CRK24-B1 Heated/chilled ceiling system



Similar documents
Temperature controller for heated/chilled ceiling systems

CR24-.. Single room controllers

HVAC Processes. Lecture 7

NEWS Room temperature controller CR24. System solutions for individual room comfort

RDG/RDF room thermostats

Building Technologies

Federation of European Heating, Ventilation and Air-conditioning Associations

Smile. The All-In-One Heating Controller

RRV934. Multi-controller. Synco living

Belimo Gateway MP to Modbus RTU - UK24MOD

Product and Application Description


RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

HCE80/HCC80/HCE80R/HCC80R

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

Condensing Boiler Efficiency

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Federation of European Heating, Ventilation and Air-conditioning Associations

INFO VA1-03 Retrofitting Globe Valves. Selection guide for retrofitting HVAC control valves

ABB i-bus KNX Fan Coil Controller FC/S 1.1

User Manual THR840DUK Digital Thermostat

What s the Difference? 2 Pipe vs 4 Pipe Fan Coil

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Controls for fan coil units and cassettes

Intelligence down to the last detail.

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Electronic Control Devices The European Product Catalogue 2007

Energy efficiency in building automation and control

KONRAD. Hybrid Fancoil Series

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Lesson 36 Selection Of Air Conditioning Systems

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Glossary of Heating, Ventilation and Air Conditioning Terms

Integrated Solar Radiant Systems

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Heating Controller. Building Technologies HVAC Products

HERZ-Thermal Actuators

PRODUCT MANUAL IRSC. IRSC-Plus. Air-Conditioning controller ZN1CL-IRSC. Program version: 5.14 Manual edition: 5.14_a

Building automation and control system

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

Flush-mounted room thermostats

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T

Energy efficiency in building automation and control

HEATER, AIR CONDITIONING AND VENTILATION

Fundamentals of HVAC Control Systems

Thermostat with display

Using Building Energy Management Systems (BEMS) Best Practice for Energy and Carbon Savings.

1 General information

flexotron 800: Electronic ventilation, air-conditioning and heating controller

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

2-Stage, 3-phase controller Type 30051/

Hiwall Hiross for Telecom. High Performance Air Conditioning

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Heating, ventilation and air conditioning (HVAC) equipment. A guide to equipment eligible for Enhanced Capital Allowances

Heating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

Small-Scale Solar Heating and Cooling Systems

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

HEATING, VENTILATION & AIR CONDITIONING

How To Get A Passive House

HDA

Cooling with CHW (fan coil Heating with LTHW radiator Modulating control of heating and cooling valve Automatic or manual fan control

Automatic control equipment for HVAC systems

Comfort Compact Controller ZG 215N

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Trinchero Family Estates Building: Operation User s Guide

Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

KNX for building and room automation simple and efficient

VAV system solution for non-pressure-dependent applications in enclosed spaces

Inwall Room Temperature Unit

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

- White Paper - Data Centre Cooling. Best Practice

Technical Support Bulletin Nr. 20 Special AC Functions

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

Floor systems - key elements for sustainable multi-storey buildings

INTEC Engineering GmbH Heating Solutions for the Marine Industry

3-2. Using the air conditioning system and defogger Automatic air conditioning system

Building Energy Systems. - HVAC: Heating, Distribution -

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

DesignBuilder EMS - Intro

We have been working in an ideal climate for thirty years.

Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats

basicdim DGC Compact control module

3466 Building Energy Management Training Systems

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

BBD 2015 Presentation HVAC, Control, and Plumbing Systems for Thermos Bottle Buildings Roy Swain, P.E. February 5, 2015

Adjustable room thermostat for heating only or cooling only systems

Transcription:

CRK4-B1 CRK4-B1 Heated/chilled ceiling system Table of contents Principle 3 Night switch-off: Regulating the 6-way valve with Energy Hold Off (EHO) 4 All options: 6-way valve regulation with pre-comfort, Energy Hold Off (EHO) and dew point limiter 7 www.belimo.eu A4-CRK4-B1 en v1.1 10.009 Subject to changes 1 / 1

