BUILDING CODE INTERPRETATION

Similar documents
Number of Sides Required to Have a Handrail

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.


COMMONLY USED RESIDENTIAL BUILDING CODES

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

CITY OF TORONTO. BY-LAW No

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

NRC Canadian Codes Centre. Codes Update. Nedjma Belrechid October 2012

Building Regulations (Northern Ireland) Department of Finance and Personnel protection from impact.

New Ontario Building Code Highlights

The replacement or modification of existing windows shall comply with the following requirements:

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

Stair Layout Guide. Taking You To The Next Level E. 6 th Street Sandwich IL

How To Build A Two Hour Firewall In Calgary

Common ADA Errors and Omissions in New Construction and Alterations

Walking and Working Surface Checklist:

REQUIREMENT 3. Usable Doors

ACCESS AUDIT OF WESTPORT HOUSE

New York City Department of Buildings

Building Regulations Technical Guidance Document K. Stairways, Ladders, Ramps and Guards

SCOPE This guideline applies to all construction projects on Emory University properties, including renovation projects.

Simplified Steel Stair Design for Commercial and Institutional Buildings

February 2014 Alberta Fire Code Page 1 of 5. Fire Safety and Hand Hygiene in Healthcare Facilities

OPTIONAL INFORMATION GUARDING FLOORS, STAIRS, AND OTHER OPENINGS SELF INSPECTION CHECKLIST

BUILDING PERMIT SPECIFICATIONS

Extracts from BUILDING REGULATIONS

St. Michael s Hospital Accessibility Plan

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

Issue ID Description No. of Credits Available. Mandatory Elements Storage of Non-recyclable Waste and Recyclable Household Waste

WALKING-WORKING SURFACES (SLIPS, TRIPS, AND FALLS)

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Common ADA Errors and Omissions in New Construction and Alterations

AUSTRALIAN HUMAN RIGHTS COMMISSION NOTICE OF DECISION ON APPLICATION FOR TEMPORARY EXEMPTIONS: AUSTRALASIAN RAILWAY ASSOCIATION

Ontario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12)

Basement Development Construction requirements for the development of basements in residential dwellings.

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

Residential Decks. Planning and Development Services Department

Chapter 2 MEANS OF ESCAPE

MEANS OF EGRESS CHAPTER 10

ELECTRONIC HEALTH RECORDS AND WRITING SURFACES

Excerpts from the Canadian National Building Code (NBC)

MEANS OF EGRESS CHAPTER 10

RESIDENTIAL WOOD DECKS

CHAPTER 10 MEANS OF EGRESS. User Note: See Preface page iv ("marginal markings" for Chapter 10 reorganization information.)

Approved Document M: Part M Access to and use of buildings Volume 1 dwellings. Consultation draft. August 2014

1998 edition. Protection from falling. collision and impact ONLINE VERSION. The Building Regulations Stairs, ladders and ramps

MEANS OF EGRESS CHAPTER 10

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

ADA Checklist for Polling Places

September 2008 AFC (2) Page 1 of 5. Maximum Size and Aggregate Capacities of Aboveground Storage Tank Systems at Fuel Dispensing Stations

The following symbol denotes a generally compliant condition: The following symbol denotes a generally noncompliant condition:

FIRE AND LIFE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS

Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN

27th session 20 December Resolution A.1045(27) Adopted on 30 November 2011 (Agenda item 9) PILOT TRANSFER ARRANGEMENTS

De Beers Canada Inc. OP 050 SLIPS, TRIPS, FALLS AND PEDESTRIAN SAFETY - SURFACE

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

MEANS OF EGRESS CHAPTER 10

Building Code Clarifications - 7. Fire Resistance

Protection from falling. collision and impact. The Building Regulations edition for use in England* ONLINE VERSION APPROVED DOCUMENT

Guarding Floor and Wall Openings and Holes OSHA Standard

Errata has been identified as follows:

Charter Township of Shelby Harry Reese Building Director

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

- 5 - Table1. Maximum Compartment Volumes

STAIRWAY Building code information for one- or twofamily dwellings and townhomes.

BUILDING REGULATIONS GUIDANCE NOTE NHBC BUILDING CONTROL

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

City of Los Angeles Department of Building and Safety Disabled Access Section COMMERCIAL ACCESSIBILITY PLAN REVIEW LIST JOB ADDRESS CITY ZIP

Format for scrutinising the Hill Station Building Applications ( Current File No /2001-HSBA) The application shall be accompanied by

Access to and use of buildings

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

SAFE ACCESS, LADDERS, FLOOR & WALL OPENINGS, STAIRS AND RAILING SYSTEMS

Kitchen Planning Guidelines With Access Standards

Welcome to the AccessibilityOnline Webinar Series. A collaborative program between the National Network of ADA Centers and the. U.S.

MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal

Ministry of the Environment Decree on accessible building

Certification: Building Plans Examiner. Exam ID: B3

Significant Changes to the 2013 California Building Code Chapter 11B accessibility standards


New York City Department of Buildings

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Residential Deck Safety, Construction, and Repair

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

MEANS OF EGRESS CHAPTER 10

Section 7: Elevators and Lifts. Main Entry Floor Outside the Elevator

17,280 square feet Overview:

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings.

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

Chapter 3 Installing Over-the-Post Railing on an L-Shaped Stair

Drew University Ladder Safety Program Policy and Inspection Procedure Draft 0412

Bath Planning Guidelines With Access Standards

TORONTO MUNICIPAL CODE CHAPTER 629, PROPERTY STANDARDS. Chapter 629 PROPERTY STANDARDS. ARTICLE I Definitions; Application

Stair Parts Installation. Tricks

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address

TOWNSHIP OF TOMS RIVER ZONING OFFICE DECK CONSTRUCTION

How To Protect A Swimming Pool

ORDINANCE NO

Staircase Installation Instructions

Architectural Processing and Inspections for Home Mortgage Insurance

Transcription:

BUILDING CODE INTERPRETATION February 2009 06-BCI-016 Page 1 of 9 DISCUSSION STAIRS IN DWELLING UNITS This STANDATA has been developed to provide further guidance on the requirements for stairs within dwelling units governed by Section 9.8. of the Alberta Building Code. Stairs within a dwelling unit would include stairs between the basement and main floor, stairs serving an attached garage, and stairs between other floors. Requirements for guards, landings and handrails within a dwelling unit are also clarified. The purpose of stair requirements within the Code is to provide for the safe passage of the users of the stairs. STAIR WIDTH Over the years, many designers and safety codes officers have had disagreements as to how the width of a flight of stairs is to be measured. Some felt that the minimum stair width was to be measured from the face of the wall that supports the stairs, while others felt that it was to be measured from the inside surface of the stair stringers. With more architecturally designed staircases that incorporate open risers and are not supported on adjacent walls, the issue becomes even more complicated. Additionally, the concept of projections into the required stair width has been a source of debate. Questions have been raised as to whether a set of spindles is considered to be a handrail support as described in Sentence 9.8.7.6.(1), as well as whether the 100 mm projections are allowed on both sides of a stair, or just one. STAIR CONFIGURATIONS Sentence 9.8.3.1.(2) explicitly states the types of stair configurations that are permitted within a flight of stairs. The effect is to preclude the combination of normal treads and angled treads within a single flight of stairs in configurations such as j-stairs and horseshoe stairs, as shown in Figure 1. Unless stated otherwise, all Code references in this STANDATA are to Division B of the Alberta Building Code 2006. Issue of this STANDATA is authorized by the Chief Building Administrator [Original Signed] Ata R. Khan, MRAIC Alberta Municipal Affairs Safety Services, 16th Floor, 10155-102 Street, Edmonton, Alberta, Canada, T5J 4L4 Safety Codes Council, Suite 1000, 10665 Jasper Avenue, Edmonton, Alberta, Canada, T5J 3S9

J-Stair Horseshoe Stair Figure 1 Stair Configurations LANDINGS IN GARAGES Sentence 9.8.6.2.(2) clearly states that a landing is not required at the of a flight of stairs if the stairs are within a dwelling unit and the door at the swings away from the stairs. Sentence 9.8.6.2.(3) then states that a landing may also be omitted on exterior stairs provided there are no more than 3 risers and the door swings away from the stair (unless there is a screen or storm door with a hold-open device). However, a change that was introduced to Sentence (3) in the Alberta Building Code 2006 makes it very clear that this exemption does not apply to a flight of stairs between an attached garage and the associated dwelling unit. The rationale behind requiring the landing is that a door between a garage and an attached dwelling unit requires a self-closing device, as provided in Sentence 9.10.13.15.(1), and a hazard exists where such a door opens directly onto a flight of stairs. The door could swing closed and impact a child or an individual with impaired mobility, thereby causing the child or individual to fall down the stairs. HANDRAILS Sentence 9.8.7.5.(2) speaks to the ability of a person to be able to grasp the handrail throughout its length, without having anything on the handrail that would cause a person to lose their grip. Sentence (2) permits a handhold on the handrail to be broken only when the handrail is interrupted by newels at changes in direction, but there is no stated exception for landings. This has led some people to believe that a landing connected to a flight of stairs has to contain a handrail. However, the preceding requirement must be read in conjunction with Article 9.8.7.2., which speaks to the continuity of the handrail within the flight of stairs. Sentence 9.8.7.2.(2) permits a handrail to not be continuous Page 2 of 9

