Sterile Packaging, Storage and Transportation. Tom Stang CRCST, CHL Clinical and Education Manager

Similar documents
THE BASICS OF PACKAGING

Heat Transfer. Condensation. Revaporization

AST Standards of Practice for Packaging Material and Preparing Items for Sterilization

1/22/2012. When is it a good time to learn about sterile processing in your facility? Continuing Education Contact Hours. Learning Objectives

Packaging for Sterilization

STERILIZATION WRAP. STERISHEET user guide for the validation of the packaging THE BACTERIAL BARRIER FOR HUMAN PROTECTION

LOW-TEMPERATURE STERILIZATION IS AN EFFECTIVE MEANS TO

THE BASICS OF STERILIZATION

Sterilization Packaging Systems, Preparation and Loading for Steam Sterilization

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

Caring for Your PleurX Pleural Catheter

DISINFECTION & STERILIZATION INFECTION CONTROL GUIDELINES SECTION 2 CLEANING & PACKAGING

"ADOPTED STANDARDS FOR THE REGULATION OF MEDICAL WASTE" IN HEALTH CARE FACILITIES LICENSED BY THE MISSISSIPPI STATE DEPARTMENT OF HEALTH

UV100A Ultraviolet Air Treatment System

Infection Control in the Dental Practice through Proper Sterilization

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Federal Wage System Job Grading Standard For Laboratory Working, Table of Contents

Body Art Facility Infection Prevention And Control Plan Guideline

Improving the Quality of Surgical Trays. By: Stephen M. Kovach

Steam Sterilization Cycles for Lab Applications

Revised EHS Biosafety. 1 Select appropriate containers/bags for autoclaving.

4. Cryogenic gloves are generally designed to protect the hands from intense cold or heat.

Spandrel Glass Types and Recommendations

Sterile Dressing Change with Tegaderm CHG for Central Venous Catheter (CVC)

Laboratory Biosafty In Molecular Biology and its levels

3. It is recommended that the water supply into the facility can be obtained from two (2) separate water lines if possible.

Scotchgard Multi-Layer Protective Film 1004

FOREWORD. The Plastics Pipe Institute. This Technical Note, TN-30, was first issued in January 2006 and was revised and republished in September 2013.

Thermo Scientific Rotor Care Guide. Protect your rotor investment

Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition)

STANDARD OPERATING PROCEDURES Safe Autoclave Operations

Sun Windows General Information Sun New Construction Window Installation Instructions

Annual Biomedical Waste Code Training

DIY Advanced Dry Bags

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

ReadyKart Mobile Processing Station Instructions for Use

KGI MEDICAL WASTE MANAGEMENT PLAN

GUIDELINES: Aseptic Technique for Rodent Survival Surgeries Surgical Area Animal Preparation 1.

Corrugated Packaging 101

Biological Indicators and

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

Building and Grounds Maintenance Checklist

Bed Cleaning Procedure

Best Practices for Loaner Surgical Instruments

PAINT REMOVAL SYSTEM PAINT REMOVAL SPECIFICATION SAFE WORK METHOD STATEMENT FOR LEAD PAINT REMOVAL

Infectious Waste Management Plan

Acumen Enterprises, Inc.

Choosing the Right Floor Protectors

3 Dual Lock Reclosable Fasteners

Infection Control Risk Assessment Matrix of Precautions for Construction & Renovation

Packaging Perishable Shipments

Packaging Perishable Shipments

FACT SHEET : Using Autoclaves Safely

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

OWNER S MANUAL Table Tennis Table Patent Pending

Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9

CARING FOR WATER DAMAGED PAINTINGS

Integrated Physics & Chemistry Supply List (2010)

ReUSAbLe STeRILIzATION CONTAINeR SySTeM. Validated container system for the DePuy Synthes Companies (Trauma & CMF) instrument and implant sets.

-1- SPECIFICATIONS CONE SETTER PLATFORM ATTACHMENT INDEX

Infection Control Risk Assessment Matrix of Precautions for Construction & Renovation

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

Sample Pharmacy CLEANING AND SANITIZING PROCEDURE P-304.1

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Welcome! Thank you for attending today s meeting, it will begin shortly.

