ELITE CLASSIC WIRELESS ELECTRICITY MONITOR

Similar documents
ENERGY AWARE. Monitor User Guide

EnergySmart monitor user instructions

Micro Wireless Electricity Monitor

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

IN-OUT Thermometer with Cable Free Sensor and Clock

Drayton Digistat +2RF/+3RF

WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential Control Panels

INSTRUCTION MANUAL MONITOR REDUCE SAVE ENERGY MANAGEMENT SOFTWARE ENERGY MANAGEMENT SOFTWARE

Getting started with

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

GSM Alarm System User Manual

Wireless Home Security Alarm System AM 500

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

MONITOR REDUCE SAVE INSTRUCTION MANUAL ENERGY MANAGEMENT SOFTWARE. For Windows XP, Vista, Windows 7 ( 32 & 64 bit ) Mac OSX 10.5+

RADIO CONTROLLED DIGITAL CLOCK MODELS / 88906

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

RF Projection Barometer With Remote Thermo Sensor

Solo II CT: Consumption USER MANUAL

Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

Portable Air Conditioner

WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential and Small Business Control Panels

Ecomind Electricity Monitoring Software 2.1. Software Manual

SMART ENERGY IN-HOME DISPLAY USER MANUAL

MAGICAR M871A. Car alarm with two-way remote User s guide

LCD Display. Function keys. Stand. Adapter socket

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

Wireless Indoor/ Outdoor Thermometer

Model: Manual DC: WIRELESS COLOR FORECAST STATION

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

4.3-inch Back-Up Camera

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Installation Guide for Hive Active Heating

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

Installer Guide smart connect

Wireless Home Security System Product Manual (Model #80355)

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

ReSound Unite TV FREQUENTLY ASKED QUESTIONS. Setup & Configuration. Use & Operation. Troubleshooting

Welcome to Smart Pay As You Go

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

Section B: Electricity

The Traxxas TQ-3 Radio System

90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F

GSM HOME SECURITY SYSTEM

Radio Thermostat Clock Part Number: Installation & User Instructions. Suitable for all Ferroli Combination Boilers

How To Program An Autodialer

MEMO ALARM CLOCK Operating Manual

FSLIMRF

WIRELESS MAGNETIC CONTACT

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Odyssey of the Mind Technology Fair. Simple Electronics

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

T0118 T2118 T3118. Instruction Manual

mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start

The Weather Station. Hanging Hole. LCD Display Battery Cover. Function Keys. Detachable Stand

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Wireless Alarm system s manual

WIRELESS HOME ALARM SYSTEM (WHA1)

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Stove Guard Kit User Manual

Current Cost TREC Current Cost ENVI Current Cost EnviR SmartNow Solar Monitoring Kit

REMOTE TERMOMETER TE 219 LED USER MANUAL

G-100/200 Operation & Installation

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Total Protection Alarm System

4P H. Wireless LAN Connecting Adapter <BRP069A41> Installation Manual

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5

Alarm Security Kit - NVR

Operating Manual Remote Cost Control Monitor

DAB1001. Wireless Digital Radio Interface. Installation & User Guide

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Your Simple Guide to Battery. Replacement. Customer Care:

Digital Radio/DAB+/FM RDS digital clock radio with dual alarm Operating instruction

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

Power Socket (2 Gang)

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

GSM Autodialer Professional GJD700 Speech & Text Autodialer

EWR2 WIRELESS SIGNAL REPEATER

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Contents Contents Contents Overview Charging your headset Wearing the headset Powering on the headset Connecting your headset for dictation

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Targus Wireless RF Mouse USER S GUIDE. Making Your Mobile Life Easier.

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

WIRELESS WEATHER STATION Model USER'S INSTRUCTIONS

Safety Warnings and Guidelines

INFRARED QUARTZ WALL HEATER

Water Tank Level Monitor

Security System Owner s Manual

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

EDGE 800. quick start manual TOUCHSCREEN GPS-ENABLED BIKE COMPUTER

Transcription:

ELITE CLASSIC WIRELESS ELECTRICITY MONITOR 5600 At the end of its serviceable life, this product should not be treated as household general waste. It should be handed over to the applicable collection point for the recycling of electrical equipment, or returned to the supplier for disposal. *All values shown in this manual are only examples. Actual figures will vary depending on your consumption. INSTRUCTION MANUAL

