2009 Seattle Energy Code Impacts: See below for a recap of Changes in Envelope performance from 2006 to 2009
|
|
|
- Paulina Thompson
- 10 years ago
- Views:
Transcription
1 2009 Seattle Energy Code Impacts: Building Envelope Impacts: Below is a Summary of Changes that impact building envelope construction planned for 624 Yale. There are several modifications are required to comply with the 2009 Seattle Codes Seattle Energy Code Impacts: See below for a recap of Changes in Envelope performance from 2006 to Seattle Energy Code Changes for Non-Residential Projects Envelope Component 2006 Seattle Energy Code 2009 Seattle Energy Code Code Glazing Percentage (Window-to-Wall Ratio=WWR) 45% 40% Glazing U-Value Glazing Solar Heat Gain Coeff Glazing Visible Light Transmittance Opaque Wall (metal studs) R-value R-13 + R-7.5 rigid c.i. R-13 + R-10 rigid c.i. Opaque Wall (mass) R-value R-13 + R-7.5 rigid c.i. R-13 + R-10 rigid c.i. Floor R-value (mass) R-30 R-30 Roof R-value (insulation above) R-30 R-38 Color Legend for Table Above No Change from 2006 SEC Increase in Code Stringency Review of Envelope Compliance for 624 Yale o Envelope performance planned in 2008 for the 624 Yale Building does NOT comply with the 2009 Seattle Energy Code (SEC) requirements without modifications o Additionally, the performance of the envelope planned in 2008 had a safety factor that was above the minimum required. This was recommend in case there were permit corrections that were received from the Seattle DPD. o Most projects that Rushing has submitted under the 2009 SEC have a minimal safety factor for envelope compliance and have not needed to change envelope assemblies from what were planned at the time of permit submission. o Based on reviewing the envelope the following improvements in the envelope assemblies are recommended by Rushing/NBBJ: Upgrading the Glazing Performance to meet 2009 SEC default minimum performance values Upgrading the Roof Insulation These upgrades provide enough improvement in the envelope performance to comply with the 2009 SEC requirements of 17
2 Building Envelope Impacts: 2009 Seattle Energy Code Impacts, continued: Table showing impact of Envelope Improvements and Compliance Margin 624 Yale ENVSTD Summary Envelope Component Code Building (points) ENVSTD Output for Compliance under 2006 SEC Proposed Building (points) Points above Code % Above Code ENVSTD Compliance under 2006 SEC % ENVSTD Complance under 2009 SEC with Glazing Upgrade % ENVSTD Compliace under 2009 SEC with Glazing Upgrade & Roof Upgrade % Description of Glazing Performance Upgrade recommended for 2009 SEC Compliance o Glazing assumptions from 2008 permit set for 2006 SEC Compliance U-Value = 0.40 SHGC = 0.38 VT = 0.60 o Glazing requirements for 2009 SEC Compliance U-Value = 0.38 SHGC = 0.35 VT = 0.60 o Additionally, refer to Seattle DPD CAM 403 for information required for permit submission that requires NFRC simulations for the basis of design glazing at permit intake. ENVSTD Output for Compliance under 2009 SEC with Glazing Upgrade of 17
3 Building Envelope Impacts: 2009 Seattle Energy Code Impacts, continued: Description of Roof Performance Upgrades recommended for 2009 SEC Compliance o Increase roof insulation by 1 ENVSTD Output for Compliance under 2006 SEC with Glazing Upgrade & Roof Upgrade Other Envelope Performance Assumptions to Recap o Glazing is assumed to remain as fixed glazing. There were no operable windows planned for 624 Yale due to acoustical concerns with proximity to I-5 and Mercer Interchange with I-5. Adding operable windows (U=0.45, ~18% higher than code default) would require further changes to the envelope components and may trigger energy modeling (RS-29) to comply with 2009 SEC code provisions. o West Façade Glazing and Vertical Fin Elements NFRC rating of the glazing for U-Value thermal performance will need to be carefully reviewed with the glazing manufacturer. There may be benefits to reducing the depth of the fins as this may reduce the size of the support brackets which may result in a better thermal performance for the glazing. The size of the vertical fin cannot be modeled in ENVSTD therefore reducing (and therefore shading from the fins) does not impact the shading assumptions in ENVSTD. o Stairwell skylight to remain as this provides a daylighting credit. If skylight is removed this reduces the daylighting potential of the building and reduced the proposed building ENVSTD points by ~200 points. Building therefore would not comply without further envelope upgrades above and beyond what was considered for glazing and roof upgrades. o Wall insulation values remain the same as planned in 2008 o Floor insulation values remain the same as planned in 2008 o See Attachments for the Revised Envelope Compliance Calculations and Assumptions Update Details for Wall Insulation o The details for the wall insulation may want to be updated to include the use of a thermally broken clip system for supporting the exterior cladding through the continuous rigid insulation. o Since, 2008 there are new systems available that may be beneficial to utilize for this project. Such as fiberglass clips for installing the exterior cladding through the rigid insulation of 17
