Electrically operated Type NR oil switch

Similar documents
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Type MOST oil switch. Technical Data Contents. Effective October 2013 Supersedes March 2000

Distribution Voltage Regulators

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

Secondary Unit Substations

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

Bolted contact switches. Pringle switches

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

S&C TripSaver Dropout Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

OVR-3SP Recloser with PCD Control Style Guide 1VAL SG March 30, 2009 Revision B

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

S. C. Electric Cooperative s Specification for a Three-Phase, Padmounted URD Transformer (Revised 12/2014)

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

When power interruptions happen.

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

picomax The Pluggable Connection System

Model 1756 Test Lead Kit

Diesel Engine Driven Generators Page 1 of 6

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

IRRIGATION PUMPING Table of Contents - Section 900

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Current Limiting Protector For Systems rated kV and continuous currents through 5000A.

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Type K current limiting fuse canister Technical information and installation guide

Type MG-6 Multi-Contact Auxiliary Relay

Power Capacitor Units for improved power quality

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

EDS / EFS Series Control Stations

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Electrical Grounding. Appendix C

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Cable/Conduit Conversion

Bypass switches. Type B-1 and type B-2. Answers for energy.

EDS / EFS Series Control Stations

Medium Voltage Electrical Distribution

Installation Instructions for EHD, EDB, EDS, ED, EDH, EDC, FDB, FD, HFD, FDC, HFDDC Circuit Breakers and Molded Case Switches

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

CITY OF LOS ANGELES CALIFORNIA

Installation Guide Content for P250xV-240 microinverters

Lightning Arresters P KVA P KVA. Description & Installation

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

LVA Take Offs in Bid Manager

Model Number Electrical Compatibility Module Connector Type. M LL-S22 60 cell PV module MC-4 Type 2 Locking

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

DISTRIBUTION SYSTEMS INDEX NOV 06 SECTION 2. Detroit Ann Arbor Mt. Clemens Port Huron

AC Module Installation Guide Content

Medium voltage VCP-W MR2 (integral racking)

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

RAY-MAX Integrated Solar Power Strip

Quick Reference Guide Euro Style Terminal Blocks

Comparison of NEMA and IEC schematic diagrams

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

How To Build A Germany Power Plant

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Directory chapter 04

Multi-tap Transformers

Variable Transformers Product Design & Engineering Data

8146/5 Series Breaker Panelboards

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Installation, Operation and Maintenance Instructions Viper -S Solid Dielectric Reclosers Three Phase, Vacuum Recloser.

Generator DoCKInG StatIonS

No Phone Line II-48 System

MCC Ratings. Voltage Rating

Low Voltage Transformers Sealed, General Purpose, Dry Type

Hyperlinks are Inactive

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

SUPPLEMENT TO SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS

WHOLESALE DIRECT INC WEST 65TH STREET

TRAILER WIRING AND COMMUNICATION SYSTEMS Systèmes de Communication et Filage de Remorques Sistemas de Comunicación y Cableado para Caravanas

Applications. Remote Display Mounting Kits

Customer Substation Manual 08/05/02

June July 18, of 7

MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

INSTALLATION INSTRUCTIONS

Circuit Breakers. NRC Series. NRC Series

Transcription:

Power Capacitors Catalog Data CA230007EN Supersedes 230-60 October 2013 COOPER POWER SERIES Electrically operated Type NR oil switch General Eaton offers its Cooper Power series Type NR oil switch for switching inductive and capacitor currents, to meet the requirements of a wide range of applications. This switch is an electrically operated, single-phase switch. The switch also includes an operating handle for switch position indication or manual operation. The normal operation of this switch is managed with an electric motor requiring low-voltage input. Eaton offers two options for the electric motor, either 120 Vac, 60 Hz or 240 Vac, 60 Hz. The switch operation can be managed remotely, via electrical or electronic controls, or manually at the installation site when needed.

