SIRIUS ACT PROFINET. Ethernet for your push buttons, indicator lights and switches. usa.siemens.com/sirius-act. Industrial Controls

Similar documents
PROFINET the Industrial Ethernet standard. Siemens AG Alle Rechte vorbehalten.

PROFINET. The leading. Industrial. Ethernet. Standard. The Benefits of PROFINET

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd

Linear Motion and Assembly Technologies Pneumatics Service. Industrial Ethernet: The key advantages of SERCOS III

Understanding Device Level Connection Topologies

Hirschmann Networking Interoperability in a

Introduction to PROFIBUS and PROFINET

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

PROFIBUS AND MODBUS: A COMPARISON

SIMATIC Safety Workshop

Configuring PROFINET

IO-Link an integral part in the next industrial revolution known as Industry 4.0

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

SPPA-T3000 Control System The Benchmark in Controls

Square D Model 6 Motor Control Centers

PROFINET IO Diagnostics 1

Using installed Fieldbus Wiring to carry Ethernet Communications

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

PROFINET Diagnostics Software and Tools

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents

Vorlesung Kommunikationsnetze Fieldbus Systems

Efficient remote access to machines and plants with SIMATIC

PROFIBUS/PROFINET System design

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

PROFINET with STEP 7 V13 SIMATIC. PROFINET PROFINET with STEP 7 V13. Preface. Documentation guide 1. Description 2. Parameter assignment/addressing

White paper The future role of ethernet and the trend to decentralised control solutions

19 Comparison of Ethernet Systems

154 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local

CPUs - CPU PN/DP

Automation Unit TM 1703 ACP Flexible automation and telecontrol

PROFIBUS fault finding and health checking

EtherCAT the Ethernet fieldbus

Industrial Communication

Permissible ambient temperature Operation Storage, transport

Realize your full potential with the new version of SIMATIC PCS 7

Understanding Device Level Connection Topologies

What ensures easy and fast wiring?

GE Intelligent Platforms. PACSystems High Availability Solutions

Siemens AG SCALANCE X - Industrial Ethernet Switches

SIMATIC S It s the interplay that makes the difference. SIMATIC Controller. Answers for industry.

Power network telecommunication

EtherCAT Cutting Costs with High-speed Ethernet

Lecture 4 Profibus. Urban Bilstrup Urban.Bilstrup@ide.hh.se

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Leveraging the Industrial Internet of Things (IOT) to Optimize Renewable Energy

SIMATIC VS720A and VS720-S series Intelligent cameras with PROFINET

Introduction to the Actuator Sensor-Interface

Industrial Networks & Databases

Software INTERACT. MachineLogic. The Shortest Distance Between Man and Machine

High Speed Industrial Ethernet for Semiconductor Equipment

SICAM PAS - the Key to Success Power Automation compliant with IEC and your existing system

Remote I/O Network Determinism

Siemens ENEAS solutions for substation automation and protection

Security & Surveillance Cabling Systems

FOUNDATION Fieldbus High Speed Ethernet Control System

Chapter 9A. Network Definition. The Uses of a Network. Network Basics

Power over Ethernet technology for industrial Ethernet networks

CONTROL LEVEL NETWORK RESILIENCY USING RING TOPOLOGIES. Joseph C. Lee, Product Manager Jessica Forguites, Product Specialist

HARTING mcon 1000 Introduction and features

Components for industrial communication. Lenze Global Drive Providing the connection

Non-Stop Manufacturing Excellence. Automotive. Answers for industry.

HARTING econ 3000 Introduction and features

Introduction to Ethernet

ABB PSPS Erich Steinmann; Generator control-2013

Connectivity solutions for transport automation

TIA Portal vs Studio 5000

Wireless Technologies for Industrial Applications

Remote Maintenance with Security Appliances FL MGuard RS2000 and RS4000. Economic and Reliable Service

PROFINET AND IT. Table of Contents EXECUTIVE SUMMARY MOTIVATION NEW TRENDS IN AUTOMATION

Using Industrial Ethernet Networks for PROFInet

Storage Area Network

The CP FO provides access to different communication services of the PROFIBUS bus system:

Introduction Media converters

PROFINET. Design Guideline

Cut down your costs, increase your productions efficiently with the knowledge of PLC s Siemens technology. SITRAIN TM THAILAND Page 1 of 14

Chapter 5. Data Communication And Internet Technology

Easy, flexible, efficient

Fiber Distributed Data Interface

PROFINET Network Diagnostics at Audi Neckarsulm, Germany

PROFINET The Solution Platform for Process Automation

S7-1500/S7-1500F Technical Data

1. Communication Network Requirements

Remote Serial over IP Introduction on serial connections via IP/Ethernet

Workshop PROFINET in Process Automation. Intern / Siemens AG Alle Rechte vorbehalten.

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

S7-1500/S7-1500F Technical Data

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

Module 5. Broadcast Communication Networks. Version 2 CSE IIT, Kharagpur

CN1047 INTRODUCTION TO COMPUTER NETWORKING CHAPTER 1 BASIC CONCEPTS OF NETWORK

Technical Information POWER PLANT CONTROLLER

Continuous Availability for Power Plant Automation. Dr. Rainer M. Speh. Chief Technology Officer

OPTICAL FIBER repeaters/ isolators

Safety Nonstop for airports. Seamless safety throughout all areas

S and STEP 7 Basic V10.5

Siemens automotive portfolio strategy is derived from customer challenges

System 800xA Networks Control. Monitor. Communicate.

Transcription:

usa.siemens.com/sirius-act SIRIUS ACT PROFINET Ethernet for your push buttons, indicator lights and switches When it comes to communication, SIRIUS ACT is a strong performer. Besides the standard wiring, you can also connect these push buttons, indicator lights and switches directly to the controller via AS-Interface or with IO-Link. With our new SIRIUS ACT PROFINET technology, you can now directly interface to PROFINET and bring all the features of Ethernet down to the field level. Reduced wiring time and effort, minimized error source and flexibility for future modifications are the main drivers that push industrial communication systems down towards the sensors and actuators in the field. SIRIUS ACT PROFINET is the easy way to connect your push buttons and pilot devices to the TCP/IP world. Learn how to use PROFINET in your application in this paper. Industrial Controls

PROFINET introduction PROFINET is the open, Ethernet-based communication solution for the superior control level. With its decisive advantages of flexibility, efficiency and performance, PROFINET opens up new ways for you to increase productivity. Flexibility Industrial Wireless LAN PROFINET supports wireless communication with Industrial Wireless LAN, thus opening up new application fields for your push buttons and signaling devices. For example, technology that is susceptible to wear, such as contact wires, can be replaced. Furthermore, the use of automated guided vehicle systems and mobile HMI devices becomes possible. In addition to data exchange with PROFINET, the IWLAN connection can also be used for additional communication via standard services such as TCP/IP. Thus, moving machine parts can be wirelessly integrated in a plant just like transport systems. The reliability of wireless communication is essential for this. To ensure that this can be guaranteed even in harsh industrial environments, Siemens offers a broad portfolio of wireless components for a wide variety of applications, including support in calculating radio fields in the planning phase. Safety PROFINET supports the proven PROFIsafe safety profile and it also allows wireless safety-related communication. The PROFIsafe profile, which has been tried and tested with PROFIBUS and which permits the transmission of standard and safety-related data on a single bus cable, can also be used with PROFINET. No special network components are required for fail-safe communication, standard switches and standard routers can be used without restrictions. In addition, fail-safe communication is equally possible via Industrial Wireless LAN (IWLAN). Flexibility Efficiency Performance Industrial Wireless LAN Safety Flexible topologies Web tools Expandability Device / network diagnostics Easy cabling Fast device replacement Ruggedness / stability Speed High precision Large quantity structures High transmission rate Media redundancy Fast start-up 2

