1-part elastic joint sealant and multipurpose adhesive

Similar documents
Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

High-performance, 2-part epoxy anchoring adhesive

Elastic, 1-part-polyurethane, liquid waterproofing membrane

Polymeric membrane for roof waterproofing

Low viscosity, solvent free elastic adhesive for wood flooring

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

PRODUCT DATA SHEET Sika Cable System

Sikaflex Sealant Installation. Sika Corporation

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Construction. High Performance polyurethane joint sealant. Description. Specifications Satisfied. Uses. Advantages. Instructions for Use

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Araldite AV 170. Advanced Materials. One component epoxy adhesive. Structural Adhesives. Key properties. Description. Product data.

Division 9. SignaFlor Pad and Pour Flooring System

Waterproofing construction Joints

2-part epoxy textured roller and seal coat

3 Marine Adhesives and Sealants

DL CHEMICALS DECO SNJF PARAFILL PARQUET EXTERIOR TRANSPARENT STRUCTURE

PanelTack. For the bonding of steni Colour type 7 façade panels. steni Colour 7. steni Colour 7

RTV159. RTV157 and RTV159 High Strength Silicone Adhesive Sealants

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

IS800 Series. Technical Data Sheet IS802, IS803, IS808, IS Description. Key Features and Benefits. Typical Physical Properties

Wecryl Waterproofing System under surfacing supplied by others

Crystal Clear Sealant

PanelTack HM. for the bonding of SVK Ornimat SKG

2-part Epoxy primer, levelling mortar and intermediate layer

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

Temperature C Cure time to reach hours LSS > 1MPa minutes

BLACK JACK ALL WEATHER ROOF COATING

Two component epoxy paste adhesive. Ideal for bonding GRP, SMC and dissimilar substrates

SC2000 CEMENT BONDING PROCEDURES

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

WATERPROOFING OF WET ROOMS

Black epoxy paste adhesive system

WELCOME. Recommended Window Installation. 1.5 credits Minnesota Department of Labor and Industry

Construction. Sikalastic -560 Economical and eco-friendly liquid applied roof waterproofing solution. Product Description.

Sikagard -203 W (Steridex)

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

RECOATING AND RENEWING SPF ROOFING SYSTEMS

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Two component epoxy paste adhesive

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

Formwork Direct International Ltd Phone No +44 (0151) Fax no +44 (0151)

Document Library TS Data Sheet M Windo-Weld Super Fast Urethane. Data Sheet. Public

CLEAN 1. Cleaning and Degreasing Agents. Universal cleaning and degreasing agent

Technical Data Sheet February 2014

RTV162. Electronic Grade Silicone Adhesive Sealant

Double Coated Urethane Foam Tapes

RAPTOR TRUCK BED LINER - BLACK

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

WOOD FLOORING ADHESIVES

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

PC-Concrete Injectable Concrete Anchoring and Repair System

3 Single-Coated Foam Tapes

3 Scotch-Seal TM. Polyurethane Sealant 540 Polyurethane Adhesive Sealant 560. Technical Data July, 2008

FIRESTOPPING & SMOKE SEALS

Concrete Resurfacing. System Guide. by Parchem Construction Supplies

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Scotch-Weld. Low-Odor Acrylic Adhesives DP810 DP810 NS. Technical Data June, 2004

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data January, 2010

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

COATING & WRAPPING OF UNDERGROUND PIPING

Retail Price List 2015

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

Solvent Cementing Instructions For Plastic Pipe & Fittings

SIGMACOVER 300. PRODUCT DATA SHEET December 12, 2014 (Revision of November 1, 2013) DESCRIPTION

Mold Preventing I nterior System

3 Scotch-Weld TM. Structural Adhesive Films AF 6 AF 10 AF 13. Technical Data July, 2001

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

SIGMACOVER 280. PRODUCT DATA SHEET December 10, 2014 (Revision of March 1, 2014) DESCRIPTION

Mineral waterproof coating PCI Dichtschlämme

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

4 Product Data Sheets

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

SikaBond Adhesive Systems for Floor Coverings. Innovation & Consistency. since 1910

3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data March, 2002

Minor Cracks in Horizontal Surfaces

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

A. Work on this project shall consist of, but is not limited to, the following:

Tractor Painting Tips

Mapei systems for radiating floor heating with high thermal efficiency

3-part cement and epoxy combination mortar for self-smoothing floor screeds of 3 to 7 mm

SikaProof A Technology

12.1 Schlüter -KERDI-BOARD

Concrete Waterproofing Systems. Integral Protection.