4 Building Envelope Impacts: 2009 Seattle Energy Code Impacts, continued: New requirements for Continuous Air Barrier and Building Air Leakage Testing o Section has new requirements for a continuous air barrier. Per discussions with NBBJ the project had already made provisions for having a continuous air barrier that is already documented well on the Permit Drawing set from Only minor modifications to the drawings would be required to comply with 2009 SEC requirements. No construction cost impacts are anticipated. o Section outlines the requirements for air leakage testing prior to Certificate of Occupancy for the building. These are new requirements in the 2009 SEC. Building to be sealed to have an air leakage of less than 0.40 CFM per SF of building envelope area at a pressure of 0.30 w.g. Option #1: Inspect During Construction, Test, & Report essentially if you do the inspections during constructions the building then you don t have pass the test. Only the results of the test are required to be reported to the city. Option #2: Pass the Test essentially if you decide to follow this test you must test and if you fail then you reseal the building until you can pass the test. The inspections and air leakage testing will have cost impacts that will need to be included in the project construction budget of 17
5 Building Envelope Impacts: 2009 Seattle Energy Code Impacts, continued: of 17
6 Building Envelope Impacts: 2009 Seattle Energy Code Impacts, continued: of 17
7 2009 Seattle Energy Code Impacts, continued: Mechanical System Impacts: Mechanical System Impacts: 2009 Seattle Energy Code Impacts: Increase Cooling Efficiency required at Main Rooftop Air Conditioning Units o Per discussion with Johnson-Barrow (Energy Labs local vendor) the estimated cost to upgrade would be an additional 5-10% of the unit first cost from This is on the order of $40,000 to $70, Seattle Energy Code Table 14-1A: 2006 Seattle Energy Code Table 14-1A: of 17
8 Mechanical System Impacts: 2009 Seattle Energy Code Impacts, continued, Airside Economizer Requirements changes will impact Tenant Improvement Options o The allowable amount of the airside non-economizer cooling capacity was restricted in the 2009 SEC to 20 tons (240,000 BTUH) or 10% of the building economizer capacity per the changes in Exception 9 of Section o This impacts the plan for 24/7 cooling without airside economizer for the building. o During the design of the 624 Yale project there were many discussions regarding alternate means for achieving airside economizer at the future tenant server rooms. Among these ideas were a dedicated outside air shaft, floor-by-floor outside air intake louvers, etc. None of these ideas were incorporated into the final design. o The project was planning on providing a condenser water riser with space coordination for a future fluid cooler on the roof to allow for 24/7 cooling via high-efficiency watercooled air conditioning units per Option 9a of Section 1433 Exception 9. o Non-Economizer Cooling Sizing for the fluid cooler and piping was as follows: 6.5 Floors 15 tons per floor of 24/7 cooling Planned: 97.5 tons of 24/7 cooling without airside economizer o Per 2009 Seattle Energy Code the tonnage of non-economizer cooling would be limited as follows by Exception 9 of 1433: 320 tons of cooling with airside economizer at ACU-1-R-1 and ACU-1-R-2 10% of 320 tons = 32 tons Available 32 tons of 24/7 cooling without airside economizer o Therefore, a new plan would be required to provide the same amount of future 24/7 cooling without airside economizer that was planned for Possible options: Floor-by-Floor Outside Air Intake and/or Exhaust Louvers Outside Air Intake and/or Exhaust Shafts Dedicated future rooftop units for 24/7 cooling o The other item to note is that the plan for the building may be very different depending on whether the building is marketed as a single tenant or multi-tenant office building: Multi-Tenant need for 24/7 cooling through all floors of the building is more likely Single Tenant Major server rooms can be located closer to the roof where it is more feasible to accommodate airside economizer from rooftop package units. Then the 30+ ton non-economizer allowance can be used on the lower floors of the building for smaller spot cooling loads. o Rushing recommends waiting until a tenant is found and then building the infrastructure for 24/7 cooling airside economizer as required into the tenant permit. This is a good plan as long as the building does not plan to move forward as a speculative office building of 17