Chemotherapy Spill Response:

THE IDEAL SOLUTION SHELVING. Sales Telephone: Sales Fax:

Introduction: Consumables - Part of the Identification System

Appendix J IBC Biohazard Spill Management Plan

Terminal Cleaning and Protection

Potentially Infectious Medical Waste

IMAGINE trying to paint a picture without a canvas or a

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

Spill Kits and Incidental Spill Response

RAIL ADAPTER SYSTEM DRAFT TC-23-AIMSS CHAPTER DESCRIPTION

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

James M. Pleasants Company

Division 9. SignaFlor Pad and Pour Flooring System

MEDICAL WASTE MANAGEMENT

LiAiSON. Formaldehyde. In This Issue. How does Formaldehyde affect human health?

SANITATION AND PEST CONTROL INSPECTION REPORT INSPECTOR: BUSINESS NAME:

CONTROL METHODS. There are five ways to control the release of asbestos fibers:

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Quality Assurance Calendar Maintenance Responsible Party Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

STANDARD OPERATING PROCEDURES SPILL RESPONSE AND CLEAN-UP OUTSIDE BIOSAFETY CABINET

For Components PIERBURG S.A.

Care and Operation of Your New Windows

Part 2. Overview. Risk management. Workplace health and safety legislation. How should asbestos exposure be managed? Identifying asbestos hazards

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

Department: Manager: Safety Coordinator: Date:

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Aseptic Technique. A GMP/GTP Training Module

Sterilization methods and equipment Lab 1-2

Vinyl Composition Tile Installation System

Biohazardous Waste and Sharps Disposal

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

DUCT CLEANLINESS FOR NEW CONSTRUCTION GUIDELINES

Transcription:

Sterile Packaging, Storage and Transportation Tom Stang CRCST, CHL Clinical and Education Manager

Objectives Describe sterile packaging Discuss packaging materials and their differences Identify acceptable closure methods and their proper uses Describe pack preparations and procedures Identify key factors of sterile storage Discuss proper transportation of sterile products

Packaging A comparison between food packaging and sterile packaging can be drawn Protect contents from contamination Provide a tamper resistant seal Be appropriate for the item being packaged

Objectives of Sterile Packaging

Objectives of Sterile Packaging Allow penetration of the chosen sterilant Compatible with any other requirements of the specific sterilization process such as drying Maintain the sterility of the package contents until it is open Able be opened aseptically (without contaminating the contents)

CS Technician Responsibilities Understand the various packaging materials advantages, limitations, etc. Be able to select the packaging that is most appropriate for each item Apply the selected packaging in a manner that ensures: Success of the sterilization process Protection of the item during storage and transport

Selecting Packaging Material Different types of packaging are needed for different sterilization methods May vary based on package contents Specifically designed for sterilization packaging Approved by the FDA Two types of sterile packaging Reusable Disposable

Packaging Considerations for Steam sterilization Sterilization Withstand temps of 250 F - 275 F (121 C 135 C) Allow for air removal and steam penetration Permit drying of contents and packaging material Ethylene oxide sterilization (EtO, EO) Allow for adequate penetration of gas sterilant and removal of gas residual (aeration) Gas plasma sterilization Able to tolerate a deep vacuum draw without absorbing the sterilant, interrupting the cycle or damaging the contents

Reusable Packaging Material

Reusable Packaging Materials Before the early 1980 s, woven textiles were the reusable packaging materials of choice. However new technologies have increased the choices for sterilization packaging. The standards for manufacturing today s packaging materials have been based on penetration and microbial barrier capability measures for a minimum of 140 thread count. Central Service Technical Manual pg. 240

Textile Packaging Still the packaging method of choice for some healthcare facilities Often driven by costs and/or the environment Some facilities contract with off-site companies to pick up used textile wraps, launder, inspect and return for use Requires more labor Must be laundered and inspected for tears or punctures If damaged, must be discarded or repaired Must be de-linted as needed to minimize the risk of lint entering the sterile pack and field Must be held at room temperature ST79 8.3.1: 68 F - 73 F (20 C - 23 C) at a relative humidity of 30% - 60% for a minimum of two hours prior to sterilization

Woven Textiles Muslin Broad term describing a wide variety of plainweave cotton or cotton/polyester fabrics having minimum 140 threads per square inch. Other woven textiles Duck cloth Twill Barrier cloth Treated barrier fabrics NOTE: Canvas should never be used as a sterile packaging material

Rigid Container Systems Box like structures with sealable and removable lids Made of anodized aluminum, stainless steel, plastic or a combination of these materials Have lids and filters that allow sterilant penetration while providing a microbial barrier Filters may be: Disposable (synthetic spunbond product) Reusable (ceramic filters or a valve system) Consist of an inner basket to hold the instruments The weight of the container should not exceed 25lbs (ANSI/AAMI ST79 8.4.2)

