Owner s Manual. Scale Store CHC Crane Scale

Similar documents
OCSM Series. High Resolution Digital Crane Scale. User Guide

OCS-S High Resolution Digital Crane Scale

CONTIENTS. 1. SPECIFICATIONS (mm) CAUTIONS INSTALLATION INSTRUCTION

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

High precision counting scale. Operation Manual. l RCZ-A Series

Back-UPS Pro 1300/1500 Installation and Operation

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

ExStik TM ph Waterproof Meters

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

NortechCommander Software Operating Manual MAN R6

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

XP Series Balances Operation Manual

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

OCS-XZ-C Series User s Guide. OCS-XZ Series Electronic Crane Scale. User s Guide - 1 -

Model SRMD Setra Remote Monitoring Display

Keep it Simple Timing

PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION

AGRI-ALERT 800T / AGRI-ALERT 800 ALARM SYSTEM USER MANUAL

Dolphin 70e Black. Quick Start Guide. with Windows Embedded Handheld E-WEH-QS Rev B 6/13

Digital Air Pressure Gauge Users Manual

Automatic Phone-Out Home Monitoring Systems

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

Handheld force display AE 703

How To Set Up A Smart Card Programmer With Titan (Titan) And Titan 2.3 (Tok) (Tonga) (Powerbook) (Smart Card) (Programmer) (S

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

Installation and Operation Back-UPS 1250, 1300, 1500

Crow Limited Warranty. Print Version 017

1 For All Non-Programmable Digital Thermostat

User s Manual. Bluetooth Calculator Keypad. Page

Temperature & Humidity SMS Alert Controller

Instruction Manual FL

User Manual. EtherUSB

BW-500 BED WEIGHER USER MANUAL

User s Manual C R Y S T A L. engineering corporation

Thank you for purchasing the Huawei E5332 Mobile WiFi. This quick start guide will help you to get started right away.

Wireless Laser Barcode Scanner ils 6300BU. User s Manual

Aztech E310-Single/Twin BlackDect Phone

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Wireless Home Security Alarm System AM 500

Adam Equipment. CPWplus. RANGE OF SCALES (P.N. 9009, Rev. C, June 2008)

Manual. Solar Fountain Mobile Phone Charger

User's Guide. Integrating Sound Level Datalogger. Model Introduction

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Thank you for choosing HUAWEI Mobile WiFi

Installation Instructions For Controllers with MS/TP Automatic MAC Addressing. Patent Pending

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

PR-2500 Portable Receiver. Owner s Manual

INDUSTRIAL INSTRUMENTATION

Table of Contents. What is Brute Force Attack? 13 How does the diskashur protect against brute force attack? 13

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure

MSI3460. User Guide. Measurement Systems International. Challenger 3 Crane Scales

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

SYMBOL MC9060 HAND HELD TERMINAL USER MANUAL

HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15

User Manual. Humidity-Temperature Chart Recorder. Model RH520

OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

How To Use A Ci 2001A/B (I2) With A Power Supply (I3)

Dual Laser InfraRed (IR) Thermometer with Color Alert

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Instruction Manual Crane Scales PCE-HS Series

CASTON. Crane Scale. OWNER S MANUAL (BT Ver.) 9007-CT3-BT

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

Desktop Programmer (DTP)

BTX180 Wireless Bluetooth Speaker

ADEMCO LYNXR-I Security Systems

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

ELECTRIC FENCE ENERGISER

Table of Contents Function Keys of Your RF Remote Control Quick Setup Guide Advanced Features Setup Troubleshooting

My Weigh Ultraship Series User Manual

EMR-3000 Quick Start Guide. IB E Rev. A. Contents. Description

WARRANTY AND DISCLAIMER

Digital Weight Indicator Setup / Operation Manual

User Manual. EtherUSB

Auto Dialer. Manual E-921APQ E-921GPQ

Testing PCI/ISA & PCMCIA Serial Cards

HIGH PRECISION WEIGHING SCALE. Operation Manual. l RCZ-B Series

DVB-T 730. User s Manual

Universal Wireless Effects Controller USER S GUIDE SA115

Dual DVI USB KVM Switch

CS450. User Manual

Intelligent GSM Auto-Dial Alarm System

T Sentry 4 Multi-Point Digital Alarm Instruction Manual

Congratulations on purchasing SIMI by Molten Voltage

AN588 ENERGY HARVESTING REFERENCE DESIGN USER S GUIDE. 1. Kit Contents. 2. Introduction. Figure 1. Energy Harvesting Sensor Node