9 Mechanical System Impacts: 2009 Seattle Energy Code Impacts, continued, 2009 Seattle Energy Code Section 1433 Exception 9: 2006 Seattle Energy Code Section 1433 Exception 9: of 17
10 Mechanical System Impacts: 2009 Seattle Energy Code Impacts, continued, o As a side note: Per ASHRAE airside economizer for cooling in Seattle s Climate is 64% more efficiency than cooling without airside economizer. Chapter 12 Energy Metering Natural Gas Sub-metering will have a minor impact of Tenant Improvements for Retail Kitchen Tenants o For a restaurant tenant sub-metering would only be required if they were utilizing the natural gas for both HVAC loads (heating) and Process Loads (cooking). Most likely the gas service would only be used for cooking as the plan is for the HVAC to have electric heat of 17
11 2009 Seattle Energy Code Impacts, continued: Electrical System Impacts: Electrical System Impacts: Below is a Summary of Changes that impact Electrical Systems planned for 624 Yale. Depending on how the electrical contractor and consultant want to redesign the system there are some pretty major changes to the electric one-line to comply with the 2009 Seattle Energy Code Seattle Energy Code Impacts: Lighting Allowances (w/sf) o Office Reduced to 0.90 w/sf from 0.95 w/sf. This will impact tenant lighting design marginally. Lighting Controls o Parking garage lighting is required to have occupancy controls o Lighting within the daylight zone is required to have primary and secondary daylight zone controls o Emergency egress is required to have controls to turn off when the building is not occupied. New Requirement for Energy Metering per Chapter 12 o Electrical riser design will be impacted to provide the ability to sub-meter the following uses within the building per Chapter 12: HVAC System Energy Lighting System Energy Plug Load System Energy Process Load System Energy (non anticipated) Misc Energy (domestic hot water & elevators) o Additionally an energy metering data acquisition system is required that has the following capabilities: Store 36 months of data Show daily, monthly, and annual energy consumption data Have permanent display for the building engineer Display shall show: the current energy demand for the whole building, updated for each energy source, as well as the average and peak demands for the previous day and the same day the previous year, and the total energy usage for the previous 12 months. o There are several ways to accomplish the new electrical sub-metering requirements. One of these is to provide an electrical panel for each of the sub-metering uses above. Each electrical panel can then be sub-metered accordingly. Panels can contain embedded meters or separate meters can be utilized of 17
12 Electrical System Impacts: 2009 Seattle Energy Code Impacts, continued, o New Requirement for Energy Metering per Chapter 12 Typical Office Floor Electrical Riser Diagram Planned per Permit drawing Electrical One-Line on E1.01: (drawings by Sequoyah Electric and Lane Coburn & Associates, LLC) Possible Revised Typical Office Floor Electrical One Line Riser Diagram: Typical office floor sub-metering calculations to gather end-use data by data acquisition system: o HVAC System Energy = Lighting Energy Plug Energy o Lighting System Energy (dedicated sub-meter) o Plug Load System Energy (dedicated sub-meters) of 17
13 Electrical System Impacts: 2009 Seattle Energy Code Impacts, continued, of 17
14 2009 Seattle Energy Code Impacts, continued: Renewable Energy Impacts: Renewable Energy Impacts: Below is a Summary of Changes required by the 2009 Seattle Energy Code Chapter 16 and Seattle DPD Director s Rule Per the 2009 SEC an onsite renewable energy is required. As an alternate per Director s Rule Renewable Energy Credits (REC s) can be purchased. o Based on the Gross Conditioned Space Footage for 624 Yale the approximate cost for the REC s purchase would be $22,000 to $25,000. The cost depends on the energy sector that the client wants to purchase the REC s from. o This is a much more cost effective than putting renewable energy on the site. Per the Director s Rule the REC s should be purchased prior to permit submission Seattle Energy Code Chapter 16 On-site Renewable Energy Systems On-site Renewable Energy vs Renewable Energy Credit Purchase Manual Input Auto Calculated