INSTRUCTIONS FOR ASSEMBLY AND OPERATION

Similar documents
ELECTRIC INSTANTANEOUS WATER HEATER

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

ELECTRIC CENTRAL HEATING FLOW BOILER

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Overheating limit control

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Meaco 30L and Meaco 40L dehumidifier instruction manual

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

ECOCIAT. Domestic hot water heat recovery unit

INFRARED QUARTZ WALL HEATER

SunMaxx Solar Filling Station Operating Instructions

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

SF15K SF05KSS, SF10KSS

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

HERZ-Thermal Actuators

RE-3 : SOLID TOP RANGE RANGE TOP ONLY


SERVICE SERVICE MANUAL FOR ALDE ELECTRICAL HEATER

Installation Guide. DEVIreg 530. Electronic Thermostat.

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Dehumidifier D 850E. - Instruction manual version 02

Elson 10/15L Unvented Water Heater

COLOR VIDEO DOOR PHONE CDV-71BE/D

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Technical data. Danfoss DHP-A

How To Use A Power Supply On A Powerline 2.2 (Ai)

ASSEMBLED SOCKET-COMBINATIONS

Itho Products for Hot and Boiling water. product-

Emergency lighting units EM powerled

IH E Sigma Island 90

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Installation, operation and maintenance manual TX 35A

Instruction manual for Firstline FCS12000CH

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Cooling system components, removing and installing

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

LK Electric Boiler - 4,5

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

SWIMMING POOL HEAT PUMP Owners Manual

Installation and maintenance instructions. Danfoss Vent

Doc. No: Issue: 1 Date: Aug BTT-02 card printer manual THERMAL TRANSFER CARD PRINTER BTT-02

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Assembly and instructions

Failure code manual. content

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

2KW CERAMIC HEATER DHCER20. User Manual

Calor de Hogar. Av Tecnológico 735, PB. San Salvador Tizatlalli. Metepec, 52172, Edo de México. Teléfono (722) (55)

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

FLEXIT S4 R S6 R S7 R

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

WARNING CANADIAN D.O.C. WARNING

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Residual current socket 30mA Order No.:

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Oil and Coolant Circulating Heating System. Model - OCSM

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

Achat 115MA full-range speaker. user manual

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

S5 EK S5 EP MANUAL FOR USE AND MAINTENANCE. La Spaziale S.p.A.

Electronically Controlled Instantaneous Water Heaters Models: DEX & DBX

GRID TIE INVERTER MANUAL GRID TIE INVERTER SWEA EUROPE FRIENDLY CARE FOR YOUR EXPENSES AND OUR ENVIRONMENT!

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

MOUNTING AND OPERATING INSTRUCTIONS

CoolDrive 5. User s Manual

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

3 IN 1 BATHROOM HEATER

PROXIMITY CARD READERS C-10, C-20, C60, C70

Laddomat Charging unit

Electric Meat Grinder

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

2013 Wireless Video Intercom INSTALLATION GUIDE

User Manual. Video Doorphone CDV-1020AQ

ADM1TE 5/30A DIN rail single phase two wire energy meter

Achieving the impossible

Please read operating instructions carefully before use and keep for further reference.

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

OPERATING INSTRUCTIONS

Please keep these operating instructions in a safe place.

MAGNUM Original Sauna Stove 6.6 kw 9.0 kw 10.5 kw MAGNUM Cenik and Lite Sauna Stoves 6.6 kw 9.0 kw 10.5 kw Use and Installation

Bubble King. User Manual

FIRST STOP SAFETY 1 PAT-IT. Portable Appliance Tester. User Manual. Issue 1.6

MXS 3. MANUAL FULLY CHARGED PULSE, MAINTENANCE CHARGING EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT CHARGE CABLE ERROR LAMP MODE- BUTTON

MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

Please also see 10 golden rules for correct Saniflo installation on

4.3-inch Back-Up Camera

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Portable Air Conditioner

Transcription:

INSTRUCTIONS FOR ASSEMBLY AND OPERATION Flow pressure water heaters type 12H, 15H, 18H, 21H