CONTENTS INTRODUCTION INTRODUCTION SAFETY IN THE BOX HARDWARE INSTALLATION Prior to Installation Mounting Individual or Multiple Circuits Monitor Installation Considerations Installing the CT Sensor MONITOR SETUP Linking Transmitter and Monitor Setting the Time & Date Setup Instructions Dual Tariff Mode Energy Now Mode History Mode FAQs TECHNICAL INFORMATION INSTALLATION NOTES TECHNICAL NOTES FOR ELECTRICIAN 2 3 5 6 7 9 10 11 12 13 15 16 17 18 19 19 20 Energy metering and monitoring are at the heart of energy management, understanding when and where your energy is consumed is key to saving money. The elite wireless electricity monitor shows the amount of energy that a household is consuming at the time the display is read. The display can also give the user a reading showing usage in financial terms. You can walk around the home with your monitor device, switching appliances on and off, to see the difference that each one makes. With a few small changes in your consumption behaviour the elite can help you reduce your energy costs. Ask George If you have any questions about using your elite efergy monitor or if you d like further advice on monitoring electricity at home, please feel free to contact us, or visit the website for up to date information, downloads and frequently asked questions. Email your questions to: info.aus@efergy.com Email your technical questions to: askgeorge@efergy.com We aim to answer all your emails within 48 hours. Efergy Customer Service: (+61) 1300 799 851 www.efergy.net.au 2

IMPORTANT SAFETY INFORMATION It is important that you take some simple precautions before using this product. Incorrect use or poor safety practices can result in injury or fatality. Whenever possible, turn off the main breaker, outside your home feeding power to your electric panel. When installing the elite monitor you should find that everything is straight-forward. However, there are a number of important health and safety issues which you need to be aware of: Mini CT sensor clip fits onto the internal live feed cable inside the electricity meter, which delivers the live supply to your home. Do not touch any metallic connections during the installation of the mini CT sensor. Do not carry out this installation if under the influence of alcohol or drugs. Remember the device is not intrusive and does not require rewiring; no wires or cables need to be cut, removed or modified to perform this installation. If you notice anything unusual about the electricity supply such as loose wires, exposed cabling, burn marks, holes in the insulating materials or damage to the electric wires in the service panel or where the mini CT sensor is to be attached, stop immediately and report the findings to your supply company. The user does not need to remove the sensor throughout the working life of the unit. Battery changes are performed on the transmitter and on the display. There are no batteries to change in the sensor. Even with the main breaker in the off position, the connection lugs where the main wires terminate at the main breaker may still be live with potentially lethal voltage. Stay clear of these connections during the installation of the mini CT sensor, see page 9. The mini CT sensor itself is insulated so do not be concerned if it slides down the main wire to the breaker after being secured around the insulated wire. A plastic tie wrap (with 5cm of the tie not cut off) secured to the main wire under the desired location for the sensor may be used to keep the sensor from sliding down the wire. Millions of these systems have been installed world wide without incident but please follow safe work practices as outlined during the installation. efergy energy monitoring systems are considered plug and play devices that meet all regulatory requirements for installation in Australia In Australia the live cable can only be accessed by qualified electricians. Do not force or bend the cables at any point during installation. If you are worried or have any concerns about the installation, please contact a qualified electrician immediately. 3 4

IN THE BOX HARDWARE INSTALLATION PRIOR TO INSTALLATION Your elite pack contains the following elements: 1 x mini CT Sensor 1 x Transmitter 1 x elite Wireless Energy Monitor Mini CT Sensor Transmitter The efergy elite is installed by clipping the mini CT sensor around the feed wire of your electric panel. In Australia the standard residential voltage is 240V. Note - For a 240V panel (typical residential electric panel) power is measured using one mini CT sensor. For different voltages, please change during the Monitor Setup stage (see page 13). You will need to attach the sensor to the live feed cable which connects the meter to the monitor. Any power you use in your home will pass through this cable. The clip on sensor relays the amount of current being drawn in the home to the transmitter. From there it is sent wirelessly to the energy monitor, which shows how much power is being consumed. It also includes: 1 x Instruction manual for the monitor 1 x Quick Start Guide Wireless Energy Monitor Installation for Three Phase Panels The elite is installed by clipping the mini CT sensor around the feed wire of your electric panel. In the case of a commercial or industrial three phase panel or service, you must use three mini CT sensors to measure all three phases. Simply order an additional two mini CT sensors from your dealer. Identify the three power wires providing service to your electric panel. Open and place one sensor around each of the three main feed wires. Installing Transmitter for Three Phase Plug the three mini CT sensor cables into the transmitter. Mount the transmitter on the wall next to the electric panel. This will make it easier to replace the batteries. Readings for a three phase system may not be accurate depending on connection and loading system. 5 WE RECOMMEND THAT THE EFERGY MONITOR IS INSTALLED BY A LICENSED ELECTRICIAN 6

