Water Pressure Reducing Valves

Similar documents
WATER PRESSURE REDUCING VALVES

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

PRESSURE REDUCING CONTROL VALVE

Thermostatic Mixing Valves

See Mixing Valve Catalog (PHBRMIX) for more detailed information about the products in this section.

HYDROSTATIC TEST PUMPS

AIR LINE VALVES AND GAUGES

REGULATORS D& HD Series

TYPE E Main Valve Sizes 3 /8 through 12

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

400B SERIES DIAPHRAGM PUMP

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

Installation, Maintenance, & Repair Series 4000B/LF4000B

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Frequently Asked Questions

Type 92S Pilot-Operated Steam Regulator

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

FIRING RANGE PHASE 1 DESIGN

COUNTERBALANCE VALVES

Many Products...One Source

Why and How we Use Capacity Control

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

Solenoid Valves and Their Importance in Refrigeration Systems. October 2007

V47 Series Temperature Actuated Modulating Water Valves

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

1805 Series Relief Valves

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

APCO SLOW CLOSING AIR/VACUUM VALVES

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Pressure reducing valves. Guide of applications

Domestic Hot Water Systems and Plumbing Products

EMERGENCY PLUMBING FIXTURES

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

CHAPTER II. This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192.

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

Commercial & Industrial Propane Regulators and Meters

REGULATORS 175/153 Series

DESIGN STANDARDS SECTION

Surge Pressure in Plumbing Pipe Materials

Hose Clamps & Fittings

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Water Pressure Reducing Valves

Commercial Gas Cooking Thermostats

GS-General Service Control Valves

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

167D Series Switching Valves

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

DV-5 Deluge Valve with Remote-Resetting, Pressure-Reducing Trim 4 Inch and 6 Inch (DN100 and DN150) General Description.

relief valves 500 Series Adjustable Popoff & Inline Relief Valves 0.5 to 150 psig (10 bar)

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS

PRESSURE REDUCING VALVES

REGULATING VALVE APPLICATIONS

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)

ORLANDO srl. M P R OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Quick- Connect. Quick-Connect Plumbing Products Catalog and Price List. Effective February 29, Watts. c om

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

NITROUS TRANSFER PUMP INSTRUCTIONS

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Understanding the new lead-free water system regulations and choosing valves to comply

Model 1210C Battery Powered Pump Shown. Description

Installation, Maintenance, & Repair Series 909 and LF909 Reduced Pressure Zone Assemblies

SELECTION, APPLICATION AND MAINTENANCE

BACKFLOW PREVENTION Product Catalog

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

RMF Engineering

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

SIZING AND CAPACITIES OF GAS PIPING

Application Feature Valve Nominal Liquid Capacity R-22 (in tons)*

C I T Y O F S E L M A F I R E D E P A R T M E N T

Copper Meter Resetters

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

SELECTION, APPLICATION & MAINTENANCE

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

VSO MAX HP High Flow Proportional Valve

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Typical Aluminum GFM Mass Flow Meter

MEASURE AND CONTROL INVENTORY MANAGEMENT CONSOLE (IMC) Console for stand alone use Console with PC interface, software & USB cable

SECTION DUCTILE IRON PIPE AND FITTINGS

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Direct-Operated Pressure & Temperature Regulating Valves

Stainless Steel Single and Dual Circulation Kits

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

FAQ and Device/Usage Chart. What Is a Cross-Connection? What Is Backflow Prevention? What Is Backflow?

