R-Matte Plus-3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Similar documents
Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

Continuous Insulation Using Polyiso Wall Sheathing

Atlas Roofing Corporation insulating sheathing

Fiberglas, Exterior Wall Thermal Insulation

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

GreenGuard Housewrap Installation Guide

s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Underwriters Laboratories Testing Information

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Additions and Alterations

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

Renovating Your Basement

EcoTouch Insulation with PureFiber Technology

DEFAULT HEAT LOSS COEFFICIENTS

Roof Insulation Building. Energy. Environment friendly e-library

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

CHAPTER 7: Building Systems ROOFING SYSTEMS

STANDARD OPEN PATIO COVER

GYPSUM BOARD AND PLASTER

Asphalt Shingle Application Requirements

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

Presented by: Jennifer Doyle, P.E., RRC, LEED AP

AUTHORIZATION TO MARK

COMMERCIAL BUILDING APPLICATIONS

Building Envelope Design. ComfortBoard IS. Exterior Insulated Sheathing for High-Performance Residential Wall Systems

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2B Energy & IAQ (2009) Related TEK: 6-1B, 6-11, 6-12C INTRODUCTION

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

Heating Load Calculation

Insulation Products For Residential Thermal Applications ROXUL. Better Best ROXUL. Solutions For Residential Thermal Applications.

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2C Energy & IAQ (2013) Related TEK: 2-5B, 6-1C, 6-4B, 6-11A, 6-12C, 6-12D, 6-12E

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

Ver. 2. Guide to. Inspecting Residential Brick Veneer

R-Value and Densities Chart

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Fire Resistance of Brick Masonry

Performance of 8 Passive House Envelopes in Cold Climates

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

Cost Comparisons for Common Commercial Wall Systems

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

Avoiding Air Barrier Pitfalls

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

How To Make A House Safe

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

2009 IECC Update. Scope. Content. International Energy Conservation Code

How To Repair A Boat Landing Deck With A Boat Bed

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

COMMONLY USED RESIDENTIAL BUILDING CODES

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

Housing Fact Sheets. Insulation Check-Up

An American Institute of Architects (AIA) Continuing Education Program Credit for this course is 1 AIA/CES HSW Learning Unit

LAYING BLOCK AND BRICK

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

PIMA Technical Bulletin #115. The High R Roof: Guidelines for Energy-Efficient Roofing and Re-Roofing. What is a High R Roof?

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

Superform Products Ltd.

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

LP OSB Sheathing & Structural 1 Sheathing

The Case for Cross Laminated Timber: Part 2

March 14, Installation of Bay, Bow and Garden Windows

Common Problems with Walls

Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

application instructions

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.

Commercial Wall Designs using Continuous Insulation (CI) under Cladding BCBEC Vancouver and Victoria May 25 th & 26 th, 2011

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

Protecting Your Home from Wind Damage

Detached accessory structures that contain no conditioned floor area are exempt.

PART 1 GENERAL 1.1 SECTION INCLUDES

Transcription:

Insulation for the Building Envelope ROOF WALL SPECIALTY PRODUCT DESCRIPTION Rmax R-Matte Plus-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded to reinforced aluminum foil facers on each side. While one side of the board has a reflective surface, the other side has been coated to have a non-reflective white matte surface. R-Matte Plus-3 utilizes a CFC-, HCFC- and HFC-free blowing agent that has zero Ozone Depletion Potential (ODP) and negligible Global Warming Potential (GWP). This insulation is suitable for use in walls and ceilings in new construction for commercial, residential, agricultural and industrial buildings and in thermal retrofit construction within existing buildings. COMPLIANCES ASTM C289 Type I, Class International Building Code (IBC) Section 2603, Foam Plastic ASHRAE 90. Miami-Dade County Product Control Approved California Code of Regulations, Title 24 Air Barrier Material per ASTM E278 CONSTRUCTION APPLICATIONS Stud walls Cavity walls Masonry walls Exterior stucco Re-siding Vaulted ceilings Attics and crawl spaces INCENTIVE OPPORTUNITIES Reduces energy costs Contributes toward LEED credits Offers tax credits, where applicable THERMAL PROPERTIES / PRODUCT DATA R means resistance to heat flow. The higher the R-value, the greater the insulating power. Nominal Thickness Thermal R-Value System R-Value 2 Pcs/Bdl Inches F ft 2 hr/btu F ft 2 hr/btu 0.50 3.2 5.97 96 0.75 5.0 7.77 60.00 6.0 8.77 48.50 9.6 2.37 32 2.00 3. 5.87 24 2.50 6.7 9.47 9 3.00 20.3 23.07 6 3.50 23.9 26.67 3 4.00 27.4 30.7 2 4.50 3.0 33.77 0 Thermal values are determined by using ASTM C58 test method at 75 F mean temperature on material conditioned according to PIMA Technical Bulletin No. 0. 2 Includes the ASHRAE assigned 2.77 R-value of a ¾ dead-air space against the reflective foil side of R-Matte Plus-3 in a typical wall assembly. Additional thermal R-values can be found on the insert to this document. R-Matte Plus-3 is shipped in bundles that are approximately 48 inches high and wrapped in plastic for easy handling. Visit www.rmax.com for a complete list of thicknesses and packaging information. TYPICAL PHYSICAL PROPERTIES Physical properties shown are based on data obtained under controlled conditions and are subject to normal manufacturing tolerances. Property Test Method Results Density, Overall, Nominal ASTM D622 2.0 pcf Compressive Strength ASTM D62 20 psi Flame Spread, Core 2 ASTM E84 75 or Less Smoke Developed, Core 2 ASTM E84 < 450 Water Vapor Transmission ASTM E96 < 0.3 perm Water Absorption ASTM C209 < % Vol. Dimensional Stability ASTM D226, 7 days, 58 F, 98% rh Service Temperatures < 2% Linear Change -40 F to +250 F Also available in 25 psi upon request. Less than is only available at 6psi. 2 Flame spread and smoke numbers are shown for comparison purposes only and are not intended to represent the performance of R-Matte Plus-3 and related components under actual fire conditions. 204-2

APPLICATION / INSTALLATION Board Orientation R-Matte Plus-3 conforms to the physical and thermal properties stated within this data sheet regardless of orientation. On exterior applications, R-Matte Plus-3 is designed to be covered with siding materials of aluminum, vinyl, fiber cement, wood or wood-based products, as well as brick, stone or stucco veneers. The white matte, non-reflective side of the board is installed facing the exterior when the exterior finish is aluminum, vinyl, fiber cement, and wood or wood-based products. The reflective side of the board is installed facing the exterior when the exterior finish is brick, stone or stucco. On interior applications, R-Matte Plus-3 may be installed with either side facing the interior. The ASHRAE Handbook of Fundamentals states that a 3/4 inch dead air space in a typical wall assembly has an R-value of 2.77 when a reflective surface is on one side. This value is in addition to the R-value of the polyiso foam. Therefore, when the R-Matte Plus-3 will be against a dead air space, additional r-value is achieved by facing the reflective side of the board towards the air space. Stud Wall Construction - R-Matte Plus-3 applied to the exterior or interior face of studs, to cover all studs, sills, plates and header constructions, provides a layer of continuous insulation (ci) over details not normally covered by insulation products. It may be secured to the framing or structural sheathing with bugle-head screws, galvanized roofing nails or common nails driven through cap washers. Quality-grade construction adhesives may also be used to secure the R-Matte Plus-3 on interior applications. Exterior facades may include brick/stone veneer, exterior siding and stucco. R-Matte Plus-3 must be covered on the interior with a minimum /2 inch gypsum wallboard interior finish that is mechanically attached. AIR / WATER RESISTIVE BARRIER Cavity Wall Construction (Brick Veneer) - R-Matte Plus-3 is an excellent cavity insulation product fitting between the masonry block and finished brick veneer of any residential or commercial project. It may be secured to the dry face of the masonry block wall with a quality grade construction adhesive. R-Matte Plus-3 can be cut to fit between masonry joint reinforcements placed to tie the brick veneer to the concrete block back-up and installed horizontally in strips to allow the wall ties to extend beyond the face of the insulation leaving the proper air spaces as required. CMU WALL 6" OR 24" WIDTHS AVAILABLE TO FIT BETWEEN MASONARY WALL TIES OR IMPALE INSULATION OVER WALL TIE PENTILES BRICK VENEER (Provide weeps as required) THRU-WALL FLASHING (Metal) BRICK LEDGE Cavity Wall Construction (Brick Veneer) 04 Masonry Wall Construction - R-Matte Plus-3 is applied to either the exterior or interior face of concrete or concrete masonry walls to provide a layer of continuous insulation (ci) over the entire surface. It may be secured to the inside face of a concrete or concrete masonry wall, over or under the furring strips, and covered with a minimum /2 inch gypsum wallboard interior finish. Adhesives, screws or nails may be used to hold the R-Matte Plus-3 in place against the wall temporarily, until the furring strips and gypsum wallboard are installed. The furring strips and gypsum wallboard must be secured with suitable screws or nails. BRICK TIES AS REQ. BRICK VENEER (Provide weeps as required) THRU-WALL FLASHING (Metal) CMU WALL END CAP FURRING 6" O.C. /2" GYSUM WALL BOARD FURRING AT BASE. Stud walls must be properly braced for lateral loads Stud Wall Construction (Brick Veneer) 02 R-MATTE PLUS-3 Exterior Application A.00 Masonary Wall Construction 05 R-MATTE PLUS-3 Interior Application A.00

