PARTICLE SIZE. Instrument Solutions

Similar documents
ZETA POTENTIAL ANALYSIS OF NANOPARTICLES

Particle Size Analysis

DYNAMIC LIGHT SCATTERING COMMON TERMS DEFINED

Bruce B. Weiner, Walther W. Tscharnuter, David Fairhurst Brookhaven Instruments Corporation Holtsville, NY US

High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering

Molysulfide. Particle Size Analysis

Pore size and BET surface area. analysis at your fingertips. SA Gas Adsorption Analyzer

IN-LINE PARTICLE SIZE MEASUREMENTS FOR CEMENT AND OTHER ABRASIVE PROCESS ENVIRONMENTS

ISO A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners

7. DYNAMIC LIGHT SCATTERING 7.1 First order temporal autocorrelation function.

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Lecture 24 - Surface tension, viscous flow, thermodynamics

Fluid Mechanics: Static s Kinematics Dynamics Fluid

Supporting Information

3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY

A GUIDEBOOK TO PARTICLE SIZE ANALYSIS

Rodenstock Photo Optics

Encoders for Linear Motors in the Electronics Industry

Setting Size Specifications

WOOD WEAR TESTING USING TRIBOMETER

ZEISS T-SCAN Automated / COMET Automated 3D Digitizing - Laserscanning / Fringe Projection Automated solutions for efficient 3D data capture

Introduction to Fourier Transform Infrared Spectrometry

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

A New Technique Provides Faster Particle Size Analysis at a Lower Cost Compared to Conventional Methods

Acousto-optic modulator

PARTICLE SIZE. By: Philo Morse, MS, and Andrew Loxley, PhD. INTRODUCTION are not as stringent as for scattering techniques.

A PHOTOGRAMMETRIC APPRAOCH FOR AUTOMATIC TRAFFIC ASSESSMENT USING CONVENTIONAL CCTV CAMERA

Tube Control Measurement, Sorting Modular System for Glass Tube

Math Matters: Dissecting Hydrometer Calculations

The Sievers 900 Series TOC Analyzers

SIZE OF A MOLECULE FROM A VISCOSITY MEASUREMENT

Kinetic Theory of Gases. Chapter 33. Kinetic Theory of Gases

Particle size. Integrated systems for particle sizing. detailed specification sheets from

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Christine E. Hatch University of Nevada, Reno

Raman Spectroscopy Basics

Signal to Noise Instrumental Excel Assignment

Endoscope Optics. Chapter Introduction

Synthetic Sensing: Proximity / Distance Sensors

Alignment Laser System.

Automotive Applications of 3D Laser Scanning Introduction

Basic Principles in Microfluidics

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Determination of Ultra Low Chlorine (and Sulfur) in Oil

Blue Laser Technology Applied to the Microtrac Unified Scatter Technique for Full- Range Particle Size Measurement.

Optical Metrology. Third Edition. Kjell J. Gasvik Spectra Vision AS, Trondheim, Norway JOHN WILEY & SONS, LTD

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Sample preparation for X-ray fluorescence analysis

BASIC PRINCIPLES OF PARTICLE

PARTICLE SIZE AND SIZE DISTRIBUTION OF SUPERABRASIVE POWDERS ION C. BENEA, Ph.D. Engis Corporat ion

Module 13 : Measurements on Fiber Optic Systems

AS COMPETITION PAPER 2008

Interference. Physics 102 Workshop #3. General Instructions

2 Absorbing Solar Energy

Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH))

Unmatched Metal Hardness Testing

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

Simplicity. Reliability. Performance

Optical Design Tools for Backlight Displays

Refractive Index Measurement Principle

Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors

Determination of Acceleration due to Gravity

Sensori ottici e laser nelle applicazioni industriali

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

MILESTONE H E L P I N G C H E M I S T S

Highly efficient flue gas analyzer

When the fluid velocity is zero, called the hydrostatic condition, the pressure variation is due only to the weight of the fluid.

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

SPECIAL APPLICATIONS

still different technique of assessment.