Catalog Data CA230007EN Electrically operated Type NR oil switch LIFTING STRAP convenient for hoisting entire switch or for lifting mechanism from tank BUSHING TERMINALS accept No. 8 through 2/0 copper or aluminum conductors, either vertically or horizontally BUSHINGS wet-process porcelain with light-gray glaze. Munsell Gray 70 ACTUATOR HOUSING completely weatherproof, houses the motor-driven mechanism for electrically opening and closing the switch SLEET HOOD protects manual operating handle: switch data permanently affixed on nameplate OPERATING HANDLE allows hookstick operation and serves as contact position indicator STATIONARY CONTACTS have large current exchange surfaces and durable arcing tips, accessible for easy inspection or cleaning O-RING GASKET in confined assembly provides weatherproof head-tank seal Figure 1. Untanked Type NR oil switch. The Type NR oil switch is a single-phase device for use on distribution circuits. Compact design makes these switches ideal for use on capacitor banks, especially pole-top installations. These switches are electrically operated and can be controlled by various electrical or electronic devices. An operating handle, which also serves as a contact position indicator, is provided for manually opening and closing the switch. NNote: The Type NR oil switch may not be manually closed into a faulted line. The making current rating to these switches applies to electrical operation only. Capacitor bank switching The standard Type NR single-phase oil switch is rated at 15.0 kv / 95 kv BIL and is capable of switching three-phase capacitor banks up to 3600 kvar on 14.4 kv systems; with three (3) switches controlled by customer. Choosing the 125 kv BIL option enables switching solidly grounded capacitor banks up to 6400 kvar on multigrounded wye systems up to 14.4 / 24.9 kv; with three (3) switches controlled by customer. The 22.0 kv / 125 kv BIL version of the Type NR oil switch can switch solidly grounded three-phase capacitor banks up to 2700 kvar on 20 / 34.5 kv multigrounded-wye systems; with three (3) switches controlled by customer. Table 1. Summary of Ratings Switch Type * General purpose duty switches are rated for both capacitive and inductive current switching applications. Operation Application Maximum Operating Voltage (kv) NR 15.0 200* General Purpose Duty NRV 22.0 60 Rated Switching Current (A) With switch contacts closed, selecting the "OPEN SWITCH", or similar, position in the switch controls energizes the switch open contacts on the electric motor. Through a gear and lever system, this releases a toggle which allows pre-loaded opening springs to snap open the switch contacts; loads a heavy spring in preparation for a closing operation; positions selector switch contacts so that only the closing circuit can subsequently be energized; and interrupts the electric motor operating current when the first three functions have been completed. The opening circuit must remain energized for 4.0 seconds. Similarly, selecting the "CLOSE SWITCH", or similar, position in the switch controls energizes the switch close contacts on the electric motor. This releases the closing spring to close switch contacts and load opening springs; positions selector switch contacts for the subsequent opening signal, then interrupts the operating electric motor current. The closing circuit must remain energized for 0.5 seconds. 2

Electrically operated Type NR oil switch Catalog Data CA230007EN Table 2. Ratings and Specifications Standard 15 kv with 17" Creepage 15 kv with 125 kv BIL 22 kv Maximum Design Voltage, kv 15.0 15.0 15.0 22.0 Nominal Operating Voltage, kv 2.4-14.4 2.4-14.4 2.4-14.4 20.0 Basic Insulation Level (BIL), kv 95 95 125 125 60 Hertz Withstand Voltage, kv Dry, One Minute Wet, Ten seconds Continuous Current Rating, Amps 200 200 200 60 Load Interrupting Ability (Inductive), Symmetric Amps 75-100% power factor 50-75% power factor < 50% power factor Maximum Capacitive Current, Amps (parallel bank-max) 200 200 200* 60* High Frequency Transient Current, Amps 12000 12000 12000 12000 Transient Frequency, Hz 6000 6000 6000 6000 High Frequency Damping Factor.40-.55.40-.55.40-.55.40-.55 Momentary Rating, Amps asym. 9000 9000 9000 9000 Short Time Current Amps 1/2 second,sym. 1 second, sym. Close and Latch Rating, Amps asym. 9000 9000 9000 9000 *The 125 kv BIL switch and the 22.0 kv switch are rated for single bank switching only. 35 30 200 100 50A 6000 4500 35 30 200 100 50A 6000 4500 42 36 200 100 50A 6000 4500 60 50 60 60 60 6000 4500 Table 3. Electrical Data (Control) Rating Nominal operating voltage (50/60 Hz only) (Vac) 120 240 Operating voltage range (Vac) 95-130 190-260 Closing-motor current (A) 1.9.7 Switch response time, opening (sec) 4.0 4.0 Switch response time, closing (sec) 0.5 0.5 3

