Technical Data. Installation

Model/Sprinkler Identification Numbers

4077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE FAX

Price List January 1, 2015

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

PROTECTO 401 Price List

LIST PRICE BOOK MALLEABLE CAST IRON PRESS FITTINGS FOR SCH BLACK & GALVANIZED STEEL PIPE

COMPLIANCE WITH LAWS, CODES, AND STANDARDS

Model RV-1 Pressure Relief Valve 2 to 8 Inch (DN50 to DN200), 250 psi (17,2 bar) Pilot-Operated, Globe and Angle Body Styles General Description

IMPORT CAST IRON THREADED FITTINGS Price Sheet SPF.CI-3.14C Effective March 10, 2014 Cancels Price Sheet SPF.CI-7.12C of July 2, 2012

1-1/2 Inch (DN40) 9 lbs. (4,1 Kg) 8 lbs. (3,6 Kg) Flange Groove* N/A N/A. Flange Flange N/A N/A

Mechanical Products. Mechanical Products M06-1

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

HIGH VELOCITY WATER SPRAY NOZZLE

FOR THE MOST CURRENT PRODUCT / PRICING INFORMATION ON ANVIL PRODUCTS, PLEASE VISIT OUR WEBSITE AT

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

FIRE PROTECTION VALVES Price Sheet FPVLV-7.15 Effective: July 6, 2015 Cancels Price Sheet FPVLV-2.15 of February 2, 2015


FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

NOTE: All orders are accepted on the basis of prices in effect at the time of shipment.

STAINLESS STEEL FITTINGS & COUPLINGS Price Sheet GR.SS-5.14 Effective: May 12, 2014 Cancels Price Sheet GR.SS-5.13 of May 28, 2013

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

2013 Edition. Flanged fittings 30"-64" NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

RING JOINT SYSTEMS 207

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

Installation Instructions

3M Housings DS Series

Steel Fire Sprinkler Pipe

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Type D3 PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description

Installation Manual DIAPHRAGM WELL TANK

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

ALL THREAD ROD Price Sheet ATR-6.16 Effective: June 13, 2016 Cancels Price Sheet ATR-5.14 of May 12, 2014

FOAM CHAMBER MODEL - FC

TD01211 PIN: NX nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

OAK WORKBENCH WITH 2 DRAWERS

SECTION FIRE HYDRANTS

Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.

American National Standard For Electrical Rigid Steel Conduit (ERSC)

OWNER S MANUAL. Certified to NSF/ANSI 61. This product is covered by one or more of the following US patent US D692, 524 S

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

STEEL PIPE NIPPLES - Seamless Price Sheet PnS-5.11 Effective: May 23, 2011 Cancels Price Sheet PnS-2.11 of February 7, 2011

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

08.08 Vic-Check Valves

Installation Instructions

Model: Model: Description: Voltage: Amps: Ice Type: Unit Weight:

TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013

RZ Guardrail System Installation Manual

SECTION GROUND WATER STORAGE TANKS

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

HotLok Pass Through Blanking Panel

Vogt Valves The Connection Bulletin for Extended Body Forged Steel Valves Welded Bonnet, Bolted Bonnet, Class 800 & Class 1500 CB 22

Commercial Cardiovascular Equipment

Sprinkler Identification Numbers (SINs) Technical Data

WARRANTY CERTIFICATE

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

ANGLgear. right angle drives Inch and Metric Series. The Original Right Angle Gear Drive Made in the U.S.A.

Ceiling Mount Air Handler Manual

SECTION STORM DRAINAGE SYSTEM

Calvert USA, Inc. Attic Stairs

DV-5 Deluge Valve with Remote-Resetting, Pressure-Reducing Trim 4 Inch and 6 Inch (DN100 and DN150) General Description.

SECTION PIPE HANGERS AND SUPPORTS

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

How To Get A Water Line Repair Program To Pay For A House To Be Fixed

User Manual (English)

2015 PRICE LIST. PRICING EFFECTIVE JULY 06, Rev. 1.3/07-15 Supersedes Price List April 1, 2014, Rev. 1.2/02-15

Engineering Specifications

Series 4000 Fiberglass Pipe and Fittings

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

VW TDI (Golf, Jetta, New Beetle) Upgrade Turbocharger

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

PS/2 Extender USER MANUAL.