Before using the heater please read the instructions carefully. In the future it will pay off in the form of failure-free operation for a long time. Flow water heaters series 12H, 15H, 18H, 21H with two-degree hydraulic switch are designed for heating utility water. Warm water can provided to a couple of water drawing points located in different rooms. These heaters are equipped with heating spirals that are directly washed by water. This direct heating process prevents limescale from settling and ensures high efficiency and quick heating of water. The electronic system of the heater is equipped with an air block sensor that decreases to minimum the possibility to damage immersion heaters due to air blocking of the water supply installation. It also gives bigger possibilities in the selection of power for different degrees switching on depending on the amount of flowing water. The device cannot be installed in rooms in which temperature may fall below 0 C, as well as in which there is a risk of explosion. This equipment is not designed to be used by persons (including children) of the limited physical, sensory or mental fitness, unless their use is supervised. Attention must be paid to children so that they would not play with the device. Instructions for assembly Installation as well as start-up of the -H heater should be done by an authorized person in accordance with the instructions included in the Instructions. Any installation works should be done with disconnected power and water supply. Electric installation of the heater should be made pursuant to the binding regulations. The device should be permanently connected to an electrical installation with an earth terminal. Electrical installation should be equipped with a residual circuit breaker with the protection against electric shock, as well as a breaker ensuring the disconnecting of the device from the source of power supply in which the distance between contacts should be not less than 3 mm. 1. To the place in which the heater is to be installed, electrical as well as water installation should be supplied using the assembly template for that. 2. Drill holes and insert expansion plug. 3. After supplying cold water, install the control valve with a filter (pict. 3). 4. Unscrew the located at the bottom of the heater casing screw fastening the casing (pict. 1), take off the cover and disconnect the belt cable by taking out the plug from the socked marked KEYBOARD (pict. 2). 5. Screw the heater to the wall with the fastening screws, having previously led the supply cable through the hole. 6. Check the turning on of the pressure switch. 7. Remove blanking plugs from water connections. 8. Connect the heater to water installation (pict. supply connection marked 9, outlet marked 10) 2

9. Switch on the water feeding the heater and check the watertightness of connections. 10. Connect the heater to the electrical installation as shown on pict. 4. 11. Connect the belt cable by plugging the plug to the socket KEYBOARD (pict.2). 12. Place the casing and screw with the fastening screw. Pict. 1. Casing of the heater 1. Power indicator 2. Button increasing the heating power 3. Button decreasing the heating power 4. The screw fastening the casing Pict. 2. Display plate with belt cable 1. Plug 2. KEYBOARD socket 3. Keyboard plate 3

Pict. 3. Pict. 4. Diagram of electrical installation Start-up In order to remove air from the water installation and the heater prior to turning on electric power, open warm water valve for about 20 seconds. Then turn on the power. After turning on the power all indicators will light. Warm water valve should be opened again. The indicators will go out for about 10 seconds. After that time the device will be in standby. Pulsating light on the power indicator will signal the start of the water heating process, as well as the chosen power. Close warm water valve. The heater will turn off heating signalling that state with the change of the pulsating light of the indicator to continuous. By means of or + buttons, the desired power on the power indicator can be set. 4

Use Setting the heating power is done by pressing one of the buttons on the casing marked with or + signs. Detecting by the heating system bigger flow than the minimum for I power degree will result in switching it on what is signalled with pulsating red light on the power indicator. The drop of the flow below the switching point will result in the switching the heating off, and the pulsating light will change into continuous. Adjustment of temperature of outlet water may be done by changing the heating power. Heating power 1 low temperature of outlet water with low, economical power consumption. Heating power 5 high. As well as by increasing or decreasing the water consumption. Decreasing the water consumption results in the increase of temperature. Increasing - its drop. Depending on the season of the year, the temperature of water feeding the heater will change. Colder water in winter will require stronger heating which will require the setting of higher heating power. Efficiency of warm water depends on the temperature of inlet water. Water temperature at the inlet 12H Water temperature at heater outlet 40 O C 15H 18H 21H 12H Water temperature at heater outlet 50 O C 15H 18H 21H 5 O C 4,9 6,2 7,4 8,7 3,9 4,8 5,8 6,7 10 O C 5,8 7,2 8,6 10 4,3 5,4 6,5 7,6 15 O C 6,9 8,7 10,5 12,1 4,9 6,2 7,4 8,7 Adjusting the heating power 12H 15H 18H 21H Power I/II degree Power I/II degree Power I/II degree Power I/II degree 1 4/6 KW 5/7,5 KW 6/9 KW 7/10,5 KW 2 4/8 KW 5/10 KW 6/12 KW 7/14 KW 3 6/8 KW 7,5/10 KW 9 /12 KW 10,5/14 KW 4 6/12 KW 7,5/15 KW 9/18 KW 10,5/21 KW 5 8/12 KW 10/15 KW 12/18 KW 14/21 KW 5

