tsense (Disp) T RH RL

Similar documents
User Guide. Temperature and Humidity Datalogger. Model 42280

User Manual. SenseAir Alarm. Portable carbon dioxide sensor and alarm unit for personal safety with Real Time Clock

Inwall Room Temperature Unit

Instruction Manual. T3111 T3111L T3111P T3111Ex

Temperature & Humidity SMS Alert Controller

T0118 T2118 T3118. Instruction Manual

User Manual Weather station V 0.2

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Duct Humidity Transmitter

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Inwall 4 Input / 4 Output Module

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Manual & Technical Documentation V1.1

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

1 Application Description Objective Goals... 3

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500 Series Stand-Alone, Low-Cost Data Loggers

4-Channel Thermometer / Datalogger

1. SAFETY INFORMATION

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Model: Manual DC: WIRELESS COLOR FORECAST STATION

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

ENTBUS PLUS SOFTWARE FOR ENERGY MONITORING AND RECORDING INSTALLATION AND OPERATING MANUAL

PRODUCT LIST Facility DDC Access WebXL DDC

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

EL-USB-1-LCD Temperature Data Logger with LCD

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Field Calibration Software

RS DIGITAL THERMOMETER

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

User Manual Revision English

Model SRMD Setra Remote Monitoring Display

AC-115 Compact Networked Single Door Controller. Installation and User Manual

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

T7560A,B,C Digital Wall Module

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

USB-500/600 Series Low-Cost Data Loggers and Accessories

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

A-Series Data Loggers PRODUCT MANUAL

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

iloq P10S.10/20 Programming device User's Guide

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

GREISINGER electronic GmbH

Transmitter Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso

ECO SENSORS, INC. OZONE SENSOR AND MONITOR

USER MANUAL ESP. Enhanced Steering Performance. R-Net

Kurz MODBUS Client User s Guide

Transmitter Interface Program

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

VEHICLE DIAGNOSTICS THE AUTOCOM WAY

Users manual. TCW181B-CM_R1 Page 1

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Sierra S-Series Smart Interface Software User Manual

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Temperature Datalogger Users Manual

HOBO U14 Data Logger User Manual

ModS. SIO. USB analog. computer

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

T-100-R Installation Guide

Electronic Control Devices The European Product Catalogue 2007

IntesisBox ASCII Server - LON

IntesisBox KNX Mitsubishi Heavy Industries AC

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

TMS TANK MANAGEMENT SYSTEM

EVAL-UFDC-1/UFDC-1M-16

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

Peel Back Force Tester GPD s Peel Back Force Tester with FORCEWare software is being used to set peel back standards for the entire industry

STIM202 Evaluation Kit

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

NC-12 Modbus Application

SNMP Web Management. User s Manual For SNMP Web Card/Box

Kendrick Astro Instruments

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers

Online Infrared Flue Gas Analyzer Gasboard 3000

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

Repeaters and Mimics Data Sheet

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

ABB i-bus EIB Logic Module LM/S 1.1

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Model: DC-A2IO Advanced HVAC Controller

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Transcription:

Gas and Air Sensors User Manual tsense (Disp) T RH RL CO 2 -, temperature- and relative humidity transmitter General tsense (Disp) for wall mounting measures indoor air carbon dioxide concentration, temperature and relative humidity in rooms. tsense (Disp) is available with or without colour touch display (LCD). The unit connects to Direct Digital Control (DDC). Linear outputs are pre-programmed as CO 2 -, temperature- and relative humidity transmitter. Measuring ranges can be modified from PC (Windows) software UIP (version 5 or higher) and USB communication cable, alternative via Modbus or BACnet. 1 (23)