Catalog Data CA230007EN Electrically operated Type NR oil switch Ordering information When ordering the Type NR electrically operated oil switch specify the Voltage Rating from Table 4. The basic Type NR oil switch is designed with a maximum operating voltage of 15.0 kv L-L with a continuous current rating of 200 A. The Type NRV oil switch is designed with a maximum operating voltage of 22.0 kv with a continuous current rating of 60 A. Table 4. Basic NR and NRV Oil Switches Nominal/ Maximum Voltage (kv) Continuous Current (A) Type NR Oil Switch 14.4/15.0 200 95* Type NRV Oil Switch 20.0 60 125 * 125 kv BIL option available for standard NR oil switch Switch BIL (kv) Control voltage requirements Specify the Type NR motor control voltage from Table 5. The Type NR oil switch is supplied with a 120 Vac motor control voltage as standard. Table 5. NR / NRV Motor Control Voltage 120 Vac Actuating Motor (Standard) 240 Vac Actuating Motor Insulation and creep requirements Specify the NR oil switch insulation level and porcelain insulator creep using Table 6. The NR oil switch is designed with 95 kv BIL insulation level as a standard option with a porcelain bushing having 12 inches of creep. The 95 kv BIL insulation level is only available in the NR oil switch. The NRV oil switch has an insulation level of 125 kv BIL and a porcelain bushing with 17.0" of creep as a standard offering. Table 6. NR / NRV Switch BIL & Bushing Creep* Rating (kv) BIL (kv) Bushing Creep (in) NR Oil Switch 15.0 95 12.0 NR Oil Switch 15.0 95 17.0 NR Oil Switch 15.0 125 16.0 NRV Oil Switch 22.0 125 17.0 *Reference Figure 4 on page 9 for outline dimensions of the extra creep bushing" Specialized tank requirements Specify the required NR tank option from Table 7. The standard tank is manufactured from a mild formed steel and painted to protect against the environment. There are available options for zinc plating and stainless steel tanks for highly corrosive and salt-fog contaminated environments. Table 7. NR / NRV Tank Options Switch Rating (kv) 15.0 Standard Tank 22.0 15.0 Stainless Steel Tank 22.0 15.0 Zinc Plated Tank 22.0 Surge protection requirements There is an available option for a factory-installed 120 Vac low voltage surge arrester to protect the motor control circuit from damaging effects of lightning. The arrester rating is determined by the motor control voltage. Contact the factory if a 240 Vac low voltage arrester is required. Table 8. NR / NRV Low Voltage Arrester None (Std) 120 Vac Surge Arrester (Factory Installed) * Determined by motor control voltage Auxiliary switch requirements Specify the Auxiliary switch from Table 9 if necessary for the switching application. The Auxiliary switch is a SPDT switch, which allows the user to remotely obtain the close or open position of the Type NR oil switch. Table 9. NR / NRV Auxiliary Switch None (Std) Auxiliary Switch 4

Electrically operated Type NR oil switch Catalog Data CA230007EN Hold switch requirements Specify the Hold switch from Table 10 if necessary for the application. The close or open signals supplied to the Type NR oil switch must be applied for a minimum of 4.5 seconds. Specify the Hold switch option from Table 10 if the capacitor switching application requires a signal for less than 4.5 seconds. The close or open signal has to be applied for 1 second for proper operation of the Type NR oil switch. Table 10. NR / NRV Hold Switch None (Std) Hold Switch Receptacle assembly requirements Specify the type of receptacle from Table 11 for the switching application. The receptacle assemblies are mounted in the bottom of the actuator housing and provide a convenient, weather-proof connection to switch the control circuits. Receptacles are supplied with 5-pin. 3-conductor or 6-pin, 6-conductor configurations. Reference Figure 2 for 5-pin or 6-pin receptacle orientations. Consult the factory for additional receptacle options. Table 11. Factory-wired Receptacles 5-pin/3-conductor receptacle for standard three-wire control 6-pin/6-conductor receptacle for auxiliary switch * Consult factory for available receptacle options KEY D E A E F A C B D C B 5-pin Receptacle 6-pin Receptacle Figure 2. Receptacle assembly schematic. 5

