Metal oxide varistor elbow (M.O.V.E.) surge arrester

Similar documents
25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance

Radial Distribution Test Feeders

SANS : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

SURGE PROTECTIVE DEVICES

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Lightning Arresters P KVA P KVA. Description & Installation

ELASTIMOLD CATALOG SP2. Issue Date: 03/2003

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Medium Voltage Electrical Distribution

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

Type MOST oil switch. Technical Data Contents. Effective October 2013 Supersedes March 2000

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

R.C.C.B. s two-pole LEXIC

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

CPS Y S K CPS Y S C

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

16300 MEDIUM VOLTAGE DISTRIBUTION

Applications. Remote Display Mounting Kits

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

3/2-way Solenoid Valve, direct-acting, NC or NO

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

Transformer Bushings for GIS

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

TIG torches to 3-5 Tungsten electrodes to 3-7 TIG consumables Miscellaneous

Hyperlinks are Inactive

Customer Substation Manual 08/05/02

5SV Residual Current Protective Devices

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

IEC Type Test Report Report No. EU1522-H-00.1 PH4 Series Polymer-housed Arrester 20,000 A Line Discharge Class 4

a Nexans company Catalogue 2013

4 Posiflow Proportional Solenoid Valves

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

IRRIGATION PUMPING Table of Contents - Section 900

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

DS 600. A contact free flux gate based current measurement sensor 600A rms

TABLE OF CONTENT

TRANSFORMER DICTIONARY

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Product Selection Guide

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Table of Contents. TransformerIQ FAQs 1

Secondary Unit Substations

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

TC Grounding and Bonding for Telecommunications Systems

Circuit Board Sensor Products

Bourns Resistive Products

a Nexans company Catalogue 2014

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

Intersection Preassembled 19-inch Rack

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

ST Series POWER SUPPLIES USER INSTRUCTIONS

Safety technique. Emergency stop module BO 5988 safemaster

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

Corner-Grounded Delta (Grounded B Phase) Systems

NI-ZN BATTERY SPECIFICATION

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

Unified requirements for systems with voltages above 1 kv up to 15 kv

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Fault location on power cables. Fault location on power cables

Power surges can also be generated by equipment in your facility such as:

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

MEDIUM VOLTAGE DISTRIBUTION

Direction of current flow through conductor. Fig. 1 Magnetic field generated by current flow

handbook, 2 columns handbook, halfpage 085 CS

HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Buck - Boost Transformers

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

38 Series - Relay interface modules A

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

KNOW YOUR OPTIONS: 230 KV POWER CABLES

Low Voltage Products. Switches Automatic Transfer Switches

STREETLIGHT SYSTEM GROUNDING AND BONDING

Z-TRAUQ INC. Tel.: (450) Fax: (450)

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Primary and Secondary Electrical Distribution Systems

TSn SERIES Surge Protective Device

RAY-MAX Integrated Solar Power Strip

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B

CATALOGUE SURGE PROTECTION LOW VOLTAGE

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

Telecommunication Line Protectors

LITHIUM BATTERY CR123A SPECIFICATION

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RC NETWORKS SALES GUIDE

Transcription:

Surge Arresters Catalog Data CA235025EN Supersedes 235-65 August 2011 COOPER POWER SERIES Metal oxide varistor elbow (M.O.V.E.) surge arrester General Eaton combines metal (zinc) oxide varistor technology in a pre molded rubber elbow to provide overvoltage system protection in an insulated, fully shielded, sub mers ible, deadfront device with its Cooper Power series metal oxide varistor elbow (M.O.V.E.) surge arrester. The arrester housing inter face conforms to IEEE Std 386-2006 standard Separable Insulated Connector Systems. The arrester housing is molded of EPDM insulating rubber, which provides deadfront safety in a small, clampstick operable unit. M.O.V.E. arresters are used on underground systems in pad -mounted transformer and entry cabinets, vaults, switching en clo sures and other installations to provide shielded deadfront arrester protection. They are designed for use with 200 A loadbreak interfaces that conform to IEEE Std 386-2006 standard to limit over volt ages to ac cept able levels, protect equip ment and extend cable life. Construction The rubber body is constructed of high quality precision molded peroxide-cured EPDM insulation and semi-conductive materials. The copper alloy probe and probe retainer are connected to the MOV block stack via welded flexible tin-plated copper leads. This ensures that the column cannot be damaged during installation and that a reliable current path to the MOV blocks is maintained. The disk column is composed of MOV disks bonded together with high-conductivity, silver-loaded epoxy to yield the most reliable electrical connection and eliminate air voids. The #4 AWG flexible copper ground lead, which reliably carries current to ground during voltage surges, is attached to the housing by a brass magneformed end cap. The brass end cap provides a tight, weatherproof seal.

