MICROSURGICAL Nd:YAG LASER USED IN OPHTHALMOLOGY



Similar documents
A DATA ACQUISITION, PROCESSING AND STORAGE SYSTEM FOR AN OPHTHALMIC INSTRUMENT: FOTOBIOFTAL-1

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

Alignement of a ring cavity laser

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

Cataract l Glaucoma l Retina l Refractive. VISULAS YAG III. The Fastest YAG Laser. Laser Precision Par Excellence.

Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, , 1 April 1998)

Synthetic Sensing: Proximity / Distance Sensors

Science In Action 8 Unit C - Light and Optical Systems. 1.1 The Challenge of light

Theremino System Theremino Spectrometer Technology

OPTICAL FIBERS INTRODUCTION

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Interference. Physics 102 Workshop #3. General Instructions

Millijoules high master-slave pulse ratio 532 nm picosecond laser

Color holographic 3D display unit with aperture field division

Laser safety in the lab

A Guide to Acousto-Optic Modulators

Development of MEMS micromirrors for intracavity laser control

Data Destruction for Optical Discs

Computer Vision: Machine Vision Filters. Computer Vision. Optical Filters. 25 August 2014

GRID AND PRISM SPECTROMETERS

Defense & Security Symposium 2004, Kigre Er:glass Publication #144. Eye-Safe Erbium Glass Laser Transmitter Study Q-Switched with Cobalt Spinel

Imaging techniques with refractive beam shaping optics

Light and its effects

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND

Physics 441/2: Transmission Electron Microscope

LASERS in Ophthalmology. Health Care Technology Unit ORBIS Flying Eye Hospital

High Power Fiber Laser Technology

Measuring of optical output and attenuation

Module 13 : Measurements on Fiber Optic Systems

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Infrared Viewers. Manual

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

LASER ENGRAVING REFLECTIVE METALS TO CREATE SCANNER READABLE BARCODES Paper P516

ENGINEERING METROLOGY

Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term

INFITEC - A NEW STEREOSCOPIC VISUALISATION TOOL BY WAVELENGTH MULTIPLEX IMAGING

A More Efficient Way to De-shelve 137 Ba +

A down-under undergraduate optics and photonics laboratory

LASER SAFETY PLAN. The Hamilton Eye Institute at The University of Tennessee 930 Madison Avenue Memphis, Tennessee 38163

Laser Tattoo Removal

Review Vocabulary spectrum: a range of values or properties

Lab 9: The Acousto-Optic Effect

Application Report: Running µshape TM on a VF-20 Interferometer

Study Guide for Exam on Light

Polarization of Light

Example of SOP for IR Laser

Acousto-optic modulator

TPC laser calibration system

The CVD diamond booklet

Discontinued. LUXEON V Portable. power light source. Introduction

Diffraction of Laser Light

Beam shaping to generate uniform Laser Light Sheet and Linear Laser Spots

Applications of confocal fluorescence microscopy in biological sciences

HIGH POWER FREE SPACE AND FIBER PIGTAILED ISOLATORS

Introduction to microstructure

A wave lab inside a coaxial cable

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

A concise guide to Safety Glasses, the different standards and the effects of light on the eye. Contents. Links. Year of publication: 2010

DIODE PUMPED CRYSTALASER

Incoherent beam combining using stimulated Brillouin scattering in multimode fibers

DETERMINING THE POLARIZATION STATE OF THE RADIATION CROSSING THROUGH AN ANISOTROPIC POLY (VINYL ALCOHOL) FILM

Recommended alignment procedure for Shaper 6_6 / Focal- Shaper 9

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

Experimental results for the focal waveform and beam width in the focusing lens with a 100 ps filter

FIBRE OPTICS & LASERS

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

Introduction to reflective aberration corrected holographic diffraction gratings

arxiv:astro-ph/ v1 15 Sep 2005

Four Wave Mixing in Closely Spaced DWDM Optical Channels

Fig.1. The DAWN spacecraft

Analysis of Blind Microvias Forming Process in Multilayer Printed Circuit Boards

On the beam deflection method applied to ultrasound absorption measurements

Radiant Dyes Laser Accessories GmbH

Helium-Neon Laser. Figure 1: Diagram of optical and electrical components used in the HeNe laser experiment.

Electrical tests on PCB insulation materials and investigation of influence of solder fillets geometry on partial discharge

Digital Holography using a Laser Pointer and Consumer Digital Camera Report date: June 22 nd, 2004

METHODS FOR PULSED LASER DEPOSITION OF LARGE-AREA FILMS USING MORE THAN ONE TARGET

Optical laser beam scanner lens relay system

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.