Supplementary Certificate of Approval NMI S669

Foglight Experience Monitor and Foglight Experience Viewer

Models CT-001, CT-002 Owner s Manual

VM-4 USB Desktop Audio Device Installation Guide

Operating Manual Electronic Wheelchair Scale with cable display M50610

Rack Mount LCD KVM Assembly Installer/User Guide

Notice. Reverse engineering and disassembly are prohibited.

IDS X-Series User Manual D Issued July 2012

Thank you for choosing HUAWEI E5331 Mobile Wi-Fi

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

VM-8 USB Desktop Audio Device Installation Guide

PK5500 v1.1 Installation Instructions

CORROSION PRODUCTS DIVISION GYPSY II. MSES consultants, inc. Users Manual. GPS Synchronized Current Interrupter. Model No. CI-200

LCD5500Z / PKP-LCD v3.x Installation Instructions

Transcription:

Owner s Manual Scale Store CHC Crane Scale 2015 by Fairbanks Scales, Inc. 51062 All rights reserved Revision 3 09/2015

This page intentionally left blank. 09/2015 2 51062 Rev. 3

Amendment Record Scale store ELECTRONIC CRANE scale series CHC series OWNER S manual Document 51062 Manufactured by Fairbanks Scales, Inc. 821 Locust Kansas City, Missouri 64106 Created 11/97 Created document Revision 1 11/97 Document release Revision 2 06/10 Revised manual Revision 3 09/15 Revised instructions throughout 09/2015 3 51062 Rev. 3

Disclaimer Every effort has been made to provide complete and accurate information in this manual. However, although this manual may include a specifically identified warranty notice for the product, Thurman Scales makes no representations or warranties with respect to the contents of this manual, and reserves the right to make changes to this manual without notice when and as improvements are made. Thurman Scales shall not be liable for any loss, damage, cost of repairs, incidental or consequential damages of any kind, whether or not based on express or implied warranty, contract, negligence, or strict liability arising in connection with the design, development, installation, or use of the scale. Copyright 2015 This document contains proprietary information protected by copyright. All rights are reserved; no part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without prior written permission of the manufacturer 09/2015 4 51062 Rev. 3

. Table of Contents Section 1: General Information... 7 1.1 Introduction... 7 1.2 Description... 7 1.3 Power... 7 1.4 Charging... 7 Section 2: Technical Features... 9 2.1 Technical Features... 9 2.2 Notes... 9 2.3 Load Cell Cable Connection... 10 2.4 Key Button function... 11 2.5 LED Light Adjustment... 12 Section 3: Function Menu... 13 3.1 Notes... 13 3.2 Keypad Operation... 13 3.3 Entering the Function Menu... 13 3.4 Function Menu Settings... 14 Section 4: Complete Calibration Menu... 17 4.1 Notes... 17 4.2 Keypad Operation... 17 4.3 Entering the Complete Calibrations Menu... 17 Section 5: Calibration ONLY Menu... 21 5.1 Notes... 21 5.2 Keypad Operation... 21 5.3 +Entering the Calibration ONLY Menu... 21 09/2015 5 51062 Rev. 3