Transcription:

Water Pressure Reducing Valves Controlling Water Pressure in Residential, Commercial, and OEM Applications Watts.com

The One-stop Shop for Pressure Regulators Watts is the manufacturer of choice for Water Pressure Reducing Valves (WPRVs). Here's why: Durability in design with high-grade Lead Free* material suited for even the most challenging application High performance and exceptional flow characteristics Breadth & depth of offerings means you get the right product for the right application, all from a single vendor Industry leader for 140 years with the largest installed base Common Applications for WPRVs Residential homes, apartments, and dormitories Commercial businesses, hospitals, schools, and hotels, as well as irrigation and agricultural applications Specialty/OEM original equipment applications for example, beverage dispensers 2

Water Pressure Reducing Valves LF25AUB Standard Capacity Pressure Reducing Valves 2" 2" (15 50mm) Industry-trusted design with proven track record for longevity, reliability, and flow performance Lead free copper silicon alloy with stainless steel strainer and high-temperature diaphragm to ensure success in any installation Available in options such as high or low-pressure settings, gauge ports, etc. End connection options such as PEX, CPVC, and Quick-Connect NSF 61-G approved for potable-water applications and compliant with ASSE 1003 standards LF25AUB LFN55B Standard Capacity Pressure Reducing Valves 2" 2" (15 50mm) Durable brass spring cage Intergral strainer Proven and economical valve Ideal for new residential construction Designed and assembled in the USA LFN55B LFN45B Standard Capacity Pressure Reducing Valves 2" 2" (15 50mm) Compact design and engineered resin-caged PRV design EZ set option for the 3 4" & 1" sizes Sealed spring cage supports both indoor and outdoor installations and flexibility in orientation of install Available with threaded, solder, PEX, CPVC, or Quick-Connect end connections NSF 61-G approved for potable-water applications and compliant with ASSE 1003 standards LFN45B * The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. 3

Water Pressure Reducing Valves LFU5B LFU5B Standard Capacity Pressure Reducing Valves 2" 2" (15 50mm) Heavy, rugged design suited for high-flow performance and easy serviceability for potable-water applications Corrosion-resistant, cast iron spring cage Available in a range of end connection and pressure setting options NSF 61-G approved for potable-water applications and compliant with ASSE 1003 standards LF223 LF223 High-Capacity Pressure Reducing Valves 2" 2" (15 50mm) Heavy construction with enlarged diaphragm, spring cage, and seat support for exceptional performance Suited for demanding applications requiring high flow capacity max pressure 300psi Available in options such as strainer, bypass, flanged ends, high-pressure or low-pressure settings NSF 61-G approved for potable-water applications and compliant with ASSE 1003 standards LF115 LF115 Pressure Reducing Automatic Control Valves 1 4" 16" (32 400mm) Reduce high inlet pressure to constant, lower outlet pressure across a broad range of flow rates Valves can be installed in parallel or series configurations for extended flow range or staged pressure reduction Field-adjustable downstream pressure set point Common feature combinations include pressure reducing with hydraulic check, solenoid (on-off), downstream surge protection, or upstream pressure sustaining NSF 61-G approved for potable-water applications 4

LF26A and LF263A Specialty Pressure Reducing Valves 8" 1 2" (3 15mm) Compact design with aluminum spring cage ideal for OEM and small-flow applications Over-sized openings geared towards dispenser equipment max pressure 300psi Flexible options and configurations (i.e. gauge connection, pressure ratings, etc.) LF263A is a 3-way port model SS263AP constructed of all stainless steel NSF 61-G approved for potable-water applications LF26A P60 Miniature Pressure Reducing Valves Size 1 4" (8mm) Miniature footprint with thermoplastic construction suitable for food-grade applications Flexibility in configuring flow passage to be straight-through inlet to outlet or 90 flow inlet to outlet Available with a range of options including hose connections and gauge ports max pressure 300psi NSF 61-G approved and manufactured using FDA-approved material P60 LF560 Compact Pressure Reducing Valves 4" 1 2" (8 15mm) Compact design suited to OEM equipment or industrial processes requiring low flow capacity Available with standard threaded inlet and outlet or with hose-connection ports (H560 model) Stainless steel stem and spring with heavy slotted and knurled adjusting screw Offered with standard 3mm gauge port NSF 372 approved for potable-water applications LF560 LF215 Water and No. 2 Fuel Oil Pressure Reducing Valves Sizes ¼" 3 8" (8 10mm) Designed for specialty applications requiring high-sensitivity regulation Stainless steel strainer with high-mesh screen Large diaphragm design suited for high response at low flow NSF 372 approved for potable-water applications LF215 5