/ 1 A4-CRK4-B1 en v1.1 10.009 Subject to changes www.belimo.eu

Principle Description, function Heated/chilled ceiling system Suspended ceilings are usually installed as room panelling in commercial premises such as offices, event and meeting rooms, sales and presentation buildings, functional areas in hospitals, etc. This is a typical area of application for heated/chilled ceilings. Chilled ceilings function in accordance with the principle of quiet cooling, i.e. temperatures are not permitted to fall below the dew point. Depending on the selected water temperature, this technology can be used for either heating or cooling. Furthermore, ceiling systems also have under certain circumstances additional aesthetic, spatial acoustics and lighting functions. Water is used to lower the surface temperature of the chilled ceiling to a few degrees below the room temperature, although it remains constantly above the dew point. Because of the fact that the majority of most heat sources release heat via radiation and function without forced convection, the physical action principle of the chilled ceiling is the most comfortable solution for spaces devoted entirely to office functions. For the ventilation of larger-sized interior heat loads and high levels of air humidity, chilled ceilings are nevertheless more limited in their effectiveness than fancoil units because of maximum cooling output considerations. Thermal construction element activation (also: concrete core activation) refers to systems which utilise building masses for temperature regulation. These systems are used for sole or supplementary room heating and/or cooling. One such system is the thermoactive ceiling [Thermoaktive Decke (TAD)]. (Switzerland TABS = thermoactive component [Bauteil] system). Pipelines are laid during the construction of solid ceilings, usually plastic piping. Water flows through these pipes as a medium for heating and/or cooling. The entire solid ceiling through which the water flows is thus thermally activated as a transfer and storage mass. The solid structural component either radiates or absorbs the heat across its entire surface, depending on the heating or cooling situation. System temperature differences remain low because of the comparatively large transference surface. This means that the medium needs not be heated up to the same extent as, for example, the water in a central heating system that uses heaters with a significantly smaller transference surface. Heat pumps, for example, can be efficiently utilised for heating because of these lower supply temperatures. Environmentally friendly energies such as free heat exchange, sole plate cooling or ground water cooling are appropriate sources of cooling. Hygienic air change The atmosphere in which one feels comfortable and in which one then can work productively is not dependent solely on the temperature. Air quality is also a decisive factor, as is also air hygiene. Combined systems comprising heated/chilled ceilings and VAV systems are therefore ideal. The air is primarily responsible for hygienic air changes and also has an additional supportive effect on temperature behaviour. The majority of VAV controllers are connected to a central regulating unit. It is for that reason that we are not offering a detailed discussion of this combination application in the present document. Principle diagram DDC controller 1 M 1 Cold water Low temperature hot water www.belimo.eu A4-CRK4-B1 en v1.1 10.009 Subject to changes 3 / 1

Night switch-off: Regulating the 6-way valve with Energy Hold Off (EHO) Description, function Heater/chiller ceiling application with 4-pipe system in connection with the 6-way ball valve and the room temperature controller CRK4-B1. The entire regulating system is blocked by an external switching contact in order to avoid unnecessary energy consumption during prolonged absences or when windows are open. The protection of the building continues to be guaranteed by the fact that the limits during this Energy Hold Off (EHO) are fixed at 15 C for heating and 40 C for cooling. If temperatures fall below the limit values or exceed them, respectively, the system switches on until the setpoint values are achieved once again. For added safety, the frost function is naturally also activated with a switch-on point of 10 C. Principle diagram 1 M EHO 1 Cold water Low temperature hot water Functional diagram Valve opening [%] 100 EHO 0 Frost W A current setpoint Dead band W s Compensation t Room [ C] Connection, allocation CRK4-B1 AC 4 V ~ EHO 3 4 5 U5 1 U5 ai1/di1 di ai 1 6 7 8 CRK4-B1 1 3 5 y U5 ~ Actuator for 6-way valve 4 / 1 A4-CRK4-B1 en v1.1 10.009 Subject to changes www.belimo.eu