Catalog Data CA230007EN Electrically operated Type NR oil switch Mating plug & conductor cable requirements Specify the type of mating plug and conductor cable configuration and length from Table 12 if required for the switching application. 5-pin plugs accommodate up to 12 AWG wire and 0.375-0.500 inch O.D cables to allow connection to the 5-pin receptacle. 6-pin plugs accommodate up to 16 AWG wire and 0.500-0.625 inch O.D cables to allow connection to 6-pin receptacles. The number of conductors tabulated for the receptacles in Table 12 above indicates the number of pins wired to the actuator terminal strip. Mating plugs are available as an accessory and should be ordered separately. Consult the factory for additional mating plug and conductor cable options. Table 12. Mating Plug and Conductor Cable Options Catalog Number 5-Pin Mating Plug CCR010P1 5-Pin / 3-Conductor Cable (6 ft) CCR003P6 5-Pin / 3-Conductor Cable (8 ft) CCR003P8 5-Pin / 3-Conductor Cable (10 ft) CCR003P10 5-Pin / 3-Conductor Cable (12 ft) CCR003P12 5-Pin / 3-Conductor Cable (14 ft) CCR003P14 5-Pin / 3-Conductor Cable (16 ft) CCR003P16 5-Pin / 3-Conductor Cable (18 ft) CCR003P18 5-Pin / 3-Conductor Cable (20 ft) CCR003P20 5-Pin / 3-Conductor Cable (22 ft) CCR003P22 5-Pin / 3-Conductor Cable (24 ft) CCR003P24 5-Pin / 3-Conductor Cable (26 ft) CCR003P26 5-Pin / 3-Conductor Cable (28 ft) CCR003P28 5-Pin / 3-Conductor Cable (36 ft) CCR003P36 6-Pin Mating Plug CCR009P1 6-Pin / 6-Conductor Cable (6 ft) CCR006P6 6-Pin / 6-Conductor Cable (8 ft) CCR006P8 6-Pin / 6-Conductor Cable (10 ft) CCR006P10 6-Pin / 6-Conductor Cable (12 ft) CCR006P12 6-Pin / 6-Conductor Cable (14 ft) CCR006P14 6-Pin / 6-Conductor Cable (16 ft) CCR006P16 6-Pin / 6-Conductor Cable (18 ft) CCR006P18 6-Pin / 6-Conductor Cable (20 ft) CCR006P20 6-Pin / 6-Conductor Cable (22 ft) CCR006P22 6-Pin / 6-Conductor Cable (24 ft) CCR006P24 6-Pin / 6-Conductor Cable (26 ft) CCR006P26 6-Pin / 6-Conductor Cable (28 ft) CCR006P28 6-Pin / 6-Conductor Cable (36 ft) CCR006P36 * Consult factory for additional Conductor Cable options Wildlife protector requirements Select required wildlife protectors based on the Type NR switch being ordered for the application. Wildlife protectors protect the energized terminals of the Type NR switch from incidental contact from wildlife, tree branches or line crews performed routine maintenance of overhead equipment. Wildlife protectors must be ordered in a quantity of 2. Table 13. Wildlife Protectors for Terminal Bushings Catalog Number None (Std) Wildlife Protectors (95 kv BIL Only)* CCM32A1 Wildlife Protectors (125 kv BIL only)* CCM33A1 * Must be ordered in a quantity of (2) Mounting option requirements Select the Type NR oil switch mounting method from Table 14. The standard Type NR switch is supplied with an integral bracket, which is used for pole-mounting or capacitor rack applications. A NEMA - style bracket is available for cross-arm applications. Table 14. Mounting Options Catalog Number None (Std) NEMA X-Arm Brkt HA00039 6