HARDWARE INSTALLATION MOUNTING INDIVIDUAL OR MULTIPLE CIRCUITS Locate Your Electrical Panel Locate your electricity meter and determine its type. You can normally find this on an outside wall, in the garage, basement or utility room. If you live in a flat, it can often be found outside your front door, in the communal stair case, or in the basement. Ensure there is enough of accessible cable coming from the bottom of your electricity meter. Modern office blocks and apartments may have safety panels to protect wires entering the meter. It is recommended that professional electricians be contacted where this is the case. 1 2 3 4 Fig. 1 Dual Tariff Meters Dual Tariff meters (shown in Fig. 3) will often have an auxiliary cable running between cable 3 and cable 4. Auxiliary cables will be smaller in diameter than the feed cables, and will run into an adjoining metering device. Newer installations will normally have two cables exiting from the bottom of the meter. One is the earth cable, the other the live feed cable. The mini CT sensor should be clipped around the live feed cable (this is normally brown coloured). If you have a three phase supply, or economy 7 meter, then you may require additional sensors. These can be simply plugged into the additional sockets at the base of the transmitter. Please contact your supplier for additional sensors. Find the Main Feed Wires for Your Home You should find four cables exiting the meter (see both Fig. 1 and Fig. 2). The feed cable (cable 4) is the live cable exiting from the meter to the fuse box. Connect the mini CT sensor to cable 4. Some installations will have cable 1 and cable 2 covered or partially covered to prevent any tampering with the supply (see Fig. 2). In this case you will still attach the sensor to cable 4. 4 1 2 3 4 1 2 3 Auxilary Cable Fig. 2 Fig. 3 7 8

HARDWARE INSTALLATION INSTALLING THE MINI CT SENSOR The sensor needs to be fitted to the live feed cable. Mini CT sensors are suitable for cables up to 12mm in diameter. You should not force the cable to fit. The sensor should fit loosely around the cable and there should be no packing used. INSTALLING THE MINI CT SENSOR Note - Keep your fingers well away from the metal lugs where the main service wires attach to the breaker, unless you are able to turn off the inbound power from your utility source outside. Wiring configurations and types of main panels will vary greatly. Fig. 4 Fig. 5 1. Pull the release clip to open the mini CT sensor (Fig. 4) 2. Select the correct feed cable, and then place the sensor around it 3. Push the clasp to close around the feed cable securely (Fig. 5) Note - If the cables in your meter box are too big for the mini CT sensor you can order XL CT sensors at www.efergy.com or from your local dealer. IMPORTANT - Always make safety your first priority, see the relevant Important Safety Information (page 3). Under no circumstances should you try to attach the sensor if there is any damage to the meter box cables. No cables need to be cut. Do not cut any cables. In Australia the live cable can only be accessed by qualified electricians. Remove a standard 1cm knock out from the meter box. Feed the mini CT sensor lead from inside the box out through the raw knock out hole. Open and place the mini CT sensor around the live feed cable 4 (Fig.5). Mounting the Transmitter Insert the jack on the end of the mini CT sensor wire into any of the input sockets on the transmitter. The mini CT sensor acts as a current sensor and relays the current being drawn into the home to the transmitter. Mount the transmitter on the wall next to or above the meter box. This will make it easier to replace the batteries (although the batteries will last for a long time). If the panel is in a finished area, you may mount the transmitter inside the meter box. This may reduce transmission distance. Replace the panel cover(s) when finished installing the mini CT sensor. 9 10