SECTION DUCTILE IRON PIPE AND FITTINGS

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

SECTION DUCTILE IRON PIPE AND FITTINGS

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

Wastewater Capital Projects Management Standard Construction Specification

Part I - Installation

SINGLE STAGE INLINE FIRE PUMP

Machine Safety Switch: SI-LM40 Series Limit Switch Style

Say Hello to Your Precision Cooker

Copper Meter Resetters

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

TC Electronic Extended Warranty Policy

INSTRUCTION MANUAL IM042. Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Transcription:

Technical Services: Tel: (800) 38-932 / Fax: (800) 79-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Grooved Fittings General Description LPCB Vd S The grooved fittings provide an economical and efficient method of changing direction, adding an outlet, reducing, or capping grooved piping systems. Grooved fittings are available in durable ductile iron or fabricated steel as indicated. Note: 50S and 59S fittings are special short radius fittings with smaller center to end dimensions than standard grooved fittings. Depending on the size and coupling used, there may be interferences at the bolt pads that require repositioning of the coupling orientation. The use of flange adapters is not recommended with s 50S and 59S fittings. Contact Tyco Fire Products for details. WARNING The Fittings described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data See Fire Protection Submittal Sheet for Pressure Rating and Listing/Approval Information Approvals: UL, FM, ULC, VdS, and LPCB; Note: See Fire Protection Submittal Sheet for exact Listing / Approval information. Material: Cast: s: 20, 20, 29, 250, 260, 50, 50, 59, 50DE, 50S, 50S and 59S - Ductile iron conforming to ASTM A-536, Grade 65-45-2 Fabricated Steel: s 39, 392, 393, 32, 33, 32, 327, 34 and 350 - Carbon Steel, (s / - are Schedule 40); (s - are Schedule 30), conforming to ASTM A-53 Grade B Protective Coatings: Non-lead orange paint Fire brigade red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-53 Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 25-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (0) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (0) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer s representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Page of 6

Page 2 of 6 s 20, 20, 29, and 260 20 29 20 260 Friction Resistance* (Expressed as Equivalent Straight Pipe) Elbow Tee 90 45 Branch Run Inches Feet Feet Feet Feet mm Meters Meters Meters Meters 4.9.0 4.8.9 4 0.3.5 2 2.3.2 2.3 48.3 0.7.8 0.7 2 3.2.6 3.2 60.3.0 2.5.0 2 2 3.9 2.0 9.8 3.9 73.0.2 3.0.2 76.mm 4. 2. 0.3 4..2 3..2 3 4.9 2.2 4.9 88.9.5 0.7 3.7.5 mm 6.5 3.3 6.3 6.5 2.0.0 5.0 2.0 4 6.5 3.3 6.3 6.5 4.3 2.0.0 5.0 2.0 33.0mm mm 4.0 4. 20.0 20.0.2.3 6. 6. 5 8.2 4. 2 8.2 4.3 2.5.3 6.3 2.5 59.0mm mm 4.8 4.8 23.8 23.8 7.2 7.2 6 9.9 5.0 24.8 9.9 68.3 3.0.5 7.6 3.0 26.3mm 3. 6.6 32.8 3. 4.0 2.0 0.0 4.0 8 3. 6.6 32.8 3. 29. 4.0 2.0 0.0 4.0 0 6.5 8.3 4.3 6.5 273.0 5.0 2.5 2.6 5.0 2 9.9 9.9 49.7 9.9 323.4 6. 3.0 5. 6. For reducing tees and branches, use the value that is corrosponding to the branch size. Example: for x x tee, the branch value is feet. * Friction resistance for all elbows and tees except s 50S and 59S. 20 20 29 260 45 Elbow 90 Elbow Tee End Cap Appx. Wt. Appx. Wt. Appx. Wt. Appx. Wt. Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs. mm Kg. mm Kg. mm Kg. mm Kg. / / 2 / 76.mm.75.75 2.25 2.25 2.50..8 2.2 2.2 3.5.0.2 2.0 3.0 3.0 4.5.8 2.7 7.0 4.. 57.2 57.2 63.5 0.8.0.0.6 2.0 0.8.2 2.6 2.6 3.2 2 2 2 2 23.9 2 0.2 0.3 mm 2.88 5.5 4.75 8.5 4.75.5 73.0 2.5 20.7 3.9 20.7 5.2 3.00 5.2 5.00 8.5 5.00.8.00 2.6 76.2 27.0 3.9 27.0 2.2 33.0mm 7.7 5.25.3 5.25 3.5 33.4 5. 33.4 4.8 mm 7.7 8.5.3 3.5 5.3 7.0 2.00 4.7 5.0 3.5 3.9 5. 6. 6.9 7.7 23.4 2 2. 2.3 59.0mm 3.50 2.0 6.00 4.6 6.00 3.9 88.9 5 6.6 5 6.3 mm 3.50 3.50 2.0 2.0 8.5 8.5 26.0 26.0.00.00 7.5 7.5 88.9 88.9 8.4 8.4.8.8 2 2 3.4 3.4 26.3mm 23.0 7.75 36.5 7.75 45.0 96.9 6.6 96.9 2 0" 4.75 5.25 23.0 3.0 40.0 7.75 9.00 0.00 36.5 60.0 67.0 7.75 9.00 0.00 45.0 72. 92.5.9.25.25 2.8 20.0 36.0 20.7 33.4 4. 8. 96.9 228.6 254.0 6.6 27.2 3 96.9 228.6 254.0 2 32.7 42.0 30.2 3.8 3.8 9. 6.3 - Available with tapped plugs, contact Tyco Fire & Building Products.