Using light scattering method to find The surface tension of water

High Resolution RF Analysis: The Benefits of Lidar Terrain & Clutter Datasets

Pressure in Fluids. Introduction

Lecture 3: Optical Properties of Bulk and Nano. 5 nm

A. Types of Mixtures:

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Theremino System Theremino Spectrometer Technology

How To Program A Laser Cutting Robot

KINETIC MOLECULAR THEORY OF MATTER

Liquid Conductivity: Measuring Conductivity in Saline Water Solutions (Teacher s Guide)

John D. Dyson, Manager Municipal Water Group Infilco Degremont Inc. Richmond, VA

Method Development and Validation for Particle Size and Shape Measurements

Application Note: Absorbance

Experiment #5: Qualitative Absorption Spectroscopy

Fiber Optics: Fiber Basics

Introduction to acoustic imaging

Color holographic 3D display unit with aperture field division

Zetasizer Nano-ZS User Instructions

CASE HISTORY #2. APPLICATION: Piping Movement Survey using Permalign Laser Measurement System

Roxar Multiphase meter 2600 Class - Turning information into value

Alphasense Application Note AAN DESIGNING A POTENTIOSTATIC CIRCUIT


Dynamics in nanoworlds

DMA-80 Direct Mercury Analyzer

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Automatic and Objective Measurement of Residual Stress and Cord in Glass

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

Transcription:

PARTICLE SIZE Instrument Solutions

There are numerous techniques by which to determine the quantity vs. equivalent size distribution of a collection of particles. Selecting the right technique is critical in obtaining reliable data. No single technique is appropriate for all materials or applications. For this reason, Micromeritics offers you six different particle size analyzer choices, each employing different analytical techniques, to fit your application. Dynamic Light Scattering and Zeta Potential Dynamic Light Scattering (DLS), also known as Photon Correlation Spectroscopy (PCS), is a well-established particle size distribution technique for submicron particles and macro molecules. The speed at which particles are diffusing due to random (Brownian) motion is measured. Detecting the rate at which the scattered light intensity of these diffusing particles fluctuates enables the determination of particle size. For a homogeneous suspension, DLS provides accurate and statistically representative results in minutes. Based on the Electrophoretic Light Scattering (ELS) technique, zeta potential is determined by electrophoretic mobility measurement in a particle suspension or molecular solution. Detecting the Doppler shift when an electric field is applied enables mobility measurement. Zeta potential is a key indicator of the stability of colloidal dispersions, which is an essential factor for surface modification and product transportation. 2500 µm 2000 µm 1500 µm 1000 µm 750 µm Air Permeability 500 µm This technique uses the principle of pressure drop across a packed bed of powder. By varying the sample height, and hence the porosity of the bed, average surface area and particle size can be determined as a function of pressure drop and flow rate in accordance with the Carmen equation. Electrical Sensing Zone The electrical sensing zone (ESZ) technique, also known as the Coulter principle, analyzes samples particle by particle. Requiring only a small volume of sample for analysis, it provides the highest particle size measurement resolution of the techniques presented here. A homogeneously dispersed suspension of sample material is prepared in an electrolytic solution. A tube with a small orifice of short path length is submerged in the suspension, an electrode being positioned on both sides of the orifice. A pump establishes a flow of electrolyte through the orifice, providing a conductive path between the two electrodes and a small electrical current is established between them. Both electrolyte and particles pass through the orifice. The particles, being non-conductive, impede the electrical current flow as they enter the orifice. This creates an electrical signal proportional to the volume of the particle. Each individual particle is counted and classified according to volume, thus producing a volume frequency distribution. The particles are considered to be spherical and a particle diameter can be determined from volume. NanoPlus HD 0.1 nm 12.3 µm SAS 0.2 µm 75 µm Elzone II 0.4 µm 266 µm 250 µm 100 µm 10 µm 1 µm 0 SIZE

2500 µm 2000 µm 1500 µm 1000 µm X-Ray Sedimentation Sedimentation velocity of suspended particles can be obtained by measuring the concentration of particles remaining in suspension with time. This technique measures the distribution of equilibrium velocities of particles settling through a liquid under the influence of gravity. Stokes law relates these velocities to particle diameters for spherical particles. Non-spherical particles are measured in terms of the diameter of a sphere of the same material that settles at the same velocity in the same suspension liquid. Dynamic Image Analysis 750 µm 500 µm 250 µm 100 µm 10 µm 1 µm 0 SediGraph III Plus 0.1 µm 300 µm Particle Insight 1 µm 800 µm Saturn DigiSizer II 0.04 µm 2500 µm Particles are suspended homogeneously in a carrier liquid. They pass through a thin flow cell in the optical path. Light is transmitted through the flow cell, thus projecting silhouettes of the particles onto a high-resolution camera sensor. The high frame rate and high resolution of the camera combined with a high-speed host computer enables the characterization of thousands of particles per second in real-time. This technique is ideal for applications where shape, not just diameter, is critical information for predicting raw material performance. Static Light Scattering The size of particles can be determined from the manner in which they scatter light. The most common application of this technique is low angle light scattering (LALS) in which an assemblage of particles is illuminated by a source of monochromatic, coherent light. All information about particle size resides in the intensity versus angle characteristics of the scattering pattern; therefore, precise measurement of the light scattering characteristics is fundamental to obtaining good particle size data. RANGE