Exterior Stucco Construction - R-Matte Plus-3 may be used as the insulative sheathing under hard coat stucco finishes. It may be secured to the studs with bugle-head screws, galvanized roofing nails or common-nails driven through cap washers. Cover the R-Matte Plus-3 with a suitable separation layer such as an organic or inorganic felt. Then, attach conventional metal wire lath and expansion joints with appropriate fasteners as dictated by the local Building Code. Rmax does not recommend the direct attachment of stucco, such as Portland cement or polymer-modified types, directly to the face of the insulation product. Consult stucco manufacturers for details. Vaulted Ceiling Construction - R-Matte Plus-3 may be applied to the inside face of the roof rafters in vaulted ceiling construction to provide a layer of continuous insulation (ci) and increase the R-value of the roof. Simply nail the R-Matte Plus-3 to the face of the rafter, cover with a minimum /2 inch gypsum wallboard and finish. ROOF JOIST / RAFTER ORGANIC / INORGANIC FELT METAL LATHE HARD COAT STUCCO METAL FLASHING. Refer to local building codes for requirements on proper ventilation 2. Stud walls must be properly braced for lateral loads according to the requirements of local Building Codes. STUD WALL EXTERIOR WOOD SHEATHING. Stud walls must be properly braced for lateral loads Stucco Construction 06 Re-Siding Construction - R-Matte Plus-3 may be used in retrofit construction provided the existing siding is sound and solidly attached. It is secured with galvanized nails of sufficient length to penetrate the old sidings, sheathings below and at least one inch into the existing wall studs. Then, cover the R-Matte Plus-3 with a suitable new siding of aluminum, vinyl, fiber cement, wood or wood fiber based products. FOUNDATION EXISTING SHEATHING AND SIDING SEE NOTE # AIR / WATER RESISTIVE BARRIER EXTERIOR SIDING METAL FLASHING. Existing siding must be inspected and re-nailed to provide for solid back-up to attach new sheathing and siding materials. Deteriorated or rotted areas of existing siding must be removed and replaced to restore original thickness. 2. Stud walls must be properly braced for lateral loads Attics and Crawl Spaces - R-Matte Re-Siding Plus-3 may Construction be applied to the 03interior R-MATTE PLUS-3 Exterior Application A.00 face of stud walls or roof rafters within attics and crawl spaces to provide a layer of continuous insulation (ci). Simply nail the R-Matte Plus-3 to the framing members and cover with an approved ignition barrier such as 3/8 inch gypsum wallboard or /4 inch wood structural panel, particle board or hardboard. LIMITATIONS Stud Wall & Vaulted Ceiling Construction 07 R-MATTE PLUS-3 Interior Application A.00 R-Matte Plus-3 is not recommended, nor warranted, for use as a commercial roof insulation directly under membrane systems. Consult Rmax Sales for suitable commercial roof insulation products. R-Matte Plus-3 is not a structural panel. It must not be used as a nailing base for any other building products. Furthermore, stud walls insulated with R-Matte Plus-3 must be properly braced for lateral loads according to the requirements of local Building Codes. WARNING DO NOT leave R-Matte Plus-3 exposed. Polyiso foam is an organic material which will burn when exposed to an ignition source of sufficient heat and intensity and may contribute to flames spreading. Installations utilizing R-Matte Plus-3 must be fully protected on the interior side of the building by a thermal barrier such as a minimum of /2 inch gypsum wallboard. Masonry or concrete that is a minimum of one inch thick, plywood that is a minimum of /2 inch thick and wood that is a minimum of one inch nominal thickness may also be recognized as suitable thermal barriers. Consult your local Building Official for specific governing codes and requirements. The interior and/or exterior of the building should be protected with a suitable vapor retarder and/or a water resistive barrier, if required, based on local Building Codes and climate zone. WARRANTY See Rmax Sales Policy for warranty conditions. Rmax does not assume any responsibility or liability for the performance of any products other than those manufactured by Rmax. NOTE: All Rmax products must be tarped, placed on skids and kept dry before and throughout construction.

