cooling capacity at 105 l/min 55.00 50.00 45.00 40.00 35.00 30.00 25.00 20.00 15.00 10 15 20 25 30 35 Water temperature C Cooling capacity at 185 l/min 100.00 90.00 80.00 70.00 60.00 50.00 40.00 615-60 615-40 610-100 610-40 615-80 615-60 610-120 610-70 30.00 20.00 10 15 20 25 30 35 Water temperature C 12

Viscosity Viscosity / temperature graph to D 51519 Viscosity index 50 Viscosity / temperature graph Viscosity index 0 to 200 oil ISO VG 320 100,000 10,000 10,000 5,000 4,000 3,000 ISO VG 1500 2,000 Kinematic viscosity in mm²/s 1,000 500 400 300 200 100 50 40 30 20 10 ISO VG 1000 ISO VG 680 ISO VG 460 ISO VG 320 ISO VG 220 ISO VG 150 ISO VG 100 ISO VG 68 ISO VG 46 ISO VG 32 ISO VG 22 ISO VG 15 ISO VG 10 ISO VG 7 Kinematic viscosity in mm²/s 1,000 100 5 4 3 2 1 To D 51519, viscosity index 50, Temperature of medium (oil) +10 C to +80 C; short-term operation at higher viscosities (cold start) is permitted. 10 VI = 200 VI = 150 VI = 100 VI = 50 VI = 0 ISO VG 5 ISO VG 3 ISO VG 2 1 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Temperature in C Temperature in C The viscosity index indicates how much the viscosity of the oil changes with temperature. It is a measure of the temperature properties of different oils. The higher the viscosity index of an oil, the smaller the change in viscosity in relation to the temperature. 13

Graphs for motor-pump selection UKF-1 900 800 700 Motor: 0.2 kw DC 3 cm³/rev-0.2 kw 7 cm³/rev-0.2 kw 10 cm³/rev-0.2 kw Viscosity mm²/s 600 500 400 300 200 100 0 1 1.5 2 2.5 3 3.5 4 p bar 3,000 2,500 Motor: 0.37 kw 5 cm³/rev-0.37 kw 7 cm³/rev-0.37 kw 10 cm³/rev-0.37 kw Viscosity mm²/s 2,000 1,500 1,000 500 0 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 p bar 14

UKF-2 400 350 300 Motor: 0.75 kw 15 cm³/rev-0.75 kw 20 cm³/rev-0.75 kw 30 cm³/rev-0.75 kw 40 cm³/rev-0.75 kw Viscosity mm²/s 100 50 0 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 p bar Motor: 1.5 kw 0 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 p bar 250 200 150 Viscosity mm²/s 2,000 1,800 1,600 1,400 1,200 1,000 800 600 400 200 15 cm³/rev-1.5 kw 20 cm³/rev-1.5 kw 30 cm³/rev-1.5 kw 40 cm³/rev-1.5 kw 15

UKF-3 700 600 500 Motor: 2.2 kw 30 cm³/rev-2.2 kw 40 cm³/rev-2.2 kw 50 cm³/rev-2.2 kw Viscosity mm²/s 400 300 200 100 0 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 p bar Motor: 4 kw 400 200 0 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 p bar 1,600 1,400 1,200 70 cm³/rev-4 kw 100 cm³/rev-4 kw 130 cm³/rev-4 kw Viscosity mm²/s 1,000 800 600 16

Filter selection Cleanliness requirements for lubricating and hydraulic components. The cleanliness level required in lubricating and hydraulic systems is determined by the most sensitive component. Type of system/area of application/ Components Systems with servo hydraulics sensitive to fine contamination Industrial hydraulics l Proportional technology l High pressure systems Industrial and mobile hydraulics l Electromagnetic control valve technology l Medium pressure and low pressure systems Industrial and mobile hydraulics with low demands on wear protection Recommended cleanliness class 15/13/10 17/15/12 18/15/12 19/16/14 20/18/15 Forced-feed circulatory lubrication on gears 18/16/13 New oil 21/19/16 Pumps/ Motors l Axial piston pump 18/16/13 l Radial piston pump 19/17/13 l Gear pump 20/18/15 l Vane pump 19/17/14 Valves l Directional valves 20/18/15 l Pressure control valves 19/17/14 l Flow valves 19/17/14 l Check valves 20/18/15 l Proportional valves 18/16/13 l Servo valves 16/14/11 Cylinders 20/18/15 Depending on the conditions of the system and the environment, filters with the same filtration rating perform differently. Typical fluid cleanliness classes achieved with HYDAC elements are shown below: Filtration rating x (β x(c) 200) 25 19/16/13 22/19/16 20 18/15/12 21/18/15 15 17/14/11 20/17/14 10 15/12/9 19/16/13 5 12/9/6 17/14/11 3 10/7/4 13/10/7 10/7/4 11/8/5 12/9/6 13/10/7 14/11/8 15/12/9 16/13/10 17/14/11 18/15/12 19/16/13 20/17/14 21/18/15 22/19/16 cleanliness to ISO 4406 17

Notes On piping The pressure differential in a hydraulic line is dependent on: l Flow rate l Kinematic viscosity l Pipe dimensions and can be estimated for hydraulic oils as follows: l [m] Δp[bar] = 5.84 x d 4 x Q x v [bar] [mm] Note The information in this brochure relates to the operating conditions and applications described. For applications and operating conditions not described, please contact the relevant technical department. Subject to technical modifications. l = Pipe length [m] d = Internal diameter of pipe [mm] Q = Flow rate [l/min] n = Kinematic viscosity [mm²/s] This applies to straight pipe runs and hydraulic oils, and to laminar flow. Additional threaded connections and pipe bends increase the pressure differential. Notice l As few threaded connections as possible l Few pipe bends; if unavoidable, use large radius l Difference in height between pump and oil level as small as possible l Hoses must be suitable for a vacuum of min. 5,000 mmw l Do not reduce pipe cross-section predetermined by the unit HYDAC COOLG GMBH Industriegebiet 66280 Sulzbach/Saar Germany Tel.: +49 6897 509-01 Fax: +49 6897 509-454 E-mail: cooling@hydac.com Internet: www.hydac.com 18