Simulation of Gaussian Pulses Propagation Through Single Mode Optical Fiber Using MATLAB . MATLAB

Ti:Sapphire Lasers. Tyler Bowman. April 23, 2015

Experiment 5. Lasers and laser mode structure

Understanding Laser Beam Parameters Leads to Better System Performance and Can Save Money

Reflective Optical Sensor with Transistor Output

INFRARED MONITORING OF 110 GHz GYROTRON WINDOWS AT DIII D

Status of the Free Electron Laser

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS

Physics 202 Problems - Week 8 Worked Problems Chapter 25: 7, 23, 36, 62, 72

EFFICIENT USE OF SHORT PULSE WIDTH LASER FOR MAXIMUM MATERIAL REMOVAL RATE Paper# M602

waves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object

ME 472 Engineering Metrology

NOVEL FOCUSING OPTICS FOR IR LASERS Paper 1504

LASER DIAGRAM TABLE OF CONTENTS. SKY Technologies Inc. Laser Diagram. Technical Specifications. Laser Operation.

RAY TRACING UNIFIED FIELD TRACING

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

Transcription:

MICROSURGICAL Nd:YAG LASER USED IN OPHTHALMOLOGY D. SAVASTRU 1, S. MICLOS 1, C. COTIRLAN 1, MARINA MUSTATA 1, ESOFINA RISTICI 1, TEODORA BREZEANU 1, SIMONA DONTU 1, M. RUSU 1, V. SAVU 1, A. STEFANESCU 2 1 National Institute of R&D for Optoelectronics INOE-2000 2 Eye Clinical Hospital of Bucharest Received September 26, 2005 A microsurgical ophthalmological laser for posterior capsulotomy and pupil membran-ectomy, allowing stereoscopic examination of eye s transparent medium and microsurgical procedures in the anterior and posterior chambers using the photodisruptive effect is presented. A circular variable filter and two LED-phototransistor pairs are used to get a precise energy dosing. Key words: photodisruptor, Nd:YAG laser, ophthalmology, capsulotomy, membranectomy. 1. INTRODUCTION The system produces a beam of infrared light at 1064 nm (a Q-switch Nd:YAG laser) and this laser delivers a chosen amount of energy to a focal point of approximately 10 microns diameter which causes an acoustic wave [1, 2, 3]. The wave disrupts adjacent tissue. This is known as the photo disruptive effect (Fig. 1). Fig. 1 Photo disruptive effect scheme. Paper presented at the National Conference of Physics, 13 17 September 2005, Bucharest, Romania. Rom. Journ. Phys., Vol. 51, Nos. 7 8, P. 833 837, Bucharest, 2006

834 D. Savastru et al. 2 The laser beam was spatially filtered in order to obtain the TEM oo and it was focused at 150 microns behind the visible image plane to reduce the risk of pitting of the intraocular lens when performing posterior capsulotomy. The laser system is adapted to an ophthalmic stereomicroscope used in ophthalmology. 2. EXPERIMENTAL SET-UP The system yields an infrared laser beam of 1064 nm wavelength (Fig. 2). A Q-switch Nd:YAG laser has been designed and built. As active medium a 3 mm diameter and 50 mm length laser rod was used. One of the rod ends is a partially reflecting mirror having 27% reflectivity at 1064 nm. The other rod end was antireflex dielectrically coated at 1064 nm. In order to obtain an optical active resonator a high reflecting mirror was used (reflectivity > 99.8% at 1064 nm). The values of the transmitted laser light energy are obtained by a variable neutral density filter. The used energy range is 0.5 10 mj. Also we have obtained 4 10 ns pulse length. The collimated laser radiation is reflected by a mirror with 100% reflectivity for 1064 nm at 90 degrees to enter in the objective. This objective has 100 mm focal length. Laser beam is deflected at 180 by two optical prisms P 1 and P 2. Laser beam is passed through a collimated system with a 12 magnification, is attenuated by a variable neutral filter and finally, it will be focused by the objective of the microscope at 150 microns behind the object plane to avoid the damage of the Intraocular Lens. Diameter of the laser beam in focal point is less than 10 microns. Two infrared LED-phototransistor pairs are used to position the filter. The calibration curves for the LED-phototransistor pairs and for the laser beam versus the neutral variable filter transmission were obtained. They are used to obtain the desired energy values of the laser beam for different surgical procedures. The aiming system uses a laser diode with 635 nm wavelength, less than 1 mw output power, split into two beams and then directed through the objective marking the object plane. This aiming system presents the evolution of the diameter and the position of the Nd:YAG laser pulse and also of the depth where the focal point of the laser pulse is located. The measurement of the pulse length was done using a Tektronix 3032A oscilloscope. 3. RESULTS AND DISCUSSION In order to obtain a short laser pulse, about 8 ns length, a Cr 4+ :YAG crystal as optical passive Q-switch was used. Using an oscilloscope as Tektronix TDS