Page 3 of 6 s 50, 50, 59 and 50DE B A 50 50 59 50DE 50 50 59 50DE 45 Elbow 90 Elbow Tee 90 Drain Elbow Appx. Wt. Appx. Wt. Appx. Wt. A B Appx. Wt. Inches Lbs. Inches Lbs. Inches Lbs. Inches Inches Inches Lbs. mm Kg. mm Kg. mm Kg. mm mm mm Kg. /.75.0 /.75..2.8 0.8.8 2.0 2.7 0.8.2 2 / 2.25 2.50 3.00 3.50 2.2 3.5 5.2 8.5 2.0 5.00 3.0 4.5 8.5 3.5 8.5 5.00 7.0.8 7.0 26.0 5.00 2.34 2.85 3.38 3.92 2.7 3.7 7.0 3.0 3.4 57.2 63.5 76.2 88.9.0.6 3.9 27.0 2.0 3.9 6. 8.4 27.0 2.6 3.2 7.7.8 27.0 59.4 7 85.9 99.6.2.7 3.2 5.9 6. 23.0 7.75 36.5 7.75 45.0 7.75 4.95 26.3 96.9 6.6 96.9 2 96.9 25.7.9 s 50S, 50S and 59S 50S 50S* 59S* Friction Resistance 50S, 50S & 59S (Expressed as Equivalent Straight Pipe) Elbow Tee 90 45 Branch Run Inches Feet Feet Feet Feet mm Meters Meters Meters Meters 2 3.2.6 3.2 60.3.0 2.5.0 2 2 3.9 2.0 9.8 3.9 73.0.2 3.0.2 4. 2. 0.3 4. 76.mm.2 3..2 3 4.9 2.2 4.9 88.9.5 0.7 3.7.5 4 6.5 3.3 6.3 6.5 4.3 2.0.0 5.0 2.0 4. 20.0 mm.3 6. 5 8.2 4. 2 8.2 4.3 2.5.3 6.3 2.5 4.8 23.8 mm 7.2 6 9.9 5.0 24.8 9.9 68.3 3.0.5 7.6 3.0 8 3. 6.6 32.8 3. 29. 4.0 2.0 0.0 4.0 2 / 76.mm mm mm 50S 50S 59S 45 Elbow 90 Elbow Tee Appx Wt. Appx. Wt. Appx. Wt. Inches Lbs. Inches Lbs. Inches Lbs. mm Kg. mm Kg. mm Kg..8.5 2. 0.8 0.7.0 2.25 2.2 3.00 2.2 3.00 3.0 57.2.0 76.2.0 76.2 2.25 2.2 3.00 2.3 3.00 3. 57.2.0 76.2.0 76.2 2.50 3.5 3.38 3.0 3.38 4. 63.5.6 85.9.3 85.9.9 3.00 5.2 4.00 5.6 4.00 7.7 76.2 2.6 3.5 7.7 4.88 8.6 4.88 2.0 3.5 24.0 3.9 24.0 8.5 4.88 8.8 4.88 2.0 3.9 24.0 3.9 24.0 3.50 2.0.00 5.0 88.9 5.0 6.8 3.50 2.0.2 5.2 88.9 5. 6.9 23.0 6.88 23.4 6.88 3.2 74.8 74.8 4.2 *Note: 50S and 59S fittings are special short radius fittings with smaller center to end dimensions than standard grooved fittings. Depending on the size and coupling used, there may be interferences at the bolt pads which requires repositioning of the coupling orientation. The use of flange adapters is not recommended with s 50S and 59S fittings. Contact Tyco Fire Products for details.