PROFINET is the open, Ethernet-based communication solution for the superior control level. Flexible topologies PROFINET permits flexible network topologies and optimum machine and plant planning. PROFINET also enables the use of star, tree, and ring topologies in addition to the linear topology characterized by the established fieldbuses. This results in a high degree of flexibility in the planning of machines and plants. The PROFINET network can be installed without specialist knowledge and meets all requirements relevant to the industrial environment. Open standard Due to its openness, PROFINET provides the basis for a uniform automation network and allows the easy integration of existing systems. PROFINET, the open vendor-independent standard (IEC 61158/61784), is supported by PROFIBUS and PROFINET International (PI). It stands for maximum transparency, open IT communication, network security and simultaneous real-time communication. Due to its openness, PROFINET creates the basis for a uniform automation network in the plant to which all of the machines and devices can be connected. The integration of existing parts of the plant, using PROFIBUS for example, can also be achieved without any problems through the use of gateways Web tools Since PROFINET supports TCP/IP, it permits the use of standard web services such as web servers in the field device. Regardless of the tool used, information from the field level can be accessed at any time and from nearly anywhere using a commercially available Internet browser. This facilitates commissioning and diagnostics considerably. Users can decide for themselves how much openness to the IT world they will permit for their machine or plant. Efficiency Device / network diagnostics PROFINET provides an exceptionally powerful means of diagnosing faults in machines and plants. By retaining the proven device model of PROFIBUS, the same diagnostics information is also available on PROFINET. In addition, Siemens offers useful tools for structuring machine and plant architecture, suitable for each project phase. Easy cabling In industrial environments, high demands are placed on the installation of the cabling. In addition, industrial-grade networks must also be set up without special knowledge, without errors, in the shortest possible time. Siemens offers FastConnect, a system that meets all these demands. The time spent for connecting the terminal devices is minimized thanks to the easy installation using only a single tool. Furthermore, installation errors are avoided by a practical color coding. Both copper cables and glass fiber-optic cables can be assembled on-site in this way. 3

Fast device replacement PROFINET devices are identified via a name that is assigned in the configuration. When replacing a defective device, a new device can be recognized by the IO controller by means of topology information and have a name automatically assigned to it. An engineering tool is therefore not required when replacing devices. This mechanism can also be used during the initial commissioning of a complete plant. Quick commissioning is possible for series of machines. Ruggedness / stability An automation network must be able to withstand most external sources of interference. The use of switched Ethernet prevents faults in one section of the network from influencing the entire plant network. PROFINET enables the use of fiber-optic cables especially for areas that are critically sensitive to EMI. Performance Speed Fast motion control applications need precise and deterministic data exchange. This is implemented thanks to isochronous drive controls using Isochronous Real-Time (IRT). With IRT and isochronous mode, PROFINET supports high-speed, deterministic communication in which the different cycles of a system (input, network, CPU processing and output) are synchronized, even with TCP/IP communication operating in parallel. PROFINET s short cycle times make it possible to increase the productivity of machines and plants, and to ensure product quality through high precision. High precision PROFINET stands for maximum precision with significantly increased performance not only in communication, but integrated in the entire system thanks to isochronous mode. Machines with several axes are a challenge and are becoming increasingly important. To increase throughput, it is necessary to integrate more drives in a machine. At the same time, these must always work in perfect coordination with each other. PROFINET with IRT provides the basis for fast and precisely synchronized communication for motion control systems. Large quantity structures Previous limitations in the scope of the machines and systems to be implemented can be easily overcome through the use of PROFINET. With PROFINET, up to 256 field devices can now be managed by one SIMATIC controller. In a network, several controllers can interact with their assigned field devices. Mechanisms such as I-Device allow the simple set up of hierarchical controller structures. The number of field devices per PROFINET network is practically unlimited, the entire band of IP addresses is available. High transmission rate By using Ethernet in full duplex mode, PROFINET achieves a significantly higher transmission rate than previous fieldbuses. Thanks to this, both the process data and other plant data can be transferred via TCP/IP without any problems. PROFINET easily comes up to industrial requirements such as simultaneous transmission of fast IO data and large volumes of data for other parts of the application. Due to PROFINET mechanisms, even the transfer of large volumes of data that are common for video-data does not compromise speed and precision of IO data transfer. Media redundancy Higher plant availability can be achieved by means of a redundant installation (ring topology). The media redundancy can be implemented both with the help of external switches and direct via integral PROFINET interfaces. Reconfiguration times of 200 ms can be achieved with the Media Redundancy Protocol (MRP). In the case of an interruption to the communication in only one part of the ring installation, this means that a plant standstill is prevented and the necessary servicing and repair work can be carried out without time pressure. Fast start-up The Fast Start-Up function allows rapid start-up of PROFINET devices that are connected to SIMATIC controllers. The communication connection between the controller and the device is established in less than a second. Thus, in modular plants, individual parts of the plant can be coupled and decoupled in minimal time. PROFINET for SIRIUS ACT The new SIRIUS ACT PROFINET system brings the features of PROFINET to your pilot device applications. The system consists of a gateway that is assembled to the standard holder of the SIRIUS ACT line, and one safe slot connected to 20 standard slots via a flat cable. The standard SIRIUS ACT actuators can easily be snapped onto the SIRIUS ACT PROFINET slots without the need of addressing and without the need for any special tools. As a result the system can be assembled quickly and actuators can be replaced easily. How to assemble? 4