3 Microsurgical Nd:YAG laser used in ophthalmology 835 3032 the pulse length of laser radiation was registered (Fig. 3). For a BDN Q-switch with the transmission 40%, the pulse length is about 14 ns. So, in this case the Cr +4 :YAG is better to use as Q-switch. The small pulse length is necessary to obtain a very short time to develop the plasma in the focus and such the acoustic wave in order to obtain the photo disruptive effect. Fig. 3 The pulse length oscilloscope image. As represented in Fig. 4, a variable neutral filter is used to obtain an exact value for the laser beam energy. The laser beam (the magenta spot) is filtered by rotating a circular variable density filter (OD 0 to OD 2). The rotation is accomplished by a stepper controlled by a microcontroller. The exact rotation of Fig. 4 The variable neutral filter and the LED/laser spots.

836 D. Savastru et al. 4 the disk needed by a chosen energy is found using two IR LEDs (named the Left LED the green spot and the Right LED the dark blue spot) and two phototransistors to determine the actual rotation angle of the disk and consequently to determine the actual transmission of the filter. The microcontroller rotates the filter using the stepper till the measured signals of the two LEDs reach the values prescripted for the corresponding chosen energy value. Fig. 5 shows the calibration curves of the laser energy and the corresponding signal level of the two LEDs. Fig. 5 Calibration curves for the transmitted laser beam versus the rotation of the neutral filter. The laser beam (1064 nm) is passed through a beam expander with a 12 magnification coefficient, than attenuated by a circular variable neutral filter, and finally, it is focused by the objective of the microscope in about 10 microns focal area diameter. We obtained energies up to 10.0 mj for capsulotomy and iridotomy in less than ±10% energy variations. 4. CONCLUSIONS An important parameter is the specific energy for a specific application. So, for the capsulotomy operation an energy of about 3 mj is enough, while for iridotomy operation an energy of about 7 9 mj is needed. We obtained energies in the range 0 10 mj with less than ±10% energy variations. The values of the

5 Microsurgical Nd:YAG laser used in ophthalmology 837 transmitted laser light are obtained using a variable neutral density filter. Two infrared LED-phototransistor pairs are used to position the filter. Also we have obtained a laser pulse length of 8 ns. The aiming system uses a laser diode with 635 nm wavelength, less than 1 mw output power, spit into two beams and then directed through the objective marking the object plane. The adjustment is made by superposing the two red laser diode beams in the visible image plane and the Nd:YAG laser beam strikes in the central part of them. In conclusion, BIOLASER is a very precise instrument allowing a very good applicability in ophthalmology. One of the advantages of this laser system is that the energies can continuous varies on a long field (0.5 10 mj), making possible a great numbers of application in clinical ophthalmology. The stereomicroscope will be exploited in the Eye Clinical Hospital in Bucharest and, after some months, it will be introduced in the Romanian Optical Enterprise (IOR) production. The preliminary clinical results show that this instrument is good enough to compete with other such instruments on the market. REFERENCES 1. Z. S. Sacks, F. Loesel et al., Transscleral photodisruption for treatment of glaucoma, Proc. SPIE, Vol. 3726, pp. 516 521, 1998. 2. P. I. Grecu, A. Stefanescu-Dima, Cristina Stoica, Luminita Ursea, Biolaser-1 Romanian initiative in domain of photodisruptive ophthalmic lasers, Nat. Conf. for Ophthalmology, Sept. 2002, Cluj, Romania. 3. D. Savastru, S. Miclos, C. Cotîrlan, E. Ristici, M. Mustata, M. Mogîldea, G. Mogîldea, T. Dragu, R. Morarescu, Nd:YAG Laser System for Ophthalmology: BIOLASER-1, J. Optoelectronics and Advanced Materials, Vol. 6, No. 2, p. 497 502, 2004.