when the handrail is interrupted by a landing, so the concept of a continually graspable handrail from the flight of stairs to the landing would not apply in such a case. LOADS ON GUARDS Sentence 9.8.8.2.(4) is very explicit that a guard is permitted to be designed without considering the loads mentioned in Table 9.8.8.2., provided that the design of the guard has been shown to provide effective performance. The question of what constitutes effective performance is, however, very subjective and open to interpretation. CLIMBING PREVENTION With the release of the Alberta Building Code 2006, a new Sentence (2) was added to Article 9.8.8.6. to attempt to clarify what is meant by facilitate climbing, as mentioned in Sentence (1). It was felt that if a guard could be demonstrated to meet one of the conditions listed in Sentence (2), that it was deemed to comply with the concept of not facilitating climbing. However, some safety codes officers and designers have interpreted Sentence (2) to mean that a guard would have to meet all four conditions listed in Sentence (2). Questions have also been raised as to whether or not a safety codes officer can still have the opinion that a guard could still facilitate climbing even though it has met one of the conditions listed in Sentence (2). DEFINED TERMS The words and terms in italics in this STANDATA have the following meanings that are specific to this STANDATA only and are not intended to be used in other contexts: Flight means a continuous series of steps from one landing or floor level to the next landing or floor level, containing not less than three risers. Normal tread means a tread that is constant in depth over its width. Angled tread means a tread that increases uniformly in depth over its width and possesses a minimum required run (See also Winder ). Winder means a tread that increases uniformly in depth over its width but which does not meet the requirements for minimum run specified for a tapered tread. Page 3 of 9

CODE REFERENCES 1. Article 3.4.6.8. states: 3.4.6.8. Curved Stairs 1) Except as permitted by Sentence (2), tapered treads shall not be used in an exit. 2) A curved stair used as an exit shall have a) a handrail on each side, b) treads with a minimum run of 240 mm exclusive of nosings, c) treads that conform to Article 3.4.6.7. where they are measured 230 mm away from the handrail at the narrow end of the tread, and d) an inside radius that is not less than twice the stair width. 2. Sentence 9.8.2.1.(2) states: 9.8.2.1. Stair Width 2) At least one stair between each floor level within a dwelling unit, and exterior stairs serving a single dwelling unit except required exit stairs, shall have a width of not less than 860 mm. 3. Sentence 9.8.3.1.(2) states: 2) Stairs within dwelling units shall consist of a) straight-run flights, b) curved flights, or c) straight runs with winders. 4. Sentences 9.8.4.4.(1) and (2) state: 9.8.4.4. Dimensions for Angled Treads (See A-9.8.4. in Appendix A.) 1) Angled treads in required exit stairs shall conform to the requirements in Article 3.4.6.8. 2) Except as provided in Article 9.8.4.5., angled treads in other than required exit stairs shall have an average run of not less than 200 mm and a minimum run of 150 mm. 5. Sentences 9.8.6.2.(2) and (3) state: 9.8.6.2. Required Landings 2) Where a door at the of a stair within a dwelling unit swings away from the stair, no landing is required between the doorway and the stair. 3) A landing may be omitted at the of an exterior flight serving a secondary entrance to a single dwelling unit, not including entrances from attached garages, provided a) the stair does not contain more than 3 risers, b) the principal door is a sliding door or swings away from the stair, and c) only a storm or screen door, if any, swings over the stair and is equipped with hardware to hold it open. Page 4 of 9

6. Sentence 9.8.7.2.(2) states: 9.8.7.2. Continuity of Handrails 2) For stairs or ramps serving a single dwelling unit, at least one required handrail shall be continuous throughout the length of the stair or ramp, except where interrupted by a) doorways, b) landings, or c) newel posts at changes in direction. 7. Sentence 9.8.7.5.(2) states: 9.8.7.5. Ergonomic Design 2) All handrails shall be constructed so as to be continually graspable along their entire length with no obstruction on or above them to break a handhold, except where the handrail is interrupted by newels at changes in direction. (See Appendix A.) 8. Article 9.8.7.6. states: 9.8.7.6. Projections into Stairs and Ramps 1) Handrails and constructions below handrails, including handrail supports and stair stringers, shall not project more than 100 mm into the required width of a stair or ramp. (See also Articles 9.8.2.1. and 9.8.5.2.) 9. Sentence 9.8.8.2.(4) states: 9.8.8.2. Loads on Guards 4) For guards within dwelling units and for exterior guards serving not more than 2 dwelling units, Table 9.8.8.2. need not apply where the guard construction used has been demonstrated to provide effective performance. 10. Article 9.8.8.6. states: 9.8.8.6. Design to Prevent Climbing (See Appendix A.) 1) Guards required by Article 9.8.8.1., except those in industrial occupancies and where it can be shown that the location and size of openings do not represent a hazard, shall be designed so that no member, attachment or opening will facilitate climbing. 2) Guards shall be deemed to comply with Sentence (1) where any elements protruding from the vertical and located within the area between 140 mm and 900 mm above the floor or walking surface protected by the guard a) are located more than 450 mm horizontally and vertically from each other, b) provide not more than 15 mm horizontal offset, c) do not provide a toe-space more than 45 mm horizontally and 20 mm vertically, or d) present more than a 1-in-2 slope on the offset. Page 5 of 9

