BATIGYR BatiBUS Node FOR RCE86.X-VISONIK CONNECTION VISONIK 400/4000 PRV2.0 PRV PRV PRV

Similar documents
Controls for fan coil units and cassettes

OZW30. Central Unit SYNERGYR

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

NC-12 Modbus Application

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Heating Controller. Building Technologies HVAC Products

Cooling with CHW (fan coil Heating with LTHW radiator Modulating control of heating and cooling valve Automatic or manual fan control

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output

Inwall Room Temperature Unit

PD 100A. Printing data system

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

HERZ-Thermal Actuators

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Electronic Control Devices The European Product Catalogue 2007

Thermostat with display

Electric Rotary Actuator - On/Off or programmable control actuator

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Duct Humidity Transmitter

Actuator for modulating control AME 435

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Modular I/O System Analog and Digital Interface Modules

Flush-mounted room thermostats

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Unico Inverter. Unique and efficient.

IntesisBox Modbus Server SAMSUNG Air Conditioners

RY2 miniature industrial relays

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Thermostats. comfort at your command

Electronic Control Devices The European Product Catalogue 2007

RRV934. Multi-controller. Synco living

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Failure code manual. content

FIREDEX Conventional Fire Panels

Multi-Range Programmable DC Power Supplies 9115 Series

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox KNX LG Air Conditioning

Temperature & Humidity SMS Alert Controller

Stroom voor elke toepassing

Combi switchbox with integrated 3/2 way pilot valve

T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

PCS0100en Persy Control Services B.V. Netherlands

13 SERIES. Electronic step relays A

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

SMS GSM Alarm Messenger

HYDRUS ULTRASONIC METER

Remote Monitoring and REC 501 Control Unit Product Guide

Modbus Server SAMSUNG Air Conditioners

SKR - industry relay

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

48 SERIES Relay interface modules 10 A

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April SFC132089M0201 1

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

basicdim DGC Compact control module

Product Information Sheet UH36 Hi Pot Tester

KLQ750CO controller temp/intensity/feedback/24v/usb/rs622/analog trigger

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

AMTRON E-30 Compact heat and cooling meter

TMS TANK MANAGEMENT SYSTEM

3466 Building Energy Management Training Systems

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

3-phase, bidirectional energy meter

CGC s Hybrid System Loop Control

Digital input modules

FTQ. Daikin Inverter Ducted Heat Pump

DCS Data and communication server

Voltage Regulator SPAU 341 C. Product Guide

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

mecotron Safety relay ESTOP-2 For emergency stop monitoring

MXS 3. MANUAL FULLY CHARGED PULSE, MAINTENANCE CHARGING EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT CHARGE CABLE ERROR LAMP MODE- BUTTON

Installation manual. Generator Paralleling Controller GPC multi-line C

ACS-30-EU-EMDR-10-MOD

DS 600. A contact free flux gate based current measurement sensor 600A rms

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

ABB micro inverters MICRO-0.25/0.3-I-OUTD, CDD and accessories 250 to 300 W

Drayton Digistat +2RF/+3RF

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

T-100-R Installation Guide

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

T5000 T000 LCD Digital Fan Coil Thermostat

Technical Data. back-up time in minutes 100% load % load

Belimo Gateway MP to Modbus RTU - UK24MOD

Please refer to the chapters below for detailed information about all aspects of the products usage.

J TB/TW Temperature limiter, temperature monitor

Multi-Range Programmable DC Power Supplies 9115 Series

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Adjustable room thermostat for heating only or cooling only systems

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Transcription:

8 942 BATIGYR BatiBUS Node FOR RCE86.X- CONNECTION PNB Scale 1 : 2 8942P015 System overview 400/4000 Building Level PRV2.0 PRV PRV PRV PNB PNE BatiBUS Field Level 8942B02E RCE86.x The PNB is an interface between the BatiBUS and the PRV2.0. Any RCE86.x fan coil controllers connected to the BatiBUS are integrated into the PRV2.0, using the PNB. Siemens Building Technologies CM2N8942E / 02.1999 Landis & Staefa Division 1/6

System capacity A max. of 120 RCE86.x controllers per BatiBUS can be addressed and controlled by one PRV2.0. The RCE86.x address range is 0 to 29, of which the PRV2.0 can address the range from 1 to 29. In the PRV2, there can be up to 24 groups of controllers with max. 16 controllers per group. Additionally, up to 60 master / slave configurations with max. controllers are possible. Functions Mapping the RCE86.x values A range of RCE86.x values are mapped to PRV2.0 points and can be used in the PRV2.0 and the. As a result, the PRV2.0 contains a complete, accurate process image of all the RCE86.x controllers. - Temperature - Operating mode (Comfort / Eco / Standby) - setpoint Comfort heating - setpoint Comfort cooling - setpoint Eco heating - setpoint Eco cooling - Window contact - Changeover - VCF 1) Commands Different values such as operating mode, setpoints etc. for groups of controllers can be remotely changed from the PRV2.0. - Operating mode (Comfort / Eco / Standby) - setpoint Comfort heating - setpoint Comfort cooling - setpoint Eco heating - setpoint Eco cooling - Changeover - Range for local setpoint changes Operation Four Popcards allow simplified local operation of all RCE86.x connected to the BatiBUS. The same operations can also be configured on the Insight Master / slave Master / slave operation applies to rooms where more than one RCE86.x is installed. Master / slave functionality is used to synchronise these controllers. Any change in the master of the following parameters will be transmitted to its slaves. - Operating mode (Comfort / Eco / Standby) - setpoint Comfort heating - setpoint Comfort cooling - Changeover - VCF 1) 1) Master / slave information to make certain several controllers to not provide simultaneous heating and cooling for the same room. CM2N8942E / 02.1999 Siemens Building Technologies 2/6 Landis & Staefa Division