Table of contents General... 1 Table of contents... 2 Opening of housing... 3 Download of software UIP... 3 Enter PIN code... 3 PIN1 Delivered product... 3 PIN2 Delivered product... 3 Output Configurations... 4 Outputs... 4 Out1/Out2/Out3... 4 Voltage range... 5 Select source... 5 Types... 6 Measure range settings... 6 Relay... 7 Communication settings... 8 Address/Baudrate... 8 Connection configurations... 10 Measured values... 11 Display settings... 12 Limits... 12 Chart 24h/Week... 12 Screen settings... 13 Brightness... 13 Background... 13 Screensaver, Time setting... 13 Toggle (Time and CO 2 and/or Temperature and/or Humidity)... 14 Temperature unit ( C/ F)... 15 Meter information... 15 Calibration options CO 2... 16 Zero cal/background/target cal... 16 ABC... 17 Offset Temperature/Humidity... 19 Automatic system test... 19 Error codes and action plans... PIN codes... 21 Create PIN code for access to display settings (PIN1)... 21 Create PIN code for access to meter settings (PIN2)... 21 Maintenance... 22 Directives... 23

Opening of housing Figure 1 Plint Figure 1 Download of software UIP senseair.se/products/software/uip-5/ Figure 2: Connection to PC via phone jack Connect Interface cable USB 3.5mm Art.no.:00-0-0070 Enter PIN code PIN1 Delivered product 0000, Code off PIN2 Delivered product 01 (if not implemented: 0000) Power ON PIN2 (PIN1 Off) 3 (23)

Output Configurations Terminal Default Output Default Output Range Outputs of this sensor Output Ranges of this sensor OUT(1) 0-10 VDC 0-00ppm CO 2 See label See label OUT(2) 0-10 VDC 0-50 o C See label See label OUT(3) 0-10 VDC 0-100%RH See label See label Table 1. Default output configurations of tsense (Disp) Figure3: Screw Terminal Connect the sensor to PC with the connect interface cable USB 3.5mm Art.no.: 00-0-0070 The sensor is supplied with 0-10VDC linear outputs for Out(1), Out(2) and Out(3) (see Table 1). Alternative output ranges can be configured with PC software UIP (version 5 or higher). See information at senseair.com. Outputs Out1/Out2/Out3 Outputs Out1 4 (23)

Voltage range Max (the same approach with Min ) Outputs Out2 Max 10.0V, 9.9V..5.0V.. UIP5 Select source Source UIP5 Source CO 2 selected Save 5 (23)

Types Analogue/Analogue Invert Analogue Analogue invert UIP5 Invert Save (Set) Digital/Digital Invert Digital Digital Invert Measure range settings Low (the same approach with High ) Low 600ppm 600, 550 400ppm Low 400ppm UIP5 6 (23)

Outputs Relay Outputs Relay Type Digital UIP5 7 (23)

Communication settings Address/Baudrate RS-485 NOTE! UIP Address UIP Baudrate NOTE! UIP baudrate RS-485 baudrate if tsense (Disp) is connected via phone jack (see fig. 2). UIP baudrate = RS-485 baudrate if tsense (Disp) is connected via screw terminal (see fig. 3). Change communication settings via UIP requires Reset (Power OFF Power ON) to be executed. 8 (23)

Connect meter Connect meter Information 9 (23)

Check for updates New version available Connection configurations ModBus COM14-USB Serial Port Save Lower right corner of screen NOTE! UIP baudrate RS-485 baudrate if tsense (Disp) is connected via phone jack (see fig. 2). UIP baudrate = RS-485 baudrate if tsense (Disp) is connected via screw terminal (see fig. 3). Change communication settings via UIP requires Reset (Power OFF Power ON) to be executed. 10 (23)

Measured values CO 2 /Temperature/Humidity 11 (23)

Display settings Limits CO 2 /(Temperature)/(Humidity) CO 2 Orange/Red limit (Temp./Humidity, the same approach as for CO 2 limit settings) 100,0 700ppm CO 2 red limit 1000ppm RH orange limit 70%RH CO 2 red limit 1000ppm RH orange limit 70%RH Chart 24h/Week 12 (23)

Screen settings Brightness 10,, 50% Background Screensaver, Time setting Interval 3,4,5 10 s 50 s 13 (23)

Toggle (Time and CO 2 and/or Temperature and/or Humidity) Toggle time 3 s 3 s 3 s Toggle CO 2 and/or Temperature and/or Humidity Will NOT show up 3 s 3 s 14 (23)