Cleaning and Inspection of Rigid Containers Remove disposable filters or release the filter protector/holder Valve-type closures must be cleaned according to manufacturer s instructions for use (IFU) Interior baskets removed and cleaned Chemical indicators, disposable labels and locks removed Inspect all container system components for proper function Inspect gasket for debris, cuts or tears Inspect valves, filter mechanisms and latches for proper operation Central Service Technical Manual pg. 244

Advantages of Rigid Containers Provide an excellent barrier to microorganisms Easy to use Eliminate waste Protect instruments from damage during processing, storage and transport

Disadvantages of Rigid Containers Safety issues linked to ergonomics A large empty container can weigh 8-9lbs Additional cycle time may be required Impacted as a container s weight increases because of excess condensation Plastic containers may require longer dry time Lack of metal, which produces heat by conduction Additional space is needed for storage Additional labor is needed to clean Additional space is needed in the mechanical washers Sharp edges/corners can injure employees

Disposable Packaging Materials

Disposable Packaging Materials Disposable (non-woven) materials were introduced as engineered fabrics in the 1940 s, and they have made their way into our everyday life. Coffee filters, teabags, vacuum cleaner bags and disposable diapers are all examples of engineered fabrics, which are also referred to as disposable non-woven materials. Central Service Technical Manual pg. 245

Disposable Packaging Materials Popular choice for sterilization Excellent barrier effectiveness Three common types of disposable packaging materials Paper Non-woven wrap Peel pouches

Non-Woven Wrap Commonly referred to as Flat wraps SMS (spunbond-meltblown-spunbond) Polyolefin materials are exposed to high heat and are pressure bonded together to form sheets Most popular flat wrap Designed for single use Available in a variety of sizes and weights Available in single sheet or double sheets Double sheets are bonded together

Paper Papers that contain cellulose can not be used in gas plasma sterilizers Medical grade Generally smooth-surfaced Available in many sizes to accommodate various devices Pouches of medical grade paper specifically formulated for sterilization are also available

Peel Pouches Used for small instruments and lightweight items Two basic types of peel pouches Paper/plastic Typically compatible with steam or EtO sterilization Not compatible with gas plasma sterilization Consists of a paper side and a plastic side Spunbond polyolefin/plastic combination Used for gas plasma sterilization Often referred to as Tyvek pouches Consists of a plastic side and a polyolefin side Both types have the plastic side to allow viewing of contents Sterilization penetration through the non-plastic side

Methods of Packaging Closures

Package Closure Methods The purpose of a package closure (seal) is to seal the package securely, maintain the sterile integrity of the contact area during transport and storage, and prevent resealing if package is opened or if the seal is compromised. Only approved methods of closure should be used to seal a sterile package. There are several types of package closures, and Central Service Technicians must ensure that they use the method that is appropriate for the packaging need. Central Service Technical Manual pgs. 246-247

Do Not Use Pins, staples or other sharp objects Paperclips or binding clips Tapes that are not designed specifically to withstand the rigors of sterilization

Acceptable Closure Methods Indicator tape Heat seals Self-adhesive seals Rigid container seals

Indicator Tape Considered best practice because they are made specifically to withstand sterilization. Will change color after being exposed to the sterilization process Should be used on every package to avoid mixing up processed and unprocessed packages Does not provide proof that adequate sterilization of package contents has occurred

Heat Seals Used for paper/plastic or plastic/plastic seals Follow the IFU for the heat sealer and the packaging manufacturers to ensure appropriate exposure times and temperatures Inadequate exposure times and temperatures may cause inadequate seals Exceeding manufacturers recommendations may cause package damage

Self-Adhesive Seals Do not require heat Adhesive covered with a removable strip at one end of the self-adhesive peel pouch Once removed, the sticky portion of the seal should be carefully folded over opening of the package Care must be taken to avoid gaps, wrinkles or creases that will compromise the seal integrity

Locking Tags Most commonly used with rigid containers Designed to break when the container has been opened Most commonly made of plastic Tamper-resistant Lock in place and must be broken to open the container

Preparation of Package Contents, Wrapping & Labeling

Preparation of Pack Contents Instruments that disassemble All parts should be arranged for easy assembly after the package is opened Instruments that open (scissors, hemostats, etc.) Should be kept in unlocked, open positions to enable the sterilant to reach all parts