Regulating the 6-way valve with Energy Hold Off (EHO) Input and output allocation Inputs - di Energy Hold Off (EHO) - U5 1 Diagnostics connection (useful only when using the LR4A-MP actuator) Outputs - System output 6-way ball valve Override functions If more than one override function is switched on at the same time, then the one with the highest priority will be activated. Priority 1: Priority : Room protection (Frost) This function is activated when the room temperature falls below 10 C (protective function). Energy Hold Off (di) The heated/chilled ceiling is switched off in order to avoid unnecessary energy consumption during prolonged absences or when windows are open. The regulating control is however enabled once more when temperatures fall below the limit values or exceed them (<15 C/>40 C). Functions P1: Room protection P: EHO P: EHO P: EHO Components t R <10 C t R <15 C t R >40 C 6-way valve () Heating CLOSED Control mode Control mode List of materials Room temperature controller, AC 4 V CRK4-B1 6-way valve Actuator, AC 4 V /... 10 V EXT-K3B-..-.. LR4A-MP LR4A-SR Configuration, adjustment setting CRK4-B1 DIP Function Setting 1 Switching P-band Normal Wide 6-way output Modulating On/Off Function diagram 6-way valve with modulating control (DIP position) ON OFF 1 [V] 10 7.3 (heating) l 4.7 (cooling) 0 10 33 66 90 100 [%]. www.belimo.eu A4-CRK4-B1 en v1.1 10.009 Subject to changes 5 / 1

Regulating the 6-way valve with Energy Hold Off (EHO) Function diagram 6-way valve with On/Off control (DIP position) ON OFF 1 [V] 10 (heating) l 6 (cooling) 0 10 33 66 90 100 [%]. Operating Operating mode Setpoint AUTO AUTO ECO MAX Rotary button on the front 6 / 1 A4-CRK4-B1 en v1.1 10.009 Subject to changes www.belimo.eu

All options: 6-way valve regulation with pre-comfort, Energy Hold Off (EHO) and dew point limiter Description, function Heater/chiller ceiling application with 4-pipe system in connection with the 6-way ball valve and the room temperature controller CRK4-B1. The entire regulating system is blocked by external switching contacts. The dew point limiter blocks the cooling and moves the ball valve into neutral position. The energy stop is used to fix the setting limits at 15 C for heating and 40 C for cooling. In the meantime, the valve remains in the energy-neutral zone. The room is regulated for readiness during pre-comfort operation. The nominal heating value is lowered by 3K and the nominal cooling value is raised by 3K. For added safety, the frost function is also naturally activated with a switch-on point of 10 C. Principle diagram External shifting 1 M 1 Cold water Low temperature hot water Functional diagram Valve opening [%] 100 Pre-comfort EHO 0 Frost Dew point Dead band W s Compensation t Room [ C] W A current setpoint Connection, allocation CRK4-B1 AC 4 V ~ External NTC temperature sensor 0 10 V Shifting Pre-comfort 3 4 5 U5 1 U5 ai1/di1 di ai 1 6 7 8 CRK4-B1 EHO Dew point limiter 1 3 5 y U ~ Actuator for 6-way valve www.belimo.eu A4-CRK4-B1 en v1.1 10.009 Subject to changes 7 / 1

