Thermometer/Soldering Tester

Similar documents
TS1200 Intelligent Lead Free Soldering Station. Operation Manual

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Microwave Meter. Instruction Manual

AOYUE. INT 738H (Centigrade / Fahrenheit switchable) Multi-Function Re-Working System INSTRUCTION MANUAL. Replacement Air Nozzles

Ground Resistance Clamp On Tester

Product Specification

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Model UT713 OPERATING MANUAL

Weller WMRS. Table of contents 1. Important! Description 18 Technical data Commissioning 19

Int863 INSTRUCTION MANUAL. IR Preheating System BASIC TROUBLESHOOTING GUIDE

951SX LONER Temperature Controlled Soldering Station

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Manual Ranging MultiMeter

Hand-held thermometer Model CTH7000

MP-4000 Alarm List (Software version or later)

User Guide. 4 wire Earth Resistance Tester Model GRT300

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

4-Channel Thermometer / Datalogger

AutoRanging Digital MultiMeter

User's Guide. True RMS Industrial Multimeter

SMD Rework Station TABLE OF CONTENTS

Hygro-Thermometer + InfraRed Thermometer Model RH101

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

RS DIGITAL THERMOMETER

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

951SX LONER Temperature Controlled Soldering Station

Ground Resistance Clamp-On Tester

ATL Fuel Level Sender Probes

Maximum value. resistance. 1. Connect the Current Probe to Channel 1 and the Differential Voltage Probe to Channel 2 of the interface.

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

ACL 395 Resistivity Meter

High-output, temperature controlled soldering station. Instruction Manual

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Temperature & Humidity SMS Alert Controller

Unit 7: Electrical devices LO2: Understand electrical sensors and actuators Sensors temperature the thermistor

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

OCSM Series. High Resolution Digital Crane Scale. User Guide

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements

1. SAFETY INFORMATION

OCS-S High Resolution Digital Crane Scale

Model UT201/202: OPERATING MANUAL. Table of Contents

WSD130 SOLDERING STATION

Dyeing Programmer DP - 01

T0118 T2118 T3118. Instruction Manual

Li-ion Rechargeable Battery. Specification

MS9000SAN Rework Station

Physical Specifications (Custom design available.)

ACL 800 MEGOHMMETER OPERATION MANUAL

DISSOLVED OXYGEN METER Model : DO-5509

Portable Air Conditioner

User Guide. Model Insulation Tester / Megohmmeter

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

High-output, temperature controlled soldering station. Instruction Manual

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

High-output, temperature controlled soldering station. Instruction Manual

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

TC-9102 Series Surface Mount Temperature Controllers

Dual Laser InfraRed (IR) Thermometer

Experiment: Series and Parallel Circuits

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

Measuring Insulation Resistance of Capacitors

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Instruction Manual Temp 4/5/6 Temperature Meter Series

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

STERILIZERS, LABORATORY DRYING OVENS

Odyssey of the Mind Technology Fair. Simple Electronics

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

5W HI-POWER LED SPECIFICATION

Detection of Pipe Leaks Connection of Pulse Monitoring System in Thermal Utilities

Gas Custody Transfer Calibration

USB-500/600 Series Low-Cost Data Loggers and Accessories

Purchasing Thermometers

Product Information Sheet UH28CS-12kV Hi Pot Tester

digital fever alert ear thermometer suitable from birth instruction manual


Duct Humidity Transmitter

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Module 1, Lesson 3 Temperature vs. resistance characteristics of a thermistor. Teacher. 45 minutes

For board-to-fpc. Narrow Pitch Connectors (0.35mm pitch)

UT202A Operating Manual. Contents

Compact ph Measuring Instruments

Application Note AN-0994 Maximizing the Effectiveness of your SMD Assemblies

Instruction manual for Firstline FCS12000CH

PORTABLE AIR CONDITIONER

Test equipment for temperature and its reduction

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

li-ion Polymer Battery Specification

VSO MAX HP High Flow Proportional Valve

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Transcription:

Thermometer/Soldering Tester Soldering iron tester useful for daily maintenance of station type soldering irons Tip temperature, leak voltage and tip-to-ground resistance can be easily measured with high accuracy. Extremely fine sensor with high temperature reactivity is incorporated Part No. FG101 Packing List HAKKO FG-101,Fuse,Conduction Wire,Sensor (10 pcs/set),multi-adapter,european Adapter,Ground Clip,Power cord,instruction Manual HAKKO FG-101 should be calibrated regularly as a Meter/Tester. For details, please contact us or the distributors in your country. Model No. Power consumption 2.6W Dimensions 200(W) 50(H) 120(D)mm Weight 1kg Temperature resolution 1ºC Temperature measurement 0-700ºC range Temperature precision ±3ºC (300-600ºC) ±5ºC (other than above) Temperature sensor K (CA)type thermocouple Voltage resolution 0.1mV Voltage measurement range 0-40mV (CA) FG101

Model No. FG101 Voltage precision ± (5% of reading + 1 digit) Registaance resolution 0.1Ω Registance measurement range 0-40Ω Registance precision ± (5% of reading + 1 digit) LCD : 3 1/2digits Display Burnout : -1 MAX HOLD : 'MAX HOLD' is displayed at the lower right of the LCD. Operating environment Ambient temperature/humidity range : 0-40ºC, 20-90%RH (without condensation) Environmental condition Applicable rated pollution degree 2 (According to IEC/UL 61010-1) * Weight (w/ power code) * Temperature sensor (No.191-212 or No.191-212C) can only be used ti measure temperatures below 500ºC. To measure higher temperatures, use an applicable temperature probe. * When a sensor is not attached or it burns out,the alarm symbol of Burnout(-1) is displayed. The same symbol is also displayed when a temperature outside the measurement range is detected. One tester for all your soldering iron maintenance needs. What should you check when doing a daily inspection of your soldering iron? Grounded soldering irons are maintained by inspecting leak voltage, tip-to ground resistance, and tip temperature. Grounded soldering irons cannot be maintained by checking insulation resistance. This method was used in the past in order to find out the level of leak current. What is 'Leak voltage'? Leak current is the current that leaks from the tip to a board or device. Leak voltage is a specific measurement of the level of this current. The leakage can adversely affect delicate devices, so it is necessary to check leak voltage on a daily basis.