21 slots Device test without PLC is no problem The SIRIUS ACT PROFINET devices can be tested without PLC or software knowledge. Just push the button on the front side of the device slot and a LED on the backside indicates if everything is assembled correctly. How to check the system without PLC? Front side Press the button Backside Wiring failures and defect devices can also be identified by the indicating LEDs on the back side of the device. How to detect failures? No failure! Defect module! Wiring failure! The system set-up is saved on an EEPROM in the gateway that can be replaced manually. Consequently defect gateways can be replaced simply by a new gateway using the old EEPROM and the existing system set-up. There is no specific software know-how needed, therefore this task can be done by everyone. How to change modules in the field? Old Gateway New Gateway EEPROM 5

Siemens Offers You the Right Solution for Your Application AS-Interface, IO-Link and PROFINET coexist in the Totally Integrated Automation (TIA) world of Siemens. Depending on your application, you can select and combine the communication system according to your individual needs. For applications with a low information volume per device, for example, digital sensors and actuators such as push buttons and a medium or high number of network participants in the switching cabinet or in the field, the AS-Interface bus system is the system of choice. Applications that require higher information volume per device for small quantities, for example, SIRIUS ACT ID key-operated switch in the switching cabinet or in the field, the point-to-point connection system IO-Link suits the best. For highly demanding applications, Siemens also offers you the Ethernet-based PROFINET system. Information volume per device (diagnostics, parameterization, identification) Conventional wiring IO-LINK AS-Interface PROFINET Functionalities/ quantities Small quantities (P2P) Medium quantities Large quantities 6

TIA Totally Integrated Automation AS-Interface, IO-Link and PROFINET coexist in the Totally Integrated Automation (TIA) world of Siemens. Field bus / Network Systems PROFINET AS-Interface Kind of the system Data volume Dimension Network system Max. 256 devices (w/o router) Any topology Real-time Synchronous Field bus Max. 62 devices Any topology Max 1440 bytes I Max 1140 bytes O Parameters Diagnosis date Generic data (TCP/IP) 4 I / 4 O Parameters Diagnosis data Copper/segment: max. 100m Optical/segment > 15 km 100m (standard), up to 600m Infrastructure cabling Fiber optic Coax Twisted pair IWLAN Power supply 2-core data cable Unshielded Safety Yes Yes Supply of devices Typically No, but possible with PoE (power over Ethernet) Power supply via data cable resp. via sensor/actuator connection SIRIUS ACT IO-Link Intelligent pointto-point wiring system 32 bytes I/O Parameters and diagnosis data 20m 3-core data cable Unshielded No Power supply via cable resp. sensor/actuator connection Wiring Conventional wiring Point-to-point 1 I / 1 O 600m 1-3 core data cable Unshielded (digital) Shielded (analog) No (add. wiring) Ext. supply 7

Published by Siemens Industry, Inc. 2016. Siemens Industry, Inc. 100 Technology Drive Alpharetta, GA 30005 For more information, please contact our Customer Support Center. Phone: 1-800-241-4453 E-mail: info.us@siemens.com usa.siemens.com/sirius-act Order No. CCFL-SAPRO-0216 Printed in U.S.A. 2016 Siemens Industry, Inc. Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features which may not always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested performance features are binding only when they are expressly agreed upon in the concluded contract.