Gross conditioned floor area: 191,750 SF Required On-site Renewable Energy: 500 BTU/SF Annual onsite production: 95,875 k-btu Onsite Solar Photovoltaic Renewable Energy Credit Purchase Total area of PV collectors: 1,871 SF Required REC's Purchase (kwh/sf): 125 kwh/sf System Rated Output 29.0 kw Required REC's Purchase: 23,969 kwh Approximate Total System Cost: $ 202,779 Cost of REC's/kWh $ $/kwh Typical panel footprint (angled at 47.5 ): 14 SF Approximate Total Cost of REC's $ 22,531 Number of panels: kwh/sf required Post July 1, 2012 Notes: 2009 Seattle Energy Code Chapter 16 requires on-site renewable energy systems for all new buildings and all additions of more than 5,000 square feet to existing buildings Seattle Energy Code Section 1621 requires annual energy production of 500 BTU/SF of gross conditioned floor area Seattle Energy Code Director's Rule alternate requires REC's Purchase 125 kwh/sf of gross conditioned floor area of 17
15 Renewable Energy Impacts: 2009 Seattle Energy Code Impacts, continued, of 17
16 Renewable Energy Impacts: 2009 Seattle Energy Code Impacts, continued, of 17
17 2009 Seattle Mechanical & Plumbing Code Impacts: Below is a Summary of Changes that impact Mechanical and Plumbing Systems planned for 624 Yale. Overall only minor modifications are required to comply with the 2009 Seattle Codes Seattle Mechanical Code Impacts: Access panels for cleanout of Type 1 Grease Exhaust Ductwork are required at every level o Minor cost impact to provide an access panel on each floor. Clearance around Type 1 Grease Exhaust Ductwork o Clearance changed to 6 clearance minimum (from 3 ). Shaft coordinated for 624 Yale was slightly oversized and has minimum required clearance for 2009 code. No impact Seattle Plumbing Code Impacts: Requirement that all domestic cold and hot water valves meet NSF-61 requirements. o Minor cost impact to upgrade valves to meet NSF-61 requirements of 17
CITY PLAN REVIEW AND INSPECTION. Lisa Fleming Brown, CPM
CITY PLAN REVIEW AND INSPECTION Lisa Fleming Brown, CPM Houston Commercial Energy Conservation Code (2011) A choice of 2009 IECC or ASHRAE 90.1-2007 with amendments. Effective September 2, 2011. Complete
BPC Green Builders. Green building for new and existing homes. Health Comfort Energy
BPC Green Builders Green building for new and existing homes Health Comfort Energy Mechanical Systems Installed HVAC Systems Primary energy source large, roof mounted, solar thermal array (AET flat plate)
Building Performance Evaluation Guide Version 1.7
Building Performance Evaluation Guide Version 1.7 Prepared by Center for Energy and Environment January 2014 Minnesota Sustainable Building 2030: Building Performance Evaluation Guide p 1 1. Schematic
Energy Savings in High-Rise Buildings Using High-Reflective Coatings
Energy Savings in High-Rise Buildings Using High-Reflective Coatings Executive Summary: Nevertheless, the simulation analyses showed that when designing a building for low energy consumption, even in cold
Table 1: Prescriptive Envelope Requirements: Residential WOOD FRAME WALL R-VALUE MASS WALL R-VALUE CEILING R-VALUE
June 24, 2011 North Carolina Has a New Energy Conservation Code! By R. Christopher Mathis Executive Summary On Friday, June 24, 2011, Governor Beverly Perdue signed SB 708 into law and, with it, approved
Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks
Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same
Protocol for the Certification of Energy Simulation Software: Second edition, September 2011
Copyright Agrément South Africa, September 2011 The master copy of this document appears on the website: http://www.agrement.co.za SANS 10400: The application of the National Building Regulations: Protocol
ENERGY STAR Data Verification Checklist
ENERGY STAR Data Verification Checklist 86 ENERGY STAR Score 1 Sample Property Primary Function: Office Gross Floor Area (ft²): 200,000 Built: 1980 For Year Ending: 04/30/2013 Date Generated: 06/28/2013
Selecting Energy Efficient New Windows in Georgia
Selecting Energy Efficient New Windows in Georgia www.efficientwindows.org January 016 ENERGY STAR Zones 1. Meet the Energy Code & Look for the ENERGY STAR Windows must comply with your local energy code.
HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY
HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY Benson Kwong, CVS, PE, CEM, LEED AP, CCE envergie consulting, LLC Biography Benson Kwong is an independent consultant providing
Selecting Energy Efficient New Windows in Arizona
Selecting Energy Efficient New Windows in Arizona www.efficientwindows.org January 016 ENERGY STAR Zones 1. Meet the Energy Code & Look for the ENERGY STAR Windows must comply with your local energy code.