NanoPlus HD Zeta Potential ASTM: E2490 ISO: 13321, 22412, 13099-2 The NanoPlus HD is a unique instrument that utilizes photon correlation spectroscopy and electrophoretic light scattering techniques to determine particle size and zeta potential. The instrument is compact and easy to use with an extended analysis range, intuitive software, and multiple sample cells to fit the user s application. Sub-Sieve AutoSizer (SAS) Air-Permeability ASTM: B330, C721 The SAS is a modernized and improved version of the Fisher Model 95 Sub-Sieve Sizer. The SAS has drastically improved the wellestablished air-permeability particle sizing technique. Air-permeability techniques generate average specific surface area data for powder samples. The specific surface area of particles has a significant impact on the physical properties of powders Two model configurations: nano particle sizing or a combination of nano particle sizing and zeta potential Measures particle size of samples suspended in liquids in the range of 0.1 nm to 12.3 µm with sample suspension concentrations from 0.00001% to 40% Measures zeta potential of a sample suspension in the range of -500mV to +500mV with concentrations from 0.001% to 40% The NanoPlus AT Auto-Titrator accessory and a wide variety of sample cells are also available and has been the focus of much attention from pharmaceutical, paint, toner, and geological applications. Measures particle size in a range of 0.2 to 5 µm Designed to generate Fisher number results identical to that of its predecessor, the Fisher Sub-Sieve Sizer Simple set-up and real time data display Elzone II Particle Count ASTM: C690, D4438, F577 ISO: 13319 Unlike other measurement techniques, the electrical sensing zone method can size samples that have assorted optical properties, densities, colors, and shapes. The Elzone II can determine the size, number, concentration, and mass of innumerable organic and inorganic materials. Sizes and counts both organic and inorganic materials from 0.4 to 266 µm Different conductive liquids can be used without needing to enter an extensive set of liquid properties Does not require previous knowledge of material properties (density, refractive index) Automated features include: start-up, run, and shut-down routines; blockage detection and clearing; flushing/rinsing; and calibration A CCD camera provides real-time video display of the aperture to assure a clear path through the detection zone

SediGraph III Plus ASTM: B761, C958, C110 ISO: 13317-3 This analyzer combines the proven SediGraph analytical technique with advanced instrumentation features to provide superior repeatability, accuracy, and reproducibility. The SediGraph III directly measures mass by x-ray absorption and determines particle size by direct measurement of settling velocity. Direct measurements require no modeling. Particle size range of 0.1 to 300 µm Complete particle accountability Features lifetime warranty (7 years) on the x-ray tube Optional MasterTech 052 autosampler provides unattended analysis of up to 18 samples Particle Insight Particle Shape ISO: 13322-2 Particle shape information about raw materials enables manufacturers to control their process with a much higher level of sensitivity. The Particle Insight is a dynamic image analyzer which is ideal for applications where the particle shape, not just the diameter, is critical raw material information. Three size range model options: 1 to 150 µm, 3 to 300 µm, and 10 to 800 µm Real time data display with a unique optics camera with high frame rate and resolution for enabling analysis of tens of thousands of particles in seconds Select from 30 size/shape parameters for the best match to the particles being analyzed Thumbnail images of all analyzed particles for post run viewing and shape filtering with customizable particle type views Recirculating sample module and optics enable statistically valid measurements in a very short amount of time Standard system is compatible with both aqueous as well as organic fluids Saturn DigiSizer II High Definition ASTM: B822, C1070, D4464 ISO: 13320 This state-of-the-art laser particle size analyzer utilizes advanced optics, CCD technology, and over three million detector elements to maximize the ability to deliver high sensitivity and a high-resolution measurement of articulations in the scattering pattern. This allows a high degree of size discrimination in the sample population. Higher size resolution reveals information about the material that goes undetected with other laser particle sizing systems, providing more accurate results in even the most complex sample type. CCD technology with high angular resolution of up to 70 degrees provides accurate results within the range of 40 nanometers to 2.5 millimeters Fast, detailed results that are repeatable on and reproducible between every Saturn DigiSizer Liquid sample handling unit for automatic sampling, diluting, and dispersion. Available in both standard and low volume configurations

Micromeritics Instrument Corporation 4356 Communications Drive, Norcross, GA 30093 USA To request a quote or additional product information, visit micromeritics.com Contact your local Micromeritics sales representative or our Customer Service Department at 770-662-3636 All Rights Reserved 2016. Micromeritics Instrument Corporation. Norcross, Ga 30093. 770-662-3636. Printed in the USA. 008/42771/00