If at least one window of a Master / slave configuration is open, all controllers will change to the operating mode Standby. If all windows are closed, the controllers will go back to the group value. Energy handling (optional) Each RCE86.x transmits the electrical energy consumed and offers possibilities of influencing energy consumption. Display Command Consumed Energy per controller and per group Electrical output limit Authorisation of electric air heater battery Electrical output limit Authorisation of electric air heater battery Supervision of the communication The PNB supervises the communication between the PNB and the different RCE86.x, and reports its status to the PRV2.0. Interface to other applications In addition to applications already available, there is a clearly-defined interface for adding additional applications. Access to RCE86.x parameters The PRV2.0 has access to the following RCE86.x parameters: RCE86.x value Event driven Request for parameter Change of parameter Temperature every 5 min. Yes No Operating mode Yes Yes Yes Comfort heating setpoint Yes Yes Yes Comfort cooling setpoint Yes Yes Yes Eco heating setpoint No Yes Yes Eco cooling setpoint No Yes Yes Window contact Yes Yes No Changeover Together with mode Yes Yes for 2-pipe VCF Yes for masters Yes Yes Consumed energy No Yes No Elec. output limit No Yes Yes Elec. heating authorisation No Yes Yes Siemens Building Technologies CM2N8942E / 02.1999 Landis & Staefa Division /6

Popcard operation Display one RCE86.x controller Four Popcards operate the RCE86.x controllers from a PRV2.0. 1 Controller number Temperature Operating Mode Attached to group number Setpoint Comfort heating Setpoint Comfort cooling Setpoint Eco heating Setpoint Eco cooling Change over [1..29] 1=Comfort 2=Eco =Standby 0=warm water in pipe 1=cold water in pipe 0=window closed Window contact 1=window open 1=only heating VCF 2=heating & cooling forbidden =only cooling 4=heating & cooling allowed RCE86.x : Show Controller Ad.1 Pg.1 8942Z0 Set group values Group number [1..24] 2 Operating Mode 1=Comfort 2=Economy =Standby Setpoint Comfort heating Setpoint Comfort cooling Setpoint Eco heating Setpoint Eco cooling 0=warm water in pipe Change over 1=cold water in pipe 1=only heating VCF 2=heating & cooling forbidden =only cooling 4=heating & cooling allowed = AUTO RCE86.x : Group Settings Ad.1 Pg.2 8942Z04 Set values for all controllers Operating Mode 1=Comfort 2=Economy =Standby Setpoint Comfort heating Setpoint Comfort cooling Setpoint Eco heating Setpoint Eco cooling Range Comfort Setpoint [0..4.5 C] Limits : EH CH CC EC.. 14.5...2.5 20.5...29.5..0 Rules : EH 0.5 CH 2.0 CC 0.5 EC RCE86.x : Settings for all controllers Ad.1 Pg. 8942Z05 CM2N8942E / 02.1999 Siemens Building Technologies 4/6 Landis & Staefa Division

Energy handling 4 Controller number [1..29] Consumed Energy [kwh] Limitation el. Output [0..0 %] Authoris. el. heating 1=valve & electro 2=only valve =only electro Group number [1..24] Consumed Energy Reset to Zero [kwh] 1=Reset Limitation el. Output [0..0 %] Authoris. el. heating RCE86.x : Energy handling 1=valve & electro 2=only valve =only electro Ad.1 Pg.4 8942Z06 Technical data Operating voltage 24 V AC/DC ±15 % Frequency AC 50..60 Hz Power consumption max. 0.6 VA Ambient temperature Operation 0..40 deg. C Storage and transport -20..70 deg. C Weight 180 g PNB protection PTC resistor 200mA Cable between PRV and PNB max. 1.5 m Regulator load (C) 1mA C=2 Capacitance (DS) DS=. Configuration work needed A COLBAS Task in the PRV2.0 is used for the project specific information: Which RCE86.x controllers are connected Definition of the groups Definition of master / slave Accessories Name Type reference Data Sheet Power supply for BatiBUS PNE 894 2-pipe fan coil controller RCE86.2, RCE86.21 52 4-pipe fan coil controller RCE86.4, RCE86.41 54 Siemens Building Technologies CM2N8942E / 02.1999 Landis & Staefa Division 5/6

Connection diagram BatiBUS Phoenix MSTB2 M W1 M W1 + 8942A01E + RCE86.x PNE PNB 20 V AC RS22 PRV2.0 24 V G G0 Cable PNB-PRV 9 pole female D-plug The connection to BatiBUS is done by a Phoenix MST B2, which is part of the delivery. 2 5 max.1.5 m 25 pole female D-plug 1 2 7 Dimensions 4 126 5 5 75 90 5,5 64 7 EN 5002-5x7,5 16 8942M01 Dimensions in mm 1999 Siemens Building Technologies AG CM2N8942E / 02.1999 Siemens Building Technologies 6/6 Landis & Staefa Division