NOTICE OF INCORPORATION United States Legal Document
NOTICE OF INCORPORATION United States Legal Document All citizens and residents are hereby advised that this is a legally binding document duly incorporated by reference and that failure to comply with
Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver
Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver Designing an Effective Envelope Roofs Below Grade Walls and slabs Glazing & Windows Opaque portions of walls 2 3 Energy
Residential Weatherization Plus Program
Since 1982, Cowlitz PUD has been helping its customers reduce their monthly electric bills and make their homes more comfortable through our weatherization programs. Under the current program Residential
Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls
PCA R&D Serial No. 415 Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls by John Gajda and Martha VanGeem 000 Portland Cement Association KEYWORDS Concrete,
IECC Compliance Guide for Homes in Virginia
IECC Compliance Guide for Homes in Virginia Amended Version of 2012 International Energy Conservation Code July 14, 2014 Climate Zone Since the entire state of Virginia falls in the IECC Climate Zone 4,
Selecting Energy Efficient Replacement Windows in Nevada
Selecting Energy Efficient Replacement Windows in Nevada www.efficientwindows.org January 06 STAR Zones. Meet the Energy Code & Look for the STAR Windows must comply with your local energy code. Windows
Energy Savings with Window Retrofits
Center for Energy and Environment Energy Savings with Window Retrofits Presentation to Energy Design Conference & Expo Duluth, MN February 25, 2014 Agenda v Background v Introduction: What are window retrofits?
2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012
2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,
Section 2: Estimating Energy Savings and Incentives
Section 2: Estimating Energy Savings and Incentives 2.1 Estimating Energy Savings and Incentives... 2 2.2 Customized Measures - Estimation Software... 2 2.2.1 AC&R I - High Efficiency Chiller... 3 2.2.2
PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW
CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW PRELIMINARY BUILDING REVIEW two sets of the following: Architectural/engineering design development drawings indicating size of the building,
ENERGY STAR Certified Homes, Version 3 Cost & Savings Estimates
November 1, 2013 Contents ENERGY STAR Certified Homes, Version 3 Section 1: Executive Summary... 3 Section 2: Detailed Incremental Cost Estimates... 6 Section 3: Incremental Cost & Savings of the Thermal
Protocol for the Certification of Energy Simulation Software: First edition, December 2009
Copyright Agrément South Africa, December 2009 The master copy of this document appears on the website: http://www.agrement.co.za Protocol for the Certification of Energy Simulation Software: First edition,
EarthCents (DSM) Program Summary
EarthCents (DSM) Program Summary Renewable Energy EarthCents Programs Solar Water Heating This program is available to residential customers for the installation of a qualifying solar thermal water heater.
Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now
Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs
Total Building Commissioning: Case Study of the U.S. District Courthouse in Salt Lake City, Utah, USA
Total Building Commissioning: Case Study of the U.S. District Courthouse in Salt Lake City, Utah, USA Boggarm S. Setty, P.E., Fellow ASHRAE Setty & Associates, Ltd. 3040 Williams Drive, Suite 600, Fairfax,
Deep Energy Savings in Existing Buildings
Case Study Deep Energy Savings in Existing Buildings Overview Site Details Owner: Alliance for Sustainable Colorado Location: Denver, CO Building Type: Office Project Description: Major Renovation Size
Solar Energy Utilisation in Buildings
Solar Energy Utilisation in Buildings P. Karava, PhD Assistant professor Department of Civil and Environmental Engineering University of Western Ontario 2 Modern Buildings Change in architectural style
Energy Efficiency in Buildings
Energy Efficiency in Buildings Supplemental Guide to SANS 10400-XA & SANS 204 V. 3.0 Registered to: The Drawing Studio Image: digitalart / FreeDigitalPhotos.net Report Date: 26 August 2014 Practice Name:
2009 IECC Update. Scope. Content. International Energy Conservation Code
2009 IECC Update International Energy Conservation Code Scope The code applies to both residential and commercial buildings. In the code, the United States is divided into eight climate zones which are
Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes
Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes Vincent Pedalino FSL Home Improvements Phoenix, AZ 1 HVAC Basics Ways to improve the performance of existing air conditioning
Analysis of 2009 International Energy Conservation Code Requirements for Residential Buildings in Kansas City, Missouri