Czyszczenie filtra wody In a situation when the filter is partially or fully blocked, follow the steps: 1. Disconnect the power supply 2. Unscrew the fastening screw located at the bottom of the casing (pict. 1), then take the casing off holding it in such a distance from the heater so that the belt cable connecting the keyboard with the heater was not stretched, and then disconnect the cable by taking out the plug from the socket marked KEYBOARD (pict. 2). 3. Close the control valve (marked 1) 4. Open the plug of the control valve (marked 2) 5. Take out mesh and magnetic filters (marked 3, 4) 6. Remove dirt 7. Insert filters 8. Close the valve plug. 9. Open the flow on the control valve and check the watertightness of connections. 10. Connect the belt cable to the keyboard plate (pict. 2). 11. Close the casing 12. Perform the air relief of the heater, and then start it according to chapter Start-up. 1. Control valve knob (position: flow closed) 2. Valve plug 3. Magnetic filter 4. Mesh filter Pict. 5. Control valve with a filter 6

Mulfunctioning of the heater Removing the given below causes of mulfunctioning of the heater is not included in manufacturer s warranty. In case when none of the causes occurs, please contact a service point. The indicator of set power does not light: not connected belt cable connecting driver plate with keyboard plate (pict.) defect of the power supply installation of the heater. Too low water flow: blocked water filter too low water pressure control valve closed too much not fully opened main valve. The heater does not heat or barely heats. wrong hydraulic assembly, defect of the electric installation powering the heater too strong flow of water turn down the control valve in the heater. 7

Internal structure of the device Pict. 6. 1. Lower casing 2. Heating unit 3. Air block and flow sensors 4. Thermal switch 5. Pressure switch 6. Network terminals being parts of the pressure switch 7. Hole for inserting the supply cable 8. Power plate with a driver 9. Connection of feedwater (cold) 10. Connection of feedwater (warm) 11. Terminal of the protective cable 8

Pict. 7. Schematic diagram 12H, 15H, 18H, 21H 1 thermal switch 3 driver plate 4 heating unit 5, 6 air block and flow sensors 7 pressure switch PE terminal of the protective cable G1, G2, G3 immersion heaters 9

Technical data heater 12H 15H 18H 21H Rated power kw 12 15 18 21 Supply voltage 400 V 3~ Frequency Hz 50 Maximum power consumption A 17,3 21,6 26 30,3 Minimum cross-section of connection cables Maximum cross-section of connection cables mm 2 4 x 2,5 4 x 2,5 4 x 4 4 x 4 mm 2 4 x 10 Rated current of the circuit breaker A 20 25 32 40 Minimum electrical resistivity of water at 15 O C Ωcm 1100 Pressure of feedwater MPa 0,2 0,6 Minimum flow switching on I degree of power Minimum flow switching on II degree of power l/min 3 3,6 4 4,6 l/min 4,2 5,1 5,7 6,8 Maximum temperature of feedwater O C 20 Water connection G ½ Dimensions (height x width x depth) mm 447 x 235 x 104 Mass kg 3,7 Contents of the packaging -H heater 1 pcs. Control valve 1 pcs. Fastening screws with expansion plugs 3 pcs. Gaskets 2 pcs. Template 1 pcs. Instructions manual 1 pcs. Warranty card 1 pcs. 10

11

12