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES

12 POLYURETHANE ADHESIVE (PU 105)

DENSO WATERPROOFING SYSTEMS

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

The BASA Guide to the ISO Classification of Sealants for Building Construction

Transcription:

Product Data Sheet Edition 04.03.2008 Revision no:1 Identification no: 01 05 01 01 005 0 000001 Sikaflex -11 FC + 1-part elastic joint sealant and multipurpose adhesive Construction Product Description Uses Characteristics / Advantages Sikaflex -11 FC + is a one part, moisture curing, elastic joint sealant and multipurpose adhesive based on polyurethane. Suitable for indoor and outdoor applications. Sikaflex -11 FC+ is a joint sealant and multipurpose adhesive therefore suitable for many various fields: Sikaflex -11 FC+ used as a joint sealant for vertical and horizontal joints, soundproofing of pipes between concrete and sheathing. Caulking between partitions, seam sealing, sealing in metal and wood construction, for ventilation construction and many more Sikaflex -11 FC+ used as a multipurpose adhesive. It is suitable for indoor and outdoor bonding of window sills, thresholds, stair steps, skirting boards, base boards, crash protections boards, covering boards, prefabricated elements and many more Sikaflex -11 FC + is: 1-part, ready to use Flexible and elastic Sealant: Bubble-free curing Very good adhesion to most construction materials Good mechanical resistance Good weather and ageing resistance Non sag consistency Adhesive: No need to grout the bonded part Non-corrosive Impact and vibration absorbing 1 1/5

Product Data Form Appearance / Colours Packaging Storage Storage Conditions / Shelf-Life Technical Data Chemical Base Density Skinning Time Curing Rate Joint Dimensions Sag Flow Service Temperature White, grey Brown, black, beige (on request) 300 ml cartridges 600 ml sausages 12 months from date of production if stored in undamaged original unopened containers, in dry conditions and protected from direct sunlight at temperatures between +10 C and +25 C. 1-part polyurethane, moisture curing ~ 1.3 kg/l ~ 90 minutes (+23 C / 50% r.h.) ~ 2 mm / 24h (+23 C / 50% r.h.) Min. width = 10 mm / max width = 35 mm 0 mm, very good -40 C to +80 C Mechanical / Physical Properties Tensile Strength ~ 1 to 1.2 N/mm 2 Tear Strength ~ 8 N/mm 2 Shore A Hardness E-Modulus Elongation at Break Elastic Recovery Resistance ~ 35 after 28 days (+23 C / 50% r.h.) ~ 0.5 N/mm 2 after 28 days (+23 C / 50% r.h.) > 600% after 28 days (+23 C / 50% r.h.) > 80% after 28 days (+23 C / 50% r.h.) Chemical Resistance Resistant to water, seawater, diluted alkalis, cement grout and water dispersed detergent. Not resistant to alcohols, organic acids, concentrated alkalis and concentrated acids, chlorinated (hydro-carbons) fuel. 2 2/5

System Information Application Details Consumption / Joint Design Joints: The joint width must be designed to suit the movement capability of the sealant. In general the joint width must be > 10 mm and < 35 mm. A width to depth ratio of ~ 1 : 0.5 must be maintained. All joints must be properly designed and dimensioned by the specifier and the main contractor in accordance with the relevant standards, because changes are not usually feasible after construction. The basis for calculation of the necessary joint width are the technical values of the joint sealant and the adjacent building materials, plus the exposure of the building, its method of construction and its dimensions. Joints < 10 mm are for crack control and therefore non movement joints. Relevant is the joint width at the time of application of the sealant (guide value of + 10 C). Approximate consumption Joint width 10 mm 15 mm 20 mm 25 mm 30 mm Joint depth 10 mm 12-15 mm 17 mm 20 mm 25 mm Joint length / 600 ml ~ 6.0 m ~ 2.5-3.0 m ~ 1.8 m ~ 1.2 m ~ 0.8 m Joint length / 310 ml ~ 3.0 m ~ 1.5 m ~ 0.9 m ~ 0.6 m ~ 0.4 m Minimum joint width for perimeter joints around windows: 10 mm. Backing: Use only closed cell, polyethylene foam backing rods Substrate Quality Substrate Preparation / Priming Bonding: - In spots: 1 cartridge for 100 x 3 cm spots of Sikaflex -11 FC + (Diameter =3cm; thickness = 0.4cm) - In strips: 1 cartridge for 12 meters of Sikaflex -11 FC + with 5 x 5 mm cross section. On average 0.2-0.6 kg/m 2 depending on bonding area. Clean and dry, homogeneous, free from oils and grease, dust and loose or friable particles. Cement laitance must be removed Non porous substrates: E.g. metals, powder coatings etc. have to be cleaned with a fine abrasive pad and SikaCleaner-205 by using a clean towel / cloth. After a flash off time of at least 15 min, apply SikaPrimer-3 N by using a brush. For PVC use SikaPrimer-215. Porous substrates: E. g concrete, aerated concrete and cementitious renders, mortars, brick, etc. have to be primed with SikaPrimer-3 N by using a brush. Important note: Primers are only adhesion promoters. They neither substitute for the correct cleaning of the surface nor improve their strength significantly. Primers improve long term performance of a sealed joint. For further information refer to the Sika Primer table. 3 3/5