11. Sentence 9.10.13.15.(1) states: 9.10.13.15. Doors between Garages and Dwelling Units 1) A door between an attached or built-in garage and a dwelling unit shall be tight fitting and weather-stripped to provide an effective barrier against the passage of gas and exhaust fumes and shall be fitted with a self-closing device. INTERPRETATIONS STAIR WIDTH The width of a flight of stairs shall be measured as the width of the narrowest tread in a stair or flight of stairs, as illustrated in Figure 2. X + Y 100 mm X + Y 100 mm X Y X Y handrail 760 mm handrail support or spindle 760 mm housed stair stringer stair tread stair tread stair stringer minimum required stair width (860 mm) minimum required stair width (860 mm) Figure 2 Minimum Stair Width Note that handrails and constructions below handrails are not allowed to project more than 100 mm into the required stair width (X + Y 100 mm). Therefore, a stair with a projection on one or both sides must provide a minimum clearance width of 760 mm (860 mm 100 mm). If the width of a stair exceeds the required minimum width of 860 mm as required by Sentence 9.8.2.1.(2), then the combined total of projection distances from both sides could then potentially extend beyond the 100 mm limit (X + Y > 100 mm), provided the 760 mm minimum clearance width is maintained. STAIR CONFIGURATIONS Stair configurations that combine normal treads and angled treads within a single flight are not permitted. However, as noted in Sentence (2), a combination consisting of normal treads and winders is permitted within a flight of stairs within a dwelling unit. It Page 6 of 9

would be possible to combine normal treads with angled treads by separating the two flights with a landing. TREAD DIMENSIONS Where a flight of stairs does not form part of a required exit stair, the treads are permitted to conform to Sentence 9.8.4.4.(2), as illustrated in Figure 3. Minimum Average Run to be Measured along the Centerline of the Stairs Minimum Average Run 200 mm Centerline Tapered Treads Minimum Run 150 mm Figure 3 Tread Dimensions LANDINGS IN GARAGES A stair configuration consisting of only one step (equivalent to two risers), as illustrated in Figure 4, does not require a landing between the stair and the doorway into the dwelling unit. Interior door leading to attached garage Interior door leading to attached garage Guard complying with Div.B, Subsection 9.8.8. Landing Required Not a flight (2 risers or less) Flight (3 or more risers) LANDING REQUIRED LANDING NOT REQUIRED Figure 4 Landings in Garages Page 7 of 9

Where a landing is required between the dwelling unit and the attached garage, the landing must be not less than 900 mm in length and at least as wide as the stairs. HANDRAILS Where a flight of stairs contains a set of winders, required handrails must be continually graspable at the transition from the straight-run stairs to the winders. If the handrail attached to the outer wall is not deemed to be a required handrail, then it is permitted to be discontinuous within the flight, therefore a gap in the handrail at the junction between the straight-run stairs and winders would be permitted. However, Article 9.8.7.5. still requires that there be nothing on the handrail that would cause a user to lose their grip. See Figure 5 and Figure 6 for clarification. One Handrail Required Two Handrails Required 1100 mm Figure 5 Handrails on Stairs with Landings Page 8 of 9

One Handrail Required Two Handrails Required 1100 mm Non-Required Handrail Figure 6 Handrails on Stairs with Winders LOADS ON GUARDS It shall be left to the discretion of the safety codes officer whether a guard demonstrates effective performance. If it is the opinion of the safety codes officer that the guard does not provide effective performance, then he can request that the guard complies with Table 9.8.8.2. CLIMBING PREVENTION The inclusion of or at the end of Sentence 9.8.8.6.(2)(c) means that a guard that complies with at least one of the clauses in Sentence 9.8.8.6.(2) shall be considered to not facilitate climbing. However, if a safety codes officer is of the opinion that a guard could still facilitate climbing, even though it has complied with one of the conditions in Sentence (2), he can require that the guard be modified to remove the potential for climbing based on Sentence (1). Additionally, Clause 9.8.8.6.(2)(c) not only applies to any given element, but also pertains to any two adjacent, separate spindles whose protrusions are close enough together to inadvertently create a toe space that is more than 45 mm horizontally and 20 mm vertically. These INTERPRETATIONS are applicable throughout the province of Alberta. Page 9 of 9