Page 4 of 6 s 250 and 350 250 Cast 350 Fabricated s 3 to 6 350 Fabricated s 8 to 2 s 250 and 350 Concentric Reducer - Groove x Groove Appx. Wt. Appx. Wt. Appx. Wt. Inches Lbs. Inches Lbs. Inches Lbs. Inches mm Kg. Inches mm Kg. Inches mm Kg. *2 x 4 2.50.0 3.50 4.2 4.00 *mm 63.5 x 3 88.9.9 *6 x 5 2.6 *2 x 2 2.50.3 3.50 4.4 5.00 2.2 *mm x 4 8 x 2 27.0 5.5 *2 2 x 2 2.50.2 3.50 4.6 5.00 2. 63.5 5 x 2 88.9 2. 8 x 2 2 27.0 5.5 *76.mm x 2 2.50.5 3.50 4.6 5.00 2.0 63.5 0.7 5 x 2 88.9 2. 8 x 3 27.0 5.5 *76.mm x 2 2.50.6 3.50 4.5 5.00.9 63.5 0.8 5 x 2 2 8 x 4 27.0 3 x 4 2.50.3 3.50 4.4 5.00.3 5 x 3 8 x 5 27.0 5. 3 x 2 2.50.3 3.50 4.5 5.00 0.8 *5 x 4 8 x 6 27.0 4.9 *3 x 2 2.50.3 4.00 5.5 6.00 *mm x 3 2.5 0 x 4 5 0.0 *3 x 2 2 3.00.5 4.00 6.0 6.00 2.6 *mm 76.2 0.7 x 4 0 x 5 5 9.8 *3 x 76.mm 3.00 2.0 4.00 5.6 6.00 2. *mm 76.2 x mm 2.5 0 x 6 5 9.6 4 x 4 3.00 2.2 4.00 6.0 6.00 76.2.0 *6 x 2 0 x 8 5 8.9 4 x 2 3.00 2.3 4.00 6.0 7.00 2 76.2.0 6 x 2 2 2 x 4 77.8 2.7 *4 x 2 3.00 2.3 4.00 6.0 7.00 30.0 76.2.0 *6 x 76.mm 2 x 6 77.8 3.6 *4 x 2 2 3.00 2.3 4.00 6.0 7.00 2 76.2.0 6 x 3 2 x 8 77.8 2.7 *4 x 76.mm 3.00 3.2 4.00 5.9 7.00 33.0 76.2.5 *6 x 4 2 x 0 77.8 5.0 4 x 3 3.00 2.6 4.00 6.3 76.2.2 *6 x mm Note: s marked with an asterisk (*) are only available in 250 Cast. s without an asterisk are only available in 350 Fabricated. ADA CAP A D B C Pipe Dimensions O.D. Takeout Center to End Net Outlet A B C D Wt. Inches NPT* Inches Inches Inches Inches Lbs. Inches mm mm mm mm Kg. /2.25.75.89 0.77 3.8 0.3 /2 3 /4 /2.900.37.25.25.75.75 2.02.89.89 2 0.77 48.3 34.8 3.8 3.8 5.3 0.3 2 3 /4 /2 2.375.37 7.25.97.75 2.02.89.89.06.28 2 60.3 34.8 37.3 3.8 50.0 5.3 2 /2 3 /4 2.875.37 7.97 2.02.89.50.28 73.0 34.8 37.3 50.0 5.3 0.7 * ISO-7 threaded outlets are available upon request.