Application Conditions / Limitations Substrate Temperature Ambient Temperature Substrate Moisture Content Dew Point +5 C min. / +40 C max. +5 C min. / +40 C max. Dry Substrate temperature must be 3 C above dew point. Application Instructions Application Method / Tools Sikaflex -11 FC + is supplied ready to use. After suitable joint and substrate preparation, insert Backing Rod to required depth and apply primer if necessary. Insert cartridge into sealant gun and firmly extrude Sikaflex-11 FC into joint making sure that it is full contact with the side of the joint. Fill the joint, avoiding air entrapment. Sikaflex-11 FC must be tooled firmly against joint sides to ensure good adhesion. Masking tape must be used where sharp exact joint lines or exceptionally neat lines are required. Remove the tape whilst the sealant is still soft. Sleek joint with smoothing liquid for a perfect sealant surface. Bonding: After substrate preparation apply Sikaflex -11 FC + in strips or spots on the bonding surface at intervals of a few centimeters. Use hand pressure to set the element to be bonded into position. If necessary, use adhesive tape, wedges, or props to hold the assembled elements together for the initial hours of curing. An incorrectly positioned element can be easily unfastened and repositioned in the first few minutes after application. Apply pressure again. Optimum bonding will be obtained after complete curing of Sikaflex -11 FC +, i.e. after 24 to 48 hours at +23 C for a thickness between 2 to 3 mm. Cleaning of Tools Clean all tools and application equipment with Sika Remover-208 / Sika TopClean-T immediately after use. Hardened / cured material can only be removed mechanically. Notes on Application / Limitations Elastic sealants may not be over painted. Compatible coatings may cover the joint sides to max. 1 mm. The compatibility must be tested according to DIN 52 452-2. Colour deviations may occur due to exposure to chemicals, high temperatures, UVradiation (especially with colour shade white). However a change in colour will not adversely influence the technical performance or the durability of the product. Before using on natural stone contact our Technical Service. Do not use Sikaflex -11 FC + as a glass sealer, on bituminous substrates, natural rubber, EPDM rubber or on building materials which might bleed oils, plastisicers or solvents which could attack the sealant. Do not use Sikaflex -11 FC + to seal swimming pools. Not suitable for joints with water pressure or permanent water immersion. The freshly applied sealant has a smell similar to 'Amaretto' until it has fully cured (benzalehyde). Do not mix with or expose uncured Sikaflex -11 FC + to substances that may react with isocyanates, especially alcohols which are often components within e.g. thinners, solvents, cleaning agents and formwork releasing compounds. Such contact could interfere or prevent the cross linking curing reaction of the material. 4 4/5

Construction Value Base Local Restrictions Health and Safety Information Legal Notes All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. Please note that as a result of specific local regulations the performance of this product may vary from country to country. Please consult the local Product Data Sheet for the exact description of the application fields. For information and advice on the safe handling, storage and disposal of chemical products, users shall refer to the most recent Material Safety Data Sheet containing physical, ecological, toxicological and other safety-related data. The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. Sika Yapı Kimyasalları A.Ş. Deri Org. San. Böl. 2. Yol J 7 Parsel, Aydınlı, Orhanlı Mevkii, 34957 Tuzla, İstanbul, Türkiye Çağrı Merkezi Telefon Faks bilgi@tr.sika.com +90 216 444 74 52 +90 216 581 06 00 +90 216 581 06 99 www.sika.com.tr 5 5/5