PNNL-20699 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Analysis of 2009 International Energy Conservation Code Requirements for Residential Buildings in Kansas City, Missouri
Case Study -Sandy Grove Middle School First Net Positive Energy P3 School In North Carolina
Case Study -Sandy Grove Middle School First Net Positive Energy P3 School In North Carolina Public-Private Partnership (P3) Government - provides incentive(s): transfer of asset (land), one time grant,
Process and Impact Evaluation of Roseville Electric s Residential New Construction, HVAC Retrofit and Commercial Custom Rebate Programs: FY2007/08
Process and Impact Evaluation of Roseville Electric s Residential New Construction, HVAC Retrofit and Commercial Custom Rebate Programs: FY2007/08 Submitted to: Roseville Electric February 27, 2009 Final
Building Energy Modelling. prescriptive
Building Energy Modelling prescriptive An alternative to Design for SANS 10400-XA Contents Complying with the new building energy standard - SANS 10400-XA 3 Compliance options Two rational design routes
HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems
HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems Fundamental Principles of Environmentally Responsible, Energy Efficient Buildings 1. Energy efficiency is
Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany
Life Cycle Costing Analysis of Water-cooled Chillers Chillventa Nuremburg, Germany Spring 2012 Description Life Cycle Cost Analysis is a method of determining and comparing the total costs of investment
Selecting Energy Efficient New Windows in Texas
Selecting Energy Efficient New Windows in Texas www.efficientwindows.org January 06 Zones. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are certified
Uncovering Myths and Opportunities of Advanced Building Envelope Technologies: BIPV, Roofing and Windows
Uncovering Myths and Opportunities of Advanced Building Envelope Technologies: BIPV, Roofing and Windows Marc LaFrance Technology Development Manager US Department of Energy Building Technology Program
Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV 89118 ~ (702) 455-3000
Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV 89118 ~ (702) 455-3000 IECC Submittal Requirements Building Permit Guide Ronald L. Lynn Director/Building & Fire
Mechanical Systems Proposal revised
Mechanical Systems Proposal revised Prepared for: Dr. William Bahnfleth, Professor The Pennsylvania State University, Department of Architectural Engineering Prepared by: Chris Nicolais Mechanical Option
THE ROOFPOINT ENERGY AND CARBON CALCULATOR A NEW MODELING TOOL FOR ROOFING PROFESSIONALS
THE ROOFPOINT ENERGY AND CARBON CALCULATOR A NEW MODELING TOOL FOR ROOFING PROFESSIONALS James L. Hoff, VP of Research Center for Environmental Innovation in Roofing Tools and Models Tools require models
Builder Specifications for Solar Ready Homes
Builder Specifications for Solar Ready Homes This document specifies the essential elements required to make a new home ready for the future installation of roof-mounted solar domestic hot water and photovoltaic
Building Energy Codes 101 October 23, 2013. Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance
Building Energy Codes 101 October 23, 2013 Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance OVERVIEW 1. Introduction 2. Energy Code Development 3. Adoption Process 4. Elements
Market Potential Study for Water Heater Demand Management
Market Potential Study for Water Heater Demand Management Rebecca Farrell Troutfetter, Frontier Associates LLC, Austin, TX INTRODUCTION Water heating represents between 13 and 17 percent of residential
SYSTEMS INTEGRATION SYSTEMS INTEGRATION. Air handler uses heat recovery on exhaust air to temper incoming ventilation air Oxbow skylight
100% outside air intake Air handler uses heat recovery on exhaust air to temper incoming ventilation air Oxbow skylight Smoke evacuation Natural convection exhaust Atrium skylight Phase change material
Below are detailed instructions for using the EMS load calculator.
Introduction The EMS load calculator is designed to make load calculating as painless as possible. For sizing the equipment, only the first three tabs (Steps 1, 2 & 3) need to be completed. This process
Saint Cloud Business Center
Saint Cloud Business Center 14 7th Avenue North Saint Cloud, MN 56303 For Sale Located on 7th Avenue in the heart of downtown across from the Court House Square. A large professional reception area with
2015 1322) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY
MINNESOTA ENERGY CODE COMPLIANCE COLLABORATIVE 2015 Minnesota Residential Energy Code (MR 1322) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY (July 15, 2015 Update) Note: The following information contains
Differentiating Energy Modeling Software!