Table of Contents This page intentionally left blank. 09/2015 6 51062 Rev. 3

Section 1: General Information 1.1 INTRODUCTION The CHC Series Electronic Crane Scales are used as hanging weighing devices in a wide variety of applications. This scale is intended for use in non-commercial applications, and is not legal for trade. NOTE: It is the owner's responsibility to document, notify, and follow-up regarding shipping damage with the carrier. 1.2 DESCRIPTION The scale is shipped in a crate, fully assembled and wired. The scale series capacities range from 1300 lbs. to 20,000 lbs. 1.3 POWER The power button is located on the front overlay. When the unit requires charging, please use the correct power supply (6 VDC/1A). 1.4 CHARGING The scale battery should provide 60 hours operating time (6V/10A). To provide sufficient power and prolong battery life, keep the battery charged. When the battery is running low, the display will flash to indicate it is time to recharge the battery. If you are unable to re-charge the battery immediately, the scale battery will last approximately another nine (9) hours. If the display reads LLLLL this indicates a very low battery. Stop using the scale and re-charge the battery immediately to protect the battery! When the battery charger is in use, it is best not to share power with other equipment on that same outlet. If the scale has not been used for three months or more, charge the battery before using the scale. When the charge light on the keyboard is: Red - Battery is not fully charged and is in the process of charging. Green - Battery is fully charged. 09/2015 7 51062 Rev. 3

Section 2: General Information This page intentionally left blank. 09/2015 8 51062 Rev. 3

Section 2: Technical Features 2.1 TECHNICAL FEATURES 1. Load cell division: 1/3000 2. Output voltage: 0mV ~ +3mV 3. Display: 5 digit, 7-segment red LED 4. General function: Zero adjustment, auto zeroing, auto calibration 5. Initial zero set-up: Maximum capacity < +10% 6. Related voltage: 110VAC/60Hz 7. Working temperature: -10 C ~ +55 C storage, and 0 C ~ 40 C operating 8. Battery specifications: 6.5V/10A (1 piece) 12V/7A (2 piece) Temperature: 0 ~ 40 C 9. Charger specifications: 110V/60HZ or 6 VDC/1A Temperature: 0 ~ 40 C 2.2 NOTES Avoid placing the scale in direct sunlight or in a moist environment. Keep the scale dry. Failure to do so will affect operation and weight readings. Please provide a stable power supply. 09/2015 9 51062 Rev. 3

Section 2: Technical Features 2.3 LOAD CELL CABLE CONNECTION PIN SIGNAL NAME 1. Excitation - 2. Signal - 3. Excitation + 4. Signal + 09/2015 10 51062 Rev. 3

Section 2: Technical Features 2.4 KEY BUTTON FUNCTION Press the ON/OFF key to power on or power off the scale. Turn the scale OFF to conserve battery power when weighing is complete. Press this key to freeze current weight (the LOCK indicator will be on). Press this key again to turn the lock weight function off. In the programming mode, this key is used to confirm a parameter and confirm a setting. Unit weight conversion (lb or kg) or spare key. In the programming mode, press this key to change the digit selected. Set the display to zero (0) or press ZERO key to deduct the container (tare) weight. Any weight zeroed will be subtracted from the scale capacity. In the programming mode, pressing this key will increase the value of the selected digit. 09/2015 11 51062 Rev. 3

Section 2: Technical Features 2.5 LED LIGHT ADJUSTMENT 1. Press the CHANGE key and hold for 5 seconds. The display will change as indicated below: L.CHG 2. Press the ZERO key to select brightness; 8 different brightness settings are available. LiG.H0 LiG.H7 3. Press the CHANGE key again to return to weight mode. 0.000 09/2015 12 51062 Rev. 3

Section 3: Function Menu 3.1 NOTES Some of the following parameters (functions) are not relevant to a crane scale application so a complete explanation is not provided. If a complete explanation is not provided, only the default setting is identified. 3.2 KEYPAD OPERATION Press this key to freeze current weight (the LOCK indicator will be on). Press this key again to turn the lock weight function off. n the programming mode, this key is used to confirm a parameter and confirm a setting. Unit weight conversion (lb or kg) or spare key. In the programming mode, press this key to change the digit selected. Set the display to zero (0) or press ZERO key to deduct the container (tare) weight. Any weight zeroed will be subtracted from the scale capacity. In the programming mode, pressing this key will increase the value of the selected digit. 3.3 ENTERING THE FUNCTION MENU 1. Power the scale off 2. Press and hold the ZERO key and the OFF / ON key. 3. Release the ZERO key when 4 is displayed. 4. Press the LOCK key, 5 is displayed. 5. Press the ZERO key, 6 is displayed. 09/2015 13 51062 Rev. 3