What is 'Tip-to-ground resistance'? Most leak current flows from the tip via the ground wire to the outlet ground terminal, and is prevented from affecting the device. Because of this, tip-toground resistance is another important issue that must be checked daily. Why is tip temperature important? As the tip, element cover and other parts oxidize, heat conduction deteriorates and the tip temperature becomes lower. This causes the difficulty of soldering. Therefore, tip temperature should be inspected daily to have better soldering. Maximun current value mesured with HAKKO FG-101 100V-120V Spec 5A 220V-240V Spec 3A Note: HAKKO FG-101 is broken when beyond maximum current value is measured. In addition to traditional features, the FG-101 comes with two new functions: MAX HOLD and AUTO ZERO. MAX HOLD Function Constantly displays the maximum temperature AUTOZERO Function Traditional Features Automatically corrects zero point error of measuring instruments Lead-free sensor Measures leak voltage by True Root Mean Square (TRMS) Highly reliable - Resistant to drift and changes in

temperature * The FG-101 does not come with the Monitor Output function that was included in past models. MAX HOLD Function When the MAX HOLD function is on, the maximum temperature is constantly displayed on the LCD. If the MAX HOLD button is pressed for a short time (less than 1 second) the maximum temperature is updated. If the button is pressed for a long time (1 second or longer) the MAX HOLD function turns off. AUTO ZERO Function The zero point error of measuring instruments can be corrected by simply pressing the AUTO ZERO button and waiting for the display to return to normal. How to measure the tip temperature, leak voltage and tip to ground resistance Do not blow hot air (for example, with the HAKKO FR-802, etc.) directly onto the HAKKO FG-101 to measure the temperature. If the hot air is blown directly onto the tester, the main unit of HAKKO FG-101 itself will be damaged. When using the HAKKO FG-101, plug it into the outlet with a grounding terminal. The HAKKO FG-101 cannot measure the leak voltage and tip to ground resistance of a soldering iron which has no grounding pin. It can measure the leak voltage and tip to ground resistance of a soldering iron which has a plug with grounding pin.

Differenced in the measurement methods according to tip shapes For the precise temperature measurement, place the tip on the measuring point on sensor horizontally. Guaranteed temperature range with the measurement tolerance of ±3 C In general, the optimal temperature range for soldering is 300 C to 500 C, and that for SMD rework system is 300 C to 600 C. The tolerance of ±3 C within the optimal temperature range (300 C to 600 C) is assured. For the temperature range other than the above, the tolerance is not guaranteed but usually stays in the range of about ±5 C. How to measure the soldering tip temperature 1. Press the SELECT button to change the mode display to "TEMP". 2. Put fresh solder on the tip. 3. Place the tip on the temperature measuring point of the sensor.

Place the tip on the temperature measuring point located in the center of sensor. * The way to place the tip on the sensor varies depending on the shape of the tip. 4. Wait until the displayed value is stable and read it. It is not necessary to deduct the room temperature that was displayed when the power was turned ON from the measured temprature. The temperature appearing on the LED display is the actual measured value. [How to place the tip on the temperature measuring point on the sensor] For a precise temperature measurement, place the tip on the measuring point on the sensor horizontally. For the B type, I type and D type, if a tip has standard solder plating, place the center of the solder plated part to the measuring point. For the BC type and C type, if only the tip face is solder plated, place the plated face to the measuring point as shown in the illustration.

How to measure the leak voltage 1. Insert the power plug of the soldering iron to be tested into the receptacle on the HAKKO FG-101. 2. Wait until the temperature of the soldering tip reaches the setting. 3. Press the SELECT button to change the mode display to "mv". 4. Press the AUTO ZERO button and wait until the display returns to normal status. The correction value generated by the AUTO ZERO function is recorded in the main unit. It remains in the memory even when the power is turned OFF, and is valid also in the next

measurement. 5. Clean the soldering tip and put fresh solder on it. 6. Place a tiny bead of solder in the center of the conduction plate and heat the bead until suitable wettability is obtained. Place solder in the center of the conduction plate to ensure contact between the soldering tip and the conduction plate. 7. Wait until the displayed value is stable and read it. How to measure the tip to ground resistance 1. Insert the power plug of soldering iron to be tested into the receptacle on the flank of HAKKO FG-101.

2. Wait until the temperature of the soldering tip reaches the setting. 3. Press the SELECT button to change the mode display to "OHM". 4. Press the AUTO ZERO button and wait until the display returns to normal status. The correction value generated by the AUTO ZERO function is recoreded in the main unit. It remains in the memory even when the power is turned OFF, and is valid also in the next measurement. 5. Clean the soldering tip and put fresh solder on it. 6. Place a tiny bead of solder in the center of conduction plate and heat the bead until suitable wettability is obtained. Place solder in the center of the conduction plate to ensure contact between the soldering tip and the conduction plate. 7. Wait until the displayed value is stable and read it.