MONITOR SETUP LINKING TRANSMITTER AND MONITOR SETTING THE TIME AND DATE Step 1 Ensure three AA batteries (not included) are inserted in the transmitter and wireless energy monitor. Observe polarity when inserting the batteries. Step 2 Press the link button on the back of the wireless energy monitor and hold for two seconds. The transmission signal symbol will flash for one minute or until the transmitter and monitor are linked. Step 3 While the transmission signal symbol in the display flashes, push the link button on the transmitter and wait until the transmission signal symbol becomes solid. Note - The default value for the transmission frequency is six seconds. This means the transmitter is sending information to the display every six seconds. You can change the frequency from 6s to 12s or 18s by pushing and holding the transmitter button for two seconds. Transmission Signal Symbol Dashes indicate signals not linked The elite monitor needs to know the time and date in order to provide you with the correct information. Set the time and date as follows: Step 1 On the reverse of the monitor you will find the time set button. Press and hold for two seconds. The time setup will flash on the monitor. Step 2 Set the hour to the correct time by using the backward and forward buttons. Press the mode/set button once to save the hours. Repeat for minutes, using the mode/set button to confirm. Once the correct time and date have been set, push the mode/set button to save and move onto the date setup. Step 3 Set the month by using the backward and forward buttons. Press the mode/set button to confirm and move onto the day and year. Repeat the same process and then press the mode/set button to save and exit. Hold for 2 seconds history backward forward mode/set Wireless energy Transmitter link monitor link button button 11 12

MONITOR SETUP SETUP INSTRUCTIONS The elite monitor needs to know unit cost per kwh charged by your electricity supplier, along with voltage and alarm settings. The following steps will move through each of these settings. If you have multiple tariff rates, please consult the Dual Tariff Mode section (see page 15). Press and hold down mode/set button for three seconds to enter the setting mode. Note - Throughout the setup process, push history button at any time, your settings will be saved & you will exit the function setting mode. Note - Twenty seconds of inactivity in setting mode will return the monitor to normal display mode without saving changes. Step 1 - Voltage Press and hold mode/set button for two seconds. Default voltage is set at 240V. Use backward and forward buttons to change the voltage. Press mode/set button to save your setting and move into currency selection setting. Step 2 - Currency Selection Select the currency using backward and forward buttons. Default currency will be $. Push mode/set button to confirm and to move onto tariff selection set up. Step 3 - Single Tariff Set Up On release you will see the 1 in the lower right hand corner of the monitor. If you are charged one single tariff push mode/set button to confirm. If you are charged dual or mulitple tariffs see page 15. Step 4 - Electricity Cost Default cost is set at 0.130$/kWh. Use backward and forward buttons to change the cost per kwh. Press mode/set button to save your setting. Step 5 - Carbon Emissions Ratio Now set your carbon emissions ratio. This value can be increased or decreased using backward and forward buttons, press the mode/set button to store the value. We assume an average of 1.00kg.CO2/kWh, this is set as the default value. Step 6 - Alarm Default alarm is set at 5.00kW. If the alarm function is switched on, and you are using more than 5.00kW the alarm will sound and a red light will glow from the bottom of the wireless energy monitor. The value can be decreased or increased using the backward and forward buttons. Press the mode/set button to store the value. To activate and deactivate the alarm at any time push the alarm button on the reverse of the wireless energy monitor. Step 7 - Temperature The temperature setting can be changed between Fahrenheit and Centigrade by pressing the backward and forward buttons. Press the mode/set button to store the value. 13 14

MONITOR SETUP DUAL TARIFF MODE Step 1 - Activation of Dual / Multiple Tariff Press and hold mode/set button for three seconds. On release you will see the voltage setting flash. Press mode/set button twice and you will move onto the tariff selection setting. Now you will see the symbol 1 flash. Press backward and forward buttons to select dual or multiple tariff setup (you can select up to four tariffs). Push mode/set button to confirm. ENERGY NOW MODE Push the mode/set button to change information displayed from kw to cost (displayed in $). Step 2 - Set Start & End Time For Tariff 1 Set the start time for Tariff 1 first using backward and forward buttons. Set the hours and press mode/set button to save and move to minute set up. Set minutes using backward and forward buttons and pushing mode/set button to confirm. Now the FROM symbol will disappear from the monitor and the TO symbol will appear. Repeat the process for setting the time Tariff 1 ends. Continue to set the FROM and TO timings for other tariffs. Step 3 - Set Tariff 1 Rate Use backward and forward buttons to input the cost per kwh and press the mode/set button to save your setting. Tariff 2 setup will flash. Step 4 - Set Tariff 2 Rate Use backward and forward buttons to input the cost per kwh and press the mode/set button to save your setting. Step 5 - Set Tariff 3 & 4 Rate Use backward and forward buttons to input the cost per kwh and press mode/set button to save your setting. Repeat the process for tariff 4. You will always set one period of settings less than the number of tariffs you have selected as the remaining period will be saved automatically. The lower part of the screen shows the estimated cost and carbon emissions per day Shows the instant power in kilowatts When your elite is in the ENERGY NOW mode, this PEAK symbol appears when the most expensive tariff is in use. 15 16