Electrically operated Type NR oil switch Catalog Data CA230007EN Standard Type NR Oil Switch Catalog Number Configuration The standard Type NR and NRV configurations are provided below. If you need Engineered To Order (ETO) models, please contact your Eaton representative for details. Type NR (15.0 kv) CCM17B2-G Type NRV (22.0 kv) CCM75B2-G Table 4-Switch Type NR (15 kv) Table 4-Switch Type NRV (22.0 kv) Table 5-Control Motor 120 Vac (Std) Table 5-Control Motor 120 Vac (Std) Table 6-BIL & Creep* 95 kv BIL (15.0 kv Only) Table 6-BIL & Creep* 125 kv BIL Table 7-Tank Options Standard Tank Table 7-Tank Options Standard Tank Table 8-LV Surge Arrester Table 8-LV Surge Arrester Table 9-Auxiliary Switch Table 9-Auxiliary Switch Table 10-Hold Switch Table 10-Hold Switch Table 11-Receptacle 5 -Pin / 3-Conductor (Std) Table 11-Receptacle 5 Pin / 3-Conductor (Std) Table 12-Plug & Cable Table 12-Plug & Cable Table 13-Bird Guards W/O Bird Guards (Std) Table 13-Bird Guards W/O Bird Guards (Std) Table 14-Mounting Options Table 14-Mounting Options *Reference Figure 3 on page 8 for NR oil switch outline dimensions *Reference Figure 5 on page 10 for NRV outline dimensions 7

Catalog Data CA230007EN Electrically operated Type NR oil switch 5.62 2.75 13.88 #8 SOLID TO #2/0 STRD BUSHING TERMINAL CABLE RANGE GROUND CONNECTOR #10 SOLID TO #2 STRD 7.38 8.25 4.5 12.00 SUPPORT LUG FOR 5/8 POLE BOLT 20.13 1.25 5.5 8.0 2.0 10.75 1.25 4.75 1.5 Ø1.38 HOLE Ø7.12 Ø.44 HOLES (4) Ø1.06 OPENING FOR FACTORY-WIRED RECEPTACLE Figure 3. Outline dimensions of 95 kv BIL Type NR oil switch with standard bushings, (15.0 kv Rating ONLY). 8

Electrically operated Type NR oil switch Catalog Data CA230007EN 5.62 2.75 13.88 #8 SOLID TO #2/0 STRD BUSHING TERMINAL CABLE RANGE GROUND CONNECTOR #10 SOLID TO #2 STRD 7.88 8.25 4.5 14.25 SUPPORT LUG FOR 5/8 POLE BOLT 1.25 5.5 22.38 2.0 10.75 1.25 8.0 4.75 1.5 Ø1.38 HOLE Ø7.12 Ø.44 HOLES (4) Ø1.06 OPENING FOR FACTORY-WIRED RECEPTACLE Figure 4. Outline dimensions of 95 kv BIL Type NR oil switch with 17" creepage bushings, (15.0 kv Rating ONLY). 9

Catalog Data CA230007EN Electrically operated Type NR oil switch 1.31 5.62 2.75 13.88 #8 SOLID TO #2/0 STRD BUSHING TERMINAL CABLE RANGE GROUND CONNECTOR #10 SOLID TO #2 STRD 8.25 12.63 1.2 4.5 14.5 13.3 SUPPORT LUG FOR 5/8 POLE BOLT 1.25 5.5 22.5 10.75 8.0 2.0 1.25 4.75 Ø1.38 HOLE Ø7.12 1.5 Ø.44 HOLES (4) Ø1.06 OPENING FOR FACTORY-WIRED RECEPTACLE Figure 5. Outline dimensions of 125 kv BIL Type NR oil switch (15.0 and 22.0 kv). 10

Electrically operated Type NR oil switch Catalog Data CA230007EN 11

Catalog Data CA230007EN Electrically operated Type NR oil switch Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Cooper Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2015 Eaton All Rights Reserved Printed in USA Publication No. CA230007EN Eaton is a registered trademark. All other trademarks are property of their respective owners. For Eaton's Cooper Power series Type NR oil switch product information call 1-877-277-4636 or visit:.