Page 5 of 6 s 39, 392, 393, 32 and 33 39 393 33 392 32 / / 2 / 0" s 39, 392 and 393 Adapter Nipples 32 33 22 /2 Elbow /4 Elbow Appx. Wt. Appx. Wt. Appx. Wt. Inches Lbs. Inches Lbs. Inches Lbs. mm Kg. mm Kg. mm Kg. 4.00 0.8.75.38 0.2 35. 0.2 4.00.75.38 0.2 35. 0.2 4.00.2.88.38 47.8 0.3 35. 0.3 4.00.9 0.7.50. 0.3 38. 4.00 2.5 2.25.50.2. 57.2 38. 6.00 5.5 2.63.75 2.2 5 2.5 66.8..0 6.00 7.4 2.88 4. 3.3 5 3.4 73.2.9.5 6.00 3.3 5.6 4.6 5 4.3 7 2.5 2. 6.00 4.2 3.88. 8.7 5 6.4 98.6 5.0 3.9 0 27.0 4.38 4.0 2.3 9. 203.2 2.2.3 6.4 54. 4. 0 33.0 4.88 22.0 2.25 6.7 203.2 5.0 24.0 0.0 57.2 7.6 s 327 and 34 327 34 / / 2 / 0" 327 Cross 34 50 lbs. Flange Adapter Appx. Wt. Appx. Wt. nches Lbs. Inches Lbs. mm kg. mm kg. 2.0 4.00 2.8 69.6.3 2.2 4.00 3.2 2.0.5 2.7 4.0 5.2.2 5.0 4.00 2.3 3.6 7. 4.00 0.2 3.2 4.6 5.00.9 6.00 7.2 27.0 5 7.8 7. 6.00 2 7.8 5 9.7 27.5 6.00 26.0 2.5 5.8 7.75 47.0 6.00 38.4 96.9 2.3 5 7.4 9.00 6 0 65.0 228.6 30.8 203.2 2 0.00 07.0 0 9.0 254.0 48.5 203.2 4.3

Page 6 of 6 32 32 32 Reducing Tee Appx. Wt. Appx. Wt. Inches Lbs. Inches Lbs. Inches mm Kg. Inches mm Kg. 2 x 2 x 2.0 4 6 x 6 x 4 26.6 2. 2 x 2 x 2.7 2 6 x 6 x 5 27.0.2 2.2 2 2 x 2 2 x 4.2 4 8 x 8 x 2 7.75 36.2.9 96.9 6.4 2 2 x 2 2 x 4.2 2 8 x 8 x 3 7.75 36.5.9 96.9 6.6 2 2 x 2 2 x 2 4.3 8 x 8 x 4 7.75 36.6 2.0 96.9 6.6 3 x 3 x 5.3 2 8 x 8 x 5 7.75 36.8 96.9 6.7 3 x 3 x 2 5.5 8 x 8 x 6 7.75 37.0 2.5 96.9 6.8 3 x 3 x 2 2 0 x 0 x 2 9.00 57. 2.6 228.6 25.9 4 x 4 x 5.00 9.8 4 0 x 0 x 3 9.00 57.4 27.0 4.4 228.6 26.0 4 x 4 x 5.00 9.9 2 0 x 0 x 4 9.00 57.6 27.0 4.5 228.6 26. 4 x 4 x 2 5.00 0. 0 x 0 x 5 9.00 57.8 27.0 4.6 228.6 26.2 4 x 4 x 2 5.00 0.3 2 0 x 0 x 6 9.00 5 27.0 4.7 228.6 26.3 4 x 4 x 3 5.00 0 x 0 x 8 9.00 58.4 27.0 4.8 228.6 26.5 5 x 5 x 2 4.5 2 x 2 x 3 0.00 80.2 6.6 254.0 36.4 5 x 5 x 2 4.8 2 2 x 2 x 4 0.00 8 6.7 254.0 36.5 5 x 5 x 3 5.2 2 x 2 x 5 0.00 80.7 6.9 254.0 36.6 5 x 5 x 4 2 x 2 x 6 0.00 8 7.2 254.0 36.7 6 x 6 x 2 26.5 2 x 2 x 8 0.00 9.9 254.0 4.5 6 x 6 x 2 26.5 2 2 x 2 x 0 0.00 9.8 2.0 254.0 4.6 6 x 6 x 3 26.5 2.0 General Notes: It is the Designer s responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (IH-000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. TYCO FIRE PRODUCTS, 45 North Cannon Avenue, Lansdale, Pennsylvania 9946 Certified Company Printed U.S.A.