Delicate and Sharp Instruments Should be protected while being handled and when assembled for sterilization Use specifically designed holders or tip protectors Protectors must be permeable to the sterilant being used

Package Assembly Instruments are placed on a stainless steel, heat-tolerant plastic or anodized aluminum tray with a perforated or mesh bottom Tray liners (surgical huck towels) may be used to absorb moisture and provide cushion for instruments Non-absorbent silicone liner mats may be used to cushion instruments Include a sterility indicator Peel pouches are not recommended to be used inside instrument trays Gauze squares should not be used as additional packing or wicking material

Peel Pouches Packaging Procedures Tip protectors help to protect the pouch contents and prevent the tips from penetrating the pouch If used, ensure that the material is appropriate for the type of sterilization to be used Instruments should be placed in the pouch so the end of the item to be grasped will be presented first when the pouch is opened Pouches must be sized to properly allow for adequate air removal, sterilant penetration and drying

Flat wraps Sequential Packaging Procedures The package is wrapped twice and is a package within a package Simultaneous The package is only wrapped once Can be two single layer wrappers or special double-layered synthetic nonwoven Both are acceptable recommended practices

Considerations For Wrap Must be large enough to completely contain the contents without leaving excess material Wrap must be snug but not tight If wrap is also being used to create a sterile field, it must be sufficient size to extend at least 6 below the edge of the surface being covered Corner protectors will help in preventing tears in wrap

Packaging Labeling Label information should include: Description of package contents Initial package assembler Lot control number Identification of sterilizer and cycle used Date of sterilization Requesting department or surgeon s name may be included Assigned storage location Standardized abbreviations and terms avoid confusion Slang terms and nicknames should be avoided

Sterility Maintenance, Storage and Transportation

Sterility Maintenance Sterilized packages must maintain their content sterility until they are intentionally opened Traditionally, sterility of a package has been thought of as time-related Joint Commission (JCAHO) and the Association of peri- Operative Registered Nurses (AORN) now recognize that sterility is event related Event-related sterility depends on the quality of the wrapper material, handling procedures, storage and transport conditions

Basic Sterility Concerns Primary conditions that can adversely affect the sterility of a package Moisture and liquid/fluid contamination Dirt, dust and debris Physical damage to the package

Storage Considerations Proper use of stock rotation principles is important to assure that packs with time-sensitive expiration are used before they must be discarded. Sterile Storage areas for sterile supplies located outside of the Central Service department must be included in the quality assurance and infection control audits conducted for the sterile storage area in the department. If satellite storage sites are used, personnel responsible for areas should be trained about requirements of sterility maintenance. Central Service Technical Manual pg. 260

Sterile Storage Areas Must be kept clean All storage units should be cleaned routinely with a hospital approved germicidal agent Cleaning should begin in Sterile Storage and move to assembly and end in decontamination (cleanest to dirtiest) Air supply to the storage area should be as clean and dust-free as possible (usually requires filtration) Room should be under positive pressure with at least 4 air exchanges per hour Temperature should be approximately 75 F (24 C) with less than 70% humidity AAMI/ANSI ST79 8.9.2

Sterile Storage Sterile packages should not be stored near or under sinks 8-10 off the floor 18 below the ceiling or the level of the sprinkler head At least 2 away from exterior walls & windows Located away from heavy traffic and access to the area should be restricted AAMI/ANSI ST79 8.9.2

Sterile Stock Arrangement Packages should be arranged so that they are not crushed, bent or compromised Easy to locate Heavier items should be on the lower or middle shelves Lighter and less cumbersome items can be placed higher First In, First Out (FIFO) system should be followed The goal of proper stock arrangement is to provide minimum pack handling while allowing FIFO rotation

Transportation Transport in covered or enclosed carts Cart shelves with solid bottom construction Follow policies and procedures to maintain cleanliness and proper cart maintenance Lift! Don t pull! Important: watch for expiration date, tears, abrasions, punctures, compromised seals, dirt and moisture Check sterilization process indicator to ensure sterility If any of these adverse conditions are noted, the package should be considered contaminated!

Closing Comment Even the most minor break in protocol can cause great harm to patients.

QUESTIONS

Sources IAHCSMM Central Service Technical Manual, Seventh Edition ANSI/AAMI ST79:2011 ANSI/AAMI ST77

Contact Information Tom Stang Clinical & Education Manager 952.288.2240 tom.stang@keysurgical.com