We Build Local Communities

Similar documents
The first apartment house renovation with Passive House components in Norway

Klosterenga, Oslo, Norway, page - 1

Reducing energy consumption in a historical school building

Norwegian Tax Authority - Oslo Norway

Passive house rehabilitation of post war residential building in Zug, Switzerland

Passive House Projects in Norway an Overview

Fra idé til virkelighet. Sustainable refurbishment SURE Copenhagen, March 23 rd Kongsgård Borettslag Kristiansand, Norway

Kvernhuset Lower Secondary School

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

A global list. The Fortification Depot A CO 2 -reduction project

Energy Efficient HVAC-system and Building Design

The climatic challenge of designing a prefabricated catalogue house meeting the criteria of the Norwegian passive house standard

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Energy savings in the residential area are essential in

Center for Energy Education Laboratory

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

RESNET National Rater Test Study Guide Outline

Challenging the possibilities

ROOFS, SNOW AND ICE DAMS

Portuguese Certification System for Energy an Indoor Air Quality Statistical Information about the Portuguese Certification System

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Norwegian Tax Authority - Oslo Norway. Arne Førland-Larsen

WP5_D.19 Skills Profile SUMMARY REPORT

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Innovative solution for heat recovery of ventilation air in older apartment buildings - with low intervention affecting the residents

Energy Efficiency in Buildings

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

CAN DEMAND CONTROLLED VENTILATION REPLACE SPACE HEATING IN OFFICE BUILDINGS WITH LOW HEATING DEMAND?

Case study on residential building renovation and its impact on the energy use and thermal comfort

2014 British Columbia Building Code Changes

Handbook for Basement

Directorate for the Built Environment Building Standards Division

9 Energy management. 9:1 General. BFS 2011:26 BBR Oct. 9:11 Scope of application

Sustainable Strategies for Rehabilitation Projects: 9th Street Office Building Adaptive Reuse Case Study

Residential HVAC System Sizing

solutions & tips six Wise Energy Guide Building envelope solutions and simple tips AIR SEALING

Home Management Checklist: Spring

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

Delivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015

SIP (STRUCTURAL INSULATED PANEL)

Europaparlamentet har allerede vedtatt at alle bygg oppført etter 2020 skal være nesten selvforsynt med energi, men hva med plusshus?

School in Schwanenstadt, Austria

A Roof Integrated Solar Heating System Without Storage

áååçî~íáîé=äìáäçáåöë

The Reunion experience

Before You Start an Energy Efficiency Retrofit The Building Envelope

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Jimmy Vesterberg. A regression approach for assessment of building energy performance A Licentiate Thesis in Energy Technology

Renovation instructions

Coventry Senior Living

FLORIDA STATE UNIVERSITY INTERNATIONAL PROGRAMS VALENCIA "GOLD" STUDY CENTER

High Performance School Buildings Resource and Strategy Guide

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

HANLO The WELCOME HOME Experience.!! Simply better homes!!

Your Personal Home Energy Action Plan

Improving thermal insulation of concrete sandwich panel buildings

Green Building of Senior Housing - Nuts and Bolts - Community Housing Partners

ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ

Technical Solution Sheet : Mechanical Services (Including duct heating)

OEGNB - Open Source Building Assessment

2009 Seattle Energy Code Impacts: See below for a recap of Changes in Envelope performance from 2006 to 2009

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

Water Damage & Repair

Schedule B to By-law Part A Fees Payable for Permits

Air Conditioning Contractors of America

Residential Weatherization Plus Program

Financing Options to support Energy Efficiency & Contractors

SCHEDULE A BY-LAW B-6 CLASSES OF PERMITS AND FEES

A comparative study of energy certification systems for buildings

Zen House. A Case Study on Design, Construction and Cost/benefit Analysis of a High Performance Home. Presentation for Net Zero Networking & Exchange

THE IC Y N E N E AD V A N T A G E

Impact on improved energy efficiency from preserving cultural values of buildings in Norway.

CITY PLAN REVIEW AND INSPECTION. Lisa Fleming Brown, CPM

enercase Multi-Family Apartment Building Heating Control System

Green House, Hungary

Building Energy Modelling. prescriptive

Building Energy Labels: The Swiss MINERGIE Label

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Contract for Weatherization Management Address City & State

BPC Green Builders. Green building for new and existing homes. Health Comfort Energy

Housing Fact Sheets. Moisture Condensation at the Windows

Green Affordable Housing Development Case Eco-Viikki, Finland

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

Structure Survey Findings:

FLORIDA SOLAR ENERGY CENTER

Energy efficiency building standards in Japan

bout your apartment SOLVING ODOUR TRANSFER PROBLEMS IN YOUR APARTMENT Understanding Air Movement in Your Building

Preventing Ice Dams on Roofs

Sustainable building retrofits in Finland

ResearcH JournaL 2009 / VOL

bout your HOUSE before you start Renovating Your Basement Moisture Problems

Old office building in Sandvika transformed into the Tesla of the building industry