Section 3: Function Menu 6. Press the LOCK key and 4 5 6 briefly displays, then F 00 is displayed. The underlined digit is flashing. 7. Using the CHANGE and ZERO keys, you can enter the specific function / parameter needed. Example: F 12 Explanation: This identifies that with a press of the LOCK key, you will enter function / parameter 12. 8. Pressing the LOCK key enters you into the function / parameter. Example: 12 1 Explanation: The left number represents the function / parameter accessed and the right number is the current, or available, setting. 9. Toggle between the available choices using the ZERO key, accept the selection by pressing the LOCK key. IMPORTANT: When you accept the parameter selection by pressing the LOCK key, this automatically saves this setting. To exit the Function Menu, you must power off the scale! 3.4 FUNCTION MENU SETTINGS Function Function Explanation Selections Available (default is underlined) F 00 Do not change this setting. 01 F 01 Zero Tracking 00: No tracking 01: 0.5 div / 1 sec 02: 0.5 div / 2 sec 03: 0.5 div / 3 sec 04: 0.5 div / 4 sec 05: 1.0 div / 1 sec 06: 1.0 div / 2 sec 07: 1.0 div / 3 sec 08: 1.0 div / 4 sec 09: 1.5 div / 1 sec 10: 1.5 div / 2 sec 09/2015 14 51062 Rev. 3

Section 3: Function Menu 11: 1.5 div / 3 sec 12: 1.5 div / 4 sec 13: 2.0 div / 1 sec 14: 3.0 div / 1 sec 15: 4.0 div / 1 sec F 02 Do not change this setting. 01 F 03 Do not change this setting. 0 F 04 Do not change this setting. 99 F 05 Do not change this setting. 00 F 06 Do not change this setting. 1 F 07 Do not change this setting. 05 F 08 Filtering The higher the value, the heavier the filtering. 00 99 04 F 09 Overload audible setting 0: Enabled 1: Disabled F 10 Do not change this setting. 1 F 11 Do not change this setting. 1 F 12 Front panel units of measure change. Note: If set to 0, pounds only! 0 = No Units Change 1 = Units change F 13 Available units of measure 00: kg / lb 01: g / oz 02: g / lb 03: kg / kg 04: g / g F 14 Do not change this setting. 0 F 15 Do not change this setting. 1 F 16 F19 No parameters --- F 20 Do not change this setting. 0 F 21 Do not change this setting. 0 F 22 Do not change this setting. 00 F 23 Do not change this setting. 0 F 80 Restore Factory Default 00: Do not change 01: Back to original settings 09/2015 15 51062 Rev. 3

Section 3: Function Menu This page intentionally left blank. 09/2015 16 51062 Rev. 3

Section 4: Complete Calibration Menu Introduction The complete calibration menu will set the scale s capacity, division size, decimal location and calibrate the scale. 4.1 NOTES During calibration, use standard weights that are not over the scale s maximum capacity. CHC Calibration is done in kilograms, so if using avoirdupois weights make sure your conversion is accurate. 50 lbs = 22.68 kgs 100 lbs = 45.36 kgs 250 lbs = 113.40 kgs 500 lbs = 226.80 kgs 1000 lbs = 453.60 kgs Note: The scale s division setting might cause the need to round to the next digit. 4.2 KEYPAD OPERATION The LOCK key is used to enter a parameter and confirm a setting. The CHANGE key is used to change the flashing digit. The ZERO key changes the numeric value of the flashing digit or toggles through the available selections. 4.3 ENTERING THE COMPLETE CALIBRATIONS MENU 1. Power the scale off 2. Power the scale back on. Press and hold the CHANGE key and OFF / ON key. 3. Release the CHANGE key once 7is displayed. 4. Press the LOCK key, 8 is displayed. 5. Press the CHANGE key, 9 is displayed. 09/2015 17 51062 Rev. 3