6-way valve regulation with pre-comfort, Energy Hold Off (EHO) and dew point limiter Input and output allocation Inputs - ai/di1 Pre-comfort/Temp. Sensor - di Energy Hold Off (EHO)/dew point limiter - ai ext. setpoint shift - U5 1 Diagnostics connection (useful only when using the LR4A-MP actuator) Outputs - System output 6-way ball valve Override functions If more than one override function is switched on at the same time, then the one with the highest priority will be activated. Priority 1: Priority : Priority 3: Room protection (Frost) This function is activated when the room temperature falls below 10 C (protective function). Energy Hold Off (EHO)/dew point limiter (di) The heated/chilled ceiling is switched off in order to avoid unnecessary energy consumption during prolonged absences or when windows are open. The regulating control is however enabled once more when temperatures fall below the limit values or exceed them (<15 C/>40 C). Pre-comfort (di1) If a local sensor (e.g. motion detector) has an effect on the input d1, then the room is set to Pre-comfort. The nominal heating value is lowered by 3K and the nominal cooling value is raised by 3K. Functions P1: Room protection t R <10 C P: EHO Dew point value P: EHO t R <15 C P: EHO t R >40 C P3: Pre-comfort Components 6-way valve () Heating CLOSED Control mode Control mode Lowered control mode List of materials Room temperature controller, AC 4 V CRK4-B1 6-way valve Actuator, AC 4 V /... 10 V EXT-K3B-..-.. LR4A-MP LR4A-SR Configuration, adjustment setting CRK4-B1 DIP Function Setting 1 Switching P-band Normal Wide 6-way output Modulating On/Off Function diagram 6-way valve with modulating control (DIP position) ON OFF 1 [V] 10 7.3 (heating) l 4.7 (cooling) 0 10 33 66 90 100 [%]. / 1 A4-CRK4-B1 en v1.1 10.009 Subject to changes www.belimo.eu

6-way valve regulation with pre-comfort, Energy Hold Off (EHO) and dew point limiter Function diagram 6-way valve with On/Off control (DIP position) ON OFF 1 [V] 10 (heating) l 6 (cooling) 0 10 33 66 90 100 [%]. Operating Operating mode Setpoint AUTO AUTO ECO MAX Rotary button on the front www.belimo.eu A4-CRK4-B1 en v1.1 10.009 Subject to changes 9 / 1

10 / 1 A4-CRK4-B1 en v1.1 10.009 Subject to changes www.belimo.eu

All-inclusive. 5-year warranty On site around the globe Complete product range from one source Tested quality Short delivery times Comprehensive support Switzerland Germany Austria Slovakia BELIMO Automation AG Sales Switzerland Brunnenbachstrasse 1 CH-8340 Hinwil Tel. +41 (0)43 843 6 1 Fax +41 (0)43 843 6 66 verkch@belimo.ch www.belimo.ch Benelux BELIMO Servomotoren BV BENELUX Postbus 300, NL-8160 AH Epe Radeweg 5, NL-8171 MD Vaassen Tel. +31 (0)578 57 68 36 Fax +31 (0)578 57 69 15 info@belimo.nl www.belimo.nl BELIMO Stellantriebe Vertriebs GmbH Welfenstrasse 7 D-70599 Stuttgart Tel. +49 (0)711 1 67 83-0 Fax +49 (0)711 1 67 83-73 info@belimo.de www.belimo.de At no charge Orders: Tel. 0711 1 67 83-83 Technical consultation: Tel. 0711 1 67 83-84 Fax 0711 1 67 83-73 Personal consultation with Regional Sales Director in: Berlin, Hanover, Düsseldorf Leipzig, Frankfurt, Munich Hamburg, Stuttgart BELIMO Automation Handelsgesellschaft m.b.h. Geiselbergstrasse 6-3 A-1110 Vienna, Austria Tel. +43 (0)1 749 03 61-0 Fax +43 (0)1 749 03 61-99 info@belimo.at www.belimo.at Austria West Tel. +43 (0)644 14 6 365 Fax +43 (0)73 70 10 51 dietmar.niederhametner@belimo.at Hungary Tel. +36 (06)0/90 46 16 Fax +36 (06)3/37 77 30 gabor.koeves@belimo.at Tel. +43 (0)1 749 03 61-0 Fax +43 (0)1 749 03 61-99 info@belimo.at Slovenia/Croatia/Bosnia Tel. +386-(0)41-75 89 63 Fax +386-(0)4-34-761 samo.smid@belimo.at Serbia/Montenegro/ Macedonia/Bosnia Tel./Fax +381-(0)11 311-917 branimir.petrovic@belimo.at Belimo worldwide: www.belimo.com