RELEASE NOTES EG USA 3.0.0

This permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained).

bout your house before you start Renovating Your Basement Moisture Problems

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

air conditioners how to choose a cooling system

Franciscan Monastery, Graz, Austria

PAPERS PRESENTED AT THE CONFERENCE PASSIVHUSNORDEN 2012

Transcription:

16.05.2011

We Build Local Communities One of Norway s leading concerns in entrepreneuring and property development 1.000 employees Revenue appr. 2,3 billion NOK in 2010 Earnings before tax appr. 90 mill NOK Development and construction of commercial and private property 11 companies from Trondheim and further south Equity appr. 500 mill. NOK Owned by the Backe family 2

Company Structure 3

Market Area BERGEN Backer Entreprenør ELVERUM Martin M. Bakken BAS Maskinutleie GJØVIK Miljøbygg BAS Maskinutleie RUDSHØGDA Mjøsen Murmesterforretning KLØFTA Agathon Borgen OSLO AS Backe Ing. Gunnar M. Backe Backe Entreprenør Backe Eiendom LINDEBERG BAS Maskinutleie KONGSBERG Bøhmer Entreprenør REVETAL VåleBygg HOF BAS Maskinutleie SKIEN Buer Entreprenør GRÅLUM BAS Maskinutleie FREDRIKSTAD Backe Østfold SANDNES Backe Bygg TRONDHEIM Aasen Bygg 4

Myhrerenga Housing Cooperative. Norway s first Rehabilitation of Apartment Buildings to Passive House Standard Det første blokkprosjektet i Norge som rehabiliteres til passivhusstandard. Mål om 90% reduksjon av oppvarmingskostnader! 5

Myhrerenga before Rehabilitation 168 apartments in 7 houses Built in 1968-1970 Bad indoor air quality, draft, cold floors Exhaust ventilation Annual energy consumption 275kWh/m2 6

Myhrerenga before Rehabilitation Cracks, damages Thermal damages!!! Thermal insulation in walls and roofs 5-10 cm Great need of rehabilitation 7

Choice of Solution The cost of a traditional rehabilitation of the facade was estimated to appr. 35 million NOK, a rehabilitation to passive house standard would cost about 70 million NOK. SINTEF Byggforsk calculated that rehabilitation to passive house standard would be cheaper when considering the cost of heating Passive house rehabilitation was chosen. 8

Contributors in the Process Project Management: Architect: Consultant engineering: Consultant HVAC and plumbing: General contractor: Boligbyggelaget Usbl Arkitektskap AS Norconsult, SINTEF Byggforsk Norconsult, SINTEF Byggforsk Agathon Borgen AS 9

Cost Estimate Passive House Rehabiliation : Monthly Costs in NOK 1bedr. apart. 2-bedr. Apart. Fixed costs (maintenance, taxes, CE, etc)* 1290 1560 Energy costs (heating and electricity)** 370 470 Borrowing costs (interest rate, installments)*** 1760 2250 Total montly costs 3420 4280 Tax credit (loan interest rate)**** 230 290 Net monthly costs incl. tax credit 3190 3990 Traditional Facade Rehabilitation: Monthly Costs in NOK 1 bedr. apart. 2 bedr. apart Fixed costs (maintenance, taxes, CE, etc)* 1290 1560 Energy costs (heating and electricity)** 890 1130 Borrowing costs (interest rate, installments)*** 1560 1990 Total monthly costs 3740 4680 Tax credit (loan interest rate)**** 230 290 Net monthly costs incl. tax credit 3510 4390 10

Measures taken: Additional insulation in all facades and roofs The building is made airtight New windows and doors with very low U-value Balanced ventilation that reuses heat Solar thermal collectors and heat pumps are installed New and effective convector radiators 11

Walls and Windows 12

Window Window is mounted with brackets on OSB All joints are taped 13

Wall with Rockwool Flex System Flex is technically approved for outdoor use without exterior wind barrier Requires accurate mounting 14

Roof Insulation was blown into the wooden roof Moisture damages? 15

Airtightness became a challenge Measured airtightness in the whole building: 0,7!! Big amounts of tape 16

Balanced ventilation Separate systems in each stairwell Uses old garbage shaft as air duct Recycles heat with effect of 80 % SFP = 1,5 17

Simple air duct construction Involves little construction work indoors 18

Renewable energy 3 heat pumps 44 vacuum solar thermal collectors on the roof 19

Challenges Airtightness Cold weather 25 days per building without central heating One entire outdoor wall and balconies had to be replaced, also in minus 20 degrees!! Unsimilar interior in apartments as suspended ceiling Planned solutions had to be altered 20

Reasons for success in the contrcution process Details well planned before startup Construction inside the apartments planned in detail. Limit the time inside the apartments. STICK WITH THE PLAN! Good information given to residents early. Residents will accept much when informed. Tidy workers!!!!! Good and safe access to site 21

End result From 275 kwh/m2 to appr. 90 kwh/m2 22