Catalog Data CA235025EN Metal oxide varistor elbow (M.O.V.E.) surge arrester PULLING EYE Stainless steel reinforced pulling eye allows easy installation and removal using a clampstick. MOV DISK COLUMN MOV disks are rigidly joined into a single assembly, with high conduc tiv ity silver-loaded epoxy to ensure reliable connection between blocks. WELDED LEADS Flexible welded tin-plated copper leads between probe assembly and MOV column ensure that the column cannot be damaged during installation and that a reliable current path to the MOV blocks is maintained. SEMI-CONDUCTING SHIELD High quality peroxide-cured semi-conducting EPDM shield meets re quire ments of IEEE Std 592-2007standard. IDENTIFICATION LABEL Identifies arrester type, rating and MCOV. SILVER EPOXY CONDUCTIVE BOND EPDM INSULATION High quality peroxide-cured EPDM insulation is mixed and formulated in-house for complete control of raw rubber characteristics. DRAIN WIRE TAB Tab ensures that jacket remains at ground potential, meeting safety practice requirements. Tab is located away from pulling eye to minimize clutter. SPRING SHUNT Flexible shunt maintains a high conductivity path between the column and the lower cap to ensure continuous low impedance contact during arrester operation. It also assures optimum discharge char ac ter is tics. LOADING SPRING Extra-long lower loading spring ensures high pressure contact. BRASS CAP Brass end cap is magneformed around molded-in sealing rings on rubber shank to provide a tight, weatherproof seal and ground lead connection. GROUND LEAD #4 AWG flexible copper stranded woven ground lead (36 inches long) reliably carries current to ground during voltage surges. Figure 1. Cutaway illustration shows 25 kv Class metal oxide varistor elbow surge arrester. Operation Installing a M.O.V.E arrester at the end of a radial system or at both ends of an open point on a loop system pro vides excellent over volt age protection. The addition of a second M.O.V.E. arrester at the mid-point on a rotatable feedthru insert provides optimum protection. 600 A feeder circuits can be protected with elbow arresters installed on Eaton's Cooper Power series T-OP II and BT-TAP Separable Connector Systems. Standards The M.O.V.E. arrester complies with the latest revisions of IEEE Std C62.11-2005 standard "IEEE Standard for Metal Oxide Surge Arresters for AC Power Circuits" and IEEE Std 386-2006 standard "Separable Insulated Connectors for Power Distribution Systems Above 600 Volts." Installation Eaton's M.O.V.E. arresters can be installed or removed from energized bushings with a clampstick. No special tools are required. The arrester is placed on a 200 A inter face by using a clampstick. Refer to Service InformationS235-55-1, Standard M.O.V.E. and POSI-BREAK M.O.V.E. Elbow Arrester Installation Instructions for more details. Production tests Tests conducted in accordance with IEEE Std 386-2006 and Std C62.11-2005 standards: Partial Discharge Extinction Voltage Level AC 60 Hz 1 Minute Withstand AC 60 Hz Watts Loss Tests conducted in accordance with Eaton requirements: Physical Inspection Periodic Dissection Arrester Assembly: Voltage at 1 ma Periodic Fluoroscopic Analysis Production tests of mov blocks A complete production test program ensures a quality product. Each metal oxide varistor receives a series of electrical tests. Quality is demonstrated by a series of destructive tests performed on every batch of varistors. Listed are the tests performed on the varistors: 100% Physical Inspection 100% Discharge Voltage test 100% V 2 1mA/cm 100% Leakage Current at 80% of V 2 1mA/cm Voltage (Watts Loss) Batch High-current, Short-duration test Batch Thermal Stability test Batch Aging test 2