Differentiating Energy Modeling Software! What works, what doesn t, and when it matters! A Boulder Green Building Guild brownbag presentation by! Adam Stenftenagel! Principal! Sustainably Built! Heat Movement
Improving thermal insulation of concrete sandwich panel buildings
Improving thermal insulation of concrete sandwich panel buildings Jørgen Munch-Andersen Danish Building Research Institute, Aalborg University LCUBE conference, Vienna 17-18 April 2007 Outline A general
EnergyPro Building Energy Analysis. Assisted Living Building
EnergyPro Building Energy Analysis Assisted Living Building EnergyPro Building Energy Analysis for an assisted living building Project Scope The purpose of the EnergyPro energy model was to evaluate the
PENNSYLVANIA GREEN ENERGY LOAN FUND
PENNSYLVANIA GREEN ENERGY LOAN FUND Procedures Manual for Quantifying Energy Savings A. Introduction A building project applying for a GELF energy loan must demonstrate that it will result in a 25% reduction
24.301.161 INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by
24.301.161 INCORPORATION BY REFERENCE OF INTERNATIONAL ENERGY CONSERVATION CODE (1) The Department of Labor and Industry adopts and incorporates by reference the International Code Council's International
Solar Cooling. Methods and Applications. Sargon Ishaya, PE, LEED AP
Solar Cooling Methods and Applications Sargon Ishaya, PE, LEED AP Objectives Describe two practical methods for solar cooling Give air conditioning engineers the confidence to offer customers a mechanical
Directorate for the Built Environment Building Standards Division
Directorate for the Built Environment Building Standards Division Energy Management Solutions Ltd Investigation of measures to improve the energy performance of a existing building: Retail JUNE 2009 Report
Energy Efficiency Analysis for a Multi-Story Commercial Office Building. (LG Multi V Water II Heat Recovery VRF System)
Energy Efficiency Analysis for a Multi-Story Commercial Office Building (LG Multi V Water II Heat VRF System) Commercial Air-Conditioning Engineering Study VRF-ES-BL-001-US 011M05 Executive Summary Contents
Certificate of Compliance ENV-1-C and Envelope Component Method ENV-2-C
Certificate of Compliance ENV-1-C and Envelope Component Method ENV-2-C Forms Quality You Can Trust Since 1886... From North America s Largest Roofing Manufacturer CERTIFICATE OF COMPLIANCE (Part 1 of
UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
Home Energy Evaluation Report
Home Energy Evaluation Report Nate Begeman, 1550 Saint Francis Dr San Jose, CA 95125 Air Infiltration Current Air Leakage 2,852 Current Air Changes Per Hour 0.91 Recommended Air Changes Per Hour 0.35 Percent
Residential HVAC Load Sizing Training October 14, 2015. David Kaiser Green Code Plan Reviewer
Residential HVAC Load Sizing Training October 14, 2015 David Kaiser Green Code Plan Reviewer DCRA - Green Building Division Regulations of green codes including: Green Building Act Green Construction Code
Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings
Advanced Energy Design Guide LEED Strategies for Schools and High Performance Buildings Today s Presenters Stephen Koontz, LEED AP Energy Services Leader Tampa Bay Trane Allen Irvine General Sales Manager
research highlight Highly Energy Efficient Building Envelope Retrofits for Houses
research highlight June 2012 Technical Series 12-103 Highly Energy Efficient Building Envelope Retrofits for Houses introduction In Canada approximately 30% of all energy is consumed in buildings, with
3-D Modeller Rendered Visualisations
Recognised energy Dynamic Simulation Modelling (DSM) software DesignBuilder is a user interface to the EnergyPlus DSM. EnergyPlus builds on the most popular features and capabilities of BLAST and DOE-2
ANALYSIS 2: Photovoltaic Glass Replacement
ANALYSIS 2: Photovoltaic Glass Replacement Problem Identification Bridgeside II is designed to accommodate 80 percent lab space and 20 percent office space. Laboratory equipment can consume a considerable
Identify Ways to Save with Energy Audits
Identify Ways to Save with Energy Audits Kristine Chalifoux Director of Management and Operations, SEDAC Mary Bentsen Education & Training Coordinator, SAIC, an Ameren Illinois ActOnEnergy partner Kristine
City of Chula Vista, California Municipal Code (2011) Title 15 Buildings and Construction
Solar-Ready Homes Chula Vista (California), City of. 2011. Municipal Code. Title 15, Buildings and Construction; Chapter 15.24, Electrical Code and Regulations; Section 15.24.065, Photovoltaic Pre-Wiring
INDIANA COMMERCAL ENERGY CODE BASELINE STUDY
INDIANA COMMERCAL ENERGY CODE BASELINE STUDY March 21, 2005 Report Prepared for Indiana Department of Commerce, Energy and Recycling Division One North Capitol Avenue, Suite 700 Indianapolis, IN 46204
THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.
THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT. A Diagrammatic representation of the relationship between the
BUILDING SAFETY UNIT
POLICY Page 1 of 5 SUBMITTAL REQUIREMENTS FOR ONE AND TWO FAMILY DWELLINGS, ADDITIONS AND RENOVATIONS All submittals shall be site specific and designed to the provisions of the 2012 International Residential
Florida Building Code, 5th Edition (2014) June 30 th, 2015
Florida Building Code, 5th Edition (2014) Update June 30 th, 2015 FBC Update, 5 th Edition (2014) Uses 2012 ICC as its Base Code as required by Florida Legislature Causing sections to be changed Books
Energy Efficiency: Integrated Design and HVAC Systems HEALTHCARE - TOP 5 GREEN BUILDING STRATEGIES
EPA Publication 909-F-07-001 What? Energy use in healthcare facilities is higher than nearly all other building types. With rising energy costs and climate change concerns energy efficiency is financially
Condensing Boiler Efficiency
Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2
Tennessee. Energy and Cost Savings. for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC
BUILDING TECHNOLOGIES PROGRAM Tennessee Energy and Cost Savings for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC 1 2009 AND 2012 IECC AS COMPARED TO THE 2006 IECC Tennessee
2013 BUILDING ENERGY EFFICIENCY STANDARDS
2013 BUILDING ENERGY EFFICIENCY STANDARDS Title 24, Part 6, and Associated Administrative Regulations in Part 1 CALIFORNIA ENERGY COMMISSION Edmund G. Brown Jr., Governor MAY 2012 CEC 400 2012 004 CMF
Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages
Objectives Increase awareness of the types of economizers currently used for data centers Provide designers/owners with an overview of the benefits and challenges associated with each type Outline some
Selecting Energy Efficient New Windows in Florida
Selecting Energy Efficient New Windows in Florida www.efficientwindows.org January 06 Zones. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are certified
BASE PERMIT FEE x.80 = PLAN CHECK FEE*: $ BASE PERMIT FEE x.10 = MECHANICAL INSPECTION FEE: $ BASE PERMIT FEE x.12 = ENERGY CODE REVIEW FEE: $
Development Services Department A. Building Permit Fees For New Construction, Tenant Improvements and Residential Remodels For Production Homes See Page 2 TOTAL VALUATION (Materials and Labor) FEE $1 to
Green Globes for New Construction Pre-Assessment Checklist for Project Managers
1 Green Globes for New Construction Pre-Assessment Checklist for Project Managers What is Stage I assessment? As the design phase draws to a close, and your Green Globes questionnaire is completed through
HIGH PERFORMANCE BUILDING ENVELOPES. Dave Seifert
Dave Seifert Design Construction Commissioning PRESENTATION OVERVIEW About BCRA How Did We Get Here? What is a High Performance Building Envelope? Energy Conservation Considerations Durability Considerations
Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis
Components HVAC General System Selection Life Cycle Cost Analysis Outdoor Air Design Values Indoor Air Design Values Outdoor Air Ventilation Welding Ventilation Temperature Control Systems Ductwork HVAC
Colorado Energy and Cost Savings
BUILDING TECHNOLOGIES PROGRAM Colorado Energy and Cost Savings for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC 1 2009 AND 2012 IECC AS COMPARED TO THE 2006 IECC Colorado
SAM HOUSTON STATE UNIVERSITY
PART 1: GENERAL 1.01 General Requirements A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the
Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001
Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001 Presented by: Liberty Engineering, LLP 1609 Connecticut Avenue
APPENDIX C FORMS 2010 FLORIDA BUILDING CODE ENERGY CONSERVATION C.1
APPENDIX C FORMS 2010 FLORIDA BUILDING CODE ENERGY CONSERVATION C.1 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = The lower the Energy Performance Index, the more efficient
In the Fall 2002 issue of HHE News I examined
Choosing Replacement Windows 1 For Your Home Mark Pierce In the Fall 2002 issue of HHE News I examined reasons for, and against, replacing older windows with new, energy efficient windows. That article
2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT
Presentation Synopsis Heating, Ventilating and Air Conditioning Building Condition Assessment Vancouver, B.C. Prepared for: EPIC Prepared by: Douglas Spratt, P.Eng Douglas Spratt & Associates Ltd. www.dspratt-associates.com
ENERGY EFFICIENCY COMPARISON
California Energy Commission STAFF REPORT ENERGY EFFICIENCY COMPARISON California s Building Energy Efficiency Standards and the International Energy Conservation Code and American Society of Heating,
ENERGY EFFICIENCY PLAN REVIEW CHECKLIST
GEORGE CHAVEZ, City Building Official DAVID YELTON, Building Inspection Manager NESTOR OTAZU, Community Preservation Manager BUILDING & SAFETY DIVISION 455 North Rexford Drive, 1 st Floor Beverly Hills,
Energy Efficiency Analysis for a Multi-Story Commercial Office Building. (LG Multi V III Heat Recovery VRF System)
Energy Efficiency Analysis for a Multi-Story Commercial Office Building (LG Multi V III Heat Recovery VRF System) Commercial Air-Conditioning Engineering Study VRF-ES-BK-011-US 011L18 Executive Summary
Mississippi. Energy and Cost Savings. for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC
BUILDING TECHNOLOGIES PROGRAM Mississippi Energy and Cost Savings for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC 1 2009 AND 2012 IECC AS COMPARED TO THE 2006 IECC
Diego Ibarra Christoph Reinhart Harvard Graduate School of Design
Building Performance Simulation for Designers - Energy DesignBuilder // EnergyPlus Tutorial #2 Load Schedules GEOMETRY LOADS RESULTS Diego Ibarra Christoph Reinhart Harvard Graduate School of Design OVERVIEW