MONITOR SETUP FAQS HISTORY MODE Push the history button to access daily, weekly, and monthly stored data. Use the backward and forward buttons to scroll between dates and compare consumption data. Press mode/ set button to change information from kwh to costs and Co2 emissions. Historical consumption information for days, weeks and months in kwh, $ and KgCO2 If I remove the batteries will I lose the information on the monitor? The monitor has an internal memory, so if you need to change or remove the batteries and the information stored on it will not be lost. How do I reset the monitor (clear the stored data and start again)? Press and hold the mode/set and history buttons simultaneously for two seconds. How far does the device transmit? The transmitter works up to around 230ft/40m within the home. The 433MHz range is well suited for in-home use. This can cover three floors and is also ideal for buildings where electricity meters are situated outside. I have dashes (- - - -) showing on the monitor. What does this mean? Move the monitor closer to the transmitter and press the link button. If the dashes remain on the monitor this would indicate that the transmitter and receiver are not communicating. Please contact our customer services to help solve the problem. Average information in days, weeks, or months in kwh, $ and KgCO2 The backlight appears to work sometimes and then not others. Is it broken? No. The backlight is on a timer to save battery life. The monitor should work at darker periods during the day when any buttons are pressed. The LED backlight will be activated from 18:00 to 6:00 hours. For more information about the elite go to www.efergy.net.au Contact efergy customer service phoneline on (+617) 1300 799 851 17 18

TECHNICAL INFORMATION TECHNICAL NOTES FOR ELECTRICIAN Model Name Model Number Frequency Transmission Time Transmission Range Sensor Voltage Range Measuring Current Memory efergy elite ELITE-AUS 433MHz 6, 12 or 18 Sec 230-328ft 110-400V 50mA - 120A 64K NOTE: This table is for reference only. Accuracy may vary depending on the type of connection and loading system used. ELECTRICITY SYSTEM VOLT SETTING 120V, 3 Wire, Single Phase (Typical Residential Service in US & Canada) 120 240V, 3 Wire, Single Phase 240 120/ 208V, 3 Wire, 2 Phases of a 3 Phase 120/208V Three wires phase 1 live, phase 2 live, Grid 120V is live to neutral and 208 is phase 120 to phase. Assume unbalanced load. 2 CT Sensors 120/ 208V, 4 Wire, 3 Phases, Balanced Load Three phase live, phase 2 live - Neutral, where 120V is phase to neutral and 208V 208 is phase to phase. 1 CT Sensor INSTALLATION NOTES Date 120/ 208V, 4 Wire, 3 Phases, Unbalanced Load The display does not recognize unbalanced loads in this configuration. The degree 120 of accuracy will be relative to the amount of unbalanced current. 3 CT Sensors 208V, 3 Phase Delta Balanced Load 208 277/ 480V, 4 Wire, 3 Phases, Balanced Load Three phase live + neutral, where 277V is phase to neutral and 480V is phase to 480 phase. 1CT Sensor Location Installed Installed By Number of CTs Voltage Set Point Tariff Settings 277/ 480V, 4 Wire, 3 Phases, Unbalanced Load Three phase live + neutral, where 277V is phase to neutral and 480V is phase to phase. The display does not recognize unbalanced loads in this configuration. 277 The degree of accuracy will be relative to the amount of unbalanced current. 3 CT Sensors 230/ 400V, 4 Wire, 3 Phases, Balanced Load Three phase live + neutral, where 230V is phase to neutral and 400V is phase to 400 phase. 1CT Sensor 347/ 575V, 3 Phase, Balanced Load. 1CT Sensor 580 347/ 575V, 3 Phase, Unbalanced Load. The display does not recognize unbalanced loads in this configuration. The degree 350 of accuracy will be relative to the amount of unbalanced current. 3 CT Sensors 19 20