Metal oxide varistor elbow (M.O.V.E.) surge arrester Catalog Data CA235025EN General application recommendations The rating of an arrester is the maximum power frequency line-to-ground voltage at which the arrester is designed to pass an operating duty-cycle test. Table 2 provides a general application guide for the selection of the proper arrester rating for a given system voltage and system grounding configuration as outlined in the IEEE Std C62.22 standard application guide. Under fault conditions and other system anomalies, higher voltages can be experienced by the arrester. To ensure that the arrester ratings will not be exceeded, Eaton's application engineers are available to make recommendations. The following information is normally required: 1. System maximum operating voltage. 2. System grounding conditions. A. For four-wire circuits, grounding conditions depend upon whether the system is multi-grounded, whether it has a neutral impedance and whether common primary and secondary neutrals are used. B. For three-wire circuits, grounding conditions depend upon whether the system is solidly grounded at the source, grounded through neutral impedance at the source transformers or ungrounded. Consult your Eaton representative to have your individual system application needs studied. Protective characteristics The protective characteristics of the M.O.V.E. surge aresters are shown in Table 1. Table 1. Electrical Ratings and Characteristics Duty Cycle Voltage Rating (kv) MCOV (kv) Equivalent Front-of- Wave (kv crest)* Maximum Discharge Voltage (kv crest) 8/20 µs Current Wave 1.5 ka 3 ka 5 ka 10 ka 20 ka 3 2.55 11.0 9.0 9.7 10.4 11.4 13.0 6 5.1 22.0 18.0 19.4 20.8 22.7 26.0 9 7.65 31.7 26.0 28.0 30.0 32.8 37.4 10 8.4 33.0 27.0 29.1 31.2 34.1 38.9 12 10.2 41.5 33.9 36.6 39.2 42.9 48.9 15 12.7 51.8 42.4 45.7 49.0 53.6 61.1 18 15.3 62.2 50.9 54.9 58.8 64.3 73.4 21 17.0 66.0 54.0 58.2 62.4 68.2 77.9 24 19.5 77.0 63.0 67.9 72.8 79.6 90.8 27 22.0 87.2 71.4 76.9 82.4 90.1 103.0 30 24.4 97.1 79.5 85.7 91.8 100.0 115.0 33 27.0 108.0 87.8 95.1 102.0 112.0 127.0 36 29.0 116.0 95.3 103.0 110.0 120.0 137.0 * Equivalent front-of-wave voltage is the expected discharge voltage of the arrester when tested with a 5 ka current surge cresting in 0.5 µs. Table 2. Commonly Applied Voltage Ratings of M.O.V.E. Surge Arrester Commonly Applied Arrester Duty-cycle (MCOV) System Voltage (kv rms) Voltage Rating (kv rms) on Distribution Systems Nominal Voltage Maximum Voltage Range B 4-Wire Multigrounded Neutral Wye 3-Wire Low Impedance Grounded Delta and 3-Wire High Impedance Grounded 2.40 2.54 3 (2.55) 4.16 Y/2.40 4.40 Y/2.54 3 (2.55) 6 (5.1) 6 (5.1) 4.26 4.40 6 (5.1) 4.80 5.08 6 (5.1) 6.90 7.26 9 (7.65) 8.32 Y/4.80 8.80 Y/5.08 6 (5.1) 9 (7.65) 12.00 Y/6.93 12.70 Y/7.33 9 (7.65) 12 (10.2) 12.47 Y/7.20 13.20 Y/7.62 9 (7.65) or 10 (8.4) 15 (12.7) 13.20 Y/7.62 13.97 Y/8.07 10 (8.4) 15 (12.7) 13.80 Y/7.97 14.52 Y/8.388 10 (8.4) and 12 (10.2) 15 (12.7) 13.80 14.52 18 (15.3) 20.78 Y/12.00 22.00 Y/12.70 15 (12.7) 21 (17.0) 22.86 Y/12.00 22.00 Y/12.70 15 (12.7) 21 (17.0) 23.00 24.34 30 (24.4) 24.94 Y/14.40 26.40 Y/15.24 18 (15.3) 27 (22.0) 27.60 Y/15.935 29.255 Y/16.89 21 (17.0) 30 (24.4) 34.50 Y/19.92 36.51 Y/21.08 27 (22.0) 36 (29.0) 46.00 Y/26.60 48.30 Y/28.00 36 (29.0) 3

Catalog Data CA235025EN Metal oxide varistor elbow (M.O.V.E.) surge arrester Temporary overvoltage (TOV) capability The temporary overvoltage (TOV) capability of the M.O.V.E. arrester is shown in Figure 2. Performance test characteristics 2.2 2 The M.O.V.E. surge arrester consistently withstands the following design tests as described by IEEE Std C62.11 standard: Duty Cycle: 22 current surges of 5 ka crest 8/20 µs waveshape. High-Current, Short-Duration Discharge: 2 current surges of 40 ka crest 4/10 µs waveshape. Low-Current, Long-Duration Dis charge: Per Unit MCOV 1.8 1.6 1.4 1.2 IEEE Std. C62.22 standard Minimum Standard M.O.V.E. Arrester (Ref. Catalog Section 235-65) and POSI-BREAK M.O.V.E. Arrester 20 current surges of 75 A crest 2000 µs rectangular wave duration. Following each of these tests, the arresters remain thermally stable as verified by: Continually decreasing power values during a thirty minute power monitoring period. No evidence of physical or electrical deterioration. 1 0.01 0.1 1 10 100 1000 10000 Time (Seconds) Figure 2. Temporary overvoltage curve. No prior duty at 85 C ambient. 4