R-Matte Plus-3 Doing one thing well in so many ways... Rmax is a U.S. owned company that only manufactures polyiso insulation. R-Matte Plus-3 is manufactured in the U.S. and is offered through an extensive distribution network. It is available in standard four foot wide panels, with standard panel lengths of eight or nine feet. Custom lengths are available for special orders. Contact Rmax Sales at your regional Customer Service Center for product availability, pricing information, and your nearest distribution center. Corporate & Technical Rmax Operating, LLC 3524 Welch Road Dallas, Texas 75244-529 Phone: (972) 387-4500 Fax: (972) 387-4673 Email: rmax@rmax.com Web: www.rmax.com Customer Service & Plant Locations Central Region Dallas, Texas (800) 527-0890 Ext. 02 Eastern Region Greer, South Carolina (800) 845-4455 Ext. 56 Western Region Fernley, Nevada (800) 762-9462 Ext. 56 ADDITIONAL THERMAL R-VALUES R means resistance to heat flow. The higher the R-value, the greater the insulating power. According to the ASHRAE Handbook of Fundamentals, the reflective foil facing of R-Matte Plus-3 contributes additional R-value to the overall assembly when installed against a dead air space. For example, ASHRAE assigns a 2.77 R-value to a 3/4 inch dead-air space against a reflective foil in a typical wall assembly. This value is in addition to the R-value of the polyiso foam - see System R-Value below. Nominal Thickness Thermal R-Value System R-Value Inches F ft 2 hr/btu F ft 2 hr/btu Pcs/Bdl 0.50 3.2 5.97 96 0.75 5.0 7.77 60.00 6.0 8.77 48.25 7.8 0.57 38.50 9.6 2.37 32.60 0.3 3.07 30.75.4 4.7 27 2.00 3. 5.87 24 2.25 4.9 7.67 2 2.30 5.3 8.07 20 2.50 6.7 9.47 9 2.75 8.5 2.27 7 3.00 20.3 23.07 6 3.25 22. 24.87 4 3.50 23.9 26.67 3 3.75 25.7 28.47 2 4.00 27.4 30.7 2 4.25 29.2 3.97 4.50 3.0 33.77 0 Thermal values are determined by using ASTM C58 test method at 75 F mean temperature on material conditioned according to PIMA Technical Bulletin No. 0. R-Matte Plus-3 is shipped in bundles that are approximately 48 inches high and wrapped in plastic for easy handling. Visit www.rmax.com for a complete list of thicknesses and packaging information. 204-2

Improving Your Design. For warranties, limitations and conditions refer to Rmax Sales Policy and applicable warranties. All documents are located at www.rmax.com. For technical and sales support, email rmax@rmax.com or call (800) 527-0890. Proudly Made and Engineered in the U.S.A. Rmax Sales Offices and Plant Locations Central: 3524 Welch Road Dallas, Texas 75244 East: 649 South Batesville Road Greer, South Carolina 29650 West: 20 Lyon Drive Fernley, Nevada 89408 Phone: 972-387-4500 Phone: 864-297-382 Phone: 775-575-4849 Fax: 972-387-4673 Fax: 864-234-7548 Fax: 775-575-5035 Toll Free: -800-527-0890 Toll Free: -800-845-4455 Toll Free: -800-762-9462 E-mail us at rmax@rmax.com or visit our website www.rmax.com