Watts WPRV Selection Guide Use our guide to WPRVs and accessories to find the right Watts model for your application. Standard Capacity (Residential, Light Commercial) Series LFU5B LF25AUB LFN55B LFN45B Sizes 1 2" - 2" 1 2" - 2" 1 2" - 2" 1 2" - 2" Max working pressure 300psi 300psi (std) 400psi (Z7 model) 400psi 400psi Max working temperature 160 F (71 C) 160 F (71 C) 180 F (82 C) 180 F (82 C) Standard adjustable pressure range 25-75psi 25-75psi 25-75psi 25-75psi Low pressure range High pressure range Thermal bypass Gauge port Strainer EZ-Set indicated pressure adjustment Water meter connection compatibility Agency Approvals NSF 61-G/372 61-G 61-G 61-G 61-G ASSE 1003 CSA B356 UPC MIL-V-1814B Type 1 End Connections Options Threaded Solder PEX CPVC Quick-Connect Flanged Hose connections Accessories Repair kit Unions/Nuts/Tailpiece kit 6 Available standard Available as option Not available

High Capacity (Commercial, Industrial) Specialty LF223 LFN223B LFN223F LF115 LF26A LF263A SS263AP P60 LF560 LFH560 LF215 1 2" - 2 1 2" 2 1 2" - 3" 3" 1 1 4"- 16" 1 8"- 1 2" 1 4" - 1 2" 1 4" - 1 2" 1 4" 1 4", 1 2", 3 4" 1 4", 1 2", 3 4" 1 4" - 3 8" 300psi 300psi 300psi 400psi 300psi 300psi 400psi 300psi 300psi 300psi 300psi 160 F (71 C) 160 F (71 C) 160 F (71 C) 180 F (82 C) 140 F (60 C) 140 F (60 C) 140 F (60 C) 150 F (65 C) 140 F (60 C) 140 F (60 C) 120 F (49 C) 25-75psi 25-75psi 25-75psi 30-300psi 10-125psi 10-125psi 10-125psi 0-125psi 0-125psi 0-125psi 0-50psi 61-G 61-G 61-G 61-G 61-G 61-G 61-G 61-G 372 372 372 Available standard Available as option Not available 7

WPRV Overview There are two types of water pressure reducing valves: pilot-operated and direct-acting. Types of WPRVs Pilot-operated valves have a sensing control pilot and main valve in one unit. These valves are typically used in commercial applications such as schools, hotels and hospitals, as well as in industrial and municipal applications and installations that require more consistent pressure control over wide flow ranges. Those applications typically demand valves with larger diameters, ranging from 1¼" to 16". Direct-acting valves, on the other hand, have a spring-loaded diaphragm that connects to a disc, which modulates the outlet flow controlling pressure. They are the most commonly used WPRVs and are found in a range of applications, including residential, OEM, and commercial, where diameters smaller than 3 inches are acceptable. How WPRVs work 1) WPRVs are installed to reduce the pressure from the water supply main to a lower, user-desired level. Water entering the valve is constricted within the valve body. This action is controlled by an adjustable spring-loaded diaphragm and disc. Even if the supply water pressure fluctuates, the WPRV ensures a constant flow of water at a functional pressure as long as the supply pressure does not drop below the valve s set pressure. Watts WPRVs are adjustable and typically preset at 50psi. 2) The WPRV operates utilizing the balance outlet pressure and spring compression. The setpoint is the desired outlet pressure when the regulator is flowing. It can be adjusted by loading or unloading the spring. If the downstream pressure is below the setpoint, the spring pushes the valve open. This action increases the flow through the regulator, which in turn raises downstream pressure. If the downstream pressure is above the set pressure, the diaphragm compresses the spring, pulling the valve closed. This action will close the regulator, decreasing flow and ultimately shutting off the regulator at the static or lock-up pressure until there is demand. Spring Seat Diaphragm Disc Inlet Outlet 8