Metal oxide varistor elbow (M.O.V.E.) surge arrester Catalog Data CA235025EN Table 3. M.O.V.E. Surge Arrester Selection Chart IEEE Std 386 standard Interface 15 kv Class 25 kv Class 35 kv Class Interface 1A Large Interface Duty Cycle (kv) MCOV Rating (kv) Dimensions in./(mm) A B C Catalog Number 3 2.55 8.5 (216) 7.0 (178) 7.9 (201) 3238018C03M 6 5.1 8.5 (216) 7.0 (178) 7.9 (201) 3238018C06M 9 7.65 8.5 (216) 7.0 (178) 7.9 (201) 3238018C09M 10 8.4 8.5 (216) 7.0 (178) 7.9 (201) 3238018C10M 12 10.2 8.5 (216) 7.0 (178) 7.9 (201) 3238018C12M 15 12.7 8.5 (216) 7.0 (178) 7.9 (201) 3238018C15M 18 15.3 8.5 (216) 7.0 (178) 7.9 (201) 3238018C18M 9 7.65 8.5 (216) 7.0 (178) 7.9 (201) 3238019C09M 10 8.4 8.5 (216) 7.0 (178) 7.9 (201) 3238019C10M 12 10.2 8.5 (216) 7.0 (178) 7.9 (201) 3238019C12M 15 12.7 8.5 (216) 7.0 (178) 7.9 (201) 3238019C15M 18 15.3 8.5 (216) 7.0 (178) 7.9 (201) 3238019C18M 21 17.0 8.5 (216) 7.0 (178) 7.9 (201) 3238019C21M 18 15.3 13.3 (338) 11.2 (284) 10.4 (264) 3238020C18M 21 17.0 13.3 (338) 11.2 (284) 10.4 (264) 3238020C21M 24 19.5 13.3 (338) 11.2 (284) 10.4 (264) 3238020C24M 27 22.0 13.3 (338) 11.2 (284) 10.4 (264) 3238020C27M 30 24.4 13.3 (338) 11.2 (284) 10.4 (264) 3238020C30M 33 27 13.3 (338) 11.2 (284) 10.4 (264) 3238020C33M 36 29 13.3 (338) 11.2 (284) 10.4 (264) 3238020C36M S3 C Ordering information To order a M.O.V.E. surge arrester kit, de ter mine the arrester Maximum Continu ous Op er at ing Voltage (MCOV) rating for the intended ap pli ca tion using Table 2 and specify the ap pro pri ate catalog number from Table 3. Contact your Eaton sales engineer in your location for applications not listed. A B 2.2" (55 mm) Voltage Class S3 15 kv 4.2" (107 mm) 25 kv 4.2" (107 mm) 35 kv 4.7" (120 mm) Figure 3. Dimensional information of M.O.V.E. arrester (refer to Table 3). Note: Dimensions given are for reference only. 5

Catalog Data CA235025EN Metal oxide varistor elbow (M.O.V.E.) surge arrester Additional information Refer to the following reference literature for additional information: B235-11029, Make the Move to the Highest TOV Rated Elbow Arrester in the Industry CA650078EN, 200 A 15 kv Class Loadbreak Rotatable Feedthru Insert Catalog Section CA650077EN, 200 A 25 kv Class Rotatable Feedthru Insert Catalog Section CA650017EN, 600 A 15 kv Class T-OP II Deadbreak Connector Catalog Section CA650059EN, 600 A 25 kv Class T-OP II Deadbreak Connector Catalog Section S235-55-1, 15, 25, and 35 kv Class Standard M.O.V.E. and POSI-BREAK M.O.V.E. Arrester installation Instructions R235-68-1, Elbow Arrester Cross Reference Tables 6

Metal oxide varistor elbow (M.O.V.E.) surge arrester Catalog Data CA235025EN This page is intentionally left blank. 7

Catalog Data CA235025EN Metal oxide varistor elbow (M.O.V.E.) surge arrester Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Cooper Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2015 Eaton All Rights Reserved Printed in USA Publication No. CA235025EN Eaton is a registered trademark. All other trademarks are property of their respective owners. For Eaton's Cooper Power series product information call 1-877-277-4636 or visit:.