Section 4: Complete Calibration Menu 6. Press the LOCK key and 7 8 9 briefly displays, then the Capacity size. Division size is displayed in KG. With the left most digit blinking. Example: 0600.2 Explanation: To the left of the decimal is the scale s capacity, to the right is the division size. In other words, the above example would have a capacity of 600kg with a division size of 0.2 kg. 7. Using the CHANGE and ZERO keys, you can change the capacity and division size of the scale. Note: This should rarely need to be changed, so please ensure this change is necessary before proceeding. 8. Pressing the LOCK key accepts the capacity and division size. Now the scale s capacity and decimal places are displayed with the decimal blinking. Example: 600.0 9. Pressing either the CHANGE or ZERO keys will move the location of the decimal. Note: This should rarely need to be changed, so please ensure this change is necessary before proceeding. 10. Pressing the LOCK key accepts the decimal location. The display counts down from 99999 to 00000, then displays the last calibration weight with the left most digit blinking. 11. Adjust the reading on the display with the test weight value (CHANGE and ZERO keys) that will be used to calibrate the scale. Note: Remember scale must be calibrated in kgs, so if using pound test weights, convert to kilograms. 12. Make sure no weight is on the scale. Then, to accept the displayed reading, press the LOCK key. The display will read PPP. X (X = random number). The scale has just established a zero reference. 13. Apply the programmed test weight to the under hook. Scale will automatically capture the span calibration. Note: Scale will begin capturing the test weight when the weight is stable, so make sure the entire test load is suspended as quickly as possible. 09/2015 18 51062 Rev. 3

Section 4: Complete Calibration Menu 14. When span calibration is captured, the scale will emit an audible beep and the unit will display the test load. 15. BEFORE CYCLING POWER To recalibrate simply press the CHANGE or ZERO key with no weight on the under hook. Then, restart the calibration sequence starting at step 13. 16. Cycle power to accept the calibration. 09/2015 19 51062 Rev. 3

Section 4: Complete Calibration Menu This page intentionally left blank. 09/2015 20 51062 Rev. 3

Section 5: Calibration ONLY Menu Introduction In most situations, the factory default capacity, division size and decimal location won t need to be changed. The Calibration Only Menu provides a means to perform the calibrate ONLY (zero and span calibration) without stepping through all the steps in the Complete Calibration Menu. 5.1 NOTES During calibration, use standard weights that are not over the scale s maximum capacity. CHC Calibration is done in kilograms, so if using avoirdupois weights make sure your conversion is accurate. 50 lbs = 22.68 kgs 100 lbs = 45.36 kgs 250 lbs = 113.40 kgs 500 lbs = 226.80 kgs 1000 lbs = 453.60 kgs Note: The scale s division setting might cause the need to round to the next digit. 5.2 KEYPAD OPERATION The LOCK key is used to enter a parameter and confirm a setting. The CHANGE key is used to change the flashing digit. The ZERO key changes the numeric value of the flashing digit or toggles through the available selections. 5.3 +ENTERING THE CALIBRATION ONLY MENU 1. Power the scale off. 2. Press and hold the LOCK key and press the OFF / ON key. 3. Release the LOCK key when 1 is displayed. 4. Press the ZERO key, 2 is displayed. 5. Press the LOCK key, 3 is displayed. 09/2015 21 51062 Rev. 3

Section 5: Calibration ONLY Menu 6. Press the ZERO key and 123 briefly displays, then the scale displays 999999 counting down to zero. Finally, the last calibration test weight value is displayed in KG. With the left most digit blinking. 7. Adjust the reading on the display with the test weight value (CHANGE and ZERO keys) that will be used to calibrate the scale. Note: Remember scale must be calibrated in kgs, so if using pound test weights, convert to kilograms. 8. Make sure no weight is on the scale. Then, to accept the displayed reading, press the LOCK key. The display will read PPP. X (X = random number). The scale has just established a zero reference. 9. Apply the programmed test weight to the underhook. Scale will automatically capture the span calibration. Note: Scale will begin capturing the test weight when the weight is stable, so make sure the entire test load is suspended as quickly as possible. 10. When span calibration is captured, the scale will emit an audible beep and the unit will display the test load. 11. BEFORE CYCLING POWER To recalibrate simply press the CHANGE or ZERO key with no weight on the underhook. Then, restart the calibration sequence starting at step 13. 12. *IMPORTANT* Cycle power to accept the calibration. 09/2015 22 51062 Rev. 3

Scale Store - CHC Crane Scale Document 51062 Fairbanks Scales 821 Locust St. Kansas City, MO 64106 www.fairbanks.com