Temperature unit ( C/ F) UIP5 Miscellaneous Meter information 15 (23)

Calibration options CO 2 Zero cal/background/target cal UIP: If reference meter shows e.g. CO 2 -value 500ppm set Target to 500 Background calibration button Press for 15s, until green LED blinks twice 16 (23)

ABC Enable/Disable Save UIP 17 (23)

ABC period (ABC target/altitude (msl)/restore cal) 180, 181, 240hours Save UIP 18 (23)

Offset Temperature/Humidity 0.0..-0.1-0.2 C Automatic system test A full system test is executed automatically at every power-up. Sensor probes are checked constantly during operation against failure by checking valid dynamic measurement ranges. System checks returns error bytes to RAM. Error codes are available by connecting the sensors to a PC with a special USB cable (art.no. 00-0-0070) connected (see fig. 2). Error codes are shown in software UIP (version 5 or higher) and in the display at Meter status. 19 (23)

Error codes and action plans Error symbol (a wrench appears when one or several error codes are active) Bit # Error code Error description Suggested action 0 CO 2 sensor No ability to communicate Try to restart sensor by Com. error with CO2 sensor module. power OFF - power ON. 1 CO 2 sensor CO 2 measure error 2 T sensor T measure error 3 RH/T sensor com error 4 RH/T sensor RH measure error 5 RH/T sensor T measure error 6 7 8 Output config. error CO 2 measurement error. Temp measurement error. No ability to communicate with RH/T sensor module. RH measurement error. Temp measurement error, sensor will use CO 2 sensor temperature if RH/T Temperature is unavailable. S_Temp will be set to NTC_Temp. Error in output configuration. Output is still updated, i.e. can be 0-10V Contact local distributor. Try Background calibration ( Calibration options CO 2 p.16). Contact local distributor. See Note 1! Try to restart sensor by power OFF - power ON. Contact local distributor. Check connections and loads of outputs. Check detailed settings and configuration with UIP software version 5 or higher. 9 Memory error One or several bytes of sensors parameter memory (settings) are corrupt Table 2: Error codes and action plans. Contact local distributor. Try to restart sensor by power OFF/ON Contact local distributor. NOTE! Occurs if probe is out of range, at very high CO 2 values. Error code resets automatically when measured values returns to normal. May also indicate need of zero point calibration. If CO 2 values are normal and error code remains, the sensor can be defect or the connections to it are broken. If several errors are detected at the same time, different error code numbers will be added together into one single error code! Sensor accuracy is defined at continuous operation (at least three (3) weeks after installation). (23)

PIN codes Create PIN code for access to display settings (PIN1) PIN1 PIN1 Code Off... PIN(1) Code On Create PIN(1) Code Save Create PIN code for access to meter settings (PIN2) PIN2 Create PIN2 Code Save 21 (23)

Maintenance tsense (Disp) is maintenance free. Internal self-adjusting calibration (ABC) function takes care of normal long term drift. To secure highest accuracy, a time interval of five years is recommended between CO 2 calibrations, unless some special situations have occurred. Software can be downloaded free at www.senseair.com. USB-cable and zero calibration kit can be ordered from SenseAir. Check can be done on site without interfering with ventilation system. 22 (23)

Directives This product is in accordance with the EMC 04/108/EC, 92/31/EEG, RoHS 11/65/EU including amendments by the CE-marking Directive 93/68/EEC The product fulfils the following demands: EN 61000-4-2 level 2, EN 61000-4-3 level 2, EN 61000-4-4 level 4, EN 61000-4-6, EN 61000-4-8 level 4, EN 55022 class B Contact SenseAir AB Europe SenseAir North America SenseAir Asia Box 96 Stationsgatan 12 SE- 860 Delsbo Sweden 29030 SW Town Center Loop East Suite 2 #169 Wilsonville, OR 97070 USA SenseAir Chengdu Gas Sensors Ltd. First floor of 8th of Xingke South Road Jiniu High-Tech, Industrial Park 610036, Chengdu China 23 (23)