Direct Acting Performance Curves To help you match WPRV characteristics to your system requirements, Watts provides performance curves for each type and size of WPRV the company offers. The curves are based on and tested to the ASSE 1003 standard and compare the capacities of each valve with reduced pressure fall-off levels. Use Watts performance curves to select the WPRV that best suits your job requirements and budget. End Connections To facilitate installation and servicing of a WPRV, Watts offers a variety of end fitting configurations, including union fittings (female threaded, solder, CPVC, PEX, and Quick- Connect end connections), flanged valves, water meter threads and special lay lengths for water meter installations. Please refer to valve models for specific availability of end connection options. Reduced Pressure Fall-off kpa psi 172 25 138 20 103 15 69 10 34 5 Sizes 1 2", 3 4", 1" (15, 20, 25mm) 1 2" 3 4" 1" 0 0 0 10 20 30 40 50 gpm 0 38 76 114 152 190 lpm Solder Threaded CPVC kpa psi 172 25 Sizes 1 1 4", 1 1 2", 2" (32, 40, 50mm) Reduced Pressure Fall-off 138 20 103 15 69 10 34 5 0 0 1 1 4" 1 1 2" 10 30 50 70 90 110 gpm 38 114 190 266 342 418 lpm 2" PEX Quick-Connect 9

Choosing the Correct Installation Configuration Single Regulator Installation Single regulator installation is the most typical installation configuration. It is recommended where incoming pressure is less than 200psi and when the reduction ratio is less than 3:1. City Mains 160psi Shutoff WPRV 60psi Supply to building Two-Stage Serial Reduction Installation Two-stage reduction is recommended when the initial pressure is 200psi or greater, or when the desired pressure reduction ratio is greater than 3:1 (e.g. from 200psi to 50psi), or when the inflow pressure fluctuates greatly. This approach helps prolong valve life and provide more precise pressure regulation. City Mains 200psi WPRV 1 85psi WPRV 2 50psi Supply to building Parallel Installation Parallel installation is recommended for applications with a wide variation of reduced pressure requirements and where a continuous water supply must be maintained. Parallel installations offer the advantage of providing increased capacity beyond that provided by a single valve and improve valve performance for widely variable demands. City Mains WPRV 1 WPRV 2 Supply to building NOTICE We recommend restricting installations to two valves for most applications to avoid excessive pressure drop and to ensure more precise control of reduced pressure. The number of regulators used should be based on the engineer s judgment, based on operating conditions for a specific installation. 10 NOTICE The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product.

WPRVs Promote Conservation and Sustainability Water Savings Energy Savings Twice as much water flows through a system at 150psi than at 50psi. At the higher pressure, much of the water flowing through the system is wasted. The less water that flows through a system, the less energy is needed to heat it, resulting in lower energy costs. Calculations demonstrate that a WPRV installed in a residential setting can produce as much as 30% savings on water heating costs. LEAD FREE * We Are Lead Free The Reduction of Lead in Drinking Water Act, requires that every pipe, fixture, and fitting used to convey water for potable use contain less than 0.25% lead by weight. Today, all Watts WPRVs are lead free and compliant with the Lead Free mandate. Wastewater Savings Many municipalities prorate sewer usage fees based on meter readings. When a community s wastewater treatment load is reduced, the environment benefits and property owners realize savings. * The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. 11

Represented by: A Watts Water Technologies Company USA: Tel: (978) 689-6066 Fax: (978) 975-8350 Watts.com Canada: Tel: (905) 332-4090 Fax: (905) 332-7068 Watts.ca Latin America: Tel: (52) 81-1001-8600 Fax: (52) 81-8000-7091 Watts.com F-PRV 1549 MF10455 2015 Watts